• Title/Summary/Keyword: membrane system

Search Result 2,409, Processing Time 0.026 seconds

Application of a Membrane Bioreactor in Denitrification of Explosives Hydrolysates (Membrane Bioreactor를 이용한 폭발성 물질의 가수분해 부산물의 탈질과정에의 적용)

  • Zoh, Kyung-Duk
    • Journal of Korean Society on Water Environment
    • /
    • v.18 no.2
    • /
    • pp.113-122
    • /
    • 2002
  • A bench-scale anoxic membrane bioreactor (MBR) system, consisting of a bioreactor coupled to a ceramic crossflow ultrafiltration module, was evaluated to treat a synthetic wastewater containing alkaline hydrolysis byproducts (hydrolysates) of RDX, The wastewater was formulated the same as RDX hydrolysates, and consisted of acetate, formate, formaldehyde as carbon sources and nitrite, nitrate as electron accepters. The MBR system removed 80 to 90% of these carbon sources, and approximately 90% of the stoichiometric amount of nitrate, 60% of nitrite. The reactor was also operated over a range of transmembrane pressures, temperatures, suspended solids concentration, and organic loading rate in order to maximize treatment efficiency and permeate flux. Increasing transmembrane pressure and temperature did not improve membrane flux significantly. Increasing biomass concentration in the bioreactor decreased the permeate flux significantly. The maximum volumetric organic loading rate was $0.72kg\;COD/m^3/day$, and the maximum F/M ratio was 0.50 kg N/kg MLSS/day and 1.82 kg COD/kg MLSS/day. Membrane permeate was clear and essentially free of bacteria, as indicated by heterotrophic plate count. Permeate flux ranged between 0.15 and $2.0m^3/m^2/day$ and was maintained by routine backwashing every 3 to 4 day. Backwashing with 2% NaOCl solution every fourth or fifth backwashing cycle was able to restore membrane flux to its original value.

Investigation of influence of temperature and solid retention time on membrane fouling in MBR

  • Mirzavandi, Atoosa;Hazrati, Hossein;Ebrahimi, Sirous
    • Membrane and Water Treatment
    • /
    • v.10 no.2
    • /
    • pp.179-189
    • /
    • 2019
  • This study aimed to investigate the effect of temperature and solid retention time (SRT) on membrane fouling in a membrane bioreactors (MBRs). For this purpose, a lab-scale submerged MBR system was used. This system operated at two SRTs of 15 and 5 days, three various temperatures (20, 25 and $30^{\circ}C$) and hydraulic retention time (HRT) of 8 h. The results indicated that decreased the cake layer resistance and increased particles size of foulant due to increasing temperature and SRT. Fourier transform infrared (FTIR) analysis show that the cake layer formed on the membrane surface, contained high levels of proteins and especially polysaccharides in extracellular polymeric substances (EPS) but absorbance intensity of EPS functional groups decreased with temperature and SRT. EEM analysis showed that the peak on the range of Ex/Em=220-240/350-400 in SRT of 15 and temperature of $30^{\circ}C$ indicates the presence of fulvic acid in the cake. In addition, as the temperature rise from 20 to $30^{\circ}C$, concentration of soluble microbial products (SMP) increased and COD removal reached 89%. Furthermore, the rate of membrane fouling was found to increase with decreasing temperature and SRT.

A Parametric Study of Pervaporation-facilitated Esterification (전산모델링을 통한 투과증발-촉진 에스테르화 반응에 대한 연구)

  • Yeom, C.K.;Choi, Seung-Hak;Park, You-In;Chang, Sung-Soon
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.146-160
    • /
    • 2007
  • A parametric study on pervaporation-facilitated esterification was performed by using a practical model based on non-perfect separation through membrane which is not perfectly permselective to water. Thus, membrane selectivity as well as membrane capability to remove water should be taken into account in establishing the simulation model to explain how the membrane separation influence the esterification reaction process. It was shown by simulation that in the reaction systems with non-perfect separation, the permeation of reactants which are acid or/and alcohol retards the reaction by inducing the backward reaction so that reaction conversion curve is located between a reaction system coupled with pervaporation process having a perfect permselectivity to water and a reaction system without pervaporation process. The volume change of reaction system occurs as a result of the permeation through the membrane. The reaction volume change which can be characterized by the reaction ratio of $r_{\Psi}\;to\;r_{{\Psi}=1}$ affects reaction kinetics by concentrating reactants and products, respectively, with different extent with time; reactant-concentrating effect is dominant during the initial stage of reaction, resulting in facilitating the reaction, and then product-concentrating effect is exerted more on reaction, causing to slow down the reaction. When pervaporative dehydration is applied to the reaction system plays an important role in the reaction as well. The effect of timing to impose pervaporation on reaction system affected the reaction kinetics in terms of reaction rate and reaction conversion. A relationship was derived to explain membrane unit capacity and reaction parameters that will be used as a design tool to determine membrane unit capacity at a given reaction conditions or reaction parameters at a membrane unit capacity.

Propagating Spiral Waves Obtained in a Catalyst-Immobilized Gel Membrane by the Belousov-Zhabotinsky Reaction System

  • Kim, Bong-Seong;Jo, Eun-Ae;Basavaraja, C.;Huh, Do-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1956-1962
    • /
    • 2010
  • The formation of diverse spiral waves was studied in a polyacrylamide gel membrane with ruthenium(4-vinyl-4'-methyl-2,2'-bipyridine)bis(2,2'-bipyridine)bis(hexafluorophosphate) by a gas-free Belousov-Zhabotinisky (BZ) reaction system containing 1,4-cyclohexanedione (1,4-CHD). The gel membrane was found to be receptive for observing propagating waves since a clearer wave-train is obtained during a long reaction time without any disturbance from the immobilized metal catalyst which can be dissolved into the highly acidic solution of the BZ system. The distinctive waves in the system basically depend on both $BrO_3$ and 1,4-CHD in the initial phase, and are influenced by the intensity of illumination of visible light.

The Effect of Chemical Backwash on Filtration Performance of Batch Membrane Filtration System (회분식 막여과 시스템에서 약품역세가 여과성능에 미치는 영향)

  • Kim, Kwan Yeop;Lee, Eui Jong;Kwon, Jin Sub;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.855-864
    • /
    • 2009
  • The main object of this work was to determine the influence of periodic chemical backwash on filtration resistance in membrane filtration system. In this work Hermia's models were used to investigate the fouling mechanisms involved in the microfiltration of $0.45{\mu}m$ filtered sewage feed. Batch microfiltration experiments were performed at transmembrane pressure 0.4 bar and different feed SCOD concentration (9~67 mgSCOD/L). The results showed that the best fit to experimental data corresponded to the intermediate blocking model followed by the standard and complete blocking model for all the experimental conditions tested. From the simulation results of filtration performance, it was found that in order to maintain sustainable operation of membrane filtration system, irreversible foulant component accumulated continuously on membrane surface and/or pore must be effectively removed. In addition, it was verified that periodic chemical backwash using NaOCl or NaOH effectively improved filtration performance of membrane.

Effect of powder activated carbon replacement on HCPAC-MBR system operation (고농도 분말활성탄 결합 MBR 운전에 대한 활성탄 교체주기의 영향)

  • Lee, Chae-Ha;Kim, Jin-Tae;Lee, Jung-Hyun;Seo, Gyu-Tae;Kim, In S.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.141-148
    • /
    • 2008
  • This study was conducted to evaluate the effect of PAC(Powder Activated Carbon) retention time on stable operation of high concentration powered activated carbon(HCPAC-MBR) in the treatment of secondary domestic wastewater. The pilot scale HCPAC-MBR system was operated at two different SRTs, 25 days and 100 days. The main drawback of HCPAC-MBR system was the rapid increase of trans-membrane pressure. The increase rate of trans-membrane pressure was proportional to SRT value at constant flux. This result seemed to be caused by reduced amount of EPS adsorbed on the PAC in the reactor by decreasing the SRT of the PAC. The particle size of the PAC was also influenced by SRT. The PAC size was decreased as SRT was increased. The change of particle size could be one reason for the change of trans-membrane pressure. The pore volume in the cake-layer formed on the membrane surface became to be increased by reducing SRT, because the cake-layer was highly composed of the PAC. Therefore, increased pore volume might play a role to reduce the trans-membrane pressure. The removal rate of E260 and TOC was also inversely proportional to SRT value.

Development of Hybrid Membrane composed of Organic and Inorganic Polymers for the Desalination of Deep Ocean Water (I) (해양심층수담수화를 위한 유무기계 분리막 개발(1))

  • Kim H.J.;Jung D.H.;Hong Y.K.;Song K.H.
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.7-12
    • /
    • 2004
  • Desalination system of revers osmosis(RO) membrane has been proven to be the most economical not only for the desalination of water containing salts, but also for the concentration of solute. RO membranes were traditionally made of inorganic polymers such. as cellulose acetate(CA), Polyamide(PA). To retain more minerals in deep ocean water, a new hybrid membrane composed of tourmaline film as organic material onto inorganic layer of CA polymer in asymmetric structure was developed for RO membrane process. The performance tests were carried out in the permeability of pure water and the rejection of NaCl solution to evaluate the adaptability for DOW desalination. The results of these basic tests show possibility to apply the new hybrid RO membrane for the desalination with function control.

  • PDF

CONTROL OF CARBON DIOXIDE REMOVAL RATE BY HOLLOW FIBER MEMBRANE CONTACTOR

  • Lee,Yong-Taek;Cho, Ingi;Lim, Hye-Jin;Ahn, Hyo-Seong;Hahm, Moon-Ky;Park, You-In;Lee, Kew-Ho
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1999.07a
    • /
    • pp.48-51
    • /
    • 1999
  • To investigate numerically the removal behavior of carbon dioxide in a hollow fiber membrane contactor, the system controlling equations were developed including the nonlinear reversible reaction terms. The reversible chemical reactions were incorporated in the system controlling equations, resulting in the coupled nonlinear partial differential equations which could describe either the absorption of the desorption of carbon dioxide. The computer program was coded using the Fortran language and run with a personal computer to find out the effects of the system variables: the pressures of absorbed and desorbed gases, the absorbent flow rate, the concentration of potassium carbonate, the fiber diameter and the length.

  • PDF

Thermal Analysis of Insulation System for KC-1 Membrane LNG Tank (KC-1 Membrane LNG 탱크 단열시스템의 열해석에 관한 연구)

  • Hyeon-won, Jeong;Tae-hyun, Kim;Seog-soon, Kim;W.Jaewoo, Shim
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.91-102
    • /
    • 2017
  • Recently, a new type of LNG membrane Tank called the "KC-1 membrane LNG Tank" was developed by KOGAS (Korean Gas Corporation). It is necessary to estimate the temperature distribution of the hull structure and insulation system for this new LNG tank, as well as the BOR (Boil-Off Rate) when exposed to outside temperature conditions to ensure the integrity of the tank structure and limit LNG evaporation, from a safety evaluation point of view. In this study, temperature distribution calculations for the hull structure and insulation system of the KC1 membrane tank were compared by employing four numerical approaches under the IGC condition. Approaches 1-3 studied 2D simulations and approach 4 used a 3D numerical simulation. Approach 1 was calculated by in-house Excel VBA codes and the three other approaches utilized ANSYS Fluent. The BOR of approach 4, the 3D simulation case, for the IGC condition was 0.0986%/day.

Preparation of high-performance nanofiltration membrane with antioxidant properties

  • Yu, Feiyue;Zhang, Qinglei;Pei, Zhiqiang;Li, Xi;Yang, Xuexuan;Lu, Yanbin
    • Membrane and Water Treatment
    • /
    • v.13 no.4
    • /
    • pp.191-199
    • /
    • 2022
  • In industrial production, the development of traditional polyamide nanofiltration (NF) membrane was limited due to its poor oxidation resistance, complex preparation process and high cost. In this study, a composite NF membrane with high flux, high separation performance, high oxidation resistance and simple process preparation was prepared by the method of dilute solution dip coating. And the sulfonated polysulfone was used for dip coating. The results indicated that the concentration of glycerin, the pore size of the based membrane, the composition of the coating solution, and the post-treatment process had important effects on the structure and performance of the composite NF membrane. The composite NF membrane prepared without glycerol protecting based membrane had a low flux, when the concentration of glycerin increased from 5% to 15%, the pure water flux of the composite NF membrane increased from 46.4 LMH to 108.2 LMH, and the salt rejection rate did not change much. By optimizing the coating system, the rejection rate of Na2SO4 and PEG1000 was higher than 90%, the pure water flux was higher than 40 LMH (60psi), and it can withstand 20,000 ppm.h NaClO solution cleaning. When the post treatment processes was adjusted, the salt rejection rate of NaCl solution (250 ppm) reached 45.5%, and the flux reached 62.2 LMH.