• Title/Summary/Keyword: measurement

Search Result 47,191, Processing Time 0.059 seconds

Concentration Measurement of Alcohol Solution Using Immersion-Type On-Line Refractometer (침적식 온라인 굴절계를 이용한 알코올 농도의 측정)

  • 정옥진;김영한
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.6
    • /
    • pp.473-477
    • /
    • 2003
  • An immersion-type on-line refractometer useful for the in-situ measurement of chemical composition and temperature is developed, and its performance is examined by applying the refractometer to known alcohol solution having concentrations between 0 vol. % and 25 vol. %. Because refractive index and temperature are measured simultaneously, it is possible to compensate the effect of temperature for fast and direct measurement. The outcome of composition measurement for the different concentrations of alcohol solution indicates that the device is suitable for the chemical composition measurement by yielding stable and reproducible reading.

A Study of Form Measurement using Noncontact Sensor (비접촉식 센서를 사용한 형상 측정 연구)

  • 송정섭;황윤호;배종일;이만형
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.407-410
    • /
    • 1995
  • Many researches on measurement technology has been made and developed by various methods. Considering the measurement environment with cutting fluid, coolant and the like, contact type measurement methods are mostly used. But contact measurement method has measuring force and so the sensing head becomes worn. By these reasons, we considered sensors not influenced by the former fluid and so can acquire accrate measured values using error compensation due to temperature and vibration. For this purpose, eddy current sensors and Extended kalman Filter Algorithm for processing measured data has been used. In this paper, we present new technology that can be used for measuring workpiece with previous bad environment using direct method and comparison measurement method. We used cylindrical workpieces which were produced by grinding machine for the target.

  • PDF

A Preliminary Study on the In-line Concentration Measurement of Absorbent Solution (흡수용액의 In-line 농도측정을 위한 기초연구)

  • 민병혁;황덕용;정시영;구기갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.152-158
    • /
    • 2003
  • Titration method is one of the widely used methods for the concentration measurement of absorbent ammonia/water. However, this method is inconvenient because the solution should be extracted for the measurement. Moreover, significant error can be introduced by the evaporation of ammonia during the sampling and measuring procedure. In this study a reliable in-line concentration measurement method was proposed. To prove the validity of the concept, a measuring apparatus was designed, built, and tested with water. It is found that the location of flow inlet and exit is important in the measurement accuracy. The flow inlet and exit located in the middle of the test cell showed the best result. By the error analysis, it is expected that the ammonia concentration can be measured within the error of $\pm$0.18% assuming the error of 0.1 K in temperature measurement and 0.1 g in weight measurement.

Two-Dimensional Assessment for Measurement System Analysis (측정시스템 분석을 위한 2차원 척도 평가)

  • Seo, Sun-Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.42 no.4
    • /
    • pp.607-616
    • /
    • 2014
  • Purpose: This paper reviews popular measurement system indices and proposes a procedure for assessing a measurement system using two parameters with intraclass correlation and a factor for process capability. Methods: Gage Repeatability and Reproducibility(GR&R), precision-to-tolerance ratio(PTR), number of distinct categories, producer's and consumer's risks are employed to assess the measurement capabilities and discuss the relationships between measurement system metrics. Results: Two-dimensional plot by two parameters is presented to assess adequacy of the measurement system and process capability. A numerical example and previously studied case study are provided for illustration. Conclusion: The procedure proposed in this paper using two-dimension parameters provides a valuable procedure and helpful guidelines to quality and production managers in assessing the capabilities of a measurement system and choosing the needed actions to be the most benefit.

Measurement error reduction technique for the Semiconductor Device DC Characteristic Measurement System (반도체 소자의 직류특성 측정 시스템에서의 저전류 측정 오차 감소 기법)

  • Choi, In-Kyu;Jung, Hae-Yone;Park, Jong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.352-355
    • /
    • 2001
  • In this paper, we proposed measurement error reduction technique for the semiconductor device DC characteristic measurement system. Implemented system is composed of 4 SMUs, 2 VSUs, and 2 VMUs. Various efforts in hardware and software have been made to reduce the measurement errors due to the leakage current in measurement circuits. Internal and external sources of errors in measurement system especially in pA range measurement have been identified and removed. Experimental results show that the implemented system can be measure the DC characteristic of semiconductor devices in pA level.

  • PDF

Analytics of PIV Measurement and Its Application for Higher Performances

  • NISHIO Shigeru;SUGII Yasuhiko
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.62-74
    • /
    • 2001
  • Present paper describes the principles of PIV measurement approaching from the analytical view, which enables to explain the general form of principles covering all the PIV measurement, and that gives theoretical basis for its higher measurement performances. The explanation of the measurement principles started from the definition of governing equation in differential form as same as the gradient method, and the integral along the particle path line was executed to show the principle of the correlation method with same basis. The integral processes clearly shows the analytical reason why the correlation peak gives the terminal point of path line, and how the effects of deformation and rotation of fluid appears in the correlation map. These results have no differences from our experiences and understandings of the conventional PIV measurement definition in final form. However, the analytical approach enable to understand those facts a priori, and it makes easy to achieve the innovative higher performances of measurement. Analytical explanation clearly shows the behavior of the residual errors caused by the fluid motion, and it enables to analyze the measurement uncertainty theoretically.

  • PDF

Improvement of the Accuracy and Conveniency in Automated Strain Measurement through High-Resolution Image Processing (고해상도 화상처리를 통한 자동 변형률 측정의 정확도와 편의성 개선)

  • Kim, H.J.;Choi, S.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2006.06a
    • /
    • pp.34-39
    • /
    • 2006
  • An automated surface-strain measurement system, named ASIAS, was developed by using the image processing and stereo vision techniques in the previous studies by the corresponding author and his coworkers. This system has been upgraded mainly to improve the accuracy through image enhancement, sub-pixel measurement, surface smoothing, etc., since the first version was released. The present study has still more improved the convenience of users as well as the accuracy of measurement by processing high resolution images 8 mega pixels or more which can be easily obtained from a portable digital steal camera. It is proved that high resolution image processing greatly decreases the measurement error and gives strain data without considerable deterioration of accuracy even when the deformed grids to be measured and the master grids for camera calibration are captured together in the same image, making the whole process of strain measurement much simpler.

  • PDF

The Improvement of Accuracy and Measurement Speed in the Low Current Measurement System (저전류 측정 시스템에서의 정밀도 및 측정 속도 향상)

  • Baek, Wang-Ki;Choi, In-Kyu;Park, Jong-Sik;Lee, Kyung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.550-553
    • /
    • 2002
  • A source meter is a basic instrument to perform a measurement of DC characteristic of semiconductor devices. the source meter can be used as variable voltage source, variable current source, voltage meter, or current meter. The accuracy of the low current measurement can be improved with the compensation of leakage current and charge and discharge current. In the low current measurement, the RC time constant is extremely big, so the measurement speed is very low. In this thesis, the analysis of the behavior of the measurement current according to the RC time constant and output capacitance and the method to accelerate the measurement speed.

  • PDF

The Study on the Surface Roughness Measurement by Using Scattered Lights (산란광을 이용한 표면 거칠기측정에 관한 연구)

  • 강효석;임한석;정해도;안중환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.464-468
    • /
    • 1996
  • To evaluate the surface integrity of machined products such as die, the surface roughness measurement is being much used. Especially, for machining automation and promotion of productivity, the surface roughness measurement technique changes from sepatate measuring system after machining process to the on-the-machine measurement. This study is on the surface roughness measurement by using scattered lights for on-the-machine measurement. This system is designed with a simple optical construction. And experiments are implemented with standard roughness specimen to obtain the parameters which are specularly reflected region parameter and diffusely reflected region parameter. To determine the surface roughness quickly, neural network is used. And this system gives the possibility to apply to the various production processes.

  • PDF

Error Evaluation on Flame Measurement in Combustion Field (연소장내 화염계측 오차 평가)

  • Yang, Young Joon;Heo, Tae Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.167-169
    • /
    • 2014
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, Phase Doppler Anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

  • PDF