• Title/Summary/Keyword: mechanical system

Search Result 19,916, Processing Time 0.046 seconds

Preparation of Polyacrylate-Based Non-Reinforced Anion Exchange Membranes via Photo-Crosslinking for Reverse Electrodialysis (역전기투석용 광가교형 폴리아크릴레이트계 음이온교환막 제조)

  • Tae Hoon Kim;Seok Hwan Yang;Jang Yong Lee
    • Membrane Journal
    • /
    • v.34 no.1
    • /
    • pp.70-78
    • /
    • 2024
  • A photo-crosslinked anion exchange membrane (AEM) based on quaternary-aminated polyacrylates was developed for reverse electrodialysis (RED). Although reverse electrodialysis is a clean and renewable energy generation system, the low power output and high membrane cost are serious obstacles to its commercialization. Cross-linked AEMs without any polymer supporters were fabricated through photo-crosslinking between polymer-typed acrylates with anion conducting groups, in particular, polymer-typed acrylates were synthesized based on engineering plastic with outstanding mechanical and chemical property. The fabricated membranes showed outstanding physical, chemical, and electrochemical properties. The area resistance of the fabricated membranes (CQAPPOA-20, CQAPPOA-35, and CQAPPOA-50) were ~50% lower than that of AMV (2.6 Ω cm2). Moreover, the transport number of CQAPPOA-35 wase comparable to that of AMV, despite the thin thickness (40 ㎛) of the fabricated membranes. The RED stack with the CQAPPOA-35 membrane provided an excellent maximum power density of 2.327 W m-2 at a flow rate of 100 mL min-1, which is 15% higher than that (2.026 W m-2) of the RED stack with the AMV membrane. Considering easy fabrication process by UV photo-crosslinking and outstanding RED stack properties, the CQAPPOA-35 membrane is a promising candidate for REDs.

Dynamic Shear Behavior Characteristics of PHC Pile-cohesive Soil Ground Contact Interface Considering Various Environmental Factors (다양한 환경인자를 고려한 PHC 말뚝-사질토 지반 접촉면의 동적 전단거동 특성)

  • Kim, Young-Jun;Kwak, Chang-Won;Park, Inn-Joon
    • Journal of the Korean Geotechnical Society
    • /
    • v.40 no.1
    • /
    • pp.5-14
    • /
    • 2024
  • PHC piles demonstrate superior resistance to compression and bending moments, and their factory-based production enhances quality assurance and management processes. Despite these advantages that have resulted in widespread use in civil engineering and construction projects, the design process frequently relies on empirical formulas or N-values to estimate the soil-pile friction, which is crucial for bearing capacity, and this reliance underscores a significant lack of experimental validation. In addition, environmental factors, e.g., the pH levels in groundwater and the effects of seawater, are commonly not considered. Thus, this study investigates the influence of vibrating machine foundations on PHC pile models in consideration of the effects of varying pH conditions. Concrete model piles were subjected to a one-month conditioning period in different pH environments (acidic, neutral, and alkaline) and under the influence of seawater. Subsequent repeated direct shear tests were performed on the pile-soil interface, and the disturbed state concept was employed to derive parameters that effectively quantify the dynamic behavior of this interface. The results revealed a descending order of shear stress in neutral, acidic, and alkaline conditions, with the pH-influenced samples exhibiting a more pronounced reduction in shear stress than those affected by seawater.

Korean Society of Heart Failure Guidelines for the Management of Heart Failure: Management of the Underlying Etiologies and Comorbidities of Heart Failure

  • Sang Min Park;Soo Youn Lee;Mi-Hyang Jung;Jong-Chan Youn;Darae Kim;Jae Yeong Cho;Dong-Hyuk Cho;Junho Hyun;Hyun-Jai Cho;Seong-Mi Park;Jin-Oh Choi;Wook-Jin Chung;Seok-Min Kang;Byung-Su Yoo;Committee of Clinical Practice Guidelines, Korean Society of Heart Failure
    • Korean Circulation Journal
    • /
    • v.53 no.7
    • /
    • pp.425-451
    • /
    • 2023
  • Most patients with heart failure (HF) have multiple comorbidities, which impact their quality of life, aggravate HF, and increase mortality. Cardiovascular comorbidities include systemic and pulmonary hypertension, ischemic and valvular heart diseases, and atrial fibrillation. Non-cardiovascular comorbidities include diabetes mellitus (DM), chronic kidney and pulmonary diseases, iron deficiency and anemia, and sleep apnea. In patients with HF with hypertension and left ventricular hypertrophy, renin-angiotensin system inhibitors combined with calcium channel blockers and/or diuretics is an effective treatment regimen. Measurement of pulmonary vascular resistance via right heart catheterization is recommended for patients with HF considered suitable for implantation of mechanical circulatory support devices or as heart transplantation candidates. Coronary angiography remains the gold standard for the diagnosis and reperfusion in patients with HF and angina pectoris refractory to antianginal medications. In patients with HF and atrial fibrillation, longterm anticoagulants are recommended according to the CHA2DS2-VASc scores. Valvular heart diseases should be treated medically and/or surgically. In patients with HF and DM, metformin is relatively safer; thiazolidinediones cause fluid retention and should be avoided in patients with HF and dyspnea. In renal insufficiency, both volume status and cardiac performance are important for therapy guidance. In patients with HF and pulmonary disease, beta-blockers are underused, which may be related to increased mortality. In patients with HF and anemia, iron supplementation can help improve symptoms. In obstructive sleep apnea, continuous positive airway pressure therapy helps avoid severe nocturnal hypoxia. Appropriate management of comorbidities is important for improving clinical outcomes in patients with HF.

Development of an Automated Synthesizer for the Routine Production of Ga-68 Radiopharmaceuticals (임상용 Ga-68 표지 방사성의약품의 합성을 위한 자동합성장치 개발)

  • Jun Young PARK;Jeongmin SON;Won Jun KANG
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.55 no.4
    • /
    • pp.253-260
    • /
    • 2023
  • The germanium-68/gallium-68 (68Ge/68Ga) generator has high spatial utilization and requires little maintenance, making it economical and easy to produce. Thus, the frequency of use of 68Ga radiopharmaceuticals is rapidly increasing worldwide. Therefore, this study attempted to develop an automated synthesizer for the routine clinical application of 68Ga radiopharmaceuticals. The automated synthesizer was based on a fixed tubing system and the structure was designed after adjusting the position of the parts to reflect the synthesis method. Using various components that can be supplied in Korea, the automated synthesizer was manufactured at a much lower price cost than that of a commercialized automated synthesizer sold by companies. 68Ga-DOTA-[Tyr3]-octreotide (68Ga-DOTATOC) was synthesized to evaluate the performance of the automated synthesizer. 68Ga-DOTATOC could be synthesized with about 65% of non-decay corrected yield, and the synthesized 68Ga-DOTATOC met all quality control standards. We have synthesized 68Ga-DOTATOC more than 100 times, and only faced a few problems caused by mechanical errors. In this study, we successfully developed a simple automated synthesizer for 68Ga radiopharmaceuticals with high reproducibility. As various 68Ga radiopharmaceuticals have recently been developed, it is expected that the automated synthesizer developed in this study will be useful for routine clinical use.

Experimental Study on the Adhesion and Performance Evaluation of Joints for Modified Polyethylene Coated Steel Pipes (개질 폴리에틸렌 코팅 강관의 부착 및 체결부 성능 평가 연구)

  • Myung Kue Lee;Sanghwan Cho;Min Ook Kim
    • Composites Research
    • /
    • v.37 no.3
    • /
    • pp.238-245
    • /
    • 2024
  • In this study, as part of the development of a monitoring system for the efficient maintenance of steel pipes, an experimental study was conducted to evaluate the performance of steel pipes treated with modified polyethylene coating. In the case of the conventional mechanical pre-coating method, there was a deterioration in polyethylene adhesion during expansion testing, which led to the application of a chemical pre-treatment process using a calcium-mixed phosphate zinc film to resolve this issue. SEM and EDX analyses showed that the densest structure was observed at a Zn/Ca ratio of 1.0, and improved heat resistance compared to the conventional method was confirmed. Additionally, to prevent coating detachment during expansion, an evaluation of adhesion and elongation was conducted on steel pipes with modified polyethylene coating, incorporating materials such as elastomers based on maleic anhydride grafting, metal oxides, blocking agents, and slip agents. Experimental results showed that the specimen (S4) containing all modified materials exhibited more than a 25% performance improvement compared to the specimen (S2) containing only metal oxides. Lastly, the development and performance evaluation of wedge-shaped socketing and pressing wheels, which are part of the pipe fixing accessories, were conducted to prevent surface coating damage on the completed pipes.

Forced vibrations of an elastic rectangular plate supported by a unilateral two-parameter foundation via the Chebyshev polynomials expansion

  • Zekai Celep;Zeki Ozcan
    • Structural Engineering and Mechanics
    • /
    • v.90 no.6
    • /
    • pp.551-568
    • /
    • 2024
  • The present study deals with static and dynamic behaviors including forced vibrations of an elastic rectangular nano plate on the two-parameter foundation. Firstly, the rectangular plate is assumed to be subjected to uniformly distributed and eccentrically applied concentrated loads. The governing equations of the problem are derived by considering the dynamic response of the plate, employing a series of the Chebyshev polynomials for the displacement function and applying the Galerkin method. Then, effects of the non-essential boundary conditions of the plate, i.e., the boundary conditions related to the shearing forces, the bending moments and the corner forces, are included in the governing equation of motion to compensate for the non-satisfied boundary conditions and increase the accuracy of the Galerkin method. The approximate numerical solution is accomplished using an iterative process due to the non-linearity of the unilateral property of the two-parameter foundation. The plate under static concentrated load is investigated in detail numerically by considering a wide range of parameters of the plate and the foundation stiffnesses. Numerical treatment of the problem in the time domain is carried out by assuming a stepwise variation of the concentrated load and the linear acceleration procedure is employed in the solution of the system of governing differential equations derived from the equation of motion. Time variations of the contact region and those of the displacements of the plate are presented in the figures for various numbers of the two-parameter of the foundation, as well as the classical and nano parameters of the plate particularly focusing on the non-linearity of the problem due to the plate lift-off from the unilateral foundation. The effects of classical and nonlocal parameters and loading are investigated in detail. Definition of the separation between the plate and the two-parameter foundation is presented and applied to the given problem. The effect of the lift-off on the static and dynamic behavior of the rectangular plate is studied in detail by considering various loading conditions. The numerical study shows that the effect of nonlocal parameters on the behavior of the plate becomes significant, when nonlinearity becomes more profound, due to the lift-off of the plate. It is seen that the size effects are significant in static and dynamic analysis of nano-scaled rectangular plates and need to be included in the mechanical analyses. Furthermore, the corner displacement of the plate is affected more significantly from the lift-off, whereas it is less marked in the time variation of the middle displacement of the plate. Several numerical examples are presented to examine the sensibility of various parameters associated with nonlocal parameters of the plate and foundation. Both stiffening and softening nonlocal parameters behavior of the plate are identified in the numerical solutions which show that increasing the foundation stiffness decreases the extent of the contact region, whereas the stiffness of the shear layer increases the contact region and reduces the foundation settlement considerably.

Evaluation of the stress distribution in the external hexagon implant system with different hexagon height by FEM-3D (임플란트 hexagon 높이에 따른 임플란트와 주위 조직의 응력분포 평가)

  • Park, Seong-Jae;Kim, Joo-Hyeun;Kim, So-Yeun;Yun, Mi-Jung;Ko, Sok-Min;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.36-43
    • /
    • 2012
  • Purpose: To analyze the stress distribution of the implant and its supporting structures through 3D finite elements analysis for implants with different hexagon heights and to make the assessment of the mechanical stability and the effect of the elements. Materials and methods: Infinite elements modeling with CAD data was designed. The modeling was done as follows; an external connection type ${\phi}4.0mm{\times}11.5mm$ Osstem$^{(R)}$ USII (Osstem Co., Pusan, Korea) implant system was used, the implant was planted in the mandibular first molar region with appropriate prosthetic restoration, the hexagon (implant fixture's external connection) height of 0.0, 0.7, 1.2, and 1.5 mm were applied. ABAQUS 6.4 (ABAQUS, Inc., Providence, USA) was used to calculate the stress value. The force distribution via color distribution on each experimental group's implant fixture and titanium screw was studied based on the equivalent stress (von Mises stress). The maximum stress level of each element (crown, implant screw, implant fixture, cortical bone and cancellous bone) was compared. Results: The hexagonal height of the implant with external connection had an influence on the stress distribution of the fixture, screw and upper prosthesis and the surrounding supporting bone. As the hexagon height increased, the stress was well distributed and there was a decrease in the maximum stress value. If the height of the hexagon reached over 1.2mm, there was no significant influence on the stress distribution. Conclusion: For implants with external connections, a hexagon is vital for stress distribution. As the height of the hexagon increased, the more effective stress distribution was observed.

Variability of Satellite-derived Chlorophyll-a Concentration in Relation to Indian Ocean Dipole (IOD) Variation (인도양 쌍극진동 변동에 따른 위성에서 추정된 표층 클로로필-a 농도 변화 연구)

  • Son, Young Baek;Kim, Suk Hyun;Kim, Sang-Hyun;Rho, TaeKeun
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.6_1
    • /
    • pp.917-930
    • /
    • 2017
  • To understand the temporal and spatial variations of surface chlorophyll-a concentration (Chl-a) distribution in the Indian Ocean ($30^{\circ}E{\sim}120^{\circ}E$, $30^{\circ}S{\sim}30^{\circ}N$) by the Indian Ocean Dipole (IOD), we conducted EOF and K means analyses of monthly satellite-derived Chl-a data in the region during 1998~2016 periods. Chl-a showed low values in the central region of the Indian Ocean and relatively high values in the upwelling region and around the marginal regions of the Indian Ocean. It also had a strong seasonal variation of Chl-a, showing the lowest value in the spring and the highest value in summer due to the change of the monsoon and current system. The EOF analysis showed that Chl-a variation in EOF mode 1 is related to ENSO (El $Ni{\tilde{n}}o$/Southern Oscillation) and that of mode 2 is linked to IOD. Both modes explained spatially opposite trends of Chl-a in the east and west Indian Ocean. From K means analysis, the Chl-a variation in the east and west Indian Ocean, and around India have relatively good relationship with IOD while that in the tropical and middle Indian Ocean closely associated with ENSO. The spatial and temporal distribution of Chl-a also showed distinct spatial and temporal variations depend on the different types of IOD events. IOD classifies two patterns, which occurred during the developing ENSO (First Type IOD) and the year following ENSO event (Second Type IOD). Chl-a variation in the First Type IOD started in summer and peaked in fall around the east and west Indian Ocean. Chl-a variation in the Second Type IOD occurred started in spring, peaked in summer and fall, and disappeared in winter. In the Chl-a variation related to IOD, developing process appearing in the Chl-a difference between the east and west Indian ocean was similar. Chl-a variation in the northern Indian Ocean were opposite trend with changing developing phase of IOD.

A Short Composting Method by the Single Phase Composter for the Production of Oyster Mushroom (느타리버섯 배지 제조기를 이용한 배지의 제조 연구)

  • Lee, Ho-Yong;Shin, Chang-Yup;Lee, Young-Keun;Chang, Hwa-Hyoung;Min, Bong-Hee
    • The Korean Journal of Mycology
    • /
    • v.27 no.1 s.88
    • /
    • pp.10-14
    • /
    • 1999
  • A single phase composter was constructed by modifying the conventional mixer of sawdust for the cultivation of oyster mushroom Pleurotus ostreatus. The machine was designed on the basis of 3-phase-1 system which was controlled in prewetting, pasteurization and fermentation processes. In composting 200 kg of straw and cotton waste in the machine, it took 20 minutes in prewetting step and also to hours at $65^{\circ}C$ in pasteurization process. Postfermentation by aerothermophiles was completed by treating the compost at $45^{\circ}C-50^{\circ}C$ for 48 hours which was shorten 24 hours from the conventional method. In the postfermentation at high temperature, forced aeration and/or vigorous mixing process(es) played a great role in the improvement of spawn quality. The growth of mycelium of oyster mushroom was excellent in the culture combinated with 3 parts of surface inoculation and 7 parts of mechanical mixing.

  • PDF

Effect of Biodegradable Waste Particle Size on Aerobic Stabilization Reactions in MBT System (생분해성 폐기물 입경이 MBT시스템과 연계된 호기성안정화반응에 미치는 영향)

  • Kwon, Sang-Hagk;Ban, Jong-Sub;Kim, Su-Jin;Phae, Chae-Gun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.7
    • /
    • pp.523-529
    • /
    • 2011
  • This study has been performed to examine the influence of the size of particles on the stabilization in the aerobic stabilization equipment connected with MBT system. The biodegradable waste inside the reactor (60% of food waste, 25% of paper waste, 2% of wood waste and 5% of compost) has been charged in same composition. The degree of stabilization was compared and analyzed after charging with adjustment of particle size in 5 mm, 10 mm, 20 mm, 50 mm, 100 mm and state of no separation. The experiment revealed that highest temperature beyond $65^{\circ}C$ was shown in the particle size of less than 50 mm in change of temperature and the highest temperature was about $50^{\circ}C$ in reactor of 100 mm and no separation. The proportionality between generated quantity of $CO_2$ and particle size was not observed, even the highest in generated quantity was shown in over 100 mm. The weight changes based on wet and dry conditions in the reaction process showed the 30% and 46% of reduction in the smallest particle size of 5 mm and it showed the trend of the lower reduction rate at the bigger particle size. The water soluble $COD_{Cr}$ and TOC showed the reduction rate of 60% in reactor of particle size in 100 mm and no separation while the reduction rate comparing to the initial stage of reaction in the reactor of less than 50 mm was 80%. Such result derived the conclusion of acceleration in the decomposing stabilization of biodegradable material due to the decomposing rate of organic substance as the particle size of biodegradable waste gets smaller. It is concluded as necessary to react in adjustment under 50 mm of particle size as much as possible.