• 제목/요약/키워드: measured displacement

검색결과 1,719건 처리시간 0.032초

나노구조 단분자막의 전기적 특성 연구 (A Study of Electrical Characteristics of Nano-Structural Monolayers)

  • 송진원;신훈규;이경섭;최용성
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.586-590
    • /
    • 2006
  • Dendrimers represent a new class of synthetic macromoleculcs characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The azobenzene dendrimer is one of the dendrimeric macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and photoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current. Functional photoisometrization organic molecular the photo-stimulus to organic monomolecular L films and LB films of dendrimer and 8A5H were performed. The 8A5H organic monolayer in case of pressure stimulus occurred that positive course but in case of the photo-stimulus compared positive and negative. It is assumed that generation forms of displacement current were measured when photo-stimulus for impression.

화장편마암에 근입된 단일현장타설말뚝의 수평거동특성 (Horizontal Behaviour Characteristics for Single Drilled Shaft Embedded in Granite Gneiss)

  • 여규권
    • 지질공학
    • /
    • 제18권4호
    • /
    • pp.493-499
    • /
    • 2008
  • 본 연구에서는 수평하중을 받는 화강편마암에 근입된 대구경현장타설말뚝에 대하여 수평방향의 거동특성을 분석하기 위하여 시험말뚝인 단일대구경현장타설말뚝 내부에 경사계를 설치하여 단계별 수평하중이 대한 심도별 변위량을 측정하였다. 실측치와 기존 이론식에 의한 계산치를 비교 분석하여 수평변위 거동특성을 평가하였다. 따라서, 단계별 재하하중에 따른 수평변위량의 계측값과 비교한 결과 전체적으로 Chang의 산정식과 유사한 결과를 나타내고 있으나 약간 과소평가 되는 경향이 있다. 그리나 유한차분법(FDM)과 p-y곡선법은 상부구간에서 과대평가 되는 경향을 나타내었다.

각변위 방식을 이용한 캡슐의 오리엔테이션 측정 방법 (Orientation Tracking Method based on Angular Displacement for Wireless Capsule Endoscope)

  • 유영선;김명유;유영갑
    • 한국콘텐츠학회논문지
    • /
    • 제8권2호
    • /
    • pp.27-32
    • /
    • 2008
  • 본 논문은 각변위 방식을 이용한 소화경로 모델링 및 경로에 대한 캡슐의 오리엔테이션 측정 방법을 제안하였다. 제안하는 방법은 캡슐 내시경의 자세를 3차원 방향벡터와 이의 회전성분으로 표현하였다. 소화경로에 대한 캡슐의 오리엔테이션 정보인 롤, 피치 그리고 요우 값은 각각 $1.6^{\circ}$ 이내의 오차를 보였다. 제안된 방법은 자기장을 이용한 오리엔테이션 측정에서 롤값 측정 문제를 해결하였다. 오일러 각을 이용한 기존의 오리엔테이션 측정 방식과 비교하여 알고리즘의 복잡도를 줄였다.

스피닝 머신용 대형주축의 열특성에 관한 연구 (A Study on the Thermal Characteristics of Spindle for the Spinning Machine)

  • 정동수;김수태;최대봉;예성봉;설상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 추계학술대회 논문집
    • /
    • pp.555-559
    • /
    • 2005
  • Spinning process is a chipless metal forming method for axis-symmetric parts, which is more economical, efficient and versatile method for producing parts than other sheet metal forming process such as stamping or deep drawing. The large-sized spindle for spinning machine is the equipment to ferm a high-pressure vessel into the demanded shape. The important problem in the spindle system fur spinning machines is to reduce and minimize the thermal effect by motor and bearings. In this study, the effect of heat generation of bearings for the large-sized spindle is considered. Temperature distribution and thermal displacement of the spindle system for spinning machine can be analyzed by using the finite element method. The numerical results are compared with the measured data. The results show that temperature distribution and thermal displacement can be reasonably estimated by using the finite element method and the three dimensional model.

  • PDF

비틀림하중을 받는 기계구조물의 ESPI를 이용한 면내변위 측정에 관한 연구 (A Study on Measurement of In-Plane Displacement using ESPI in Mechanical Structure under torsional load)

  • 장석원;이학주;최은오;정찬희
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.693-700
    • /
    • 2002
  • Recently, the mechanical structures applied to many industrial products, especially in electronic products, appear to be miniaturized and complicated. This trend makes it difficult to analyze the stress distribution of those mechanical structures and generates new challenges for precise measurement of strain. In order to solve this measurement problem many optical measurement techniques have been suggested. Among those, the ESPI(Electronic Speckle Pattern Interferometry) has been considered as one of the most useful tools. But the shortage of recognition and difficulties of measurement have limited its industrial applications in spite of its excellent capabilities. Therefore in this study, not only the verification of the FEA result but the enhancement of industrial application of ESPI was tried by measuring the in-plane displacement of mechanical structure with ESPI, which is difficult to be measured with strain gauge.

나노구조 유기초박막의 광변위특성 (Photo Displacement Properties of Nano structure Organic Ultra Thin Films)

  • 송진원;최영일;조수영;김영근;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 추계학술대회 논문집 Vol.17
    • /
    • pp.468-471
    • /
    • 2004
  • Monolayers of lipids on a water surface have attracted much interest as models of biological membranes, but also as precursors of multilayer systems premising many technical applications. Until now, many methodologies have been developed in order to gain a better understand. Photoisomerization in monolayers of a novel azobenzene compound, azobenzene dendrimer, was investigated for the first time by means of the absorption spectrum and Maxwell displacement current (MDC) technique. Dendrimers are well-defined macromolecules exhibiting a tree-like structure, first derived by the cascade molecule approach. According to the absorption spectrum, trans-to-cis conversion ratio was estimated to the third generation of azobenzene dendrimer deposited onto a glass substrate. Temperature-dependent induced charge with trans-cis isomerization was also measured by means of MDC technique.

  • PDF

In situ Stress Measurements with Submonolayer Sensitivity As a Probe of Coherent-to-incoherent Matching at an Interface in Ultrathin Magnetic Films

  • Jeong, Jong-Ryul;Kim, Young-Seok;Shin, Sung-Chul
    • Journal of Magnetics
    • /
    • 제7권4호
    • /
    • pp.151-155
    • /
    • 2002
  • In situ stress changes at interfaces of ultrathin magnetic films were measured by means of a non-contact optical fiber bundle displacement detector. A bending of the substrate due to stress of a deposited film was detected in cantilever geometry. The highest sensitivity of 134 mV/$\mu$m for the displacement detector was realized with a help of computer simulation. The detector was applied to in situ stress measurements of Co/Pt and Ni/Pd magnetic multilayer films prepared on the glass substrates by dc magnetron sputtering. The detector turned out to have a submonolayer sensitivity that enables to observe coherent-to-incoherent transition in these mismatched multilayers and even detect the stress changes within the monoatomic coverage. This highly sensitive detector paves new way to probe the stress relaxation at an interface in ultrathin films.

미소 변위 진동측정을 위한 광학 시스템 설계 및 제작 (Noncontact optical system for measurement of displacement and vibration)

  • 황웅;권진혁
    • 한국광학회지
    • /
    • 제14권3호
    • /
    • pp.260-265
    • /
    • 2003
  • 미세하게 진동하는 물체의 변위를 비접촉식으로 측정할 수 있는 광학계를 설계하고 제작하였다. 도플러효과에 의한 방법과는 달리, 하나의 볼록렌즈를 이용하여 물체 표면에 비스듬하게 입사하여 물체 표면에서 반사되는 광점의 위치 변화를 PSD(position-sensitive detector)로 검출하였다. 이러한 방법으로 전체적인 장비의 크기를 작게 하였고 빠른 응답 속도를 구현하였다. 본 장비는 $\pm$1.0 $\mu\textrm{m}$의 분해능을 나타내었으며, 스피커의 진동 실험 및 CD-ROM안에서 회전하는 C교의 진동을 측정하였다.

Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening

  • Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.410-423
    • /
    • 2019
  • Fire suppression using a water mist nozzle directly above an n-Heptane pool in a fire compartment with a door opening was numerically investigated using the Fire Dynamics Simulator (FDS) for the purpose of application in nuclear power plants. Input parameters for the numerical simulation were determined by experimental measurements. Water mist was activated 10 s after the fire began. The sensitivity analysis was conducted for three input parameters: total number of cubic cells of 6032-2,926,400, droplets per second of 1000-500,000, and extinguishing coefficient of 0-100. In a new simple calibration method of this study, the extinguishing coefficient yielding the fire suppression time closest to that measured by experiments was found for use as the FDS simulation input value. When the water mist jet flow made contact with the developed fire, the heat release rate instantaneously increased, and then rapidly decreased. This phenomenon occurred with a displacement of the flame near the liquid fuel pool. Changing the configuration of the door opening with different aspect ratios and opening ratios had impact on the maximum value of the heat release rate due to the flame displacement.

Validation of three-dimensional digital model superimpositions based on palatal structures in patients with maximum anterior tooth retraction following premolar extraction

  • Liu, Jing;Koh, Kyong-Min;Choi, Sung-Hwan;Kim, Ji-Hoi;Cha, Jung-Yul
    • 대한치과교정학회지
    • /
    • 제52권4호
    • /
    • pp.258-267
    • /
    • 2022
  • Objective: This study aimed to evaluate the superimposition accuracy of digital modes for measuring tooth movement in patients requiring anterior retraction after premolar extraction based on the proposed reference regions. Methods: Forty patients treated with bilateral maxillary first premolar extraction were divided into two groups: moderate retraction (< 7.0 mm) and maximum retraction (≥ 7.0 mm). Central incisor displacement was measured using cephalometric superimpositions and three-dimensional (3D) digital superimpositions with the 3rd or 4th ruga as the reference point. The Wilcoxon signed-rank test and linear regression analyses were performed to test the significance of the differences and relationships between the two measurement techniques. Results: In the moderate retraction group, the central incisor anteroposterior displacement values did not differ significantly between 3D digital and cephalometric superimpositions. However, in the maximum-retraction group, significant differences were observed between the anteroposterior displacement evaluated by the 3rd ruga superimposition and cephalometric methods (p < 0.05). Conclusions: This study demonstrated that 3D digital superimpositions were clinically as reliable as cephalometric superimpositions in assessing tooth movements in patients requiring moderate retraction. However, the reference point should be carefully examined in patients who require maximum retraction.