• 제목/요약/키워드: measurement and record system

검색결과 78건 처리시간 0.023초

균형성과표를 활용한 전자의무기록시스템의 성과측정 모형개발 (Development of the Performance Measurement Model of Electronic Medical Record System - Focused on Balanced Score Card -)

  • 이경희;김영훈;부유경
    • 한국병원경영학회지
    • /
    • 제21권4호
    • /
    • pp.1-12
    • /
    • 2016
  • The purpose of this study are suggest to performance measurement model of Electronic Medical Record(EMR) and Key Performance Index(KPI). For data collection, 665 questionnaires were distributed to medical record administrators and insurance reviewers at 31 hospitals, and 580 questionnaires were collected(collection rate: 87.2%). Regarding methodology, Critical Success Factor(CSF) and index of the information system were derived based on previous studies, and these were set as performance measurement factors of EMR system. The performance measurement factors were constructed by perspective using BSC, and analysis on causal relationship between factors was conducted. A model of causal relationship was established, and performance measurement model of EMR system was proposed through model validation. Analysis on causal relationship between performance management factors revealed that utility cognition of the learning & growth perspective factor had causal relationship with job efficiency(${\beta}=0.20$) and decision support(${\beta}=0.66$) of the internal process perspective factors, and security had causal relationship with system satisfaction(${\beta}=0.31$) of the customer perspective factor. System quality had causal relationship with job efficiency(${\beta}=0.66$) and decision support(${\beta}=0.76$) of the internal process perspective factors, all of which were statistically significant(P<0.01). Job efficiency of the internal process perspective had causal relationship with system satisfaction(${\beta}=0.43$), and decision support had causal relationship with decision support satisfaction(${\beta}=0.91$) and job satisfaction (${\beta}=0.74$), all of which were statistically significant(P<0.01). System satisfaction of the customer perspective had causal relationship with job satisfaction(${\beta}=0.12$), job satisfaction had causal relationship with cost reduction(${\beta}=0.53$) of the financial perspective, and decision support satisfaction had causal relationship with productivity improvement(${\beta}=0.40$)of the financial perspective(P<0.01). Also, cost reduction of the financial perspective had causal relationship with productivity improvement(${\beta}=0.37$), all which were statistically significant(P<0.05). Suitability index verification of the performance measurement model whose causal relationship was found to be statistically significant revealed that $X^2/df=2.875$, RMR=0.036, GFI=0.831, AGFI=0.810, CFI=0.887, NFI=0.838, IFI=0.888, RMSEA=0.057, PNFI=0.781, and PCFI=0.827, all of which were in suitable levels. In conclusion, the performance measurement indices of EMR system include utility cognition, security, and system quality of the learning & growth perspective, decision support and job efficiency of the internal process perspective, system satisfaction, decision support satisfaction, and job satisfaction of the customer perspective, and productivity improvement and cost reduction of the financial perspective. In this study, it is expected that the performance measurement indices and model of EMR system which are suggested by the author, will be a measurement tool available for system performance measurement of EMR system in medical institutions.

전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발 (The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status)

  • 전정채;오훈
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4855-4862
    • /
    • 2015
  • 본 논문에서는 전력설비의 동작 상태를 주기적으로 감시 및 기록함으로써 전기안전사고를 예방하고 사후 원인 분석을 지원하기 위한 저가형 전력 성분 측정 및 기록 시스템을 제안한다. 제안된 시스템에서는 정밀한 전력 성분의 측정과 기록, 원격 측정이 가능하면서도 비용을 줄일 수 있도록 부품을 선정하여 제작하였다. 특히, IEEE 1459-2010에 정의된 전력 성분을 계산하기 위해 MAXIM사의 78M6631을 이용함으로써 저비용 고성능 시스템 구현이 가능하였다. 개발된 시스템은 공인 시험기관에서 사용하고 있는 YOKOGAWA 전력분석기 WT1600 과 같은 표준 장비를 이용하여 측정 성능 시험을 실시하였다. 그 결과 측정 오차가 0.5%이하로 나타났고 6개월 이상 현장에 설치하여 동작 신뢰성과 원격 측정 성능 시험을 실시하여 그 성능을 입증하였다.

함정의 수중폭발 충격시험을 위한 계측장비 시스템 개발 (Development of Measurement System for the Underwater Explosion Shock Test of Naval Ships)

  • 박일권;조대승;김종철
    • 대한조선학회논문집
    • /
    • 제40권4호
    • /
    • pp.66-74
    • /
    • 2003
  • In non-contact underwater explosion shock test of a real naval ship, measurement of shock loadings and responses should require onboard system to be able to safely trigger an explosive and to simultaneously and successfully measure scores of shock signals in the deteriorated environment. For this purpose, we have developed a shock-hardened measurement system resistible to 170g peak acceleration having 4 msec duration by resiliently mounting general purpose measurement instruments in racks. The system can simultaneously measure and record 200 signals to evaluate shock leadings and responses of the test ship by triggering an explosive and measurement instruments at the same time. We prove the performance of the developed system by introducing the signal acquisition results from of a real ship underwater shock test, firstly performed in Korea.

위치(位置) 측정장치(測定裝置)를 이용한 트랙터의 자동(自動) 주행장치(走行裝置) (Automatic Guidance System for Tractor based upon Position-measurement Systems)

  • 최창현
    • Journal of Biosystems Engineering
    • /
    • 제15권2호
    • /
    • pp.79-87
    • /
    • 1990
  • An automatic guidance system based upon two position-measurement systems was designed to record where the tractor traveled and to guide the tractor along the predetermined path. An algorithm, using the kinematic behavior of tractor movement, was developed to determine the steering angle to reduce lateral position error. The algorithm was based upon constant travel speed, constant steering rate, and zero slip angles of the tractor wheels. The algorithm was evaluated through use of computer simulation and verified in field experiments. Results showed that the distance interval between position measurements was an important factor in guidance system performance. The position-measurement error of the guidance system must be less than 5 cm to be acceptably precise for field operations. An algorithm based upon a variable steering rate might improve the stability of the guidance system. More accurate measurement of tractor position and yaw angle, and faster error processing are required to improve the field performance of the guidance system.

  • PDF

조선시대(朝鮮時代) 중기(中期)의 포백척(布帛尺)에 관한 연구(硏究) - 조선왕조실록(朝鮮王朝實錄)을 중심으로 - (A Study on Pobeckchuck in the Middle period of Chosun Dynasty(Second) - Focusing on the History of Chosun Dynasty)

  • 이은경
    • 한국생활과학회지
    • /
    • 제16권3호
    • /
    • pp.623-630
    • /
    • 2007
  • The remarkable fact regarding the History of Chosun Dynasty(from Jungjong- Youngjo) is that any slightest evidence can't be found that Pobeckchuck was used to measure clothes or various Pobecks. There remains the document that in the 22nd years of Myeonjong, Japan required that Pobeckchuck be used, but it couldn't be allowed because of the reason it was made in the former king. This fact raises the high possibility that Pobeckchuck could be the most trustworthy standardized ruler at that time, and in other point of view, it can be presumed that the measurement in the period of King Sejong continued to have been used until this time. It can be seen that the length of one Chuck of Pobeckchuck at this time must have been equivalent to 46. 73cm of Pobeckchuck of Samchuck in the period of Sejong. In the History of Sunjo Period, many records on Pobeckchuck can be found, which fact seemed to have rectified the measurement system which was disordered by military revolt, though the reason is not clear. Also a record can be found that in the period of Sunjo, Chinese envoy required the Sunjo Regime to use Pobeckchuck for the measurement of copper pillar, which record supports the fact that Pobeckchuck is the standardized ruler. Another record that in the 26th period of Youngjo, Pobeckchuck of Samchuck was corrected according to the Kyeongkukdaejeon shows that the length of Pobeckchuck was 46.80cm at that time. Also, the record which rectified many rulers with the comparison of Hwangjong-chuck, Ju-chuck, Joryeki-chuck, Yongjo-chuck, etc. with one another reveals that the rulers used in the period of Sejong continued to have been used unchanged until in the period of Youngjo.

하중 가변형 전동 프레스를 이용한 차량용 클러치 디스크 쿠션 변위량 측정 장치 개발 (Development of Vehicle Clutch Discs Cushion Variation Measurement Device Using a Variable Load Electric Press)

  • 박승규;최해운
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.64-69
    • /
    • 2016
  • Vehicle clutch measurement for disc cushion variation was developed for the production of high quality Dual clutch transmissions. The developed device is composed of load cells for load measurement and LVDT for measuring the distance variation measurement in cushion variation. The servo motor-driven electric press for flexible loads that was developed was controlled by a PC-based HMI system, LabVIEW, and the device was able to continuously record real time measurement data with the accuracies of ${\pm}0.1\;kgf$ load and ${\pm}5{\mu}m$ cushion amount, which is far above the requirements of commercial vehicle standards.

영상 및 NFC 기반 실시간 시약 계량 등록 시스템 (Image and NFC based Real Time Reagent Measurement and Registration System)

  • 이근우;정상호;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권6호
    • /
    • pp.652-658
    • /
    • 2019
  • 사물인터넷을 이화학, 약학, 생물학 및 의학 등 다양한 연구실험분야에 적용한 경우 다양한 센서와 기기를 부착하여 지능적으로 연구장비 및 환경을 모니터링하고 제어함으로써 연구실험자의 안전성과 편의성을 증대시킬 수 있다. 시약의 정확하고 편리한 기록관리 및 실험과정의 연구이력과 근거, 역추적성 등을 위해서는 실시간 시약 계량 및 등록의 연구지원 자동화 서비스를 제공해야 한다. 현재 기존 시약관리방법은 전산 관리방법을 이용하지만 시약등록과 관리가 일체화된 자동화가 많이 이루어져 있지 않다. 또한 수기에 의한 기록 관리가 대부분으로 실험에 대한 기록오류 및 많은 시약에 대한 계량 및 등록에 대한 소요시간이 큰 점 등 번거로움과 문제점들이 많다. 이에 본 논문에서는 영상인식 및 NFC(Near Field Communication) 방식에 의한 시약 등록과 동시에 전자저울로 계량 측정된 시약정보를 자동으로 관리할 수 있는 IoT 기반 실시간 시약 계량 및 등록 방법을 연구하였다.

Visibility Measurement in an Atmospheric Environment Simulation Chamber

  • Tai, Hongda;Zhuang, Zibo;Jiang, Lihui;Sun, Dongsong
    • Current Optics and Photonics
    • /
    • 제1권3호
    • /
    • pp.186-195
    • /
    • 2017
  • Obtaining accurate visibility measurements is a common atmospheric optical problem, and of vital significance to civil aviation. To effectively evaluate and improve the accuracy of visibility measurements, an outdoor atmospheric simulation chamber with dimensions of $1.8{\times}1.6{\times}55.7m^3$ was constructed. The simulation chamber could provide a relatively homogeneous haze environment, in which the visibility varied from 10 km to 0.2 km over 5 hours. A baseline-changing visibility measurement system was constructed in the chamber. A mobile platform (receiver) was moved from 5 m to 45 m, stopping every 5 m, to measure and record the transmittance. The total least-squares method was used to fit the extinction coefficient. During the experiment conducted in the chamber, the unit weight variance was as low as $1.33{\times}10^{-4}$ under high-visibility conditions, and the coefficient of determination ($R^2$) was as high as 0.99 under low-visibility conditions, indicating high stability and accuracy of the system used to measure the extinction coefficients and strong consistency between repeated measurements. A Grimm portable aerosol spectrometer (PAS) was used to record the aerosol distribution, and then Mie theory was used to calculate the extinction coefficients. The theoretical results were found to be consistent with the measurements and exhibited a positive correlation, although they were higher than the measured values.

High-$T_c$ SQUID 자력계를 이용한 자기잡음 환경에서의 미세자기신호 측정 및 분석 (Measurement of weak magnetic signals using high-$T_c$ SQUID magnetometers in magnetically disturbed environment)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.121-126
    • /
    • 2003
  • The single layer direct-coupled YBCO SQUID magnetometers have been fabricated and characterized for the purpose of the measurement of weak magnetic signals in unshielded environment. Two types of magnetometers have been designed and fabricated using 10 mm$\times$ 10 mm substrates. We could operate the conventional 3-mm-wide solid pickup loop magnetometers more stably than the 12-parallel-line pickup loop magnetometers in laboratory environment. We developed a first-order electronic gradiometer system using the SQUID sensors with axial displacement of 80 mm without any mechanical alignment of magnetometers. The system with a software filter using calculation of discrete Fourier transform could record clearly weak pulse signal of 100 pT in a magnetically disturbed environment.

  • PDF

경영시스템 도입 중소기업의 품질이행율 향상을 위한 품질기록 관리운영의 표준화 사례연구 (Introduction of Management System Case Study on Standardization of Quality Record Management to Improve Quality Performance Rate of SMEs)

  • 조철희;박병화;박진이
    • 품질경영학회지
    • /
    • 제47권4호
    • /
    • pp.911-926
    • /
    • 2019
  • Purpose: In an infinite market competition, companies are adopting management systems to gain a competitive advantage. The expectancy effect of the management system is management performance improvement and accurate measurements. These can be made through quality records with integrity and maintainability. This paper examines the operation of records management standards, which are records, storage and management standards for quality records to understand the needs of records management standards and empathize with their needs. Methods: This paper examines PEC's (Pields Engineering Co., Ltd.) specific processes and standards for integrating individual management systems and establishing records management standards. We also look at the specific features of the Search Tool and Document Storage Management Standards that support records management standards. Results: The integration process of PEC's individual management system consists of five steps. A PDCA-based process was established to erode the confusion and inefficiencies caused by overlap between individual management systems. Also, by accurately grasping corporate competence, PEC established a record management standard suitable for the characteristics of the company. PEC's records management standards are used as a useful standard for organizing quality records, and have an impact on management performance improvement. Conclusion: PEC's records management standards enable the verification of quality performance rates and performance measures. Companies can implement appropriate quality improvement strategies based on the numbers identified by introducing records management standards. Companies can succeed in improving management performance when operating quality management that combines performance measurement techniques and records management standards.