• Title/Summary/Keyword: medium operating temperature

Search Result 75, Processing Time 0.029 seconds

A Study on Performance and Reactor Behavior of Chemical Refrigerator (화학식 냉동기의 성능 및 반응기 거동에 관한 연구)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-95
    • /
    • 1997
  • A chemical heat pump based on the reversible reactions between metal chlorides and ammonia gas is attractive alternative to compression system and liquid absorption systems in cooling and refrigerating fields. The advantages of chemical heat pump are no regulatory constants due to CFC refrigerants, utilization of gas, industrial waste heat, electricity, fuel oil etc. as heat sources and wide applications to energy storage system, large-scale energy managements for industrial process. The scale-up of chemical heat pump from laboratory prototype to pilot plants necessitates the interpretation of system performance and evaluation of dynamic behavior in the chemical reactor. This study contains the prediction of performance of chemical refrigerator according to operating condition, the dynamic simulations through reactor modelling, which is used for the calculation of reactive medium temperature and the conversion variation with reactor cooling temperature, and the effect survey of block parameters on the power of refrigerator.

  • PDF

Case study on operating characteristics of gas fueled ship under the conditions of load variation

  • Chun, Jung-Min;Kang, Ho-Keun;Kim, You-Taek;Jung, Mun-Hwa;Cho, Kwon-Hae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.447-452
    • /
    • 2016
  • The use of gas as fuel, particularly liquefied natural gas (LNG), has increased in recent years owing to its lower sulfur and particulate emissions compared to fuel oil or marine diesel oil. LNG is a low temperature, volatile fuel with very low flash point. The major challenges of using LNG are related to fuel bunkering, storing, and handling during ship operation. The main components of an LNG fuel system are the bunkering equipment, fuel tanks, vaporizers/heaters, pressure build-up units (PBUs), and gas controlling units. Low-pressure dual-fuel (DF) engines are predominant in small LNG-powered vessels and have been operating in many small- and medium-sized ferries or LNG-fueled generators.(Tamura, K., 2010; Esoy, V., 2011[1][2]) Small ships sailing at coast or offshore rarely have continuous operation at constant engine load in contrast to large ships sailing in the ocean. This is because ship operators need to change the engine load frequently due to various obstacles and narrow channels. Therefore, controlling the overall system performance of a gas supply system during transient operations and decision of bunkering time under a very poor infrastructure condition is crucial. In this study, we analyzed the fuel consumption, the system stability, and the dynamic characteristics in supplying fuel gas for operating conditions with frequent engine load changes using a commercial analysis program. For the model ship, we selected the 'Econuri', Asia's first LNG-powered vessel, which is now in operation at Incheon Port of South Korea.

The Study of the Integrated Technology of the Dual Fluidized-bed Gasification for Producing Medium Heating Value Syngas (중발열량 합성가스 생산을 위한 일체형 이중유동층 가스화 기술 연구)

  • Choi, Jae-Myeong;Kim, Jae-Min;Kim, Sung-Hyun;Son, Yang-Seung;Lee, Dong-Min;Choi, Jin-Hoon;Park, Sung-Youl;Kim, Seong-Soo
    • Clean Technology
    • /
    • v.19 no.3
    • /
    • pp.226-232
    • /
    • 2013
  • A 5 kg/hr scale integral dual fluidized-bed gasifier for producing medium heating value syngas from biomass or combustible wastes was manufactured. The effect of operating variables including gasification temperature, rate of feeding, and weight ratio of steam/feed on the behavior of the gasifier was investigated. The contents of $H_2$ and CO in syngas, flow rate of feeding, cold gas efficiency increased with the increased gasification temperature or rate of feeding, but decreased with the increased weight ratio of steam/feed within the experimental range. With wood powder as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 41% and 32%, and the cold gas efficiency and lower heating value of the syngas were as high as 70.1% and $3,428kcal/Nm^3$. With food wastes as the feed, the concentrations of $H_2$ and CO in the syngas were as high as 37% and 23.9%, and the cold gas efficiency and lower heating value of the syngas were as high as 66.7% and $3,670kcal/Nm^3$.

PID Control of a Shell and Tube Heat Exchanger System Incorporating Feedforward Control and Anti-windup Techniques (피드포워드 제어와 안티와인드업 기법을 결합한 셀-튜브 열교환기 시스템의 PID 제어)

  • Ahn, Jong-Kap;So, Gun-Baek;Lee, Ju-Yeon;Lee, Yun-Hyung;So, Myong-Ok;Jin, Gang-Gyoo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.543-550
    • /
    • 2014
  • In many industrial processes and operations, such as power plants, petrochemical industries and ships, shell and tube heat exchangers are widely used and probably applicable for a wide range of operating temperatures. The main purpose of a heat exchanger is to transfer heat between two or more medium with temperature differences. Heat exchangers are highly nonlinear, time-varying and show time lag behavior during operation. The temperature control of such processes has been challenging for control engineers and a variety of forms of PID controllers have been proposed to guarantee better performance. In this paper, a scheme to control the outlet temperature of a shell and tube heat exchanger system that combines the PID controller with feedforward control and anti-windup techniques is presented. A genetic algorithm is used to tune the parameters of the PID controller with anti-windup and the feedforward controller by minimizing the IAE (Integral of Absolute Error). Simulation works are performed to study the performance of the proposed method when applied to the process.

Creep Damage Evaluation of Cr-Mo Steel High-Temperature Pipeline Material for Fossil Power Plant Using Ultrasonic Test Method (초음파법을 이용한 Cr-Mo강 고온배관재료의 크리프손상 평가)

  • Lee, Sang-Guk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.1
    • /
    • pp.18-26
    • /
    • 2000
  • Boiler high-temperature pipelines such as main steam pipe, header and steam drum in fossil power plants are degraded by creep damage due to severe operating conditions such as high temperature and high pressure for an extended period time. Conventional measurement techniques(replica method, electric resistance method, and hardness test method) for measuring creep damage have such disadvantages as complex preparation and measurement procedures, too many control parameters. And also these techniques have low practicality and applied only to component surfaces with good accessibility. In this paper, artificial creep degradation test and ultrasonic measurement for their creep degraded specimens(Cr-Mo alloy steels) were carried out for the purpose of evaluation for creep damage. Absolute measuring method of quantitative ultrasonic measurement for material degradation was established, and long term creep degradation tests using life prediction formula were carried out. As a result of ultrasonic tests for crept specimens. we conformed that both the sound velocity decreased and attenuation coefficient linearly increased in proportion to the Increase of creep life fraction($\Phi$c).

  • PDF

Preparation and Characterization of Nafion Composite Membranes Containing 1-ethyl-3-methylimidazolium Tetracyanoborate

  • Shin, Mun-Sik;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • The composite membranes using Nafion as matrix and 1-ethyl-3-methylimidazolium tetracyanoborate (EMITCB) as ion-conducting medium in replacement of water were prepared and characterized. The amount of EMITCB in Nafion varied from 30 to 50wt%. The composite membranes are characterized by ion conductivity, thermogravitational analyses (TGA) and small-angle X-ray scattering (SAXS). The composite membranes containing EMITCB of 40wt% showed the maximum ionic conductivity which was ~0.0146 S $cm^{-1}$ at 423.15 K. It is inferred that the decrease in ionic conductivity of all the composite membranes might be due to the decomposition of a tetracyanoboric acid formed in the composite membranes. The results of SAXS indicated that the ionic clusters to conduct proton in the composite membranes were successfully formed. In accordance with the results of ionic conductivity as a function of a reciprocal temperature, SAXS showed a proportional decrease in scattering maximum $q_{max}$ as the amount of EMITCB increases in the composite membranes, which results in the increase in ionomer cluster size. The TGA showed no significant decomposition of the ionic liquid as well as the composite membranes in the range of operating temperature ($120-150^{\circ}C$) of high temperature proton exchange membrane fuel cells (HTPEMFC). As a result, EMITCB is able to play an important role in transferring proton in the composite membranes at elevated temperatures with no external humidification for proton exchange membrane fuel cells.

The Time Series Analysis of Standards and Results of Nutritional Domain in Hospital Evaluation Program (의료기관 평가제도 영양부문 기준 및 결과의 시계열 변화 분석)

  • Lee, Joo-Eun
    • Journal of the Korean Dietetic Association
    • /
    • v.19 no.4
    • /
    • pp.317-342
    • /
    • 2013
  • The purpose of this study was to evaluate the current state of foodservice and clinical nutrition management in a hospital-based nutrition department. Nutritional guidelines and survey reports of hospital evaluation programs from 2004 to 2009 were analyzed. In total, 275 hospitals in the first period and 288 hospitals in the second period were evaluated. The division of knife and chopping board use decreased from 97.2% in 2005 to 89.7% in 2008, the maintenance of a proper freezer temperature (below $-18^{\circ}C$) increased from 82.1% in 2004 to 97.7% in 2007 (88.9% to 97.4% from large hospitals and 69.8% to 86.5% from small/medium hospitals in 2005 and 2008, respectively). In tube-feeding management, the performance rate of material cold storage and the offer rate of tube-feeding were 65.9% and 94.2% in 2007, respectively. The cold storage of material, proper use within 24 hours after opening or production, and the use of an appropriate label were 47.3%, 71.2% and 67.2% in 2009, respectively. The rate of a management system for undernourished patients was 86.0% in 2007 (56.4% for large hospitals, 18.9% for small/medium hospitals) and 14.3% in 2009. In standards of nutrition support management, the performance rates of constructing a nutrition support team, the nutrition support team activity, and organizing multidisciplinary team were 66.7%, 43.6%, and 64.1% respectively, in 2004. For large hospitals, those rates were 61.1%, 36.1%, and 58.3%, in 2005, 93.0%, 62.8%, and 91.9% in 2007, and 69.2%, 43.6%, and 69.2% in 2008, respectively. The results of this study suggest standards on sanitary foodservice preparation, production, and tube-feeding production need to correspond with HACCP regulations for small/meidium hospitals in standards of a healthcare accreditation system. It will be necessary to understand the operating conditions of nutrition departments in convalescent hospitals, psychiatric hospitals, and geriatrics hospitals. As the application of accreditation is required from 2013, standards will need to be improved and continuously updated for healthcare accreditation.

Operating Characteristics of LED Package Heat-sink with Multi-Pin's (멀티-핀을 갖는 LED 패키지 방열장치의 동작특성)

  • Choi, Hoon;Han, Sang-Bo;Park, Jae-Youn
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.1-12
    • /
    • 2014
  • This paper is proposed to design the new heat-sink apparatus for improving the heat transfer characteristics in the power LED chip, and results of the operation characteristics were discussed. The core design is that the soldering through-hole on the FR-4 PCB board is formed to the effective heat transfer. That is directly filled with Ag-nano materials, which shows the high thermal conductivity. The heat transfer medium consisting of Ag-nano materials is classified into two structures. Mediums are called as the heat slug and the multi-pin in this work. The heat of the high temperature generated from the LED chip was directly transferred to the heat slug of the one large size. And the accumulated heat from the heat slug was quickly dissipated by the medium of the multi-pin, which is the same body with the heat slug. This multi-pin was designed for the multi-dissipation of heat by increasing the surface areas with a little pins. Subsequently, the speed of the heat transfer with this new heat-sink apparatus is three times faster than the conventional heat-sink. Therefore, the efficiency of the illuminating light will be improved by adapting this new heat-sink apparatus in the large area's LED.

Estimation of Phase Variance of Acoustic Signals Depending on Turbulence Strength Near the Mukho Port in the East Sea of Korea (동해 묵호항 근처에서의 난류세기인자에 따른 음향수신신호의 위상분산 추정)

  • Kim, Jung-Hun;Bok, Tae-Hoon;Paeng, Dong-Guk;Shim, Tae-Bo;Kim, Young-Kyu;Park, Joung-Soo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.328-335
    • /
    • 2009
  • Phase variance of the acoustic signals has to be investigated with the research of the medium, because the phase of the acoustic signals carries the information of the medium. The phase compensation of the received signals is required for the signal processing of SAS (Synthetic Aperture Sonar) and underwater communication. In this paper, the phase variance of the acoustic signals was studied depending on the micro-scale-turbulence of ocean. The turbulence strength of the locally isotropic and homogeneous turbulence was calculated, and the phase variance affected by the turbulence strength was computed along the ray paths. The CTD and ADCP data were acquired from a buoy system near the Mukho port in the East Sea of Korea and the ray paths were calculated by the Bellhop algorithm. As a result, the turbulence strength was mainly determined by the variation of temperature and flow speed, changing the phase variance of the received signals. Hence, we thought the phase variance should be considered in the sonar operating system.

Temperature Distribution in Water Cascading Horizontal Retort (열수식 살균기의 온도 분포에 관한 연구)

  • Chung, Myong-Soo;Ahn, Tae-Hoe;Lee, Yong-Gab;Yoo, Moo-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.6
    • /
    • pp.827-833
    • /
    • 1995
  • Temperature distribution tests for a water cascading horizontal retort utilizing superheated water with overpressure as a heating medium were carried out under three different loading conditions, that is, empty(P-0), half-fully(P-3000) and fully(P-6000) loaded operating conditions. Tank volume and full loading capacity of sterilizer used for this study were about 5,900 liter and 1,140 kg(6000 pouches having 190 g weight each), respectively. Set point condition for sterilization was $122^{\circ}C$, 23 minutes and pressure was maintained in the range of $1.8{\sim}2.0\;kg/cm^2$ during sterilization. For each experiment, time-temperature data and F values were obtained from temperature microprocessor($F_0$ monitor). There were significant variations in the temperature distribution at different positions in the sterilizer. The temperature distribution was also affected by the pouch loading condition significantly. The application of the temperature distribution test to a product (retort pouched curry sauce) was conducted at the fully(P-6000) loading condition. Although heat transfer parameters($f_h\;and\;f_c$), and F values were varied with the position of sterilizer, sensory evaluation showed that the temperature distribution of the sterilizer used in this study didn't affect the quality of retorted curry sauce.

  • PDF