• Title/Summary/Keyword: measuring mean of quality

Search Result 115, Processing Time 0.028 seconds

Evaluation of the Performance of Woodchip-filled Infiltration Trench Treating Stormwater from Highway (고속도로 강우유출수 처리를 위한 우드칩 충진 침투도랑의 성능평가)

  • Park, Kisoo;Kang, Heeman;Kim, Youngchul
    • Journal of Wetlands Research
    • /
    • v.18 no.2
    • /
    • pp.183-193
    • /
    • 2016
  • In this study, design and performance of infiltration trench using woodchip as media for treating stormwater from highway were examined through field monitoring. Average reduction efficiency for TSS, COD, BOD, TN, and TP was 88%, 94%, 85%, 80%, and 75% respectively, which is similar to values reported by other studies and design manuals even though direct comparison is not possible due to different monitoring and design conditions. Mean field infiltration rate estimated by measuring the change of water depth inside the observation well was about 40mm/hr, and the time taken for complete infiltration was about 0.83days, which corresponds well with design criteria recommended by MOE guidelines in Korea. In addition, according to analysis of infiltration rate and reduction efficiency, effective rainfall depth applied for determining water quality volume(WQv), 5mm was found to be properly established as design criteria. Woodchip must be considered and included as an alternative media together with crushed rock and gravel into the design guidelines because it has more advantages in terms of weight, porosity, cost, and easiness of management than other media materials.

Edge-Enhanced Error Diffusion Halftoning using Local mean and Spatial Activity (국부 평균과 공간 활성도를 이용한 에지 강조 오차확산법)

  • Kwak Nae-Joung;Kwon Dong-Jin;Kim Young-Gil;Ahn Jae-Hyeong
    • The KIPS Transactions:PartB
    • /
    • v.13B no.2 s.105
    • /
    • pp.77-82
    • /
    • 2006
  • Digital halftoning is the technique to obtain a bilevel-toned image from continuous-toned image. Among halftoning methods, the error diffusion method gives better subjective quality than other halftoning ones. But it also makes edges of objects blurred. To overcome the defect, we proposes the modified error diffusion to enhance the edges using the property that human vision perceives the local average luminance and doesn't perceive a little variation of the spatial variation. The proposed method computes a spatialactivity, which is the difference between a pixel luminance and the average of its $3{\times}3$ neighborhood pixels' Iuminance weighted according to the spatial positioning. The system also usesof edge enhancement (IEE), which is computed from the normalized spatial activitymultiplied by the average luminance. The IEE is added to the quantizer's input pixel and feeds into the halftoning quantizer. The quantizer produces the halftone image having the enhanced edge. The computer experimental results show that the proposed method produces clearer bilevel-toned images than conventional methodsand the edge of objects is preserved well. Also the performance of the preposed method is improved, compared with that of the conventional method by measuring the edge correlation and the local average accordance at some ranges of viewing distance.

LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA (국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상)

  • Shin Woo-Jin;Jeon Young-Sik;Lee Keun-Woo;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

Insomnia in Patients with Chronic Renal Failure on Hemodialysis (혈액투석 중인 만성 신부전증 환자에서의 불면증에 대한 연구)

  • Kim, Gyung-Ryul;Yang, Chang-Kook;Hahn, Hong-Moo
    • Sleep Medicine and Psychophysiology
    • /
    • v.6 no.2
    • /
    • pp.126-132
    • /
    • 1999
  • Objectives: The purposes of this study were to investigate 1) the incidence of insomnia, 2) the clinical characteristics of the insomniacs, 3) the correlation of severity of insomnia with somatic complaints and psychological distresses, and 4) the beliefs and attitudes about sleep in patients with chronic renal failure on hemodialysis. Methods: The author evaluated 153 patients, receiving hemodialysis therapy at the four outpatients hemodialysis units in Pusan, Korea. The patients had completed a self-administered questionnaire package, which consisted of basic demographic findings, questions characterizing insomnia, Beck Depression Inventory(BDI), Spielburger's State-Trait Anxiety Inventory(STAI), and visual analogue scales measuring quantitatively the severity of the self-perceived psychological and somatic symptoms. And several laboratory data were collected. Diagnosis of insomnia was made in the base of insomnia criteria of DSM-IV and international classification of sleep disorders. Subjects were dichotomized into those who reported any characteristics of insomnia or those who had no insomnia during the preceding two weeks. Results: Insomnia was found in 100(65.4%) of 153 patients. No statistical differences were found between the patients with and without insomnia in terms of age, gender, education, marital status, mean duration of hemodialysis and all considered laboratory findings except serum albumin. The patients with insomnia had significantly higher BDI score and predialysis systolic blood pressure, and lower serum albumin as compared to non-insomnia group. Significant differences were found between two groups in terms of self-perceived distress such as sadness, anxiety, worry, pruritus, and dysfunction of daily life. The data showed statistically significant correlation between insomnia severity and some variables such as physical dysfunction, pruritus, bone pain, sadness, anxiety, worry, dysfunction of daily life and excessive daytime sleepiness. The patients with insomnia had significantly several dysfunctional beliefs and attitudes about sleep than those without insomnia. Conclusion: These results indicate that insomnia is very common in hemodialysis patients and likely contribute to the impaired quality of life experienced by many these patients. The author suggests that physical and psychological distresses would be reduced and the quality of life could be improved if their sleep disturbances are properly ameliorated in patients on hemodialysis.

  • PDF

Usefulness Evaluation of Artifacts by Bone Cement of Percutaneous Vertebroplasty Performed Patients and CT Correction Method in Spine SPECT/CT Examinations (척추 뼈 SPECT/CT검사에서 경피적 척추성형술 시행 환자의 골 시멘트로 인한 인공물과 CT보정방법의 유용성 평가)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.49-61
    • /
    • 2014
  • Purpose: With the aging of the population, the attack rate of osteoporotic vertebral compression fracture is in the increasing trend, and percutaneous vertebroplasty (PVP) is the most commonly performed standardized treatment. Although there is a research report of the excellence of usefulness of the SPECT/CT examination in terns of the exact diagnosis before and after the procedure, the bone cement material used in the procedure influences the image quality by forming an artifact in the CT image. Therefore, the objective of the research lies on evaluating the effect the bone cement gives to a SPECT/CT image. Materials and Methods: The images were acquired by inserting a model cement to each cylinder, after setting the background (3.6 kBq/mL), hot cylinder (29.6 kBq/mL) and cold cylinder (water) to the NEMA-1994 phantom. It was reconstructed with Astonish (Iterative: 4 Subset: 16), and non attenuation correction (NAC), attenuation correction (AC+SC-) and attenuation and scatter correction (AC+SC+) were used for the CT correction method. The mean count by each correction method and the count change ratio by the existence of the cement material were compared and the contrast recovery coefficient (CRC) was obtained. Additionally, the bone/soft tissue ratio (B/S ratio) was obtained after measuring the mean count of the 4 places including the soft tissue(spine erector muscle) after dividing the vertebral body into fracture region, normal region and cement by selecting the 20 patients those have performed PVP from the 107 patients diagnosed of compression fracture. Results: The mean count by the existence of a cement material showed the rate of increase of 12.4%, 6.5%, 1.5% at the hot cylinder of the phantom by NAC, AC+SC- and AC+SC+ when cement existed, 75.2%, 85.4%, 102.9% at the cold cylinder, 13.6%, 18.2%, 9.1% at the background, 33.1%, 41.4%, 63.5% at the fracture region of the clinical image, 53.1%, 61.6%, 67.7% at the normal region and 10.0%, 4.7%, 3.6% at the soft tissue. Meanwhile, a relative count reduction could be verified at the cement adjacent part at the inside of the cylinder, and the phantom image on the lesion and the count increase ratio of the clinical image showed a contrary phase. CRC implying the contrast ratio and B/S ratio was improved in the order of NAC, AC+SC-, AC+SC+, and was constant without a big change in the cold cylinder of the phantom. AC+SC- for the quantitative count, and AC+SC+ for the contrast ratio was analyzed to be the highest. Conclusion: It is considered to be useful in a clinical diagnosis if the application of AC+SC+ that improves the contrast ratio is combined, as it increases the noise count of the soft tissue and the scatter region as well along with the effect of the bone cement in contrast to the fact that the use of AC+SC- in the spine SPECT/CT examination of a PVP performed patient drastically increases the image count and enables a high density of image of the lesion(fracture).

  • PDF