• 제목/요약/키워드: measurement

검색결과 47,191건 처리시간 0.057초

기구인영비교맥법에 대한 수지맥진과 기기측정치의 상관성 연구 (Study of the relationship between manual pulse diagnosis and machinery measurement on QiguㆍInyoung comparison pulse diagnosis)

  • 전용석;채우석;조명래;소철호;최찬헌;장경선
    • 동의생리병리학회지
    • /
    • 제16권1호
    • /
    • pp.201-208
    • /
    • 2002
  • The measurement parameter of QiguㆍInyoung pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Qigu and Inyoung. We have estimated the relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis by means of quantifying pulse peak and Inyoung/Qigu index. The results can be summarized as follows : When standardizing manual pulse diagnosis measurement was standardized, Inyoung index of machinery measurement was more significantly correlative with the index of manual pulse diagnosis than Qigu index of machinery measurement. The ratio of Inyoung/Qigu magnitude with machinery measurement was doser to manual pulse diagnosis than that of Qigu and Inyoung pulse magnitude measured separately. A linear proportion relationship was found between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis. It was necessary to adjust the output signal of pulse in order to estimate the exact relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis.

Effects of Fan-Aspirated Radiation Shield for Temperature Measurement in Greenhouse Environment

  • Yang, Seung-Hwan;Lee, Chun-Gu;Kim, Joon-Yong;Lee, Won-Kyu;Ashtinai-Araghi, A.;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • 제37권4호
    • /
    • pp.245-251
    • /
    • 2012
  • Purpose: Provision of accurate temperature measurement is an essential element to ensure a precise control in greenhouse environment. This study was organized to compare the effects of six solar radiation shields with different shapes for temperature measurement and find the most appropriate shield for greenhouse environment. Methods: A fan-aspirated radiation shield was designed and manufactured. Using the fan-aspirated radiation shield and five other shapes i.e., the cup shape, horizontal pipe, vertical pipe, parallel boards and commercial shields, temperature measurement was conducted over the lawn surface as well as greenhouse indoor environment. The measurement height varied at 0.5, 1.0 and 1.5 m from the floor. Results: The measured temperatures by the fan-aspirated radiation shield were 1.30-$1.49^{\circ}C$ lower than the values recorded by other different-shaped shields at 1.5 m of measurement height. As the measurement height decreases, observed differences between measured temperatures of the fan-aspirated radiation shield and other shields demonstrate a declining trend. However, at low measurement heights, the radiation emitted from the bottom surface would be the source of error in temperature measurement. Conclusions: The fan-aspirated radiation shield is a required tool for exact measurement of air temperature in greenhouse temperature control.

근접 전계 시험 시설을 이용한 능동 위상 배열 안테나 송신 빔 패턴 측정 (Transmit-Beam Pattern Measurement of the Active Phased-Array Antenna Using Near-Field Measurement Facility)

  • 채희덕;김한생;이동국;정명득;박종국
    • 한국전자파학회논문지
    • /
    • 제22권12호
    • /
    • pp.1155-1164
    • /
    • 2011
  • 본 논문에서는 국내 최초로 개발되는 함상용 중거리 레이더에 사용되는 능동 위상 배열 안테나의 송신 빔 특성을 근접 전계 시험으로 측정하는 방안에 대하여 제시하였다. 측정하고자 하는 능동 위상 배열 안테나는 고출력 송신 빔을 펄스 형태로 방사하기 때문에 저출력의 연속적인 파형을 사용하는 일반적인 근접 전계 시험 시설에서는 측정하기 어렵다. 그래서 본 논문에서는 고출력 송신 시에도 견딜 수 있도록 설계된 근접 전계 시험 시설과 펄스 모드 측정을 지원하는 Agilent사의 PNA-X 네트웍 분석기를 이용한 근접 전계 시험으로 펄스 형태의 고출력 송신 빔을 방사하는 능동 위상 배열 안테나를 측정하는 방안에 대하여 제시하였고, 실제 개발된 능동 위상 배열 안테나의 고출력 송신 빔 패턴을 근접 전계 시험으로 측정하였다. 또한, 능동 위상 배열 안테나의 송신 특성인 EIRP(Effective Isotropic Radiated Power)를 측정하였고, 수학적인 계산을 통해 예측한 EIRP 값과 비교한 결과 0.1 dB의 오차 내에서 동일함을 확인하였다.

Performance Evaluation of Web-based Cloud Services in a Browser-Scripting Approach

  • Zhang, Chengwei;Hei, Xiaojun;Cheng, Wenqing
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권6호
    • /
    • pp.2463-2482
    • /
    • 2016
  • Cloud services are often provisioned to their customers using user-friendly web browsers with flexible and rich plug-in environments. Delay is one of the fundamental performance metrics of these web-based services. Commonly-used network measurement tools usually only measure network delay and it may be difficult to infer the web-delay performance using only network layer measurement approaches. In this paper, we propose to evaluate the application layer delay in a browser-based network measurement platform using engineered scripts. We conducted a delay measurement study using instrumented scripts in the proposed browser-based measurement platform. Our investigation included a comparison study of three browser-scripting delay measurement methods, including Java applet, JSP and Flash ActionScript. We developed a browser-based delay measurement testbed over the Internet so that different delay measurement tools could be evaluated in the same real network environment including typical Internet paths and the Baidu cloud. We also decomposed the components of the end-to-end delay process of the above measurements to reveal the difference and relationship between the network-layer delay and the application-layer delay. Our measurement results characterize the stochastic properties of the application-layer delay over real Internet paths, and how these properties vary from the underlying network layer delay. This browser-scripting measurement approach can be easily deployed on different cloud service platforms to inspect their application-layer delay performance between end clients and the cloud platforms. Our measurement results may provide insights into designing new cloud services with enhanced quality-of-experience perceived by cloud users.

복부 움직임에 따른 초음파 근접센서를 이용한 호흡측정에 관한 연구 (Abdominal Wall Motion-Based Respiration Rate Measurement using An Ultrasonic Proximity Sensor)

  • 민세동;김진권;신항식;윤용현;이충근;이정환;이명호
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2071-2078
    • /
    • 2009
  • In this paper, we proposed a non-contact respiration measurement system with ultrasonic proximity sensor. Ultrasonic proximity sensor approach of respiration measurement which respiration signatures and rates can be derived in real-time for long-term monitoring is presented. 240 kHz ultrasonic sensor has been applied for the proposed measurement system. The time of flight of sound wave between the transmitted signal and received signal have been used for a respiration measurement from abdominal area. Respiration rates measured with the ultrasonic proximity sensor were compared with those measured with standard techniques on 5 human subjects. Accurate measurement of respiration rate is shown from the 50 cm measurement distance. The data from the method comparison study is used to confirm the performance of the proposed measurement system. The current version of respiratory rate detection system using ultrasonic can successfully measure respiration rate. The proposed measurement method could be used for monitoring unconscious persons from a relatively close range, avoiding the need to apply electrodes or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using ultrasonic sensor offers a promising possibility of non-contact measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range of the measurement and quality of the rate-finding for broadening the potential application areas of this technology.

고령 여성의 측면체형 분류에 따른 직접측정치와 3차원 자동측정치간의 차이 분석 (Analysis of Difference between Direct Measurement and 3-D Automatic Measurement According to Classification of Side Figure of Elderly Women)

  • 정주원;남윤자;박진희
    • 한국의류산업학회지
    • /
    • 제21권5호
    • /
    • pp.627-639
    • /
    • 2019
  • This study analyzes differences between the results of 3D direct measurements and automated measurements for Korean elderly females according to age groups, side somatotype, and BMI groups. This study compares the measurement differences of the direct and the 3D automated measurements for women between the ages of 70 to 85, according to age group, BMI group, and side somatotype. A comparison of the results of the direct measurement and the 3D automated measurements for elderly women show that a meaningful discrepancy exists for 29 items out of 33 items. Furthermore, the results of comparing the average error tolerance recommended by ISO20685 shows that 30 items out of 33 items exceeded ISO recommendations. The results of the automated measurement program shows a higher degree of accuracy for straight postures; however, this unsuitable for postures of elderly women with a changed somatotype. The analysis results of the measurement difference indicate the suitability of the automatic measurement programs is found to be high for stood postures, while problems seem to exist on several items along with an automated program is not appropriately used due to posture and part of body changes for elderly women. Therefore, it is recommended to develop an algorithm, that reflects the body changes of elderly women first and then upgrade the automated program equipped with a measurement size method. It is hoped that the study results can be utilized as base data for improving the automated measurement program.

방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발 (Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device)

  • 진동식;김경령;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

레이저센서를 이용한 비접촉식 두께자동측정기 개발 (Development of Automated Non-contact Thickness Measurement Machine using a Laser Sensor)

  • 조경철;김수연;신기열
    • 한국기계가공학회지
    • /
    • 제14권2호
    • /
    • pp.51-58
    • /
    • 2015
  • In this study, we developed an automated non-contact thickness measurement machine that continuously and precisely measures the thickness and warp of a PCB product using a laser sensor. The system contains a measurement part to measure the thickness in real time automatically according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The measurement machine was utilized to evaluate the performance at each step to minimize measurement error. At the zero setting for the initial setup, the standard deviation of the 216 samples was determined to be $5.52{\mu}m$. A measurement error of 0.5mm and 1.0mm as a standard sample in the measurement accuracy assessment was found to be 2.48% and 2.28%, respectively. In the factory acceptance test, the standard deviation of 1.461mm PCB was measured as $28.99{\mu}m$, with a $C_{pk}$ of 1.2. The automatic thickness measurement machine developed in this study can contribute to productivity and quality improvement in the mass production process.

가속도 센서를 이용한 이동거리 측정 시스템 연구 (A Study on the Moving Distance Measurement System using a Accelerometer Sensor)

  • 박승훈;김성우;임재환;류지열
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.283-285
    • /
    • 2012
  • 본 연구에서는 정확한 운동량 측정을 위하여 가속도 센서, MCU, 그리고 블루투스를 이용하여 운동량 측정 시스템을 모듈화하여 실시간 무선으로 이동거리 정보를 알아내는 간편한 운동량 측정 시스템을 제작하여 모의실험 및 분석하였다. 그 결과를 기성품과 신뢰성 및 정확도를 비교해 보았다. 결과를 토대로 소형 및 운동화 실장이 가능한 운동량 측정시스템을 제작하고자 하였다.

  • PDF

Isomorphism, Human Resource Capability and Its Role in Performance Measurement and Accountability

  • WULANINGRUM, Puspita Dewi;AKBAR, Rusdi;SARI, Martdian Ratna
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권12호
    • /
    • pp.1099-1110
    • /
    • 2020
  • This research tests the effects of institutional pressures, the use of performance measurement systems and accountability, and moderation effects of human resource capability between institutional pressures and the use of performance measurement systems in the Local Government institutions in Indonesia. The research aims to provide empirical evidence both quantitatively and qualitatively that isomorphism institutional pressures occurred in the scope of implementation of the performance measurement system and accountability in the public sector organizations and to show the importance of human resource capability enhancement in reducing external pressure impact. In addition, it tries to develop the correlation model of institutional pressures, human resource capability, implementation of the performance measurement system, and accountability of public sector organizations. The research used mixed methods with sequential explanatory design. The data collection used surveys and interviews in 209 regency/Special Region of Yogyakarta and Central Java local governments as samples. The research result indicated that the institutionalization process of the performance measurement is influenced by institutional pressures, especially coercive and mimetic pressures. Human resource capability was unable to weaken institutional pressures effects in the performance measurement system implementation. The research also proved that the use of a performance measurement system was able to improve local government institution accountability.