• Title/Summary/Keyword: measurement of permeability

Search Result 256, Processing Time 0.03 seconds

Development of the Simplified Measurement Device for Permeability of the Levee and the Determination of Its Applicability (하천제방 간이투수조사장비의 개발과 적용성 평가에 관한 연구)

  • Kim, Jin-Man;Jin, Young-Ji;Choi, Bong-Hyuck;Lee, Dae-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.2
    • /
    • pp.15-21
    • /
    • 2012
  • It is difficult to determine the strength and the permeability of a soil levee quantitatively because the damages of a levee have been evaluated only by visual inspection in Korea. Therefore, it is necessary to develop a simplified measurement device for measuring the strength and permeability of a levee. In this paper, a new in-situ permeability measuring device which can measure strength and permeability based on GWP is developed and its applicability to the field permeability test of a soil levee is introduced. From the laboratory and in-situ experiments, the new measuring device has the potential of measuring the soil permeability simply and accurately.

Nondestructive Evaluation for Remanent Life of 1Cr-0.5Mo Steel by Reversible Permeability

  • Ryu, Kwon-Sang;Lee, Yun-Hee;Park, Jong-Seo;Baek, Un-Bong
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.206-209
    • /
    • 2012
  • Peak interval for reversible permeability is presented for nondestructively evaluating the remanent life of 1Cr-0.5Mo steel. The method to measure the peak interval of reversible permeability is based on the value of reversible permeability is the same as the differential value of the hysteresis loop. The measurement principle is based on the first harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to a frequency of the exciting voltage. Results obtained for the peak interval of reversible permeability and Rockwell hardness on the aged samples decrease as aging time and the Larson-Miller parameter increase. We could estimate the remanent life of 1Cr-0.5Mo steel by using the relationship between the peak interval of reversible permeability and the Larson-Miller parameter, nondestructively.

Development of Resonant-Type Magnetometer Using High Permeability Isotropic Magnetic Material (고투자율 등방성 자기 물질을 이용한 공진형 마그네토미터 개발)

  • Yim, Jeong-Bin;Shim, Yeong-Ho;Ahn, Yeong-Sub
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.29-37
    • /
    • 2005
  • The design and development if Resonant-type Magnetometer(RM) using isotropic magnetic with high permeability is described in this paper. At first, the relationship between the inductance L if the coil winding on a magnetic material and the permeability u(H) appearing in the magnetic material with isotropic and high permeability is defined as a background theory. Then the circuit if RM, which is to obtain the values if L as the change qf frequency is implemented using simple Schmitt Trigger Circuit Through the swinging tests, which is to evaluate the measurement ability if RM, the measurement possibility for the component of earth field was confined.

  • PDF

Measurement of Longitudinal Liquid Permeability Using Pressure Bomb Method (Pressure Bomb법을 이용한 섬유방향 액체투과성 측정)

  • Hur, Jong-Yun;Kang, Ho-Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.66-74
    • /
    • 1997
  • Liquid permeabilities of red oak and several softwoods were measured by the pressure bomb method and a modified liquid permeability method in order to investigate their efficacy. The effect of preboiling and prefreezing on wood permeability were also examined for both green and resaturated specimens. Regardless of some disadvantages these two methods were revealed as a handy tool for quick evaluation of the permeability of an unknown species. The permeabilities of the resaturated specimens increased when preboiled. but decreased when prefrozen. For green specimens, however, pre freezing increased permeability. The discrepancy of the pre freezing effect on two specimens partially attributes to their difference of initial permeabilities. For all species except radiata pine heartwood, the radii of the effective capillary pores, derived from the water potential equation, distribute from $0.42{\mu}m$ to $7.2{\mu}m$. Those of radiata pine heartwood are below $0.46{\mu}m$.

  • PDF

Measurement of Water Vapor Permeability of Bio-polymer Films (생고분자 필름의 투습도 측정)

  • Rhim, Jong-Whan
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.5 no.1
    • /
    • pp.37-46
    • /
    • 1999
  • Water vapor permeability of films is commonly calculated from the water vapor transmission rate of the film measured using a permeability cup method which is essentially a gravimetric method. This method was originally developed for petroleum based plastic films with low water vapor permeability. In the case of hydrophilic bio-polymer films, the resistance caused by a stagnant air layer, which is developed between the underside of the film mounted on the cup and the surface of the desiccant saturated salt solution or distilled water, can be significant and, if neglected, ran lead to underestimation of water vapor transmission rates. Therefore, it is necessary to correct water vapor transmission rate data to accurately estimate the water vapor permeability of bio-polymer films.

  • PDF

Transverse permeability measurement of a circular braided preform in liquid composite molding

  • Chae, Hee-Sook;Song, Young-Seok;Youn, Jae-Ryoun
    • Korea-Australia Rheology Journal
    • /
    • v.19 no.1
    • /
    • pp.17-25
    • /
    • 2007
  • In liquid composite molding (LCM), composites are produced by impregnation of a dry preform with liquid resin. The resin flow through the preform is usually described by Darcy's law and the permeability tensor must be obtained for filling analysis. While the resin flow in the thickness direction can be neglected for thin parts, the resin flow in the transverse direction is important for thicker parts. However, the transverse permeability of the preform has not been investigated frequently. In this study, the transverse permeability was measured experimentally for five different fiber preforms. In order to verify the experimental results, the measured transverse permeability was compared with numerical results. Five different fiber mats were used in this study: glass fiber woven fabric, aramid fiber woven fabric, glass fiber random mat, glass fiber braided preform, and glass/aramid hybrid braided preform. The anisotropic braided preforms were manufactured by using a three dimensional braiding machine. The pressure was measured at the inlet and outlet positions with pressure transducers.

Magnetic Permeability Measurement of Stainless Steels in Vacuum Chamber Fabrication (스테인리스강 진공용기 제작 공정중 투자율 변화 측정)

  • Hong, M.S.;Park, C.D.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.6
    • /
    • pp.460-466
    • /
    • 2010
  • We measured the magnetic properties of stainless steels type 304 and 316L to see if those materials can be used for the applications where non-magnetic materials are required. The results show that the relative permeability of samples was greatly increased during manufacturing processes. After full solution annealing, however the permeability could be reduced to less than 1.02. Thus, the materials may be employed in the low-permeability applications.

Evaluation of Oxygen Permeability of Soft Contact Lenses Based on Thickness (두께 기준에 따른 소프트 콘택트렌즈의 산소투과성 평가)

  • Yu, Dong-Sik;Moon, Byeong-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.2157-2163
    • /
    • 2009
  • The oxygen permeability of a soft contact lens is an important parameter for determining corneal health when considering the physiological response of the eye. The aim of this study is to evaluate the oxygen permeability of soft contact lenses based on thickness, using the polarographic method. The thickness of lens was measured using contact and non-contact method. To assess accuracy and reliability, the Bland-Altman plot was used. The reliability was high for the oxygen permeability based on center thickness measured by contact method, whereas the accuracy was high for the oxygen permeability based on center thickness measured by non-contact method. These results indicate that the permeability characteristics were variable according to the measurement and criteria of thickness of soft contact lenses and the measurement of soft contact lenses by non-contact method was more reasonable. Thus, contact lens practitioners should consider some basic differences between methodologies when interpreting or quoting oxygen performance data.

Measurement of In-plane Gas Permeability of Gas Diffusion Layers in Proton Exchange Membrane Fuel Cells under Compressive Strain (고분자 전해질 연료전지 가스확산층의 압축상태 평면 기체투과율 측정)

  • Oh, Changjun;Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.367-372
    • /
    • 2016
  • Gas diffusion layer (GDL) of PEMFCs plays a role that it diffuses the reactant gases to the catalyst layer on the membrane and discharge water from the catalyst layer to the channel. Physical parameters related to the mass transport of GDL are mostly from the uncompressed GDLs while actual GDLs in the assembled stacks are compressed. In this study, the relation of compression and strain of GDLs with various Polytetrafluoroethylene (PTFE) loading is measured experimentally and In-plane gas permeability is measured at the condition that the GDLs are in compressive strain. The gas permeability decreased with the loading of PTFE and the presentation of gas permeability under compressive stain is expected to improve the accuracy of modeling work of mass transport in the GDL.

Measurement of ileal permeability with different-sized polyethylene glycols (PEG 400, 600 and 1000)

  • Kim, Mee-Hye
    • Archives of Pharmacal Research
    • /
    • v.19 no.2
    • /
    • pp.100-105
    • /
    • 1996
  • Polyethylene glycols (PEGs; 400, 600, and 1000) were used to study the molecular weight (MW) permeability dependence in the rat ileal mucosa. Absorption of the PEGs was measured by following their recirculation perfusion over a 3 hr collection period. HPLC methods were used to separate and quantitate the individual oligomers present in the solution of PEGs mixtures (MW range 330 to 1 1 22 D). In the range studied, a distinct molecular weight cutoff was not identified. Corrected for the length of ileum used in the study, over the molecular weight range 330 to 1122 D, the apparent permeability $(P_{app)$ of PEG ranged from $3.2\pm0.06\times10_{-5} cm/sec(mean\pmSEM, n=7)\; to\; 0.1\pm0.02\times10^{-5} cm/sec.$ Also, it was observed that the apparent permeability was inversely proportional to approximately $MW^{2.4}$.

  • PDF