• 제목/요약/키워드: measurement of Pressure

검색결과 3,219건 처리시간 0.04초

송풍기의 소음레벨 측정방법 (KS B6361, 2000년 개정내용을 중심으로) (Methods of A-weighted Sound Pressure Level Measurement for Fans and Blowers (KS B 6361, Focus on Revised Content made in 2000))

  • 김경호;이승배
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.424-432
    • /
    • 2000
  • The revision was provided for the method of A-weighted sound pressure measurement for fans and blowers, in which the newly developed measurement techniques were applied to KS B 6361. This revision includes the sound power methods for radiated sound from the body, the in-duct measurement method, and the correction method for flow noise upon measuring microphone, etc.

  • PDF

Intra and Inter-Rater Measurement Reliability of Tibialis Anterior Muscle (TA) Thickness using the Ultrasonography Spring Gauge Technique

  • Hwang, Byeong-Hun;Jang, Tae-Jin;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제33권4호
    • /
    • pp.187-192
    • /
    • 2021
  • Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.

3D패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구 (Improvement of ECG Measurement for the Elderly's U-healthcare Clothing Using 3D Tight-fit Pattern)

  • 박해준;신승철;손부현;홍경희
    • 한국의류산업학회지
    • /
    • 제10권5호
    • /
    • pp.676-682
    • /
    • 2008
  • In this study a guideline of the 3D-fit pattern for the ECG(electrocardiogram) measurement of elderly's u-healthcare clothes was proposed. In the screening test of the ECG measurement band, ECG peak band was observable at the band pressure of 0.20 kPa. By employing a 3D body image, tight-fit 3D patterns were made at two different reduction rates of 21%(pattern 1) and 33%(pattern 2), and corresponding pressure of both of the clothes were 0.25 kPa and 0.54 kPa, respectively. Typical waves of ECG were found in both stationary and moving position. In terms of the subjective evaluation of the u-healthcare clothes when worn, it was confirmed that reduction pattern 1(0.25 kPa) conveyed comfortable clothing pressure and pleasantness, which is very close to the result of screening test of ECG band experiment. As results, it is recommended that reduction rate should be adjusted, so that clothing pressure is about 0.2 kPa for the elderly's comfortable and efficient u-healthcare clothes.

무구속적 맥파 전달 시간의 측정을 통한 혈압 추정 (Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure)

  • 지영준;박광석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

무선 압력센서를 이용한 실시간 맥박수 측정기 개발 (Development of Real-time Heart Rate Measurement Device Using Wireless Pressure Sensor)

  • 최상동;조성환;정연호
    • 한국전기전자재료학회논문지
    • /
    • 제29권5호
    • /
    • pp.284-288
    • /
    • 2016
  • Among the various physiological information that could be obtained from human body, heartbeat rate is a commonly used vital sign in the clinical milieu. Photoplethysography (PPG) sensor is incorporated into many wearable healthcare devices because of its advantages such as simplicity of hardware structure and low-cost. However, healthcare device employing PPG sensor has been issued in susceptibility of light and motion artifact. In this paper, to develop the real-time heart rate measurement device that is less sensitive to the external noises, we have fabricated an ultra-small wireless LC resonant pressure sensor by MEMS process. After performance evaluation in linearity and repeatability of the MEMS pressure sensor, heartbeat waveform and rate on radial artery were obtained by using resonant frequency-pressure conversion method. The measured data using the proposed heartbeat rate measurement system was validated by comparing it with the data of an commercialized heart rate measurement device. Result of the proposed device was agreed well to that of the commercialized device. The obtained real time heartbeat wave and rate were displayed on personal mobile system by bluetooth communication.

Measurement and analysis of body pressure distribution on a bed

  • 박세진;황민철;김창범
    • 대한인간공학회:학술대회논문집
    • /
    • 대한인간공학회 1995년도 춘계학술대회논문집
    • /
    • pp.55-61
    • /
    • 1995
  • We spend about 40% of lifte time on a bed and seek how such amount of time is spent comfort. Bed comfort has been pursuited. The pressure distributions on a bed by body pressure has been considered as one of the most important factors of bed comfort. This study is to quantify the subjective assessment by the body pressure distribution and develop the objective evaluation method of bed comfort. A new measurement system for body pressure on a bed was developed in this study. The thin film pressure sensor (FSR: Force Sensing Resistor) of an elastomer-type was used to prevent the distortion of contact pressure. The pressure distribution is measured by FSR and displayed on the monitor by color-coded contour patterns. Some of the bed test results were described. And the relations between body pressure distribution and bed comfort were evaluated.

  • PDF

캐비티가 발생한 프로펠러의 변동압력 추정을 위한 실험적 연구 (An experimental study for prediction of the fluctuating pressure induced by a cavitating propeller)

  • 김기섭;문일성;김경열;송인행;이진태
    • 대한조선학회논문집
    • /
    • 제36권1호
    • /
    • pp.47-52
    • /
    • 1999
  • 캐비테이션 터널에서 캐비티가 발생한 프로펠러에 의하여 평판에 작용하는 변동압력이 계측정도를 향상시키고, 프로펠러 회전수 영향을 최소화 하였다. Sydney Express선의 프로펠러 변동압력에 대한 타기관의 계측치 특성과 비교한 결과 당 연구소 계측치는 매우 안정적 경향을 보였다. 그리고 모형선과 실선의 변동압력 계측치 및 평판에 작용하는 변동압력 계측치의 크기와 경향을 비교한다. 평판의 변동압력 계측치로부터 실선 변동압력을 추정코자 양력면 이론에 의한 수치계산에 의해 도출된 강체경계율을 적용하여 타당성을 확인하였다.

  • PDF

성인의 긴장성 두통에 에어견인요법이 앞쪽머리자세와 ROM 및 통증에 미치는 영향 (The Effects of Air-Pressure Cervical Traction Treatment on Forward Head Posture, ROM and Pain in the Tension Headache in the Adults)

  • 조남정;이솔재
    • 대한통합의학회지
    • /
    • 제2권4호
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose : The purpose of this study was to ascertain the effects of air-pressure cervical traction on the tension headache in the adults. Method : All subjects were treated with air-pressure cervical traction while 15 minutes a day, 3 times per week, for 4 weeks. The effects of air-pressure cervical traction were evaluated by HIT-6(headache impact test), VAS, and flexion, extension, left right flexion, left right rotation of cervical ROM. The measured data were analyzed by using repeated ANOVA. Especially in order to investigate the effect of air-pressure cervical traction. The comparison with among three measurement time. Results : The results of this study were as follows; 1) Prior and two weeks measurement did not show significant differences. The head forward posture than before the experiment, each experimental group was significantly increased(p<.05). 2) Prior and two weeks measurement did not show significant differences. The experimental group than ever cervical ROM of the movable range increased significantly(p<.05). 3) The experimental group was significantly lower than before the VAS(p<.05). 4) HIT score of the experimental group was significantly lower than before(p<.05). Conclusion : These findings suggest that air-pressure cervical traction had effect on the tension headache in the adults.

표준중량충격원을 이용한 건축물의 바닥 충격음 차단성능 측정불확도 평가 (Evaluation of uncertainty in measurement of floor impact sound insulation of buildings using standard heavy impact source)

  • 이용봉;권혁제;김창환;조만희;김항;정성수
    • 한국음향학회지
    • /
    • 제42권2호
    • /
    • pp.143-151
    • /
    • 2023
  • 본 논문은 표준 중량충격원을 이용한 건축물의 바닥충격음 차단성능을 측정하는 경우 측정불확도를 평가하는 방법을 다루었다. 반복 측정의 영향 이외에도 측정 위치의 영향, 가진 위치의 영향, 음압측정에 사용된 장비의 영향 및 충격원의 영향 등을 고려하였다. 평균 최대 바닥충격음 레벨 측정의 수학적 모델을 제시하고 요인별 불확도 평가방법을 제안하였으며, 제안한 방법을 실제 측정 결과에 적용하여 평균 최대 바닥충격음 레벨 및 측정불확도를 평가하였다.

과도상태의 압력데이터로부터 평형상태 압력 예측방법 연구 (A Study on the Method of Equilibrium-Pressure Prediction from Transient Data)

  • 이종국
    • 한국항공우주학회지
    • /
    • 제32권7호
    • /
    • pp.19-28
    • /
    • 2004
  • 본 논문은 과도상태의 압력데이터로부터 평형상태의 압력을 예측하는 방법을 제시하고 있다. 압력을 측정하는 곳과 압력센서는 튜브로 연결되어져 있다. 측정하고자하는 압력 (측정압력)이 높은 경우에는 압력센서가 빠른 시간 내에 측정압력에 반응을 한다. 그러나 매우 낮은 압력을 측정하는 경우에는 압력센서가 실시간으로 측정압력에 반응을 하지 못하여 압력지연현상이 발생하게 된다. 이러한 압력지연현상을 파악하고자 여러 가지 실험이 수행되었다. 본 연구의 제시된 평형압력예측방법은 낮은 압력을 측정함에 있어서 측정시간을 단축시킬 수 있다.