• 제목/요약/키워드: mechanical breathing simulator

검색결과 2건 처리시간 0.018초

인체 호흡 모사를 위한 기계적 장치 연구 (The Study of Mechanical Simulation for Human Respiratory System)

  • 지석환;이문규;이태수;최윤순;오승권
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권4호
    • /
    • pp.323-328
    • /
    • 2008
  • A patient with respiratory disorders such as a sleep apnea is increasing as the obese patient increase on the modern society. Positive Airway Pressure (PAP) devices are used in curing patient with respiratory disorders and turn out to be efficacious for patients of 75%. However, these devices are required for evaluating their performance to improve their performance by the mechanical breathing simulator. Recently, the mechanical breathing simulator was studied by the real time feedback control. However, the mechanical breathing simulator by an open loop control was specially required in order to analyze the effect of flow rate and pressure after operating the breathing auxiliary devices. Therefore the aims of this study were to make the mechanical breathing simulator by a piston motion and a valve function from the characteristic test of valve and motor, and to duplicate the flow rate and pressure profiles of some breathing patterns: normal and three disorder patterns. The mechanical simulator is composed cylinder, valve, ball screw and the motor. Also, the characteristic test of the motor and the valve were accomplished in order to define the relationship between the characteristics of simulator and the breathing profiles. Then, the flow rate and pressure profile of human breathing patterns were duplicated by the control of motor and valve. The result showed that the simulator reasonably duplicated the characteristics of human patterns: normal, obstructive sleep apnea (OSA), mild hypopnea with snore and mouth expiration patterns. However, we need to improve this simulator in detail and to validate this method for other patterns.

모터와 비례제어 밸브의 특성실험을 통한 기계적 호흡 모사장치연구 (The study of mechanical human respiratory simulator via characteristic test of motor and proportional valve)

  • 이문규;지석환;이태수;오승권
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.492-495
    • /
    • 2008
  • As the obesity patients increase recently, breath disease such an OSA(obstructive sleep apnea) is also increasing. When the breath disease occurs, the risk comes to be high. Dependence degree the PAP(positive airway pressure) is also coming to be high. The mechanical simulator is composed cylinder, valve, ball screw and the motor that they correspond to the lung and airway, the diaphragm of the human. In order to confirm the characteristic of the motor and the valve, it accomplished an test. The simulator traces breath pattern against the normal breath and the OSA.

  • PDF