Characteristics of Water and Sediment Qualities in the Oncheon Stream, Busan during Summer Rainy Season (부산 온천천의 하계 우수기 수질 및 퇴적물 환경 특성)

  • Lee, Young-Hyeong;Moon, Changho;Kang, Hyun-Jung;Choi, Seong-Ryul;Kim, Suk-Hyun
    • Journal of Environmental Science International
    • /
    • v.29 no.6
    • /
    • pp.659-672
    • /
    • 2020
  • Water and sediment qualities were investigated in the Oncheon Stream and at the Wondong bridge of the Suyoung River, during the summer rainy season, 2019. Dissolved oxygen (DO) showed the lowest levels at 4.7 and 5.0 m/L, and biogeochemical oxygen demand (BOD) showed the highest at 5.3 mg/L downstream where the tributary flows into the main river. Chemical oxygen demand (COD) increased from 2.0 to 5.9 mg/L on average as it flowed downstream, The COD/BOD ratio decreased gradually as it flowed downstream, reaching 1.0. However, COD/BOD ratio at the Wondong bridge was 5.8-22.2, indicating that easily biodegradable and non-biodegradable organic matter flows into the Oncheon Stream and Suyoung River, respectively. Total nitrogen (T-N) / total phosphorus (T-P) ratio tended to decrease from 72 to 21 as it flowed downstream, measuring 71 to 86 at the Wondong bridge. The water quality index (WQI) generally improved better than grade IV after heavy rainfalls. However, DO and T-P were the parameters that deteriorated the WQI. Ignition loss (IL), COD, T-N, and T-P of sediments had distribution of 1.44 ± 1.01%, 0.35 ± 0.16%, 43 ± 63 mg/kg, and 10.9 ± 21.9 mg/kg, respectively. These were several times lower than the annual averages of IL, T-N, and T-P in 2017 before the dredging project was conducted in the first half of 2018.

Effects of Gamma-Irradiation on Cooking Property of Black Soybeans (검정콩의 조리특성에 관한 감마선조사의 영향)

  • 김종군
    • Journal of the Korean Home Economics Association
    • /
    • v.30 no.3
    • /
    • pp.119-129
    • /
    • 1992
  • Black soybeans were gamma-irradiated at dost levels of 0, 2., 5, 10 and 20 kGy, and stored at room temperature for the experiments associated with cooking quality. The degree of cooking of soybeans in boiling water at 98-10$0^{\circ}C$ has been determined by measuring the maximum cutting force of cotyledon. The cutting force to reach a complete cooking was about 120~130g/g. Irradiation at 2.5~20kGy caused the reduction of cooking time in black soybeans by 30~60% compared to the nonirradiated control, and the cooking rate constant of the irradiated samples was higher than that fo the nonirradiated control sample. These results were similarly found in the stored samples for one year at room temperature after irradiation. Color characteristics of cooked samples showed no significant difference between the nonirradiated control and 5 kGy-irradiated sample. After complete cooking of black soybeans, there were not significant in the organoleptic qualities between the nonirradiated and irradiated samples.

  • PDF

Realtime monitoring system for marine red tide and water-bloom based on Internet of Things (사물인터넷 기반의 해양 적·녹조 실시간 모니터링 시스템 설계)

  • Kim, Nam Ho
    • Smart Media Journal
    • /
    • v.5 no.1
    • /
    • pp.130-136
    • /
    • 2016
  • In this paper, the real time monitoring system for the abnormal state of marine algae does not detect the plankton which may directly cause the red tide or the water bloom. But checks both oxygen reduction and nitrogen reduction in water, which indicates the characteristics of zooplankton and phytoplankton respectively, and this system makes a module that monitors in real time the temperature and the illumination of the water, which are indirect factors, with sensors placed in and outside the water, and this module transmits signals periodically at specific intervals to a sever that builds up data base, and the data collected in these ways will be analyzed and compared with the standard data from Ministry of Oceans and Fisheries, and then these data will be made the adequate form of information to be provided to the users as visual information, thus, this system intends to make a red tide and water bloom monitoring system tailored for individual fish farm businesses that has local characteristics and can quickly operate outside working hours, which differs from the existing wide area detecting and monitoring systems.

Determination of Water-holding Capacity of Porcine Musculature Based on Released Water Method Using Optimal Load

  • Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.38 no.4
    • /
    • pp.823-828
    • /
    • 2018
  • The purpose of this study was to evaluate the suitability of the released water (RW) method for measuring water-holding capacity (WHC) by pressure and filter-paper absorption within two thin plastic films. One hundred fifty pork loins with considerable variations in WHC (three pork qualities: PSE, pale, soft, and exudative; RFN, reddish-pink, firm, and nonexudative; and DFD, dark, firm, and dry; 50 pork loins in each pork quality group) were used to measure drip loss (DL)% and RW % after applying different loads (1.5, 2.0, 2.5, 3.0 and 3.5 kg). Percentages of DL and RW were significantly (p<0.05) different among pork quality groups. The RW % of 2.5 kg load sample was significantly (p<0.05) higher than that of 2.0 kg or 1.5 kg load sample. However, there were no significant (p>0.05) differences in RW % among 2.5 kg, 3.0 kg, and 3.5 kg load samples for all three pork quality groups. The RW % was highly and positively correlated (r>0.95; p<0.001) with DL %. The highest correlation was observed between DL % and RW % of 2.5 kg load sample (r=0.97; p<0.001). Among all RW loads within each quality groups, the highest correlation between DL % and RW % was observed for 2.5 kg load sample (r=0.43, 0.66, and 0.46 for PSE, RFN and DFD quality groups, respectively, p<0.001). These results imply that applying 2.5 kg load is the best for determination of RW %. It is recommended as a reference method to assess DL % of pork muscles.

Analysis of Evaluation Possibility of Fly Ash Fineness Using Hydrometer (Hydrometer에 의한 플라이애시의 분말도 평가 가능성 분석)

  • Song, Heung-Ho;Han, Cheon-Go
    • Journal of the Korea Institute of Building Construction
    • /
    • v.17 no.2
    • /
    • pp.119-125
    • /
    • 2017
  • Due to the processing cost, there were some reports on distribution of unrefined fly ash. Hence, in this research, the possibility of fly ash quality evaluation by measuring the density of various qualities of coal ash suspensions with hydrometer. According to the experimental results, the appropriate test conditions were determined with 1,000cc capacity mass cylinder for 1,000cc of water with 100g of fly ash. From the evaluating performance of various coal ashes, based on a good correlation between fineness and quality of the coal ashes, it was possible to evaluate the quality of coal ash by measuring different density of suspension with hydrometer. In this research conditions, the suggestable measuring time of density variation was three minute for fly ash quality related with fineness.

A comparative study on the accuracies of resin denture bases and metal denture bases

  • Park Hwee-Woong;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.250-259
    • /
    • 2001
  • Since the late 1930s, acrylic resins have been the materials of choice for the fabrication of complete denture bases. It has excellent esthetic properties, adequate strength, low water sorption, and low solubility. But acrylic resin has disadvantage of processing shrinkage that reduces denture retention and accuracy of denture occlusion. Metals also have been used in denture base material. Metals used in denture bases display excellent strength and dimensional stability. The major disadvantages associated with metal denture bases include increased cost, difficulty in fabrication, compromised esthetic qualities, and inability to re-base. The purpose of this study is to compare the artificial tooth movements of complete dentures with resin bases and metal bases after curing, deflasking, polishing immersion in water for 1 week and 4 weeks. Twenty-four maxillary complete resin denture bases with artificial teeth were fabricated. Twelve of them were resin based and other twelve of them were metal based. Fine crosses were marked on the incisal edges of right central incisors and distobuccal cusps of be second molars. Measurements were done for the changes of distances of reference points at the time of wax denture, after deflasking after decasting after polishing after immersion in water for 1 week and 4 weeks Meaurements were done to the accuracy of 0.001mm with a measuring microscope. The results were as follows : 1. Metal base showed significantly less tooth movement than resin base after curing and decasting (p<0.01). 2. Metal base showed significantly less tooth movement than resin base after polishing (p<0.01). 3. After immersion in water for 1 week and 4 weeks, metal base showed less movement than resin base. Difference was significant for anterior-posterior distances (p<0.01), but not significant for molar-to-molar distance (p>0.01). 4. 1 week and 4 weeks of immersion failed to compensate the initial processing shrinkage of metal and resin bases (p>0.01).

  • PDF

Quality Evaluation and Mix Proportion of Antiwashout Underwater Concrete with Mineral Admixture (광물질 혼화재료를 사용한 수중불분리성 콘크리트의 배합 및 품질평가 방안 검토)

  • Park, Yong Kyu;Kim, Hyun Woo;Yoon, Ki Woon
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.679-686
    • /
    • 2014
  • In this research, the mix proportion of the antiwashout underwater concrete with the mineral admixture was evaluated. It can reduce the amount used of the antiwashout admixture (hereinafter referred to as "AWA") and satisfy the properties of concrete. In addition, the review for the difference of the test and practical affairs were conducted. Optimized unit quantity of water of antiwashout underwater concrete and the amount used of AWA was revealed by $190kg/m^3$, 0.9%/W, respectively. In particularly, the mix design is reduced by 5% than the W/B of target strength even though the W and AWA reduced. Therefore, it will have the economical feasibility and qualities including the material separation, resistance characteristic and compressive strength, and etc. The stable value was shown in 1 point of minute passed in the measurement of the turbidity amounts using the turbidimeter after the checker insertion. However, it needs to be reviewed for the interrelationship between turbidity measuring machine and KCI-AD102 standard method. There were no significant differences of compressive strength of specimens in the water depending on the production methods.

COMPARATIVE STUDIES OF THE ADHESIVE QUALITIES OF POLYCARBOXYLATE CEMENTS (카복실레이트계 시멘트의 접착력에 관한 비교 연구)

  • Lee, Han-Moo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.17 no.1
    • /
    • pp.23-34
    • /
    • 1979
  • In this study, the adhesive strength of three commercial polycarboxylate cements to ten types of dental casting alloys, such as gold, palladium, silver, indium, copper, nickel, chromium, and human enamel and dentine were measured and compared with that of a conventional zinc phosphate cement. The $8.0mm{\times}3.0mm$ cylindrical alloy specimens were made by casting. The enamel specimens were prepared from the labial surface of human upper incisor, and the dentine specimens were prepared from the occulusal surface of the human molar respectively. Sound extracted human teeth, which had been kept in a fresh condition since, extraction, were mounted in a wax box with a cold-curing acrylic resin to expose the flattened area. The mounted teeth were then placed in a Specimen Cutter (Technicut) and were cut down under a water spray, and then the flat area on the all specimens were ground by hand with 400 and 600 grit wet silicone carbide paper. Two such specimens were then cemented together face-to-face with freshly mixed cement, and moderate finger pressure was applied to squeeze the cement to a thin and uniform film. All cemented specimens were then kept in a thermostatic humidor cabinet regulated at $23{\pm}2^{\circ}C.$ and more than 95 per cent relative humidity and tested after 24 hours and 1 week. Link chain was attached to each alloy specimen to reduce the rigidity of the jig assembly, and then all the specimens were mounted in the grips of the Instron Universal Testing Machine, and a tensile load was delivered to the adhering surface at a cross head speed of 0.20 mm/min. The loads to which the specimens were subjected were recorded on a chart moving at 0.50 mm/min. The adhesive strength was determined by measuring the load when the specimen separated from the cement block and by dividing the load by the area. The test was performed in a room at $23{\pm}2^{\circ}C.$ and $50{\pm}10$ per cent relative humidity. A minimum of five specimens were tested each material and those which deviated more than 15 per cent from the mean were discarded and new specimens prepared. From the experiments, the following results were obtained. 1) It was found that the adhesive strength of the polycarboxylate cement to all alloys tested was considerably greater than that of the zinc phosphate cement. 2) The adhesive strength of the polycarboxylate cements was superior to the non precious alloys, such as the copper, indium, nickel and chromium alloys, but it was inferior to the precious gold, silver and palladium alloys. 3) Surface treatment of the alloy was found to be an important factor in achieving adhesion. It appears that a polycarboxylate cement will adhere better to a smooth surface than to a rough one. This contrasts with zinc phosphate cements, where a rough helps mechanical interlocking. 4) The adhesion of the polycarboxylate cement with enamel was found superior to its adhesion with dentine.

  • PDF

Research on the Methods and Proper Provisions for Rotational Irrigation (윤환관개방법과 적정시설 연구)

  • 유한열
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.1
    • /
    • pp.2191-2205
    • /
    • 1971
  • In this research, Nong-rim No. 6 was adopted as a test variety of rice. Rice seedlings were transplanted on June 14, 1970. Roots were settled into soil on June 20 and a total number of days irrigated of $21cm{\times}21cm$ and an area of $9.9m^2$ for a test plot were accepted, planting 70 stumps of rice in a test plot. The soil in test plots are classified by soil test as oam, and its chemical contents are as shown in Table 3. Irrigation water was secured by pumping from the Sudun stream that originates at the Suho reservoir. Accordingly, the qualities of irrigation. water are considered to be the same as those of water stored in the Suho reservoir. There were 54 days of intermittent rainfalls in total during the whole 110-day period of irrigation. As a result, it is likely that the growth of rice plants was influenced by rainfall at a comparatively great degree. In order to measure the amounts of water consumption, infiltrometers, measuring devices for the decreases of water depths and lycimeters were provided. As a result of measurements, an average daily rate of infiltration was observed to be 14mm/day. It is expected from this research that the effect of increased yield will be secured by supplying optimum amounts of water for irrigation on proper times, and that the amounts of water consumption for irrigation can be saved by applying suitable irrigation methods. The test results obtained are summarized as follows: 1. Yields produced in the test plots of continuous irrigation are lower than those in the test plots of rotational irrigation, i.e., yields produced at the test plots irrigatied once in a period of 8 days are higher by 27% in average than those produced at test plots of continuous irrigation. 2. The amounts of irrigation water for test plots, which have a clay layer of 9cm in thickness and vynil diaphragm without holes, are saved by about 52% in comparison with ordinary test plots. 3. Ears are sprouted 5 days earlier at continuous irrigation plots as compared with other test plots. 4. It seems that there are growing stages of rice plants such as those of forming and sprouting of ears, in which the amounts of irrigation water are consumed more in comparison with the other stages. Therefore, it may be possible to increase of decrease the amount of irrigation water, according to the growing stage of rice plant, so as to save irrigation water.

  • PDF

Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams (유리선량계를 이용한 고에너지 전자선 측정 이용 가능성에 관한 연구)

  • Son, Ki-Hong;Jung, Hai-Jo;Shin, Sang-Hun;Lee, Hyun-Ho;Lee, Sung-Hyun;Kim, Mi-Sook;Ji, Young-Hoon;Kim, Kum-Bae
    • Progress in Medical Physics
    • /
    • v.22 no.1
    • /
    • pp.52-58
    • /
    • 2011
  • Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; $R^2$ of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was ${\pm}1.2%$. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from $0^{\circ}$ to $90^{\circ}$ and GD's maximum response differencewas 14% lower at 180o. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within ${\pm}1.5%$ except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.