• Title/Summary/Keyword: measuring volume

Search Result 795, Processing Time 0.028 seconds

Implementation of the Blood Pressure and Blood Flow Variation Rate Detection System using Impedance Method (임피던스법을 이용한 혈압 및 혈류 변화량 검출 시스템 구현)

  • Ro, Jung-Hoon;Bae, Jin-Woo;Ye, Soo-Young;Shin, Bum-Joo;Jeon, Gye-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1926-1938
    • /
    • 2009
  • In this study, detection system of the blood flow variation rate was implemented using the variation effect of bio electric impedance at time of the blood pressure measurement by means of impedance method. The blood pressure measurement was performed by the oscillometric method. The mean arterial pressure was calculated using maximum amplitude algorithm. The systolic and diastolic pressure were estimated by establishment of the various characteristic ratio according to mean arterial pressure range. Alternative static current source and lock_in amplifier were introduced to impedance measurement. The variation of blood volume was measured using variation bio impedance according to induced cuff pressure at measuring area.

Measurement of the Apparent Density of Shred and Void Fraction in a Tobacco Column

  • Oh, In-Hyeog;Jeh, Byong-Kwon;Ra, Do-Young;Kwak, Dae-Keun;Kim, Byeoung-Ku;Jo, Si-Hyung;Rhee, Moon-Soo
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.29 no.1
    • /
    • pp.23-29
    • /
    • 2007
  • The measurement of physical properties such as apparent density and void fraction of tobacco materials, which is so bulky, is a main theme with regard to tobacco process, quality control, cigarette combustion and smoke generation. Except Solution Impregnation Method, there was no alternative method for measuring those properties in the porous material so far. However, experimental processes of that method are so complicated as to cost much time and labor, the main solution such as mercury to apply to the method is usually very hazard. Therefore, we had developed a new method to determine them easily in our other paper by the mathematical equations derived from the Ergun equation for the purpose of it, and then already evaluated our method through applying some basic data from Muramatsu et at. (1979) with regard to our developed equations. Then, we found our method best fit to experimental one (Oh et al., 2001). In this study we tried to establish our method to conveniently determine those physical properties. Especially, we have focused on the development the easy way to measure surface area and the volume of single shred in a tobacco column. As a result of that, we found that the computer image analyzer was best fit for it. Then, we have finally determined apparent density and void fraction for our domestic tobacco shred.

In-site Processing and Mechanical Properties of Ti/TiB Composites (반응생성에 의한 Ti/TiB 복합재료의 제조와 기계적 성질)

  • Jeong, Hui-Won;Lee, Yong-Tae
    • Korean Journal of Materials Research
    • /
    • v.9 no.3
    • /
    • pp.307-314
    • /
    • 1999
  • The effect of manufacturing variables, such as reactant powder$(TiB_2, B_4C)$, sintering temperature, and sintering time has been investigated on the microstructure and the mechanical properties of in-situ processed Ti/TiB composites. The mechanical properties were evaluated by measuring the compressive yield strength. The compressive yield strength of the in-situ processed composites was higher than that of the Ti-6AI-4V. The compressive yield strength of the composite made with TiE, reactant powder was higher than that of $B_4C$, mixed at the same volume fraction of reinforcement. It is because bonding nature between the matrix and the $TiB_2$, reactant powder was more strong than that of the other materials. It was proven by the examining the crack propagation path.

  • PDF

Cure Monitoring of Epoxy Resin by Using Fiber Bragg Grating Sensor (광섬유 브래그 격자 센서를 이용한 에폭시 수지의 경화도 모니터링)

  • Lee, Jin-Hyuk;Kim, Dae-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.211-216
    • /
    • 2016
  • In several industrial fields, epoxy resin is widely used as an adhesive for co-curing and manufacturing various structures. Controlling the manufacturing process is required for ensuring robust bonding performance and the stability of the structures. A fiber optic sensor is suitable for the cure monitoring of epoxy resin owing to the thready shape of the sensor. In this paper, a fiber Bragg grating (FBG) sensor was applied for the cure monitoring of epoxy resin. Based on the experimental results, it was demonstrated that the FBG sensor can monitor the status of epoxy resin curing by measuring the strain caused by volume shrinkage and considering the compensation of temperature. In addition, two types of epoxy resin were used for the cure-monitoring; moreover, when compared to each other, it was found that the two types of epoxy had different cure-processes in terms of the change of strain during the curing. Therefore, the study proved that the FBG sensor is very profitable for the cure-monitoring of epoxy resin.

Evaluation of Characteristics of Tack Coat for Porous Pavement using Direct Shear Test (직접 전단 실험을 통한 배수성포장용 택코트 특성 평가)

  • Kim, Nak-Seok;Hong, Eun-Cheol;Jo, Shin-Haeng
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.27-32
    • /
    • 2009
  • The main objective of this study is to develop a test for measuring the bond shear strength between pavement layers. The research is also conducted to evaluate tack coat materials and application rate in porous pavement. The experiment includes using two types of emulsions (RSC-4, Modified Emulsion) and a asphalt binder type (HM-1). HM-1 was developed to be applied in porous pavement. The bond shear strengths were measured by a direct shear type device under various test conditions. The shear strength may not be appropriate in the evaluation of the bond shear strength, while the toughness of the test may be useful. In case of the tack coat application rate in porous pavement, RSC-4 has to be used a minimum amount of $0.8l/m^2$ and modified emulsion asphalt has to be applied a volume of use $0.5{\sim}0.6l/m^2$. HM-1, asphalt cement type, is far stronger bond shear strength than emulsified asphalt tack coat and had showed the excellent trackless property.

Ultrasound Attenuation in the Assessment of Bone Mineral Density and Elastic Modulus of Human Trabecular Bone

  • Han, S.M.;Kim, M.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 1998
  • The objective of this study was to re-evaluate ultrasound attenuation as an indicator of bone properties. Ultrasound attenuation(BUA), were measured in the three orthogonal directions of trabecular bone cubes, Measurements of bone mineral density(BMD) were made using quantitative computed tomography and apparent density by weighing bone specimens and measuring their volume. Ultrasonic modulus was calculated from the standard equation with apparent density and ultrasound velocity. Ultrasound attenuation at a frequency of 0.5 MHz and BUA were correlated with BMD and ultrasonic modulus in the anterior/posterior, medial/lateral, and superior/inferior directions. Analysis of correlations demonstrated that attenuation at 0.5 MHz was superior to BUA in describing both BMD and elastic modulus of trabecular bone. This result may be used to improve current ultrasound diagnostic techniques for assessing bone status.

  • PDF

A Survey Study on Urinary incontinence of Adult Women (일부지역 여성의 스트레스성 요실금 경험에 대한 조사연구)

  • Kim Ae-Kyung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.257-268
    • /
    • 1998
  • The purpose of this study were to identify the characteristics of urinary incontinence in adult women and to identify it's relating factors, daily living and sexual problem related urinary incontinence. Subjects were 60 community dwelling women in the age of 25-60 years old at 1 cities in Korea. The data were collected from January 1988 to May. 1998. Subject were interviewed with structured questionnaire. Questionaire was composed of item of general characteristics, obstetrical characteristics, measuring tool of severity of urinary incontinence, discomfort due to urinary incontinence. The data were analyzed with SAS program, descriptive statistics, T-test, ANOVA test. The results of study were as followings. 1) Most of incontinence women were mildly incontinent subjects(mean=7.40). 2) The common activity related to the urinary incontinence were coughing, sneezing, laughing aloudly exercising. 63.5% of women reported small volume accidents of only 1 to 2 drops. 3) The incidence of urinary incontinence was significantly higher in woman who had more pariety and older age of last delivery, menopause, itching sense of vagina. 4) 73.3% of the episodic urinary incontinence were not treated because the felt that urinary incontinence was not disease(70.4%) was shamful(18.1%), was incurable inspite of treatement attempt(4.5%). 5) Daily living problem related to urinary incontinence were as follows : Voiding before going out(66.6%), odor of urine(10.0), frequent underwear change.(88.3%). 6) Sexual intercourse problem related to urinary incontinence were as follows : Pain during sexual intercourse(30.0%), sexual life trouble,(8.3%), urine leakage.(11.7%) The results indicate that urinary incontinence is common in adult women. Health care provider should develop and provide adequate nursing intervention for prevention and early treatment of urinary incontinence.

  • PDF

A Study on Effect of Flex Additions for Selecting the Process Parameters in GMA Welding processes (GMA 용접공정에서 공정변수 선정을 위한 플럭스 첨가에 관한 연구)

  • Kim, In-Ju;Kim, Jun-Ki
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.17-22
    • /
    • 2011
  • As the quality of a weld joint is strongly influenced by process parameters the welding process, an intelligent algorithms that can predict the bead geometry and shape to accomplish the desired mechanical properties of the weldment should be developed. In this study, prepared by ${\Phi}1.6mm$ GMA welding of metal wire nose Advice jowelui 350A 600A grade level inverter welder and DAIHEN SCR's were carried out using welding. Welding conditions were 5.5m/min wire feed rate the welding current is rapidly transmit approximately 260A, welding voltage was about 30V. CTWD a 22mm, shielding gas was Ar 20L/min and the welding speed was a 240mm/min. Using data collected during welding equipment welding current and welding voltage waveform was analyzed by measuring the volume of the transition mode. Addition of $CaCO_3$ as a loss of the spread of the weld bead dilution rate decreased, suggesting that, GMA in the overlay welding bead shape control, dilution control and may be used as a welding flux is considered. Stabilizing effect of the arc by the Ca-containing $CaF_2$, $CaCO_3$, $CaMg(CO_3)_2$, respectively, welding flux 0.1wt.% added GMA welding and weld overlay were evaluated with dilution, $CaF_2$, and $CaMg(CO_3)_2$ added to the dilution of Seemed to increase.

Liquid chromatography-tandem mass spectrometric analysis of oleracone D and its application to pharmacokinetic study in mice

  • Lim, Dong Yu;Lee, Tae Yeon;Lee, Jaehyeok;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.193-201
    • /
    • 2021
  • We have demonstrated a sensitive analytical method of measuring oleracone D in mouse plasma using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Oleracone D and oleracone F (internal standard) in mouse plasma samples were processed using a liquid-liquid extraction method with methyl tertbutyl ether, resulting in high and reproducible extraction recovery (80.19-82.49 %). No interfering peaks around the peak elution time of oleracone D and oleracone F were observed. The standard calibration curves for oleracone D ranged from 0.5 to 100 ng/mL and were linear with r2 of 0.992. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. The pharmacokinetics of oleracone D following intravenous and oral administration of oleracone D at doses of 5 mg/kg and 30 mg/kg, respectively, were investigated. When oleracone D was intravenously injected, it had first-order elimination kinetics with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 0.95 %, with multi-exponential kinetics. The low aqueous solubility and a high oral dose of oleracone D may explain the different elimination kinetics of oleracone D between intravenous and oral administration. Collectively, this newly developed sensitive LC-MS/MS method of oleracone D could be successfully utilized for investigating the pharmacokinetic properties of this compound and could be used in future studies for the lead optimization and biopharmaceutic investigation of oleracone D.

A Study on the Development of Wearable Smart Fashion Product - Focused on the Construction of Optimized Functionalities for Particular Needs - (웨어러블 기능성 스마트 패션제품 개발 연구 - 특정사용자를 위한 특수한 기능성 구현을 중심으로 -)

  • Lee, Hyunseung;Lee, Jaejung
    • Fashion & Textile Research Journal
    • /
    • v.21 no.2
    • /
    • pp.133-140
    • /
    • 2019
  • This study developed smart fashion prototypes that provide utilitarian functionality by combining Fashion and Electronics regarding the IT focused convergence tendency in modern industries. A convergence R&D workshop was performed by Fashion design majors and Engineering majors for the study. As a result, 5 functional smart fashion prototypes were developed and the outline of each prototype are as follows. The $1^{st}$ prototype, 'Hidden Camera Detecting Coat' focused on gender-related crimes. The coat uses infrared lighting and LED technologies to provide a function to detect hidden cameras in suspicious public spaces such as toilets. The $2^{nd}$ prototype, 'Heating-massage Suit' targeted patients with musculoskeletal system difficulties. The suit uses heating and vibration technologies to provide a heating massage treatment for patients with ongoing difficulties in their daily lives. The $3^{rd}$ prototype is an air-bag jacket to prevent sexual molestation on public transportation. The jacket extends its volume through pressure sensing, air compressing, motors and 3D-printing technology to secure the wearer's personal preventive space between the user's body and others. The $4^{th}$ prototype is a town wear for people suffering from synesthesia. People with synesthesia inadvertently see colors when exposed to certain sounds. This town wear uses sound sensing, air compressing, motors and 3D-printing technology to provide sound prevention and a comfortable sound playing function. The $5^{th}$ prototype is a set of a vest and a gloves for visually impaired people. The vest and gloves uses DMS, voice playing, vibration technology to provide distance measuring and warning functions.