• Title/Summary/Keyword: medical exchange

Search Result 396, Processing Time 0.029 seconds

Using FHIR, ECG Automatic notification Research (FHIR를 이용한 심전도 자동 노티 연구)

  • Lee, Jean-hyoung;Park, Dae-woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.344-346
    • /
    • 2016
  • FHIR is a protocol that enables easy data exchange from the time the event occurred in health care settings as a standard for next-generation message exchange of HL7. Create a meaningful message from the ECG and medical equipment, and express the messages generated by standardized FHIR message it will be used in various medical institutions to ensure delivery to EMR, such as hospital information systems can query the results via a smartphone. In addition, it thought to be used in the future to expand SMART on FHIR, Cardiology, Cardiovascular Surgery ward in real-time remote monitoring.

  • PDF

Acquisition and Interpretation Guidelines of Breast Diffusion-Weighted MRI (DW-MRI): Breast Imaging Study Group of Korean Society of Magnetic Resonance in Medicine Recommendations

  • Kang, Bong Joo;Kim, Min Jung;Shin, Hee Jung;Moon, Woo Kyung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.2
    • /
    • pp.83-95
    • /
    • 2022
  • The purpose of this study was to establish and provide guidelines for the standardized acquisition and interpretation of diffusion-weighted magnetic resonance imaging (DW-MRI) to improve the image quality and reduce the variability of the results interpretation. The standardized protocol includes the use of high-resolution DW-MRI with advanced techniques and post-processing. The aim of the protocol is to increase the effectiveness of the medical image information exchange involved in the construction, activation, and exchange of clinical information for healthcare use. An organized interpretation form could make DW-MRIs' interpretation easier and more familiar. Herein, the authors briefly review the basic principles, optimized image acquisition, standardized interpretation guidelines, false negative and false positive cases of DW-MRI, and provide a standard interpretation form and examples of various cases to help users become more familiar with the DW-MRI.

[$Na^+-Ca^{2+}$ Exchange Curtails $Ca^{2+}$before Its Diffusion to Global $Ca^{2+}{_i}$ in the Rat Ventricular Myocyte

  • Ahn, Sung-Wan;Ko, Chang-Mann
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.2
    • /
    • pp.95-101
    • /
    • 2005
  • In the heart, $Na^{+}-Ca^{2+}$ exchange (NCX) is the major $Ca^{2+}$ extrusion mechanism. NCX has been considered as a relaxation mechanism, as it reduces global $[Ca^{2+}]_i$ raised during activation. However, if NCX locates in the close proximity to the ryanodine receptor, then NCX would curtail $Ca^{2+}$ before its diffusion to global $Ca^{2+}_i$ This will result in a global $[Ca^{2+}]_i$ decrease especially during its ascending phase rather than descending phase. Therefore, NCX would decrease the myocardial contractility rather than inducing relaxation in the heart. This possibility was examined in this study by comparing NCX-induced extrusion of $Ca^{2+}$ after its release from SR in the presence and absence of global $Ca^{2+}_i$ transient in the isolated single rat ventricular myocytes by using patch-clamp technique in a whole-cell configuration. Global $Ca^{2+}_i$ transient was controlled by an internal dialysis with different concentrations of BAPTA added in the pipette. During stimulation with a ramp pulse from +100 mV to -100 mV for 200 ms, global $Ca^{2+}_i$ transient was suppressed only mildly, and completely at 1 mmol/L, and 10 mmol/L BAPTA, respectively. In these situations, ryanodine-sensitive inward NCX current was compared using $100{\mu}mol/L$ ryanodine, $Na^+$ depletion, 5 mmol/L $NaCl_2$ and $1{\mu}mol/L$ nifedipine. Surprisingly, the result showed that the ryanodine-sensitive inward NCX current was well preserved after 10 mmol/L BAPTA to 91 % of that obtained after 1 mmol/L BAPTA. From this result, it is concluded that most of the NCX-induced $Ca^{2+}$ extrusion occurs before the $Ca^{2+}$ diffuses to global $Ca^{2+})i$ in the rat ventricular myocyte.

A Secure Key Exchange Protocol Using Smart Devices for U-healthcare Services (U-헬스케어 서비스에서 스마트 기기들을 활용한 안전한 키 교환 프로토콜)

  • Park, Sullha;Seo, Seung-Hyun;Lee, Sang-Ho
    • Journal of KIISE
    • /
    • v.44 no.3
    • /
    • pp.323-331
    • /
    • 2017
  • Due to the recent developments of various smart devices, U-healthcare services using these appliances has increased. However, the security of U-healthcare services is a very important issue since healthcare services contain highly sensitive and private personal health information. In order to handle the security issues, the functionality of encrypting medical information must be provided, and an encryption key exchange method is necessary. In this paper, we propose a key exchange protocol by utilizing smart devices for secure U-healthcare services. The proposed protocol has been designed based on the elliptic curve based public key cryptography, providing high level security for smart devices by using short keys. Moreover, in order to strengthen user authentication and security, a smart watch is used as a complementary device, whenever the key exchange protocol is performed.

Stoichiometry of $Ns^+/Ca^{2+}$ Exchange Quantified with Ion-selective Microelectrodes in Giant Excised Cardiac Membrane Patches

  • kang, Tong Mook;Hilgemann, Donald W.
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 2003.06a
    • /
    • pp.30-30
    • /
    • 2003
  • Without a definitive resolution of stoichiometry of cardiac Na$^{+}$-Ca$^{2+}$exchange (NCX), we cannot proceed to any quantitative analysis of exchange function as well as cardiac excitation-contraction coupling. The stoichiometry of cardiac NCX, however, is presently in doubt because reversal potentials determined by various groups range between those expected for a 3-to-1 and a 4-to-1 flux coupling. For a new perspective on this problem, we have used ion-selective microelectrodes to quantify directly exchanger-mediated fluxes of $Ca^{2+}$and Na$^{+}$in giant membrane patches. $Ca^{2+}$- and Na$^{+}$-selective microelectrodes, fabricated from quartz capillaries, are placed inside of the patch pipettes to detect extracellular ion transients associated with exchange activity. Ion changes are monitored at various distances from the membrane, and the absolute ion fluxes through NCX are determined via simulations of ion diffusion and compared with standard ion fluxes (Ca$^{2+}$ fluxes mediated by $Ca^{2+}$ ionophore, and Na$^{+}$ fluxes through gramicidin channels and Na$^{+}$/K$^{+}$pumps). Both guinea pig myocytes and NCX1-expressing BHK cells were employed, and for both systems the calculated stoichiometries for inward and outward exchange currents range between 3.2- and 3.4-to-1. The coupling ratios do not change significantly when currents are varied by changing cytoplasmic [Ca$^{2+}$] or by adding cytoplasmic Na$^{+}$. The exchanger reversal potentials, measured in both systems under several ionic conditions, range from 3.1- to 3.3-to-1. Taken together, a clear discrepancy from a NCX stoichiometry of 3-to-1 was obtained. Further definitive experiments are required to acquire a fixed number, and the present working hypothesis is that NCX current has an extra current via ‘conduction mode’.ent via ‘conduction mode’.

  • PDF

Public Acceptance of a Health Information Exchange in Korea

  • Park, Hayoung;Park, Jong Son;Lee, Hye Rin;Kim, Soomin
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.359-370
    • /
    • 2018
  • Objectives: We assessed the public acceptance of a health information exchange (HIE) and examined factors that influenced the acceptance and associations among constructs of the Technology Acceptance Model (TAM). Methods: We collected data from a survey of 1,000 individuals in Korea, which was administered through a structured questionnaire. We assessed the validity and reliability of the survey instrument with exploratory factor analysis and Cronbach's alpha coefficients. We computed descriptive statistics to assess the acceptance and performed regression analyses with a structural equation model to estimate the magnitude and significance of influences among constructs of TAM. Results: Eighty-seven percent of the respondents were willing to use the technology, and the average level of agreement with the need for the technology was 4.16 on a 5-point Likert scale. The perception of ease of use of the technology significantly influenced perceptions of usefulness and attitudes about the need for HIE. Perceptions of usefulness influenced attitude and behavioral intention to use HIE, and attitude influenced intention. Age showed a wide range of influences throughout the model, and experience with offline-based information exchange and health status also showed noteworthy influences. Conclusions: The public acceptance of HIE was high, and influences posited by TAM were mostly confirmed by the study results. The study findings indicated a need for an education and communication strategy tailored by population age, health status, and prior experience with offline-based exchange to gain public buy-in for a successful introduction of the technology.

A Case of Multiple Pulmonary Arteriovenous Malformation Treated with Coil Embolization (코일 색전술로 치료된 다발성 폐동정맥기형 1 예)

  • Ahn, Heok-Soo;Lee, Heung-Bum;Lee, Yang-Chul;Rhee, Yang-Keun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.4
    • /
    • pp.896-901
    • /
    • 1998
  • Pulmonary arteriovenous malformation(PAVM) is an uncommon congenital anomaly. As pulmonary arteriovenous malformation is a direct communication between the branches of pulmonary artery and vein which originated from the malformation of capillary development, major disturbances in gas exchange can result. This malformation results in the several symptoms such as dyspnea, hemopyssis, cyanosis, and severe neurologic complaints. However, the most of patients are usually asymptomatic. Selective pulmonary angiography is well known the helpful diagnostic method. Recently, therapeutic embolization has been advocated as the treatment of choice for pulmonary arteriovenous malformations. We report a case of multiple pulmonary arteriovenous malformation, which was detected on the simple chest X-ray and successfully treated with coil embolization in a 19-year-old asymptomatic woman.

  • PDF

A Study of Medical Record about Delegation Dispatched to Japan in Chosun Dynasty (조선통신사 사행원과 기록 연구 -18세기 사행록과 의학문답 기록을 중심으로-)

  • Ham, Jeong Sik;Cha, Wung Seok;Yoo, Won Joon;Kim, Nam Il
    • The Journal of Korean Medical History
    • /
    • v.20 no.1
    • /
    • pp.41-61
    • /
    • 2007
  • In 1607 a delegation was dispatched from Chosun to Japan (under the condition that prisoners of war were returned) to restore the destroyed relationship between the nations due to a war and to restore economic profits. This delegation later on became a delegation representing faith in each other. It contributed greatly to the Korea-Japan cultural exchanges in the 17th and 18th centuries. It was also a cornerstone for the exchange of Korea's distinguished studies as well as medical technology and Japan's results of international trade such as sweet potatoes, pepper, and tobacco. This thesis is one that discusses the study of documents produced during this process.

  • PDF

Idiopathic severe hypermagnesemia in an extremely low birth weight infant on the first day of life

  • Hyun, Hye-Sun;Choi, Hyun-Sin;Kim, Jin-Kyu;Ahn, So-Yoon;Yoo, Hey-Soo;Kim, Eun-Sun;Chang, Yun-Sil;Park, Won-Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.7
    • /
    • pp.310-312
    • /
    • 2011
  • A preterm female infant born at 27 weeks of gestation with a birth weight of 990 g developed acute hypotonia, apnea, hypotension and bradycardia mimicking septic shock syndrome at 14h after birth. Laboratory tests indicated a severe hypermagnesemia of 45 mg/dL. The renal function, complete blood count and maternal blood concentrations of magnesium were normal, and the blood cultures were negative. The patient recovered with treatment including exchange transfusion. However, the etiology of the severe hypermagnesemia remains unknown.

Design of Integrated Medical Information System based on XML (XML 기반 통합의료정보 시스템의 설계)

  • Lim, Chae-Gyun;Rho, Kyung-Taeg
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.167-172
    • /
    • 2010
  • Recently most of hospitals progress toward setting up computer based medical information system, and there exists medical standard such as HL7 and DICOM to exchange efficiently between systems each other. However, Heterogeneous system built in each hospital gets a different data structure of medical information for patient and also makes it difficult to share information among hospitals. This paper proposes an integrated medical information system which changes existing diverse types of medical information to a unified structure and combines into one management model using XML from hospital specific medical information system. Thus, our proposed system makes it possible to get an effectively information share across hospitals without considering the internal system structure of other hospital. As a result, Hospitals provide a efficient and correct diagnosis, saving time and cost to patients.