• 제목/요약/키워드: medical development

검색결과 8,875건 처리시간 0.043초

인공발목관절의 표면 마모 특성 (Surface Tribology of Total Ankle Joint Replacement)

  • Jeong, Yong-Hoon;Jung, Tae-Gon;Yang, Jae-Woong;Park, Kwang-Min;Lee, Su-Won
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2016년도 추계학술대회 논문집
    • /
    • pp.117-117
    • /
    • 2016
  • Total ankle replacement (TAR) is a visible option in the surgical treatment of degenerative or inflammatory diseases of ankle joint. it is attributed to the current TAR which has improvements in surgical technique, uncemented implant fixation and minimally constrained articulation. In the clinical result, they can show promised surgical result when compared to earlier attempts in TAR. However, TAR is still not as successful as total knee replacement (TKR) or total hip replacement (THR), it needs to be note that there are limitations in concerning of long term performance of TAR, the high failure rate still associated with wear of the PE (polyethylene) component that has related with their material property and surface roughness. The aim of this study was to introduce the tribology characteristics of total ankle joint prosthesis with one of TDR model which was fabricated to try multi-axis wear test as a region of motion in ankle joint. The wear specimen of TDR was prepared with Ti-6Al-4V alloy and UHMWPE (ultra-high molecular weight polyethylene) for tibia-talus and bearing component, respectively. A wear test was carried out using a Force 5 (AMTI, Massachusetts, US) wear simulator which can be allowed to move in three axis to flexion-extension ($+3^{\circ}{\sim}-6^{\circ}$), internal-external axial rotation (${\pm}5^{\circ}$), as well as sinusoidal compressive load (1.6 kN, R=10). All tests were performed following standard ISO 14243, wear rate was calculated with weight loss of UHMWPE bearing while the specimen has tested at certain cycles. As based on the preliminary results, wear rate of UHMWPE bearing was $7.9{\times}10^{-6}mg/cycles$ ($R^2=0.86$), calculated loss weight until $10^7cycles$ was 79 mg, respectively.

  • PDF

Risk factors for canine magnesium ammonium phosphate urolithiasis associated with bacterial infection

  • Uttamamul, Nahathai;Jitpean, Supranee;Lulitanond, Aroonlug;Wonglakorn, Lumyai;Sae-ung, Nattaya;Boonsiri, Patcharee;Daduang, Jureerut;Tavichakorntrakool, Ratree
    • Journal of Veterinary Science
    • /
    • 제23권1호
    • /
    • pp.6.1-6.8
    • /
    • 2022
  • Background: With limited information available, the association among urinary tract infections, urease-producing bacteria and the presence of magnesium ammonium phosphate (MAP) urolithiasis in canines in Thailand requires more study. Objectives: This study aimed to investigate the association between demographic characteristics of canines and the presence of MAP urolithiasis in canines, and to evaluate antimicrobial susceptibility patterns of bacteria isolated from canine uroliths. Methods: A total of 56 canines admitted for treatment with surgical removal of uroliths were recruited. Demographic characteristics and clinical chemistry data were recorded. Bacteria isolated from the removed uroliths were identified. Chemical compositions of the uroliths were analyzed by Fourier transform infrared spectrometer. Potential risk factors were determined with univariable and multivariable logistic regression analyses. Results: Of 56 canine urolithiasis, bacteria were isolated from uroliths of 38 canines (27 MAP and 11 non-MAP) but not from uroliths of 18 canines (5 MAP and 13 non-MAP). The most common bacteria found in nidus of MAP uroliths was Staphylococcus pseudintermedius (approximately 51%). An antimicrobial resistance was frequently found in Staphylococci isolates (42.86%). Multivariate logistic regression analysis showed that the predictors of MAP urolith in canine urolithiasis were being female (p = 0.044; adjusted odds ratio [OR], 10.22; 95% confidence interval [CI], 1.06-98.24) and the positive urolith culture (p = 0.012; adjusted OR, 8.60; 95% CI, 1.60-46.30). Conclusions: Our results indicate that S. pseudintermedius (a urease-producing bacterium) is the major causative bacteria of MAP uroliths. A positive urolith culture and being female are risk factors of MAP urolithiasis in canines.

비이식형 요실금 치료용 신경근 전기자극 의료기기 개발 (The Development of Neuromuscular Electrical Stimulation Medical Devices for The Treatment of Non-implantable Urinary Incontinence)

  • 이재용;이창두;권기진
    • 전기학회논문지P
    • /
    • 제64권3호
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, the neuromuscular electrical stimulation medical devices for non-implantable incontinence treatment other than vaginal insertion type was developed and commercialized. The structure of medical devices for electrical stimulation based on the anatomy of the pelvic floor muscle designed. Then, the optimum parameters that may be effective in pelvic floor muscle electrical stimulation was set. The circuit system based on the optimum parameters were designed and manufactured. The frequency of the pulse voltage for electrical stimulation is 75[Hz], the pulse width is 300[${\mu}s$], the development of medical devices was to have seven program functions to the various treatments. The circuit system of medical devices was composed of microcontroller, comparator and converter. The performance of the developed circuit system in KTC(Korea Testing Certification) were carried out medical equipment inspection test. Test results, test specifications were satisfied with the medical device, the performance was verified to be commercialized as a medical device. The development of medical devices were validated risk assessment and product performance through a software validation. Commercialization of medical equipment was acquired to enable the certification standards of the international standard IEC 60601-1.

정보기술을 활용한 의학교육시스템의 설계와 개발: 부산대학교 의학전문대학원 사례 (Design and Development of a Medical Education System Using Information Technology: A Case Report from the Pusan National University School of Medicine)

  • 임선주;이상엽;백선용;우재석;감비성
    • 의학교육논단
    • /
    • 제16권1호
    • /
    • pp.16-24
    • /
    • 2014
  • The development of information technology (IT) has led to changes in medical education. IT has been used for e-learning and e-teaching, e-assessment, e-logistics, and e-administration. Pusan National University School of Medicine has developed its own educational information system using IT to support students' learning and assessment and to manage curricular activities. Based on our experience, we propose six suggestions for designing new software, specifically regarding simplifying the design for users, communication with the programmer, a rapid cycle from design to implementation, orientation support for users, backup and security support, and obtaining patents. Collaborating with the Department of Medical Informatics within the School of Medicine has advantages, and an alliance among medical schools can simplify the development of software. In any case, curricular innovation should precede the introduction of technology because all technologies should support curricular goals.

태아(胎兒)의 발달과정(發達過程)에서 찾아본 악조(惡阻)의 원인(原因)에 대한 고찰(考察) (A Study on the Cause of Nausea and Vomiting of Pregnancy in Relation to Fetal Development)

  • 윤은경;김종현
    • 대한한의학원전학회지
    • /
    • 제32권2호
    • /
    • pp.147-163
    • /
    • 2019
  • Objectives : Morning Sickness, or Nausea and Vomiting of Pregnancy(NVP) is a frequently experienced phenomenon among pregnant women whose cause is still unknown. While the key trait of this symptom is its temporality, it is hardly considered in existing studies on the cause of NVP based on Korean Medical(KM) literature. We hope to remedy this. Methods : We looked for contents on fetal development in Korean Medical literature from the Siku Quanshu as well as other key literature of KM and examined the results together with contents on NVP to find any correlation. Results : We found that the beginning stages, namely the third month marked a significant change in the course of fetal development where the fetus's own Shen(神) is first developed by work of the mother's Heart(心). In other words, the third month is when the mother's and child's Shen first encounter. Conclusions : We hypothesized that NVP whose symptoms are closely linked to the functions of the Heart, is likely to be related to this event, which was supported by the common involvement of the Heart which was involved in both fetal development and NVP during the third month of pregnancy.

Three cases of rare SRY-negative 46,XX testicular disorder of sexual development with complete masculinization and a review of the literature

  • Lee, Bom Yi;Lee, Shin Young;Lee, Yeon Woo;Kim, Shin Young;Kim, Jin Woo;Ryu, Hyun Mee;Lee, Joong Shik;Park, So Yeon;Seo, Ju Tae
    • Journal of Genetic Medicine
    • /
    • 제13권2호
    • /
    • pp.78-88
    • /
    • 2016
  • Purpose: To identify the clinical characteristics of SRY-negative male patients and genes related to male sex reversal, we performed a retrospective study using cases of 46,XX testicular disorders of sex development with a review of the literature. Materials and Methods:SRY-negative cases of 46,XX testicular disorders of sex development referred for cytogenetic analysis from 1983 to 2013 were examined using clinical findings, seminal analyses, basal hormone profiles, conventional cytogenetic analysis and polymerase chain reaction. Results: Chromosome analysis of cultured peripheral blood cells of 8,386 individuals found 19 cases (0.23%) with 46,XX testicular disorders of sex development. The SRY gene was confirmed to be absent in three of these 19 cases (15.8%). Conclusion: We report three rare cases of SRY-negative 46,XX testicular disorders of sex development. Genes on autosomes and the X chromosome that may have a role in sex determination were deduced through a literature review. These genes, through differences in gene dosage variation, may have a role in sex reversal in the absence of SRY.

치매 치료 VR 시스템 개발 (Development of Dementia Treatment VR System)

  • 이기석;김상원;김용완;김민영;최진성
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2002년도 추계학술발표논문집 (상)
    • /
    • pp.835-838
    • /
    • 2002
  • 사회고령화 추세에 따라 노인들이 증가하고 있으며 자연적으로 발생률이 높아지고 있는 치매에 대한 사회적 문제가 대두되고 있다. 본 논문에서는 경증 치매나 치매에 걸릴 확률이 높은 사람들에게 치매 치료의 효과를 주는 VR기반의 의료시스템을 개발하여 치매 치료에 대한 새로운 방법을 제시하려고 한다. 제시하는 치료 요법은 사용자에게 일상생활과 유사하게 VR 환경을 제공하고 일상적인 문제에 대처하여 올바르게 수행하도록 하는 방법을 가진다. 개발되어진 다양한 시나리오의 반복 수행을 통하여 치매의 치료는 수행되게 된다. 본 시스템의 효과를 판단하기 위해 실험군과 대조군 각 15명을 통하여 임상실험을 수행하였으며 그 결과를 보였다.

  • PDF

중국 민간의료보험의 발전경로와 의료보장체계에서의 역할 (The Development Path of China's Private Health Insurance and Its Role in the Health Care System)

  • 정기택
    • 보건행정학회지
    • /
    • 제31권4호
    • /
    • pp.423-436
    • /
    • 2021
  • This article summarizes the structure of China's current social health insurance system and reviews the development status of China's private health insurance (PHI). China's medical security system is mainly composed of two parts: basic medical insurance (BMI) and PHI. Among them, the BMI provides reimbursement of basic medical expenses for the insured persons according to different proportions. PHI is a necessary supplement to the BMI and provides assistance to the insured persons in the event of illness or accident. By having PHI, people can obtain medical protection outside the coverage of BMI. In the development of PHI in China, the total medical cost is high and the insurance market size is large, but the proportion of PHI expenditure is low and the personal burden is high. Through this Chinese case, it will be helpful for mutual development between Korean PHI and national health insurance, for Korean insurance companies to enter the Chinese market, and for removing the medical burden on the people.

주요국의 혁신적 의료기기 관리제도에 대한 비교 연구 (A Comparative Study on Innovative Medical Device Management Systems in Major Countries)

  • 이진수;김수경
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.153-160
    • /
    • 2022
  • As new types of medical devices are emerging through convergence with advanced technology, innovative technologies are becoming hot issues in health policy because of their disruptiveness. This study analyzed the innovative medical device management systems in the US, China and Korea. Innovative medical devices have been defined differently depending on the country's management system, but in common, they are defined as products that do not exist or have dramatically improved performance compare to existing products by applying innovative technologies. Innovative medical devices have been supported by regulatory authorities during product development and approval processes. While the US and China have more than 300 products designated as innovative medical devices with diverse functions, application fields, and manufacturing countries considering the initial situation of the implementation for the system, Korea has only 16 products, mainly radiology and diagnostic devices and made in Korea only as innovative medical device. In addition, Korea shows the highest market approval rate of innovative medical devices compare to the US and China, and it is necessary to prepare the approval process in consideration of product diversity.