Fracture Strength of All-Ceramic 3-Unit Fixed Partial Dentures Manufactured by CAD/CAM and Copy-Milling Systems (CAD/CAM 및 카피밀링 시스템을 이용하여 제작한 구치부 3-유닛 고정성 국소의치의 파절강도)

  • Kang, Hoo-Won;Kim, Hee-Jin;Kim, Jang-Ju;Ko, Myung-Won
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.95-103
    • /
    • 2012
  • Purpose: Fracture strength of all-ceramic 3-unit fixed partial dentures manufactured by CAD/CAM and copy-milling systems were evaluated. Methods: Zirconia cores were made by milling the pre-sintered zirconia block by CAD/CAM or copy milling method followed by subsequent sintering. By building-up the corresponding porcelains on the core, all-ceramic bridges were fabricated, and those were evaluated in comparison with PFM fixed partial denture. Results: During the flexural test of the 3-unit PFM bridge, the porcelain started to chip or break at 507.28(${\pm}62.82$)kgf and the metal framework did not break until the maximum load level of 800kgf which was set in the testing instrument of this study. However, among all-ceramic restoration test groups, Everest(EV) group showed a peeling off or breakage of the porcelain from 365.64(${\pm}64.96$)kgf and the core was broken at 491.77(${\pm}55.62$)kgf. Those values of Zirkonzahn(ZR) were 431.03(${\pm}58.47$)kgf and 602.74(${\pm}48.44$)kgf, respectively. The break strength of the porcelain of PFM(PM) group was significantly higher than that of EV (p<0.05) group and there was no significant difference when comparing to that of ZR (p>0.05). ZR group showed higher break strength than that of EV group however there was no significant difference (p>0.05). The break strength of cores were in the increasing order of EV < ZR < PM (p<0.05). Conclusion: We could find that even though the PM group fractured at much higher value than all-ceramic cores, the breakage values of the porcelain of PM group with crack formation or delamination, which will be regarded as clinical failure, was significantly higher than that of EV group and not significantly higher than that of ZR group at p-values of 0.05. The break strength of ZR group was higher than that of EV group at an insignificant level(p>0.05).

D-$\Pi$-A designed dye chromophores and nanoparticles: optical properties, chemosensor effects and PE/Aramid fiber colorations

  • Son, Young-A;Kim, Su-Ho;Kim, Young-Sung
    • Proceedings of the Korean Society of Dyers and Finishers Conference
    • /
    • 2010.03a
    • /
    • pp.40-40
    • /
    • 2010
  • Studies on attractive color changing property of dye chromophore and fluorophore have been greatly enjoyed in the related industrial and research fields such as optoelectronics, chemosensor, biosensor and so on. The optical property based on D-$\Pi$-A intramolecular charge transfer (ICT) system of chromophore molecules can be utilized as suitable sensing probes for checking media polarity and determining colorimetric chemosensing effect, especially heavy metal detection. These finding are obtained by absorption and emission properties. In this work, donor-acceptor D-$\Pi$-A type fluorescent dyes were designed and synthesized with the corresponding donor and acceptor groups. The selected donor moieties might be provided prominent amorphous properties which are very useful in designing and synthesizing functional polymers and in fabricating devices. Another reasons to choose are commercial availabilities in high purity and low price. Donor-bridge-acceptor (D-A) type dyes can produce impressive optical-physical properties, yielding them potentially suitable for applications in the synthesis of small functional organic molecules. Small organic functional molecules have unique advantages, such as better solubility, amorphous character, and represent an area of research which needs to be explored and developed. Currently, their applications in metalorganic compounds is rapidly expanding and becoming widespread in self-assembly processes, photoluminescence applications, chiral organocatalysts, and ingrafts with nanomaterials. Colloidal nanoparticles have received great attentions in recent years. The photophysical properties of nanoparticles, particularly in terms of brightness, photostability, emission color purity and broad adsorption range, are very attractive functions in many applications. To our knowledge background, colloidal nanoparticles have been enjoyed their applications in bio-probe research fields. This research interest can be raised by the advantages of the materials such as high photoluminescence quantum yields, sharp emission band, long-term photostability and broad excitation spectra. In recent, the uses of nanoparticles being embedded in a polymer matrix and binded on polymer surface have been explored and their properties such as photo-activation and strong photoluminescence have been proposed. The prepared chromophores and nanoparticles were investigated with absorption and emission properties, solvatochromic behaviors, pH induced color switching effects, chemosensing effects and HOMO/LUMO energy potentials with computer simulation. In addition, synthesized fluorophore dyes and particles were applied onto PE/Aramid fiber fluorescing colorations. And the related details were then discussed.

  • PDF

A Study on the Heavy Metals Concentrations in the Air of the Dental Laboratories, in the Blood and Urine of Dental Laboratory Technicians (치과기공실 공기중 및 치과기공사의 혈액, 요중 중금속 함량에 관한 연구)

  • Cha, Sung-Soo
    • Journal of Technologic Dentistry
    • /
    • v.10 no.1
    • /
    • pp.11-24
    • /
    • 1988
  • The purpose of this study was to determine the concentration of cadmium, nickel and chromium in the air of the work-place, blood of and urine of workers and compare the level of those heavy metals by the duration of work, work-place, process of work, smoking and other factors. In this study, 48 male dental laboratory technicans and 72 office workers as the control group were subjected. The concentration of cadmium, nickel and chromium in their blood sand urine, and that of heavy metals in the air of their work-rooms were examined and analyzed from June I 1987 to September 30, 1987. The results were as follows : 1. The concentration of cadmium in the air was the highest in the porcelain part, $0.0087{\pm}0.0016mg/m^3$, that of nickel was the highest in the crown bridge part, $0.4253{\pm}0.0052mg/m^3$, and that of chrnmium was highest in the partial denture part, $0.1063{\pm}0.0024mg/m^3$. 2. cadmium, nickel and chromium concentrations in the blood and urine of dental laboratory techincians were higher that in the office workers'. Especially the concentration of cadmium in the blood($1.92{\pm}1.23{\mu}g$/100ml) of th dental laboratory techician was about two times as high as that in the office workers'($0.90{\pm}0.73{\mu}g$/100ml), and the concentration of nickel in the urine($48.53{\pm}38.83{\mu}g$/e) of the dental laboratory thchnician was about two times as high as that in the office worker's($20.24{\pm}15.35{\mu}g$/e). 3. there was no difference in the concentration of cadmium, nickel and chromium in the blood and urine with a longer duration of work. 4. The concentration of cadmium and chromium in the blood and urine differed significantly depending upon the place of work. The concentration of cadmium was the highest in the blood of dental laboratory technicians working kin the poreclain part marking at $2.53{\pm}1.08{\mu}g$/100ml. The chromium level was the heighest in the blood of partial denture park workers with a concentration of $3.60{\pm}1.02{\mu}g$/100ml. Concerning the level of cadmium in urine, it was the highest in the porcelain part workers with a concentration of $3.41{\pm}3.15{\mu}g$/e. 5. The concentration of cadmium in the urine of metal trimming and polishing group($2.64{\pm}2.41{\mu}g$/e) was higher than that of non-metal trimming and polishing group($1.39{\pm}1.18{\mu}g$/e). 6. The concentration of chromium in the blood of smoking group($2.46{\pm}1.54{\mu}g$/100ml)was higher than that lf non-smoking group($1.54{\pm}1.25{\mu}g$/100ml). 7. The height positive correlation coefficient was shown between the concentration of nickel and chromium in the blood among the all correlations between 3metals(Cd, Ni, Cr) in the blood and those in urine. The correlation coefficient was relatively high(r=0.605,,p<0.01). In general, the higher the concentration of heavy metals in the air of work places the higher the concention lf them in the blood and urine of workers, mere attention should be paid to the working environment of dental laboratory workers, Furthermore, continuous biological monitoring and further research are required for an efficient health management for dental laboratory workers.

  • PDF

Change in Water Quality on Upper Stream of Mankyeong River (만경강 상류 지역 수질의 시기별 변화)

  • Moon, Young-Hee;Park, Jong-Min;Son, Jae-Gwon;Kim, Kea-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.4
    • /
    • pp.252-257
    • /
    • 2001
  • To get the basic information for the water quality improvement and control of water resource at Mankyeong river stream, the water quality in four site of main stream and three site of branch stream at the upper stream were investigated mainly from February to August in 2000. The water temperature was affected by depth, flow rate of the water, and air temperature, and ranged 6.4 to $30.8^{\circ}C$. The pH, DO and BOD values of the water was $5.9{\sim}9.7$, $4.6{\sim}14.50\;mg/L$, and $0.1{\sim}11.8\;mg/L$ range, respectively. The content of total nitrogen, $NO_3-N$ and $NH_4-N$ was $1.19{\sim}10.61\;mg/L$, $1.00{\sim}5.93\;mg/L$, and ND $(non\;detected){\sim}2.79$ mg/L, respectively. The concentration of total phosphorus was ND to 1.14 mg/L. The concentration of Cl ion was $3.5{\sim}196.4\;mg/L$. The content of Fe and Mn was $0.002{\sim}0.100\;mg/L$ and $ND{\sim}0.04\;mg/L$, respectively. The contents of heavy metal Cd, Cu, and Zn were $ND{\sim}0.03\;mg/L$, $ND{\sim}0.05\;mg/L$, and $0.001{\sim}0.17\;mg/L$, respectively. Pb was not detected in all the samples. The pH, total nitrogen contents, and total phosphorus content were frequently exceeded the water quality standard for agriculture. The degree of water pollution was very varied by the sampling place. The water quality was generally polluted in the dry season more than in rainy season. The highest level of water pollution observed in the area of Samyea Bridge among the 7 sites.

  • PDF

The Evaluation of Radiation Dose to Embryo/Fetus and the Design of Shielding in the Treatment of Brain Tumors (임산부의 전뇌 방사선 치료에 있어서의 태아의 방사선량 측정 및 차폐 구조의 설계)

  • Cho, Woong;Huh, Soon-Nyung;Chie, Eui-Kyu;Ha, Sung-Whan;Park, Yang-Gyun;Park, Jong-Min;Park, Suk-Won
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.4
    • /
    • pp.203-210
    • /
    • 2006
  • Purpose : To estimate the dose to the embryo/fetus of a pregnant patient with brain tumors, and to design an shielding device to keep the embryo/fetus dose under acceptable levels Materials and Methods : A shielding wall with the dimension of 1.55 m height, 0.9 m width, and 30 m thickness is fabricated with 4 trolleys under the wall. It is placed between a Patient and the treatment head of a linear accelerator to attenuate the leakage radiation effectively from the treatment head, and is placed 1 cm below the lower margin of the treatment field in order to minimize the dose to a patient from the treatment head. An anti-patient scattering neck supporters with 2 cm thick Cerrobend metal is designed to minimize the scattered radiation from the treatment fields, and it is divided into 2 section. They are installed around the patient neck by attach from right and left sides. A shielding bridge for anti-room scattered radiation is utilized to place 2 sheets of 3 mm lead plates above the abdomen to setup three detectors under the lead sheets. Humanoid phantom is irradiated with the same treatment parameters, and with and without shielding devices using TLD, and ionization chambers with and without a build-up cap. Results : The dose to the embryo/fetus without shielding was 3.20, 3.21, 1.44, 0.90 cGy at off-field distances of 30, 40, 50, and 60 cm. With shielding, the dose to embryo/fetus was reduced to 0.88, 0.60, 0.35, 0.25 cGy, and the ratio of the shielding effect varied from 70% to 80%. TLD results were 1.8, 1.2, 0.8, 1.2, and 0.8 cGy. The dose measured by the survey meter was 10.9 mR/h at the patient's surface of abdomen. The dose to the embryo/fetus was estimated to be about 1 cGy during the entire treatment. Conclusion : According to the AAPM Report No 50 regarding the dose limit of the embryo/fetus during the pregnancy, the dose to the embryo/fetus with little risk is less than 5 cGy. Our measurements satisfy the recommended values. Our shielding technique was proven to be acceptable.