• Title/Summary/Keyword: measuring vessel

Search Result 155, Processing Time 0.032 seconds

Experiences of Neuroform Stent Applications for Ruptured Anterior Communicating Artery Aneurysms with Small Parent Vessel

  • Yun, Jung-Ho;Cho, Chun-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.48 no.1
    • /
    • pp.53-58
    • /
    • 2010
  • Objective : The purpose of this study was to review the safety and durability of aneurysms treated with stent-assisted coiling of ruptured anterior communicating artery aneurysms with small parent vessels (< 2.0 mm). Methods : Retrospective review of all ruptured aneurysm treated with stent assisted endovascular coiling between March 2005 and March 2009 at our institution was conducted. We report 11 cases of the Neuroform stent placement into cerebral vessels measuring less than 2.0 mm in diameter (range, 1.3-1.9 mm) in anterior cerebral artery. Clinical follow-up ranged from 3 to 12 months and imaging follow-up was performed with cerebral angiography at 6 months and 12 months after discharge. Results : Complete occlusion was achieved in 10 patients, and a remnant neck was evident in one. No stent displacement or no dislodgement occurred during stent placement. There was no evidence of thromboembolic complication, arterial dissection and spasm during procedure. We performed follow-up angiography in all patients at 6 months and/or 12 months from the first procedure. The follow-up angiographic data showed successfully results except one in-stent stenosis case. All patients improved clinical performances except one patient with severe vasospasm who showed poor clinical condition initially. Conclusion : We have safely and successfully treated 11 vessels smaller than 2.0 mm in diameter with self-expanding stents with good short and intermediate term results. More clinical data with longer follow-ups are needed to establish the role of stent-assisted coiling in ruptured aneurysms with small parent vessels.

Fatigue Crack Growth Characteristics of the Pressure Vessel Steel SA 508 Cl. 3 in Various Environments

  • Lee, S. G.;Kim, I. S.;Park, Y. S.;Kim, J. W.;Park, C. Y.
    • Nuclear Engineering and Technology
    • /
    • v.33 no.5
    • /
    • pp.526-538
    • /
    • 2001
  • Fatigue tests in air and in room temperature water were performed to obtain comparable data and stable crack measuring conditions. In air environment, fatigue crack growth rate was increased with increasing temperature due to an increase in crack tip oxidation rate. In room temperature water, the fatigue crack growth rate was faster than in air and crack path varied on loading conditions. In simulated light water reactor (LWR) conditions, there was little environmental effect on the fatigue crack growth rate (FCGR) at low dissolved oxygen or at high loading frequency conditions. While the FCGR was enhanced at high oxygen condition, and the enhancement of crack growth rate increased as loading frequency decreased to a critical value. In fractography, environmentally assisted cracks, such as semi-cleavage and secondary intergranular crack, were found near sulfide inclusions only at high dissolved oxygen and low loading frequency condition. The high crack growth rate was related to environmentally assisted crack. These results indicated that environmentally assisted crack could be formed by the Electrochemical effect in specific loading condition.

  • PDF

Analysis for Motion Sickness Incidence according to Measuring Point in 30ton Class Customs Patrol Type Vessel (30ton급 세관감시정의 측정위치에 따른 멀미도(MSI) 해석)

  • Park, Geun-Hong;Lee, Gyoung-Woo;Cho, Dae-Hwan;Seo, Gwang-Cheol;Han, Seung-Jae
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2017.04a
    • /
    • pp.255-255
    • /
    • 2017
  • 본 연구에서는 고속으로 활주하는 선박의 승선감 향상 및 운항성능 특성 연구를 위해 30ton급 세관감시정의 측정위치에 따른 멀미도 해석을 수행하였다. 특히, 관공선내의 선원들은 유사시에 신속 정확한 판단이 요구되므로 측정위치에 따른 멀미도의 영향에 대한 연구가 필요할 것으로 판단하였다. 멀미도 평가는 ISO 2631-3(1985)을 기준으로 하였다. 평가 기준은 30분, 2시간, 8시간 이후 성인 100명 중 10명이 멀미를 한다는 국제표준 지표이며 조우주파수와 수직가속도 성분으로 나타난다. 멀미도 해석은 Maxsurf Motion 모듈을 이용하였다. 30ton급 세관감시정은 고속활주형 선박의 특성을 갖기 때문에 선속에 따른 트림변화를 고려하였다. 입사각은 선체 전 방향에서의 영향을 고려한 범위로 선정하였다. 선속의 경우 선박 운용상태(정박, 저속, 고속)을 고려하여 적용하였다. 측정위치의 경우 선원들의 주 활동 구역을 고려하여 선정하였다. 해석결과 멀미도의 영향은 30knot, $180^{\circ}$의 경우에 가장 크게 분석되었다.

  • PDF

Correction Methods and Validation for Environmental Conditions in the Ice Field Trials (빙해역 시운전 해석을 위한 환경조건 보정 방법 및 검증)

  • Kim, Hyun Soo
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.2
    • /
    • pp.117-127
    • /
    • 2019
  • Vessel's ice speed performances will be verified in ice sea trial but environmental conditions of ice fields are changeable according to the weather condition of ice trial area. Speed performance has to correct in the no wind, wave and current etc. after sea trial. Especially finding ice fields which is exact the same as owner's ice thickness and strength requirements is not easy. Therefore speed correction according to environment condition has to be done after sea trial measurements. Correction methods for ice thickness, ice strength, wave, wind and ship draft, trim, ice drift etc. are checked in ice sea trial based on literature review such as ISO standard, ITTC recommendation, journal papers and proceedings of conferences. Possibility of application for current and ice drift correction in ice field are discussed and measuring schemes and procedures of correction methods are described in this paper. All of correction schemes are calculated for 'Araon' which is ice breaking research vessel with Arctic and Antarctic ice field test results. Analyzed results shows that Araon is satisfied with her official ice speed performance of 3 knots with 10MW power at 1m ice thickness, 570kPa ice flexural strength.

Sesamin attenuates neuronal damage through inhibition of microglial activation following global cerebral ischemia in rats

  • Kong, Minjung;Hong, Sung In
    • The Korea Journal of Herbology
    • /
    • v.28 no.2
    • /
    • pp.1-7
    • /
    • 2013
  • Objectives : Sesamin, a major lignan in sesame seeds, has been reported to have neuroprotective effects against in vitro ischemia and in vivo MCAo-reperfusion cerebral ischemia model, however, there is no reports in an in vivo global cerebral ischemia model. The purpose of the study was to investigate the neuroprotective effect of sesamin in global cerebral ischemia induced by four-vessel occlusion (4-VO) in rats through inhibition of microglial activation in this model. Methods : The neuroprotective effects were investigated using a 10 min of 4-VO ischemia rat model by measuring intact pyramidal neurons in the CA1 region of the hippocampus using Nissle staining. The antiinflammatory or reducing neurotoxicity effect was investigated using immunohistochemisty, RT-PCR and western blot analysis of inflammatory or neurotoxic mediators. Results : Intraperitoneal injection of sesamin at doses of 0.3, 1.0, 3.0, and 10.0 mg/kg at 0 min and 90 min after ischemia conferred 26.6%, 30.1%, 42.5%, and 30.5% neuroprotection, respectively, compared to the vehicle-treated control group. A 3.0 mg/kg dose of sesamin inhibited microglia activation and consequently, cyclooxygenase-2, inducible nitric oxide, and interleukine-$1{\beta}$ expressions at 48 h after reperfusion. Conclusions : Sesamin protects neuronal cell death through inhibition of microglial activation or the production of neurotoxic metabolites and proinflammatory mediators by microglia such as COX-2, iNOS and IL-$1{\beta}$ in global cerebral ischemia.

The Study of Compatibility for Method of Analysis of Nonlinear Characteristics of Blood Flow of Peripheral in Rabbit (토끼에 있어서 말초혈류운동의 비선형특성분석방법의 적합성에 관한 연구)

  • 남상희;최준영;이상훈
    • Progress in Medical Physics
    • /
    • v.8 no.1
    • /
    • pp.75-82
    • /
    • 1997
  • The human physiological systems are so complex and irregular dynamics. Dynamics of peripheral blood vessel, in particular, have quite sensitive and complex. Before, the linear analytic method have been used to analyze the system. But, the method have many problems to predict the following results. In the other hand, the nonlinear analytic method, chaotic time series analysis method, is suitable for measuring complex, vary system. In this study, the scalar data of the blood flow of peripheral blood vessel of rabbits, in accordance with injection of glucose, was obtained and redefined as multi-dimensional vectors, with time-series analytic methods. This study also intended to confirm that the peripheral blood flow is chaotic dynamics and evaluate the availability of non-linear analytic method. As a result, the existing FFT, and mean could show the difference of blood flow of peripheral blood vessel by injection of glucose, but the nonlinear analytic method could show the definite difference. The hemodynamics is a chaotic phenomenon.

  • PDF

A Clinical Anatomic Study of Internal Mammary Perforators as Recipient Vessels for Breast Reconstruction

  • Baek, In-Soo;You, Jae-Pil;Rhee, Sung-Mi;Son, Gil-Su;Kim, Deok-Woo;Dhong, Eun-Sang;Park, Seung-Ha;Yoon, Eul-Sik
    • Archives of Plastic Surgery
    • /
    • v.40 no.6
    • /
    • pp.761-765
    • /
    • 2013
  • Background Partially resecting ribs of the recipient site to facilitate easy anastomosis of the internal mammary vessels to free flaps during breast reconstruction can cause chest wall pain or deformities. To avoid this, the intercostal perforating branches of the internal mammary vessels can be used for anastomosis. The purpose of this study was to investigate the location and size of the internal mammary perforator vessels based on clinical intraoperative findings and to determine their reliability as recipient vessels for breast reconstruction with microsurgical free tissue transfer. Methods Twelve patients were preoperatively screened for the presence of internal mammary perforators using Doppler tracing. After modified radical mastectomy was performed by a general surgeon, the location and size of the internal mammary perforator vessels were microscopically investigated. The external diameter was examined using a vessel-measuring gauge from a mechanical coupling device, and the distance from the mid-sternal line to the perforator was also measured. Results The largest arterial perforator averaged 1.5 mm, and the largest venous perforator averaged 2.2 mm. Perforators emerging from the second intercostal space had the largest average external diameter; the second intercostal space also had the largest number of perforators arising from it. The average distance from the mid-sternal line to the perforator was 20.2 mm. Conclusions Internal mammary perforators presented consistent and reliable anatomy in this study. Based on these results, the internal mammary perforators appear to have a suitable diameter for microvascular anastomosis and should be considered as an alternative recipient vessel to the internal mammary vessel.

Field Experiments and Analysis of Drift Characteristics of Small Vessels in the Coastal Region off Busan Port (부산항 연안해역에서의 소형선박 표류 거동특성 관측 및 분석)

  • Kang, Sin-Young;Lee, Mun-Jin
    • Journal of Navigation and Port Research
    • /
    • v.26 no.2
    • /
    • pp.221-226
    • /
    • 2002
  • To provide reliable data for drift prediction models, field experiments were carried out in the coastal region off Busan port. Four different size of vessels(10, 30, 50, 90G/T ton) were deployed for the experiment. Among them G/T 50ton class vessel was equipped with instruments measuring the currents, winds, headings and trajectory data. In the rest of vessels only the position data were recorded for the purpose of target divergence study. The trajectories of each vessel were measured by DGPS(Differential Global Positioning System) and collected by APRS(Automatic Position Reporting System). The experiment was done in wind of 2~10m/s and current of 0.5~1.5m/s. The leeway was derived by subtracting surface current velocity from target drifting velocity. The leeway rate of G/T 50ton vessel was found to be about 3.6% and the computed leeway speed equation was $U_L$=0.042 W - 0.034. The processed leeway angle data were deflected by $-30^{\circ}$~$40^{\circ}$ from the direction of ship drift.

Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography (전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석)

  • Hong, Kyung-Min;Kang, Young-June;Choi, In-Young;Ahn, Yong-Jin;Yoon, Suk-Bum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

A Study of Hull Stress Monitoring System considering Thermal Effect

  • Shim, Chun-Sik;Kang, Joong-Kyoo;Heo, Joo-Ho
    • Journal of Navigation and Port Research
    • /
    • v.32 no.2
    • /
    • pp.121-126
    • /
    • 2008
  • This paper presents hull stress monitoring system installed in LNGC damaged by a Typhoon Elongation/contraction of removed areas has been assessed in terms of possible residual stress that will take place in replaced blocks when the applied load is removed. The bending moment of a vessel changes actually in terms of loss of longitudinal members and the change of weight distribution in repair procedure. The change of bending moment affects mainly in hull stress of longitudinal members. Hull stress monitoring system was installed on upper deck to prove LNGC stable in the criteria to be less than 40MPa during the period of repair procedure. A temperature measuring system was also installed to exclude the additional stress due to thermal effect from the measured hull stress. As a result, the hull stress was modified with the data measured by the temperature measuring system. This hull stress considering thermal effect was used as a guide stress to check the safety of LNGC during the period of repair procedure.