• 제목/요약/키워드: measurement of environmental radioactivity

검색결과 34건 처리시간 0.02초

Development of a real-time mobile gamma-ray measurement system for shipboard use

  • Chang-Jong Kim;Mee Jang;Hyuncheol Kim;Jong-Myoung Lim;Wanno Lee;Gyu-Seong Cho
    • Nuclear Engineering and Technology
    • /
    • 제55권11호
    • /
    • pp.4077-4082
    • /
    • 2023
  • Large areas must be rapidly screened to monitor radiation in marine environments. For this purpose, this study developed a mobile real-time gamma-ray measurement system for shipboard use and evaluated its performance. The system was developed to measure engine or generator cooling water by installing a canister inside the ship. The minimum detectable activity of the system is about 0.8 Bq/L for a 60 s measurement period, and real-time data transmission and remote control are possible. The system was tested in the field and is currently being installed and operated on ships in service. Such a ship-based real-time gamma-radiation measurement system is suitable for a wide range of marine radiation surveillance applications and is expected to be rapidly deployed.

실내 환경 모니터링을 위한 다중 방사능계측 시스템 설계 (Multi-Radioactivity Measurement System Design for Indoor Environmental Monitoring)

  • 사공병일;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 춘계학술대회
    • /
    • pp.459-461
    • /
    • 2022
  • 본 논문에서는 실내 환경에서 검출되는 방사능을 측정하기 위한 계측 시스템을 제시한다. 일반 가정, 작업장, 연구소 등 다양한 공간에서 발생되는 방사능을 측정하고 이에 대한 예방을 위함이다. 다중 방사능 센서를 이용해서 여러 공간을 동시에 측정한다. 측정된 방사능 데이터는 지그비를 통해서 실시간으로 PC로 전달하여 모니터링하는 시스템이다. 소량의 방사능이라고 하더라고 만성 피폭으로부터의 예방을 위해 연구소 또는 작업장 같은 방사능 노출이 예상되는 곳은 필수적으로 설치되어야 한다고 생각된다.

  • PDF

원자력 시설 주변 환경 감시를 위한 토양 중 우라늄 동위원소 신속 분석법 확립 (Establishing of a rapid analytical method on uranium isotopic ratios for the environmental monitoring around nuclear facilities)

  • 박지영;임종명;이현우;이완로
    • 분석과학
    • /
    • 제31권3호
    • /
    • pp.134-142
    • /
    • 2018
  • The uranium isotopic ratio in environmental samples around nuclear facilities is important because it reveals information regarding illegal activities or anthropogenic pollution. Determination of uranium isotopes, however, is a challenging task requiring much labor and time because of the complex separation procedures and lengthy process. In this study, a rapid determination method for uranium isotopes in environmental samples was developed using. The sample was completely decomposed using the alkali fusion method. The separation procedure using extraction chromatography (UTEVA) was simplified in a single step without any further removal process for Si and major matrix elements. The established method can be completed within 3 h from sample dissolution to ICP-MS measurement. Most matrix elements and uranium isotopes in the soil samples were well separated and purified. Five types of were used to assess the method's accuracy and precision for a rapid uranium analysis method. The analytical accuracy for all CRM samples ranged from 95.1 % to 97.8 %, and the relative standard deviation was below 3.9 %. From the analytical results, one may draw conclusions that the evaluated method for uranium isotopes using alkali-fusion, the extraction chromatography process, and ICP-MS measurements is fast and fairly reliable owing to its recovering efficiencies. Thus, it is expected that the evaluated method can contribute to the improvement of environmental monitoring ability.

Environmental Radioactivity Prior to the Kori Nuclear Power Plant Operation

  • Pak, Chan-Kirl;Yang, Kyung-Rin
    • Nuclear Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.13-25
    • /
    • 1978
  • 1970년 12월에서 1976년 12월 사이의 6년간 고리 원자력발전소 주변 환경에서 채취한 시료에 대하여 환경방사능을 측정조사하였다. 1976년에 채취한 공기미진에서 진알파 방사능과 1970년 12월에서 1976년 12월 사이에 채취한 시료인 토양, 물, 공기미진, 낙진, 솔잎, 빗물과 여런 식품시료에 페하여 전베타 방사능을 측정하였다. 시금치, 배추, 보리, 쌀, 뱀장어, 조기, 미역, 파해 및 우유 중에 함유된 스트론튬-90및 세시움-137 방사능은 방사화학적으로 분석하여 측정하였고 정수, 하천수, 바닷물 중의 트리튬도 전해법으로 농축하여 그 방사능을 측정하였다.

  • PDF

환경시료의 방사능 분석에서 Monte Carlo 방법을 이용한 자체흡수 효과 보정 (Corrections of Self-Absorption Effect Using the Monte Carlo Method in the Radioactivity Analysis of Environmental Samples)

  • 서범경;이대원;이길용;윤윤일;양태건
    • Journal of Radiation Protection and Research
    • /
    • 제26권2호
    • /
    • pp.51-58
    • /
    • 2001
  • 환경방사능과 같은 저준위 방사능 측정에서는 원통형과 Marinelli형 측정용기가 가장 일반적으로 사용된다. 효율교정용 표준선원과 측정시료의 높이 또는 매질의 밀도가 다르면 자체흡수 효과의 차이로 인한 보정이 필요하다. 본 연구에서는 Monte Carlo 방법을 이용하여 HPGe 검출기의 전에너지 피크 효율을 계산하여 측정치와 비교하였다. 원통형 용기에 대해서는 높이에 대한 효율변화 정도를 계산하였고, 원통형 및 Marinelli 측정용기에 대해서는 밀도변화에 따른 효율을 계산하였다. 밀도에 따른 효율의 감소 정도는 1000keV 이하의 에너지 영역에 대해 자체흡수 효과의 보정치 필요하다는 것을 알았다. 또한 계산의 타당성을 검증하기 위하여 NIST SRM 4353 표준물질을 이용하여 계산값과 인증값을 상호비교한 결과 오차범위 이내로 잘 맞는 다는 것을 확인하였다.

  • PDF

Estimation of natural radionuclide and exhalation rates of environmental radioactive pollutants from the soil of northern India

  • Devi, Vandana;Chauhan, Rishi Pal
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1289-1296
    • /
    • 2020
  • The estimation of radioactivity level is vital for population health risk assessment and geological point of view and can be evaluated as rate of exhalation and source concentration (226Ra, 232Th and 40K). The present study deals with the soil samples for investigation of radionuclides content and exhalation rates of radon -thoron gas from different sites in northern Haryana, India. Absorbed dose and associated index estimated in the present study are the measures of environmental radioactivity to inhalation dose. Effective doses received by different tissues and organs by considering different occupancy and conditions are also measured. Exhalation rates of radon and thoron are measured with active scintillation monitors based on alpha spectroscopy namely scintillation radon (SRM) and thoron (STM) monitors respectively. Sample height was optimized before measurement of thoron exhalation rate using STM. Average values of radon and thoron exhalation are found 16.6 ± 0.7 mBqkg-1h-1 and 132.1 ± 2.6 mBqm-2s-1 respectively. Also, a simple approach was also adopted, to evaluate the thoron exhalation which accomplished a lot of challenges, the results are compared with the data obtained experimentally. The study is useful in the nationwide mapping of radon and thoron exhalation rates for understanding the environmental radioactivity status.

원전주변 환경방사능 분석기술의 개선(I) (An Improvement on the Analysis Techniques of Environmental Radioactivity Around Nuclear Power Plants)

  • 김숭평;채경선;정운관
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.8-15
    • /
    • 1995
  • 환경방사능 분석기술은 원자력시설의 가동중 정상 및 비정상 상태시 이상판단과 지역특성에 따른 주변환경 방사능의 특성 및 거동파악 등을 하는데 필요한 기술로 원전 가동전, 후 환경방사능량을 비교함으로서 방사능 오염 및 변화상황을 파악할 수 있다. 국내에는 현재 관련법에 따라 규제기관 및 관련기관에 의해 환경감시가 계속되어오고 있으나 분석기술에 대한 한국규격이 없으므로 분석절차가 서로 상이하고 분석결과의 상대오차율이 커서 환경방사선 감시결과에 대한 신뢰성이 떨어지고 있다. 따라서 토양시료에 대한 감마핵종 분석에 한정하여 기수행된 측정방법 및 결과 둥을 비교분석하므로서 원전주변 환경방사능 감시목적에 적합한 분석기술의 신뢰도 향상 및 상대오차율 최소화 방안을 도출하였다

  • PDF

Environmental Radioactivity at Ko-ri Nuclear Power Plant Site December 1970-November 1972

  • Yang, Kyung-Rin;Pak, Chan-Kirl
    • Nuclear Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.240-248
    • /
    • 1973
  • 고리에 위치한 원자력발전소 건설부지의 환경방사능의 측정보고이며 1970년 12월부터 1972년 11월 사이에 일광, 월내, 신암, 좌천, 소상 고리등 여섯개 지역에서 채취한 토양, 물, 솔잎, 낙진시료에 대하여 전방사능을 측정하였고 1972년에 채집한 채소류, 해산물 시료에 대하여 Sr-90 Cs-137의 방사능을 측정하였다. 각 시료의 측정처를 보면 그값은 계절적인 변화와 연차적인 감소천상을 나타내 주고 있다.

  • PDF

환경 방사능 처리기술에서의 Compton suppression 및 Unsuppression system을 이용한 토양시료의 MDA 측정 (Measurement of MDA of Soil Samples Using Unsuppression System and Compton Suppression of Environmental Radioactivity in Processing Technology)

  • 강수만;임인철;이재승;장은성;이미현;권경태;김창태
    • 한국방사선학회논문지
    • /
    • 제8권6호
    • /
    • pp.293-299
    • /
    • 2014
  • Compton suppression 장치는 Compton 산란 반응을 이용하여, 스펙트럼의 Compton continuum 부분을 억제함으로써 Compton continuum 영역 내에서의 감마선 피크들의 분석을 보다 명확하게 할 수 있게 해주는 장치이다. 표층토양 시료에서 검출된 인공 방사능인 $^{137}Cs$과 자연 방사능인 $^{40}K$핵종의 방사능 농도 값들에 대한 방사능 계수치가 백그라운드를 상회하는 측정값이 발생되거나, 불필요한 방해피크나 비해석 대상 피크에 대하여 검출된 표준선원의 방사능 농도 값들의 실측치에 대한 background를 비억제 스펙트럼(Compton Unsuppression)과 억제 스펙트럼(Compton suppression)을 적용시켜 측정 에너지에 대한 교정을 알고자 점선원인 $^{137}Cs$을 거리별에 따라 측정하여, 몬테칼로 시뮬레이션과 비교 분석함으로서 효율적인 검출 능력을 얻고자 함이며, Compton 억제 인자를 보면 거리가 멀어짐에 따라 CSF 값이 클수록 더 많은 Compton suppression가 이루어졌음을 알 수 있고, $^{137}Cs$을 이용한 컴프턴 비억제 모드와 억제모드로 측정된 스펙트럼에서 컴프턴 연속에 의한 백그라운드가 감소함을 알 수 있었다.

먹는 샘물의 방사성물질 측정 및 유해성 평가 (Evaluation of Radioactive Substance and Measurement of Harmfulness in Drinking Water)

  • 조정원;이상복;남조현;노은정;백현우;이예진;이준세;최지원;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.247-252
    • /
    • 2021
  • As the number of single-person households increases, the consumption of bottled water is increasing. In addition, as the public's interest in radioactivity increases, interest in the field of living radioactivity is also increasing. Since drinking water is an essential element in our daily life, it must be safe from radioactivity. In this study, gamma radiation of drinking spring water was measured and internal exposure dose evaluation was performed to determine its harmfulness. K-40 and uranium-based radioactivity analysis was performed through a high-purity germanium detector, and as a result, drinking water was detected somewhat higher than that of mixing water. Since there is no regulation on the natural radioactivity concentration in Korea, it was compared with the U.S. Environmental Protection Agency Drinking Water Regulations and World Health Organization standard. As a result, there were some items that exceeded standards. Internal exposure was evaluated according to the effective dose formula of ICRP 119. As the result was derived that a maximum of 1.17 mSv per year could be received. This result means that the dose limit for the general public may be exceeded, and it was judged that it is necessary to set an appropriate standard value and present a recommendation value through continuous monitoring in the future.