Recent advances in radiation transport algorithms, computer hardware performance, and parallel computing make the clinical use of Monte Carlo based dose calculations possible. Monte Carlo treatment planning requires accurate beam information as input to generate accurate dose distributions. The procedures to obtain this accurate beam information are called "commissioning", which includes accelerator head modeling. In this study, we would like to investigate how much accurately Monte Carlo based dose calculations can predict the measured beam data in various conditions. The Siemens 6MV photon beam and the BEAM Monte Carlo code were used. The comparisons including the percentage depth doses and off-axis profiles of open fields and wedges, output factors will be presented.
눈의 수정체는 방사선에 매우 예민한 장기이며 비교적 적은 선량에서도 백내장의 원인이 될 수 있다. 그러므로 두경부암의 방사선치료에서 수정체를 최대한 차폐하면서 병소에 집중 조사하는 방법이 개발되어야 한다. 저자는 안구의 표면에서 0.5 cm 깊이에 위치하며 폭 1 cm인 눈의 수정체를 최대한 차폐하면서 주위 병소를 치료하기 위하여 원자번호가 높은 차폐물질을 이용하였으며 최적조사조건은 측정실험을 통하여 결정하였고 이를 임상치료에 응용하였다. 수정체의 차폐기구는 제작하기 쉽고 차폐효과가 큰 혼합금속(Cerrobend)이 적당하였으며 두께 7.5 cm와 직경 1 cm의 원뿔기둥모양이 가장 이상적이었다. 차폐기둥의 밑면과 표면과의 거리가 l0 cm일 때 수정체에 가장 적은 선량이 부여되며 병소에는 비교적 많은 선량이 부여된다. 이때 각막(Cornea, 1 mm), 수정체 (Eye Lens, 5 mm), 망막(Retina, 25 mm) 및 병소(Tumor, 50 mm 이상)의 선량은 차폐물이 없을 때와 비교하여 각각 $10.0\%$, $15.2\%$, $21.5\%$ 및 $23.2\%$로 측정되었다.
Kim, Seong-Hoon;Huh, Hyun-Do;Choi, Sang-Hyun;Min, Chul-Hee;Shin, Dong-Oh;Choi, Jin-Ho
Journal of Radiation Protection and Research
/
제34권2호
/
pp.43-48
/
2009
When the PDD (percentage depth dose) in the megavoltage beams is measured in the water phantom, the polarity and ion recombination effects of ionization chambers with depth in water are not usually taken into consideration. We try to investigate if those variations with depth should be taken into consideration or could be ignored for the thimble type semiflex ionization chamber (PTW $31010^{TM}$, SN 1551). According to the recommendation of IAEA TRS-398, the 4 representative depths of $d_s$, $d_{max}$, $d_{90}$ and $d_{50}$ were used for the electron beams. For the photon beams, the 4 depths were arbitrarily chosen for the photon beams, which were $d_s$, $d_{max}$, $d_{10}$ and $d_{20}$. For the high energy photon beam both polarity and ion recombination factors of the chamber with depth in water gives the good agreements within the maximum $\pm$0.2%, while the $C_{polS}$ with depth came within the maximum $\pm$ 0.4% and the $C_{IRS}$ within the maximum $\pm$0.6% in every electron beam used. This study shows that PDI (percentage depth ionization) could be a good approximation to PDD for the chamber used.
치료방사선 선형가속기에서 출력되는 광자선의 선속 (flux)에는 gantry head로부터 발생되는 오염전자를 포함하고 있으며, 오염전자의 발생은 주로 gantry head의 부속장비 또는 방사선 치료를 위해 gantry head 밑에 설치되는 부속장치 등에서 광자선과 매질의 전자쌍생성, 또는 컴프톤 산란전자 등의 물리적 현상으로 발생된다. 오염전자는 표면영역의 수cm 깊이의 선량 분포에 영향을 주고 있으며, 이것은 방사선 치료 시 skin-sparing 효과를 감소시키는 등 임상적인 측면에 영향을 주고 있다. 그러므로 선형가속기에서 발생되는 오염전자의 특성을 이해 할 필요가 있다. 본 연구는 선형가속기 (Clinac 1800, Varian )에서 출력되는 15MV 광자 선속에서 조사야의 크기가 0.0$\times$10.0 to 30.0$\times$30.0 $\textrm{cm}^2$에서 30.0$\times$30.0 $\textrm{cm}^2$ 대해 구리판(Cu)의 부분적 오염전자 제거 능력과, 조사야의 부분 차폐 방법을 이용하여 물팬톰 내의 선량분포의 변화를 측정하므로써 오염전자의 특성을 분석하였다. 그 결과 오염전자는 조사야의 중심축으로부터 넓게 퍼진 cone 모양의 분포를 하고 있었으며, 또한 오염전자가 갖는 평균 에너지는 약 3.0MeV로 나타났다. 그러므로 오염전자는 표면으로부터 2.5cm 깊이까지 분포하였다. 이러한 결과로써 광자선속에 포함된 오염전자를 제거하고 순수한 광자선을 이용한다면 buildup 영역 및 표면선량이 감소되고, 최대선량지점이 좀더 깊어진다.
Shamsi, Azin;Birgani, Mohammad Javad Tahmasebi;Behrooz, Mohammad Ali;Arvandi, Sholeh;Fatahiasl, Jafar;Maskny, Reza;Abdalvand, Neda
Asian Pacific Journal of Cancer Prevention
/
제17권1호
/
pp.197-200
/
2016
Background: Wedge filters are commonly used in radiation oncology for eliminating hot spots and creating a uniform dose distribution in optimizing isodose curves in the target volume for clinical aspects. These are some limited standard physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$),or creating an arbitrary wedge angle, like motorized wedge or dynamic wedge,${\ldots}$ The new formulation is presented by the combination of wedge fields for determining an arbitrary effective wedge angles. The isodose curves also are derived for these wedges. Materials and Methods: we performed the dosimetry of Varian Clinac 2100C/D with Scanditronix Wellhofer water blue phantom, CU500E, OmniPro - Accept software and 0.13cc ionization chamber for 6Mv photon beam in depth of 10cm (reference depth) for universal physical wedges ($15^{\circ}$, $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$) and reference field $10.10cm^2$. By combining the isodose curve standard wedge fields with compatible weighting dose for each field, the effective isodose curve is calculated for any wedge angle. Results: The relation between a given effective wedge angle and the weighting of each combining wedge fields was derived. A good agreement was found between the measured and calculated wedge angles and the maximum deviation did not exceed $3^{\circ}$. The difference between the measured and calculated data decreased when the combined wedge angles were closer. The results are in agreement with the motorized single wedge appliance in the literature. Conclusions: This technique showed that the effective wedge angle that is obtained from this method is adequate for clinical applications and the motorized wedge formalism is a special case of this consideration.
방사선조사면의 가장자리는 반음영 영역으로 선량변화가 급격한 부분이다. 이러한 부분은 메가볼트 광자선 영역의 조사면에서 선원크기, 콜리메이터, 차폐불럭, 보조기구 그리고 내부산란선에 의한 것으로 알려져 있다. 본 연구에서는 기준조사면 경계 영역의 선량특성을 확인하고 선험적인 이론적 관계식으로 비교하여 치료시스템 조사면의 특성을 알고자 하였다. 조사면 경계영역의 주변선량분포를 깊이와 중심축으로부터 거리의 함수로서 구성하여 6MV 광자선에 의한 민조사면 경계영역의 주변선량분포를 측정하고 이를 선험적인 함수분포와 비교하였다. 3차원 물 팬톰으로 조사면 가장자리 영역의 주변선량분포를 측정하고 이를 선험적인 함수값과 비교하여 측정치와 근접한 함수방법을 알아보았다. 반도체 검출기와 전리함으로 최대선량점, 5 cm , 10 cm 깊이의 위치에서 측정값의 비를 이용하고, 유효 가장자리 영역은 80-20 % 를 선택하여 거리의 함수로 분석하였다. 깊이가 증가함에 따라경계영역의 선량폭이 증가하였다. 주변선량분포에서 검출기의 특성에 따라서 측정값과 함수값에 작은 차이가 있었다. 민조사면 경계영역 선량 분포함수를 비교하였다.
고에너지 (6-15MV) 광자선속으로 치료할때 LiF(TLD-100) 결정은 solid water phantom 이나 환자의 피부 표면에서의 흡수선량을 측정하기 위해 열자극 발광 선량계(이하 NC-100)가 주로 사용된다. 통상 NC-100은 가열 과정을 여러회 반복하면 그 감도가 줄어드는 것으로 조사되었다. NC-100 위에 입사 광자선속 방향으로 올려놓은 140$\mu\textrm{m}$ 두께의 금박막(이하 GC-100)은 NC-100 과 다른 성질을 갖는다. 즉, 광자선속에서 GC-100 은 금박막에서 주로 쌍생성이 일어나고 부분적으로 Compton 산란이 일어나 많은 양전자와 음전자를 만들어 낸다. 그 결과 TLD-100 결정은 증가된 신호를 갖고(최대 100% 증가), 흡수 선량당 높은 반응도가 좋은 선형도를 갖으며, 선량물에 무관할 뿐만 아니라 Fluctuation error 도 $\pm$0.5% 미만으로 낮게 측정되었다. GC-100 은 주로 쌍생성이 일어나기 때문에 전자선보다 광자선에서 더욱 감도가 좋은것으로 나타난다. 그것은 금과같이 원자번호가 높은 매질에서 광자선에 의한 쌍생성의 확률이 큰것에 기인한다. 치료용 고에너지 광자선속에서 TLD-100 chip 위에 올려진 금박막은 TLD 의 신호를 크게 증가시키는 역할을 하는것으로 나타났다.
방사선 전신 및 반신 조사방법을 방사선치료에 적용하여 균일한 선량 분포를 유도하고자 조사거리에서 선량측정, 조직결손에 따른 보상과 선량 보정 방법을 논의하였다. 의료용 선형가속기에서 발생된 6MV 광자선을 이용한 전신 조사시의 흡수선량을 결정하는, 선원과 조사면사이의 거리 변화에 따른 계산자료를 조사면의 중심축에서 고체 팬톰, RFA-7 물팬톰(Scanditronix, Sweden)에 대해 UNIDOS 전리함(PTW, Germany), THERADOS 전리함(Scanditronix, Sweden)을 이용한 측정으로 그 크기를 결정하였다. 조직보상체는 연판과 아크릴판을 이용하였다. 전신조사의 조건은 선원으로부터 380 cm의 거리에서 120 $\times$ 120 $cm^2$ ~ 152 $\times$ 152 $cm^2$ 의 조사면을 대상으로 하였다. 전신조사를 위한 기본 자료 측정에서 선원과 조사면의 거리 변화에 따른 흡수 선량 분포는 거리가 멀수록 더 증가하는 현상을 보였고, 조사면의 모서리부분은 약 10-20% 의 선량이 감소되었으나 굴곡좌위형 체위를 취함으로서 선량분포를 보완할 수 있었다. 연판과 아크릴판을 이용한 조직결손에 따른 보상체 제작으로 중심축 선량비를 $\pm$ 8% 이내로 감소시킬 수 있었다. 조직결손의 보상에 따른 선량계산을 고찰하여 임상 적용시 선량분포의 불균일성을 줄일 수 있었다.
The secondary electrons developed by interaction between primary beam and a tray mounted for blocks in Megavoltage irradiation result in excess soft radiation dose to the surface layer. To reduce this electron contamination, electron filters have been used to be attached under a tray. Various filters with Cu and Al plates in six different thickness and Cu/Al combined plates in 3 different thickness were tested to measure the reduction rate of secondary electron contamination to the surface layer. The measurement to find optimal filter was performed on 6MV linear accelerator in $10 cm{\times}10 cm$ field size and fixed 78.5cm source to measurement points distance from surface to maximum build up point in 2mm intervals. The result was analyzed as the ratio of measured doses with using filters, to standard doses of measured open beam. The result of this study was fellowing : 1. The contaminated low energy radiation were mainly produced by blocking tray. 2. The surface absorbed dose was slowly increased by increasing irradiation field size but rapidly increased at field size above $15cm{\times}15cm$. 3. Al plate upto 2.5mm thickness used as a filter was found to be inadequate due to the failure of reduction of the surface absorbed dose below doses of the under surface upto the maximal build up. Cu 0.5mm plate and Cu 0.28mm/A1 1.5mm compound plate were found to be optimal filters. 4. By using these 2 filters, the absorbed dose to the surface were effectively reduced $5.5\%$ in field size $4cm{\times}4cm,\;11.3\%$ in field size $10cm{\times}10cm,\;22.3\%$ in field size $25cm{\times}25cm$. 5. In field size $10cm{\times}10cm$, the absorbed dose to the surface of irradiation was reduced by setting TSD 20cm at least,. but effective and enough dose reduction could be achieved by setting TSD 30cm as 2 optimal filters used. 6. More surface dose absorbed at TSD less than 7.4cm with a tray and filters together indicated that soft radiation was also developed by filters. 7. The variation of PDD by the different size of irradiation field was minimal as 2 optimal filters used. There was also not different in variation of PDD according to using any of two different filters. 8. PDD was not effected either by various TSD or by using the different filter among two.
Kim, Sung-woo;Cho, Byungchul;Cho, Sangeun;Im, Hyunsik;Hwang, Ui-jung;Lim, Young Kyoung;Cha, SeungNam;Jeong, Chiyoung;Song, Si Yeol;Lee, Sang-wook;Kwak, Jungwon
한국의학물리학회지:의학물리
/
제28권4호
/
pp.226-231
/
2017
The aim is to investigate the spectra responsibilities of QD (Quantum Dot) for the innovation of new dosimetry application for therapeutic Megavoltage X-ray range. The unique electrical and optical properties of QD are expected to make it a good sensing material for dosimeter. This study shows the spectra responsibility of toluene based ZnCd QD and PPO (2.5-diphenyloxazol) mixed liquid scintillator. The QDs of 4 sizes corresponding to an emission wavelength (ZnCdSe/ZnS:$440{\pm}5nm$, ZnCdSeS:470, 500, $570{\pm}5nm$) were utilized. A liquid scintillator for control sample was made of toluene, PPO. The Composition of QD loaded scintillators are about 99 wt% Toluene as solvent, 1 wt% of PPO as primary scintillator and 0.05, 0.1, 0.2 and 0.4 wt% of QDs as solute. For the spectra responsibility of QD scintillation, they were irradiated for 30 second with 6 MV beam from a LINAC ($Infinity^{TM}$, Elekta). With the guidance of 1.0 mm core diameter optical fiber, scintillation spectrums were measured by a compact CCD spectrometer which could measure 200~1,000 nm wavelength range (CCS200, Thorlabs). We measured the spectra responsibilities of QD loaded organic liquid scintillators in two scintillation mechanisms. First was the direct transfer and second was using wave shifter. The emission peaks from the direct transfer were measured to be much smaller luminescent intensity than based on the wavelength shift from the PPO to QDs. The emission peak was shifted from PPO emission wavelength 380 nm to each emission wavelength of loaded QD. In both mechanisms, 500 nm QD loaded samples were observed to radiate in the highest luminescence intensity. We observed the spectra responsibility of QD doped toluene based liquid scintillator in order to innovate QD dosimetry applicator. The liquid scintillator loading 0.2 wt% of 500 nm emission wavelength QD has most superior responsibility at 6 MV photon beam. In this study we observed the spectra responsibilities for therapeutic X-ray range. It would be the first step of innovating new radiation dosimetric methods for radiation treatment.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.