• 제목/요약/키워드: measured displacement

검색결과 1,726건 처리시간 0.03초

튜브진동 시 지지부에서의 축.횡방향 미끄럼변위 분석 (Analysis of Axial and Transverse Slip Displacements during the Oscillation of a Supported Tube)

  • 송주선;김형규;이영호;김재훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.950-955
    • /
    • 2004
  • Slip displacement is brought into focus to study the tube fretting wear that occurs on the contact by the springs. An oscillating tube was in contact with plate support springs. The contact condition was varied as normal force 5 N, and gaps of 0.1 and 0.2 mm in the experiment. The oscillation range of the tube was also varied as 0.2, 0.3, 0.4 and 0.7 mm. Formulas for predicting the slip displacement range were derived in terms of the vibration amplitudes measured during the tube oscillation. It was found that the slip displacement in transverse direction was much higher ($720{\sim}33000$ times) than that in axial one. This resulted in the severer wear on the contact suffered from transverse slip.

  • PDF

p$^+$ Si 외팔보 구조를 이용한 광학 소자용 마이크로 구동기의 제작 (Fabrication of a Micro Actuator with p$^+$ Si Cantilevers for Optical Devices)

  • 박태규;양상식
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권5호
    • /
    • pp.249-252
    • /
    • 2001
  • The paper represents the design and fabrication of an electrostatic micro actuator with $p^+$,/TEX> Si cantilevers. The micro actuator consists of a plate suspended by four $p^+$,/TEX> silicon cantilevers and an electrode on a glass substrate. The $p^+$,/TEX> Si structure is fabricated by the boron diffusion process and the anisotropic wet etch process. The cantilevers of the micro actuator curl down because of the residual stress gradient in $p^+$,/TEX> silicon. When the electrostatic forec is applied to the $p^+$,/TEX> cantilevers, the vertical displacement of the plate can be achieved. The deflection of the cantilever due to the residual stress gradient and the vertical displacement by electrostatic force were calculated. The displacement of the plate was measured with a laser displacement meter for various input voltages and frequencies. The feasibility of the proposed micro actuator for the applications to optical pickup devices or optical communication devices was confirmed by the experiments.

  • PDF

ESPI법에 의한 강체 회전 변위 측정에 관한 연구 (A Study on the Rotating Displacement Measurement of Rigid Body by ESPI Method)

  • 김경석;홍명석
    • 한국자동차공학회논문집
    • /
    • 제1권2호
    • /
    • pp.125-133
    • /
    • 1993
  • Electronic Speckle Pattern Interferometry(ESPI) using a CW laser, a video system and image processor was applied to the rotating displacement of rigid body. ESPI require no special surface preparation or attachments and displacements between any two arbitrary points on the surface can be measured. The characteristic speckle pattern formed when imaging a scattering surface illuminated by laser light retains phase information, which can be used for interferometric measurement of surface displacement. The application of this principle to measuring in-plane displacement resolved in one direction is described, together with the novel use of television equipment to detect and process the information contained in the speckle pattern. This is faster, and more convenient and versatile than customary photographic methods.

  • PDF

Kuhn형 LB막 누적장치에서의 변위전류 측정 (Measurement of the displacement current using Kuhn-type LB film apparatus)

  • 송경호;박태곤;박근호;권영수;강도열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1200-1202
    • /
    • 1993
  • There are many methods to investigate the physical properties of monolayers formed at the air-water interface. Among them, the displacement current method is appropriate for the investigation of the dynamic behavior of monolayers. The measuring system of displacement current method was constructed at home-made Kuhn type LB deposition apparatus using aluminium plate electrode. The currents induced by the dynamic motion of molecules were measured when the molecules were pressed by barrier. To verify the measuring system, we used 4-octyl -4'-(5-carboxy-pentamethyleneoxy)-azobenzene molecules which has two remarkable variations of surface pressure of monolayer at the air-water interface. We can detect the two peaks of displacement currents which shows that the orientations of molecules are changed greatly at the state of these two remarkable changes of surface pressure.

  • PDF

철심형 전류변성기의 비오차 및 위상오차 절대 평가 기술의 확장 : 1차 전류 = $5\;kA{\sim}40\;kA$ (Extension of Absolute Evaluation Technique for Ratio Error and Phase Displacement of Core Type Current Transformers: Ip =$5\;kA{\sim}40\;kA$)

  • 김윤형;한상길;정재갑;한상옥
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.431-436
    • /
    • 2008
  • We have extended an absolute evaluation method to obtain the ratio error and phase displacement of a current transformer (CT) up to primary current of 40,000 A by measuring four parameters of equivalent circuit in CT. The method was applied to CTs under test with the current ratios in the range of 5,000 A / 5 A - 40,000 A / 5 A. The ratio error and phase displacement of the CTs under test obtained in this study are consistent with those measured at the national institutes in Canada and Germany using the same CTs under test within an expanded uncertainty (k = 2) in the overall current ratios.

실험적 변위측정위치에 따른 구속효과 A2의 거동 (Experimental Behaviors of Constraint Effect A2 depending on Opening Displacement Measurement near Crack Front for SS400.)

  • 한민수;장석기
    • 대한금속재료학회지
    • /
    • 제46권6호
    • /
    • pp.345-350
    • /
    • 2008
  • The magnitude of constraint effect $A_2$ value was experimentally estimated by using crack tip opening displacement(CTOD) between elastic and plastic regions near crack tip front for CT specimen with $25.4t{\ss}{\AE}$ SS400 steel. The constraint effect, $A_2$ was dependent on specimen configuration and on the measured positions of CTOD near crack front. $A_2$ should be estimated using the opening displacement calculated within crack front plastic region. If not, it's not reliable to evaluate of constraint effect at crack growth initiation in this paper.

철도교량에 거동발생 시 응력분포 분석에 따른 적정 방수재료 선정을 위한 평가 방법 (Waterproofing Material Evaluation Method based on Stress Dispersion Analysis due to Displacement in Railway Bridges)

  • 오규환;안기원;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 봄 학술논문 발표대회
    • /
    • pp.59-60
    • /
    • 2021
  • To measure the effect of the stress-strain dispersion across the installed waterproofing layer on the concrete surface, a strain gauge was attached to the gap between the waterproofing layer and the concrete structure at specified points of upper, center and bottom of the load-displacement simulation specimen, and the peak stress-strain at the displacement interface were measured and compared with stress-strain at other areas to analyze each material types' stress-strain dispersion ratio properties. Based on the results of the testing, it was shown that materials with high load-displacement resistance performance accordingly had high stress-strain dispersion ratio results, and the materials from highest performance to lowest performance were; CAS, SAS, PUC and CSC.

  • PDF

An experimental study on the cooling performance and the phase shift between piston and displacer in the Stirling cryocooler

  • Park, S. J.;Y. J. Hong;Kim, H. B.;D. Y. Koh;B. K. Yu;Lee, K. B.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.111-117
    • /
    • 2003
  • In the design of the split type free displacer Stilting cryocooler the motion of the displacer is very important to decide the cooling capacity, which depends upon the working gas pressure, the swept volume in the compression space and the expansion space, operating frequency, the phase shift between piston and displacer, etc. In this study, Stirling cryocooler actuated by the electric farce of the dual linear motor is designed and manufactured. Cool down characteristics of the cold end with laser displacement sensor in the expander of the Stilting cryocooler is evaluated. The charging pressure was 15kg$_{f}$/$\textrm{cm}^2$ and operating frequency was 50Hz. Input power and the lowest temperature were about 32W and 67K, respectively. And, displacement of the piston is measured by LVDTs (Linear Variable Differential Transformers), displacement of thedisplacer is measured by laser optic method, and phase shift between piston and displacer is discussed. As the peak-to-peak pressure of the compressor was increased, peak-to-peak displacement of the displacer was increased. The peak-to-peak displacement of the displacer increases in the range of 0 - 64.5Hz(resonant frequency of the displacer), but decreases steeply when the operating frequency is bigger than the resonant frequency. Finally when the phase shift between displacements of the Piston and displacer is 45。, operating frequency is optimum and is decided by resonant frequency of the expander, mass and cross section area of the displacer and constant by friction and flow resistance.e.

터널 시공 중 3차원 절대변위 계측시스템의 개발과 적용 (Development of 3D absolute displacement monitoring system and its application at the stage of tunnel construction)

  • 방준호;김기영;정용훈
    • 한국터널지하공간학회 논문집
    • /
    • 제9권3호
    • /
    • pp.229-240
    • /
    • 2007
  • 터널 및 지하공간 시공 중 일상계측에서의 계측관리 효율성 및 고급의 내공변위 분석을 위해 3차원 광파기, 선단앵커정착형 타겟부착장치, 절대변위 계측관리 프로그램으로 구성된 3차원 절대변위 계측시스템을 구축하였다. 본 연구를 통해 3차원 절대변위 계측에 필요한 광파기의 종류와 사양을 제시하였고, 기존 타겟부착장치의 문제점을 개선한 선단앵커정착형 타겟부착장치에 대한 성능시험을 수행하여 우수한 시준거리와 측정정밀도를 확인하였다. 또한 절대변위 계측관리 프로그램에 대한 현장성능시험을 수행하여 얻어진 경향선/영향선 등 다양한 분석방법을 활용하여 막장전방의 연약대 존재 예측이 가능하였고, TSP탐사결과와 비교하여 정확성을 확인하였다.

  • PDF

한의사 맥진 가압력 재현에 대한 고찰 (Considerations on an Oriental Medical Doctor like Indentation System)

  • 이전;우영재;전영주;이유정;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.113-119
    • /
    • 2008
  • In pulse diagnosis, the indentation pressure is one of the most important factors as well as the change of pulse shape and the distribution of pressure via time. But, on the oriental medical doctor's indentation pressure control, the understandings of the neurophysiological meanings and mechanisms have been lacked. So, in this paper, we considered on these issues and then proposed a proper system which can imitate the OMD's indentation pressure control mechanisms. As a result, both tactile information and kinesthetic information were found to be essential to the indentation pressure control so that a system, which can measure both the physical indent pressure and the displacement of an indentation arm, has been proposed. With this proposed system, while the indentation was being controlled through the moving step number of the step motor, the physical indentation pres sure and displacement of the indentation arm were measured. From these measured data, the relationships between the moving step number and both physical indentation pressure and displacement were revealed to have linear characteristics in early phase and to have nonlinear characteristics in latter phase. Additionally, three types of graph were generated whose X axis means the moving step number, the physical indentation pressure and the displacement respectively and Y axis means the pulse pressure. By comparing these graphs, we come to conclude that different concepts on indentation pressure control cause different diagnostic results on floating/sinking degrees for the same subject. Consequently, an indentation system for the pulse diagnosis should be able to provide both the tactile information and kinesthetic information, that is, the physical indentation pressure and the displacement of the indentation arm. In future, the proposed system should be optimized to the pulse diagnosis environment and how to combine the both information for more reliable diagnosis should be studied.

  • PDF