Autogenous Low Heat Treated Bone Graft for Bone Reconstruction in Bone and Soft Tissue Tumors (골연부 종양에서 저온 열처리한 자가골을 이용한 재건술)

  • Jeon, Dae-Geun;Lee, Jong-Seok;Kim, Sug-Jun;Cho, Wan-Hyeong;Kwag, Bong-Jun;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.4 no.2
    • /
    • pp.81-87
    • /
    • 1998
  • Although autoclaved autogenous bone reconstruction is one of the established procedures, it may have some problems in bone regeneration and mechanical property. The purpose of this study is to evaluate the efficacy of more biologic and anatomical reconstruction where allograft is not readily available. From Aug.1991 to Feb. 1996 the authors analyzed 32 cases of reconstruction with autogenous low heat treated bone. Autogenous graft sites were humerus 4, tibia 4, pelvis 9, and 15 femur. Average follow-up period was 23(range;12-51) months. There were 49 graft-host junctional sites. Diaphysis was 22, metaphysis 10, and flat bone 17. Average duration of healing for the 38 united sites was 7 months. Average union time for each anatomical area 8 months in 19 diaphysis, 12 months in 7 metaphysis, and 12.7 months in 12 flat bone(pelvis). Eleven nonunion sites consisted of 3 diaphysis(3/22), 3 metaphysis(3/10), and 5 flat bone(5/17). Complications other than nonunion were local recurrence(4), bone resorption(3), graft fracture(2), osteomyelitis(1), metal failure(2), and wound infection(1). Initial bone quality and stable fixation technique was important for union rate. Plate and screw is a good method for diaphyseal lesion. Metaphyseal and flat bone are weak area for rigid fixation and one stage augmentation with iliac bone graft can be a salvage procedure.

  • PDF

PHOTOELASTIC STRESS ANALYSIS OF LOAD TRANSFER TO SATELLITE ABUTMENT AS AN IMMEDIATE ABUTMENT (인공치아의 즉시부하를 위해 새로이 개발된 인공치아 지대주(Satellite Abutment)의 광탄성 응력 분석)

  • Park, Sang-Kyu;Lee, Baek-Soo;Engelke, W;Kim, Boo-Dong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.6
    • /
    • pp.472-479
    • /
    • 2002
  • Since $Br^{\circ}anemark$ introduced the osseointegrated implants, they have been granted for useful methods for the restoration of oral function. The original $Br^{\circ}anemark$ protocol recommended long stress-free healing periods to achieve the osseointegration of dental implants. However, many clinical and experimental studies have shown that the osseointegration is no wonder in almost cases and that early and immediate loading may lead to predictable osseointegration. So we are willing to introduce the Satellite Abutment newly invented for immediate loading. We think that it will make the occlusal forces dispersed to surrounding bone and that we can restore the oral function immediately after implant installation not disturbing osseointegration. In case of using Satellite abutment, stress concentrated to bone contact area of implant was distributed not only fixation plate and screws but also superior, middle portion of implant and cortical layer of jaw bone. It was clearly decreased on the bone contact surfaces around dental implants. 1. Stress was decreased more than 76.5% when satellite straight abutment was used. 2. Stress was decreased more than 50% when satellite angled abutment was used. 3. The stress around dental implant was well distributed along the cortical bone surface and the fixation plate and screw. This study concludes that satellite abutment can be used as all immediate loading implant prothesis because it was possible to distribute periimplant occlusal stress through implant contact bone surface and cortical layer of jaw bone.

Effects on Tensile Strength and Elasticity after Treatment with Glutaraldehyde, Solvent, Decellularization and Detoxification in Fresh Bovine Pericardium (소의 심낭 고정에서 용매 처치, 무세포화 혹은 항독성화 처치가 조직의 장력 및 신장도에 미치는 영향)

  • Jang, Woo Sung;Kim, Yong Jin;Kim, Soo Hwan
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.1-10
    • /
    • 2010
  • Background: Bioprosthetic materials have been made using glutaraldehyde fixation of porcine or bovine pericardium during cardiovascular surgery. But these bioprostheses have the problems of calcification and mechanical failure. We determined changes in tensile strength and elasticity of pericardium after glutaraldehyde, solvent, decellularization and detoxification. Material and Method: Tissues were allocated to four groups: glutaraldehyde with and without solvent, decellularization, and detoxification. We studied tensile strength and strain on tissues. We measured the tensile strength of fresh pericardium stretched in six directions (with 5 mm width), and % strain, which we calculated from the breaking point when we pulled the pericardium in two directions. Result: Tensile strength was reduced when we used the usual concentrated glutaraldehyde fixation (n=83, $MPa=11.47{\pm}5.40$, p=0.006), but there was no change when we used solvent. Elasticity was increased after glutaraldehyde fixation (n=83, strain $(%)=24.55{\pm}9.81$, p=0.00), but there was no change after solvent. After decellularization of pericardium, the tensile strength was generally reduced. The decrease in tensile strength after concentrated glutaraldehyde fixation for a long time was significantly greater less than after concentrated solvent (p=0.01, p=0.00). After detoxification, the differences in strength and strain were not significant. Conclusion: After glutaraldehyde treatment of pericardium there is no loss in tensile strength (even though we did the glutaraldehyde, solvent and detoxification treatments LOGIC IS UNCLEAR). Also, these treatments had a tendency to increase elasticity. Although post-treatment decellularization led to a significant loss in strength, this effect could be attenuated using a low concentration of solvent or hypertonic solution.

Rib Fractures: To Fix or Not to Fix? An Evidence-Based Algorithm

  • Bemelman, Michael;de Kruijf, M.W.;van Baal, Mark;Leenen, Luke
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.229-234
    • /
    • 2017
  • Rib fractures are a common injury resulting from blunt chest trauma. The most important complications associated with rib fractures include death, pneumonia, and the need for mechanical ventilation. The development of new osteosynthesis materials has stimulated increased interest in the surgical treatment of rib fractures. Surgical stabilisation, however, is not needed for every patient with rib fractures or for every patient with flail chest. This paper presents an easy-to-use evidence-based algorithm, developed by the authors, for the treatment of patients with flail chest and isolated rib fractures.

A Study for Improvement of the Femoral Stem Type using the Finite Element Analysis (유한요소법을 이용한 인공고관절 주대형태의 개선에 대한 연구)

  • 윤경렬;원예연;이수훈
    • Korean Journal of Computational Design and Engineering
    • /
    • v.5 no.2
    • /
    • pp.122-126
    • /
    • 2000
  • A major mechanical problem with total hip replacement is the loosening of the femoral component. The loss of proximal support, with firm fixation distally, has been thought to be a major caused of fatigue failure of femoral stems. While many causes have been proposed, the most frequently suggested cause of the calcar resorption is the disuse atrophy of the cortex of the calcar due to the stress shielding of the proximal bone by the metal femoral stem. In this research, the new-designed stem(modified collar stem) was considered which made a hole inside stem and had a 3 mm thickness. Using the 3-dimensional finite element methods, the common collar stem and the modified colla stem was modeled and analysed. Also, the two models was compared. The results showed that the modified collar stem decreased the stress-shielding and it made a effective load transfer at the entire femoral region.

  • PDF

Mount Design for High-Resolution Mirrors (고 분해능 반사경의 마운트 설계)

  • Kim, Kwang-Ro;Lee, Young Shin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.142-148
    • /
    • 2014
  • The mirror which is considered in designing a MFD is off-axis primary one and its dimension is wide 556mm height 345mm. The MFD(Mirror Fixation Device) load specification is generated for the high resolution mirror. The optical WFEs for unit loads are calculated from mirror sensitivity analysis and they are compared with allocated allowable optical WFE. The parasite load for the MFD is calculated from their comparison. The MFD compliant with the parasite load is designed.

A Study on the Structural Safety Analysis of Neck Mount Block of Type 4 Hydrogen Storage Vessel by Finite Element Method (유한요소법을 이용한 type 4 수소저장용기용 고정 장치의 구조적 안전성 분석에 관한 연구)

  • GUNWOO KIM;HYEWON KIM;HANMIN PARK;JEONGHO LEE;SUJIN YOON;HANSU LEE;JOUNGLYUL KIM;SEOKJIN LEE;GYEHYOUNG YOO;YOUNGGIL YOUN;HANSANG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.2
    • /
    • pp.195-204
    • /
    • 2024
  • The study involves a finite element analysis to evaluate the structural integrity of the neck mount block for a type 4 hydrogen storage vessel, with the aim of enhancing its strength and rigidity. The existing neck mount block consists of a fixed part and a sliding part, each comprising a body block for load support, a screw part for neck boss fixation, and bolts. To analyze the vulnerabilities of the neck mount block under bolt fastening and load conditions relative to vehicle travel directions, a structural analysis process was developed. Comparative analysis between the enhanced design and the existing model was performed, resulting in improved strength and rigidity. The objective is to provide guidance for the current product development and to offer fundamental data for the design and structural analysis of future development projects.

Correction of Spondylolisthesis by Lateral Lumbar Interbody Fusion Compared with Transforaminal Lumbar Interbody Fusion at L4-5

  • Ko, Myeong Jin;Park, Seung Won;Kim, Young Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.422-431
    • /
    • 2019
  • Objective : In an aging society, the number of patients with symptomatic degenerative spondylolisthesis (DS) is increasing and there is an emerging need for fusion surgery. However, few studies have compared transforaminal lumbar interbody fusion (TLIF) and lateral lumbar interbody fusion (LLIF) for the treatment of patients with DS. The purpose of this study was to investigate the clinical and radiological outcomes between TLIF and LLIF in DS. Methods : We enrolled patients with symptomatic DS at L4-5 who underwent TLIF with open pedicle screw fixation (TLIF group, n=41) or minimally invasive LLIF with percutaneous pedicle screw fixation (LLIF group, n=39) and were followed-up for more than one year. Clinical (visual analog scale and Oswestry disability index) and radiological outcomes (spondylolisthesis rate, segmental sagittal angle [SSA], mean disc height [MDH], intervertebral foramen height [FH], cage subsidence, and fusion rate) were assessed. And we assessed the changes in radiological parameters between the postoperative and the last follow-up periods. Results : Preoperative radiological parameters were not significantly different between the two groups. LLIF was significantly superior to TLIF in immediate postoperative radiological results, including reduction of spondylolisthesis rate (3.8% and 7.2%), increase in MDH (13.9 mm and 10.3 mm) and FH (21.9 mm and 19.4 mm), and correction of SSA ($18.9^{\circ}$ and $15.6^{\circ}$) (p<0.01), and the changes were more stable from the postoperative period to the last follow-up (p<0.01). Cage subsidence was observed significantly less in LLIF (n=6) than TLIF (n=21). Fusion rate was not different between the two groups. The clinical outcomes did not differ significantly at any time point between the two groups. Complications were not statistically significant. However, TLIF showed chronic mechanical problems with screw loosening in four patients and LLIF showed temporary symptoms associated with the surgical approach, such as psoas and ileus muscle symptoms in three and two cases, respectively. Conclusion : LLIF was more effective than TLIF for spondylolisthesis reduction, likely due to the higher profile cage and ligamentotactic effect. In addition, LLIF showed mechanical stability of the reduction level by using a cage with a larger footprint. Therefore, LLIF should be considered a surgical option before TLIF for patients with unstable DS.

Property enhancement of lightweight aggregate by carbonation processing (인공경량골재의 탄산화 반응에 따른 물성향상에 관한 연구)

  • Park, Junyoung;Kim, Yootaek;Choi, Yunjae
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.5
    • /
    • pp.254-259
    • /
    • 2012
  • The mechanical property enhancement was studied using fly ash produced from fluidized bed type boiler in power plant, which contains a lot of Ca component being used to carbonate for $CO_2$ fixation in the lightweight aggregates made of cement and some portion of fly ash as a cement substitution under the supercritical condition. Specimens having various fly ash substitution rates and curing periods were carbonated under the supercritical condition at $40^{\circ}C$. The weight change rate, carbonation rate by TG/DTA analysis, 1% Phenolphthalein test, specific gravity and mechanical compression strength test were performed to observe the mechanical property enhancement of the cemented materials after carbonation under the supercritical condition and to make sure those could be classified as lightweight aggregates having specific gravity under 2.0.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.