• 제목/요약/키워드: measurement index

검색결과 2,172건 처리시간 0.036초

SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류 (Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index)

  • 이승기
    • 센서학회지
    • /
    • 제13권5호
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.

DEVELOPMENT OF A SOUND QUALITY INDEX FOR THE EVALUATION OF BOOMING NOISE OF A PASSENGER CAR BASED ON REGRESSIVE CORRELATION

  • LEE J. K.;PARK Y. W.;CHAI J. B.;JANG H. K.
    • International Journal of Automotive Technology
    • /
    • 제6권4호
    • /
    • pp.367-374
    • /
    • 2005
  • This paper proposes a sound quality index to evaluate the vehicle interior noise. The index was developed using a correlation analysis of an objective measurement and a subjective evaluation data. First, the objective set of measurements was obtained at two specified driving conditions. One is from a wide-open test condition and the other is from a constant-speed test condition. At the same time, subjective evaluation was carried out using a score of ten scale where 17 test engineers participated in the experiment. The correlation analysis between the psycho-acoustic parameters derived from the objective measurement and the subjective evaluation was performed. The most critical factors at both test conditions were determined, and the corresponding equations for the sound quality were obtained from the multiple factor regression method. Finally, a comparative work between previous index and present index was performed to validate the effectiveness of the proposed index.

A Novel Color Breakup Measurement Technique for Field Sequential Display

  • Lai, Yueh-Yi;Liao, Wen-Hung;Mo, Chi-Neng
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1069-1072
    • /
    • 2009
  • Field sequential display has some advantages but color breakup (CBU) is the significant problem. Many researches had introduced several methods to reduce CBU phenomenon, however there are no reliable methods to measure the degree of CBU. In this report, a novel CBU measurement technique which was based on the image processing method and subjective analysis results had proposed to evaluate the degree of CBU. Color Breakup Index (CBI) was presented to be a useful index to recognize the CBU phenomenon in the different field sequential technique displays.

  • PDF

부패지수와 LISREL 측정모형의 적용 -행정 신뢰성의 계량적 측정- (Corruption Index and Application of LISREL Measurement Model)

  • 최종후;안민영
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제2권1호
    • /
    • pp.33-45
    • /
    • 2002
  • We investigate into some problems related to Corruption Perception Index(CPI). Delphi method is a popular for obtaining CPI; it is a mean of systematically collecting and progressively refining information provided by a group of selected experts in order to obtaining the weight values of questionnaires. However, Delphi method hold low aspect, to some extent, for it is solely dependent upon the judgment of a few professionals. In this paper, we propose the measurement model for X in LISREL as alternative for gaining the weight values of questionnaires. We use the 1999 Seoul ACI(Anti- Corruption Index) for empirical study.

  • PDF

클러스터 측정과 유전자 알고리즘을 이용한 문서 클러스터링 (Document Clustering using Generic Algorithm and Cluster Measurement)

  • 최임천;박순철
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2010년도 추계학술발표대회
    • /
    • pp.490-493
    • /
    • 2010
  • 본 논문에서는 클러스터 측정(Cluster Measurement)과 유전자 알고리즘을 이용한 문서 클러스링 알고리즘을 제안한다. 유전자 알고리즘의 요소를 클러스터링에 대입하고 클러스터 측정을 적합도 함수에 대입하여 문서 클러스터링을 구현하였다. 성능 평가를 위하여 한국일보-20000/한국일보-40075 문서범주화 실험문서집합의 데이터 셋을 이용하였다. 클러스터링 성능 평가 결과 AS Index가 DB Index, RS Index 보다 좋은 성능을 보여준다. 또한 제안한 알고리즘이 K-means 클러스터링 알고리즘에 비교해 안정적으로 좋은 성능을 보여준다.

경두개 도플러 초음파의 측정지표와 성/연령의 상관성 (Correlation of Gender/Age and Measurement Indices of Transcranial Doppler Ultrasonography)

  • 진복희
    • 대한임상검사과학회지
    • /
    • 제42권3호
    • /
    • pp.155-160
    • /
    • 2010
  • Transcranial Doppler ultrasonography (TCD) allows measurement of blood flow velocity to be made from the basal intracerebral vessels. Blood flow velocity in TCD is highly affected not only by blood vessel diameter, blood flow volume, blood viscosity, but also age and sex. Therefore, the study is focused on the correlation between TCD measurement index and sex/age. Subjects were 214 (male 147, famale 67) who had TCD for headache and stroke evaluations at Dongguk University Ilsan Hospital neurology department from December 2009 to April 2010. Sex did not show significant differences with mean flow velocity (MFV), peak systolic flow velocity (PSFV), end diastolic flow velocity (EDFV), pulsatility index (PI) and resistance index (RI) in middle cerebral artery (MCA). Although age also did not show significant differences with MFV and PSFV, EDFV has statistically decreased with age, and PI and RI has statistically increased with age. In addition, age showed significant correlation with MFV, EDFV, PI and RI, but not with PSFV. Therefore, TCD is definitely correlated with age and sex, so that those influencial factors must be considered when being tested.

  • PDF

국가과학기술전자도서관 고객만족지수 측정에 관한 연구 (An Analysis on Measurement of Customer Satisfaction Index of NDSL)

  • 황재영;이응봉;최호남
    • 한국도서관정보학회지
    • /
    • 제37권4호
    • /
    • pp.247-270
    • /
    • 2006
  • 본 연구의 목적은 국가과학기술전자도서관(NDSL)의 고객만족지수를 측정하는데 있다. NDSL 정보시스템에 맞는 이용자만족지수 모형을 제안하고 개발된 모형의 검증을 위해 구조방정식모형 분석도구인 LISREL을 통해 인과적 경로분석을 실시하였다. 또한 차원별로 서로 다른 이용자 만족지수 산출 방법을 수립하고 수립된 산출 방법에 따라 다양한 이용자만족지수를 측정하고 분석하였다.

  • PDF

Expected RGDOP Based Satellite Selection Scheme for Performance Improvement of Precise Float Solution

  • Lee, Sunyong;Lim, Deok Won;Noh, Jae Hee;Lee, Jin Hyuk;Lee, Sang Jeong
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제7권4호
    • /
    • pp.255-265
    • /
    • 2018
  • In this paper, the positioning performance index is proposed. The proposed index is used to find satellites that degrade positioning performance to improve the positioning performance. To do this, the proposed index is calculated using the code measurement quality and the DOP. And, through the experiment, the effectiveness of the proposed index is confirmed. In the experiment, the quality of the code measurements is analyzed, and the effectiveness of the proposed index is confirmed by comparing with the result of the precise float solution. Finally, it is shown that the precise float solution performance is improved by using the proposed index.

Assessing the Refractive Index of Glass Beads for Use in Road-marking Applications via Retroreflectance Measurement

  • Shin, Sang Yeol;Lee, Ji In;Chung, Woon Jin;Cho, Sung-Hoon;Choi, Yong Gyu
    • Current Optics and Photonics
    • /
    • 제3권5호
    • /
    • pp.415-422
    • /
    • 2019
  • Retroreflection of vehicle headlights, as induced by spherical glass beads, is a key optical phenomenon that provides road-surface markings with greatly enhanced visibility, thus better securing a driver's safety in the nighttime as well as in unclear daytime. Retroreflectance of glass beads is a quite sensitive function of their refractive index, so that measurement of the refractive index of glass specifically in the shape of spherical beads needs to be performed within a reasonable uncertainty that is tolerable for road-marking applications. The Becke line method has been applied in assessing refractive index of such glass beads as e.g. an industrial standard in the Republic of Korea; however, the reference refractive-index liquids are not commercially available these days for refractive index greater than 1.80 due to the toxicity of the constituent materials. As such, high-refractive-index glass beads require an alternate method, and in this regard we propose a practically serviceable technique with uncertainty tantamount to that of the Becke line method: Based on comparison of calculated and measured retroreflectance values of commercial glass beads, we discover that their refractive index can be determined with reasonable precision via the retroreflectance measurement. Specifically, in this study the normalized retroreflectance originating from a single glass sphere is computed as a function of refractive index using the Fresnel equations, which is then validated as coinciding well with retroreflectance values measured from actual specimens, i.e. glass-bead aggregates. The uncertainties involved are delineated in connection with radius and imperfections of the glass beads.

로봇 캘리브레이션을 위한 모델 파라미터의 관측성 연구 (A Study on Observability of Model Parameters for Robot Calibration)

  • 범진환;양수상;임생기
    • 한국정밀공학회지
    • /
    • 제14권4호
    • /
    • pp.64-71
    • /
    • 1997
  • Objective of calibration is to find out the accurate kinematic relationships between robot joint angles and the position of the end-effector by estimating accurate model parameters defining the kinematic function. Estimating the model parameters requires measurement of the end-effector position at a number of different robot configurations. This paper studies the implication of measurement configurations in robot calibration. For selecting appropriate measurement configurations in robot calibration, an index is defined to measure the observability of the model parameters with respect to a set of robot configurations. It is found that, as the observability index of the selected measurement configurations increase the attribution of the position errors to the parameter errors becomes dominant while the effects of the measurement and unmodeled errors are less significant; consequently better estimation of parameter errors is expected. To demonstrate the implication of the observability measure in robot calibration, computer simulations are performed and their results are discussed.

  • PDF