• 제목/요약/키워드: mean radiant temperature

검색결과 58건 처리시간 0.025초

다중회귀분석을 통한 PMV 모델의 단순화 (Simplification of PMV through Multiple Regression Analysis)

  • 문용준;노광철;오명도
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.761-769
    • /
    • 2007
  • The purpose of this study is to present a simplified model of predicted mean vote (PMV) using multiple regression analysis. We performed the experiments and the numerical calculations in the lecture room during summer and winter to simplify PMV. And the multiple regression analysis on PMV was conducted to estimate the contribution of independent variables toward PMV. From the multiple regression analysis, we found that the effect of independent variables on PMV followed in order, clo value>air temperatur>air velocity>mean radiant temperature>relative humidity. And the simplified PMV was proposed through a few assumptions and then was compared with original PMV. They had a good agreement with each other. Additionally, we compared the simplified PMV with EDT. We expected that the simplified PMV can be more useful than EDT to evaluate the thermal comfort in the place, where radiation is dominant. But the comfort range of the simplified PMV should be adjusted to predict the exact thermal comfort in the future.

도시가로공간의 공공디자인 개선사업에 따른 열환경 개선 효과 평가 (Evaluation of Thermal Environment Improvement Effect from Public Design Improvement Project on the Urban Street Space)

  • 백상훈;시미즈아키;김학윤;정응호
    • 한국환경과학회지
    • /
    • 제20권9호
    • /
    • pp.1105-1114
    • /
    • 2011
  • In this study, thermal environment improvements throughout public design improvement project on the urban street space were compared and evaluated. Thermo-Render 3.0, 3D-CAD based thermal environment simulation program, had been used for thermal environment improvement evaluations. Followings are the results. First, clayey blocks which have low heat transfer rate and cool island effect by trees and roof gardens brought cooling effects for buildings and surface of streets. Seconds, MRT values showed low levels because of low radiant mulching materials. Thirds, roof gardens contributed to reduce heat island effect since HIP levels were affected by decreasing heat storage effect of buildings from roof gardens. As a result, reducing heat storage effect throughout selecting and arranging proper materials which would not increase heat island potentials should be performed to improve heat island effects.

도시림의 여름철 평균복사온도 저감 추정 연구 (A Study of the Urban Tree Canopy Mean Radiant Temperature Mitigation Estimation)

  • 안승만;손학기;이규석;이채연
    • 한국조경학회지
    • /
    • 제44권1호
    • /
    • pp.93-106
    • /
    • 2016
  • 이 연구는 제안한 평균복사온도의 차감비교기법을 통해 도시림이 여름철 옥외 환경에 미치는 온열완화를 정량적으로 추정하고 평가는 것을 목적으로 한다. 항공 라이다 측량시스템 기반 3차원 점군자료로부터 도시림이 있는 모의 대상지와 도시림이 없는 모의 대상지 두 사례를 구축하여 SOLWEIG 기반에서 평균복사온도를 산출하고 두 값들을 비교 및 분석하였다. 연구를 통해 도시림 캐노피가 연구지역 전체 일평균 $T_{mrt}$를 약 $5^{\circ}C$ 정도 저감하며 태양의 위치와 지면 조건에 따라 시간평균 $T_{mrt}$$33^{\circ}C$까지 저감될 수 있음을 확인하였다. 결과들은 도시미기후 지표(풍속, 습도, 대기 온도 등) 및 생명기상(인지온도 등) 연구들을 향상시키고 더불어 삼림 기반 공공 녹색정책 개발에 활용될 수 있을 것이다.

고밀도 주거지역에서의 복사플럭스 영향 연구 - 서울시 중랑구 지역을 대상으로 - (Radiation Flux Impact in High Density Residential Areas - A Case Study from Jungnang area, Seoul -)

  • 이채연;권혁기;프레드릭 린드버그
    • 한국지리정보학회지
    • /
    • 제21권4호
    • /
    • pp.26-49
    • /
    • 2018
  • 본 연구는 도시지역을 대상으로 태양복사모델링을 수행하고 검증하여, 도시 내 열스트레스 완화에 대한 적용 가능성을 논의하였다. 이를 위해 연구지역은 항공 LiDAR 자료를 기반으로 실제 건물과 식생의 형태와 높이가 구현되었고, 보행자높이에서의 단파 및 장파복사 플럭스가 모의될 수 있도록 해상도를 향상시켰다. 고층 및 저층 건물이 고밀도로 존재하는 주거지역 $4km^2$에서 SOLWEIG 모델을 이용하여 복사플럭스를 모의하고, 지표에너지수지시스템의 Net radiometer를 이용한 복사플럭스 관측자료로 검증하였다. 그 결과 여름철 맑은 날 가장 높은 정확도를 나타냈고, 같은 날에 대한 평균복사온도를 모의한 결과, 그림자영향이 적은 저층 건물지역과 도로표면에서 가장 높은 수치를 나타냈으며, 고층 건물지역과 식생지역에서는 그림자의 영향으로 상대적으로 낮은 수치를 나타냈다. 본 연구에서 제안된 방법은 보행자높이에서 도시 내 열스트레스 지역 관리를 위한 높은 신뢰도를 보여주었다. 더욱 확장되고 있는 도시재생 및 재개발에 있어서, 새로운 주거환경을 도입하기 위해 도시 기반시설을 계획할 때 자연 및 인공 도시환경 설정과 관련된 많은 기능이 적용될 수 있다.

공간 구조별 열쾌적성 평가와 열환경 개선방안 (An Evaluation of Human Thermal Comfort and Improvement of Thermal Environment by Spatial Structure)

  • 이정아;정대영;전진형;이상문;송영배
    • 한국조경학회지
    • /
    • 제38권5호
    • /
    • pp.12-20
    • /
    • 2010
  • 본 연구는 도시 소공간의 열환경을 개선하기 위한 방안을 모색하고자 공간 구조별 열특성을 평가하여 분석하였다. 도심 내 위치한 고려대학교 캠퍼스를 연구 대상지로 선정하였으며, 대상지 내에 공간 유형을 대표하는 각각의 장소에서 열환경을 조사하였다. 기상장비를 활용한 미기상 및 바이오 기상 측정, 어안렌즈 촬영사진(Fish-eye lens photography)를 활용한 공간구조 및 특성 분석, 그리고 온도나 습도와 같은 기상정보 및 이미지 정보를 활용한 열쾌적성 모델링의 순서로 공간의 열환경 및 인체 열쾌적성을 분석하였다. 열환경 평가 결과, 인체 열쾌적성의 정도는 캠퍼스 공간의 유형에 따라 차이가 나타났다. 건물이나 수목 등에 의해 위요된 폐쇄형 공간 유형에서 개방형 공간 유형에서 분석된 평균 복사온도, PMV, PET 지수보다 더 양호한 것을 알 수 있었다. 이러한 결과는 수목과 건물에 의한 태양복사열의 차단 및 그림자의 영향을 받기 때문이라고 할 수 있다. 그러므로 공간을 계획할 때 개방성이나 통풍성을 높이기 위한 수목의 배치를 고려하고 복사열을 차단할 수 있는 바닥포장이나 건물 외장재 종류를 선택할 필요가 있다. 본 연구는 도시 공간의 이용자가 실제적으로 느끼는 열쾌적성의 정도를 정량화하고 이를 평가함으로써 이용자를 고려한 공간계획 방안을 제안하였다.인체 열쾌적성을 평가하는 정량적 평가 방법 및 그에 따른 연구결과는 향후 도시 공간의 쾌적한 환경을 조성하는데 기여할 수 있을 것으로 판단된다.

가로수와 바닥 포장 표면 알베도의 도시 열 환경 개선 효과 (Impact of Urban Thermal Environment Improvement by Street Trees and Pavement Surface Albedo)

  • 김나연;김은섭;윤석환;박정강;김상혁;남상준;제화준;이동근
    • 한국환경복원기술학회지
    • /
    • 제26권1호
    • /
    • pp.47-59
    • /
    • 2023
  • Due to climate change and urbanization, abnormally high temperatures and heat waves are expected to increase in urban and deteriorate thermal comfort. Planting of street trees and changing the albedo of urban surfaces are the strategies for mitigating the thermal environment of urban, and both of these strategies affect the exposure and blocking of radiative fluxes to pedestrians. After measuring the shortwave and longwave radiation according to the ground surface with different albedo and the presence of street trees using the CNR4 net radiometer, this study analyzed the relationship between this two strategies in terms of thermal environment mitigation by calculating the MRT(Mean Radiant Temperature) of each environment. As a result of comparing the difference between the downward shortwave radiation measured under the right tree and at the control, the shortwave radiation blocking effect of the tree increased as the downward shortwave radiation increased. During daytime hours (from 11 am to 3 pm), the MRT difference caused by the albedo difference(The albedo of the surfaces are 0.479 and 0.131, respectively.) on surfaces with no tree is approximately 3.58℃. When tree is present, the MRT difference caused by the albedo difference is approximately 0.49℃. In addition, in the case of the light-colored ground surface with high albedo, the surface temperature was low and the range of temperature change was lower than the surrounding surface with low albedo. This result shows that the urban thermal environment can be midigate through the planting of street trees, and that the ground surface with high albedo can be considered for short pedestrians. These results can be utilized in planning street and open space in urban by choosing surfaces with high albedo along with the shading effect of vegetation, considering the use by various users.

여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향 (Pergola's Shading Effects on the Thermal Comfort Index in the Summer Middays)

  • 류남형;이춘석
    • 한국조경학회지
    • /
    • 제41권6호
    • /
    • pp.52-61
    • /
    • 2013
  • 본 연구는 여름철 낮 그늘시렁의 차양이 온열쾌적 지표에 미치는 영향을 파악하고자 수행하였다. 이를 위해 여름철 차양 및 겨울철 방풍을 고려하여 갈대발로 천개면 등을 차폐한 3가지 유형의 그늘시렁(가로 4m${\times}$세로 4m${\times}$높이 2.7m) I(천개면 차폐) II(천개면, 서향면 차폐) III(천개면, 서향면, 북향면 차폐)을 4층 옥상에 구축하였다. 그리고 1차 실험은 2013년 8월 14일부터 16일까지 대조구, 그늘시렁 I, III을 대상으로, 2차 실험은 2013년 8월 26일부터 28일까지 대조구, 그늘시렁 I, II를 대상으로 기상변수(기온, 습도, 복사, 풍속)를 측정하였다. 그늘시렁의 차양이 인체가 흡수하는 복사환경과 $T_{mrt}$$SET^*$에 미치는 영향은 다음과 같다. 그늘시렁의 차양으로 인해 인체가 흡수한 복사량의 저감은 단파복사가 장파복사에 비해 훨씬 크게 나타났다. 대조구 대비 인체가 흡수한 단파복사량 차이의 최댓값 ${\Delta}K_{abs,max}$는 그늘시렁 I과 III에서는 $-119W/m^2$$-158W/m^2$였으며, 그늘시렁 I과 II에서는 $-145W/m^2$$-159W/m^2$였다. 대조구 대비 인체가 흡수한 장파복사량의 차이의 최댓값 ${\Delta}L_{abs,max}$는 그늘시렁 I과 III에서는 $-15W/m^2$$-17W/m^2$였으며, 그늘시렁 I과 II에서는 $-8W/m^2$$-7W/m^2$였다. 그늘시렁의 차양에 의해 인체가 흡수한 $T_{mrt}$$SET^*$ 값도 낮아졌다. $T_{mrt}$는 1차 실험에서는 그늘시렁 I과 III에서 각각 최대 $16.0^{\circ}C$$21.4^{\circ}C$, 그리고 2차 실험에서는 그늘시렁 I과 II에서 각각 최대 $18.8^{\circ}C$$20.8^{\circ}C$ 저감되었다. $SET^*$는 1차 실험에서는 그늘시렁 I과 III에서 각각 최대 $2.9^{\circ}C$$2.6^{\circ}C$ 그리고 2차 실험에서는 그늘시렁 I과 II에서 각각 최대 $3.5^{\circ}C$$2.6^{\circ}C$ 저감되었다. 대조구 $SET^*$ 대비 그늘시렁 II, III의 $SET^*$ 저감효율은 그늘시렁 I에 비해 낮게 나타났는데, 이는 풍속의 차이 때문이었다. 따라서 그늘시렁 수직면의 차폐시에는 차양 못지않게 통풍을 고려하는 것이 필수적이라 생각된다. 대조구의 3일간 평균 최고기온이 $37.5^{\circ}C$였던 1차 실험기간 결과에서는 $SET^*$ 값이 하루 중 대부분 시간대에서 온열 쾌적대 및 수용대의 상한 값인 $28.7^{\circ}C$$30.4^{\circ}C$를 초과하였다. 반면에 대조구의 3일간 평균 최고기온이 $34.4^{\circ}C$였던 2차 실험결과, $SET^*$ 값이 그늘시렁 I에서는 18~12시와 오후 14~18시, 그늘시렁 II는 15~18시에만 온열 쾌적대에 드는 것으로 나타났다. 반면에 그늘시렁 I, II에서 $SET^*$ 값은 하루 중 대부분 시간대에서 온열 수용대에 드는 것으로 나타났다. 따라서 혹서기에 그늘시렁의 온열쾌적성을 확보하기 위해서는 갈대발 등에 의한 차양뿐만 아니라, 덩굴식물이나 녹음수에 의한 차양을 도입하는 방안을 강구하여야 할 것이다. 그리고 그늘시렁의 차양효과를 평가하는 지표로서 $T_{mrt}$$SET^*$는 실효성이 있었다고 판단되며, 향후 옥외 조경공간의 온열환경 평가 지표로서 활용이 기대된다.

바닥온도와 실내 환기에 따른 인체반응 및 실내공기질 분석 (An Analysis of Human Reaction & IAQ Analysis by Changing the Floor Temperature & Ventilation)

  • 이지원;진경일;김세환
    • KIEAE Journal
    • /
    • 제15권1호
    • /
    • pp.97-102
    • /
    • 2015
  • Recently many buildings are airtight, deterioration takes the high stage. As this room ventilation is increasingly difficult, the importance of indoor air was emphasized. And Got a few provisions on the indoor ventilation, the building is used for other purposes also requires a lot of careful research. In this study, consisting of floor heating ventilation in the room and wants to know the impact on the human body react with the carbon dioxide concentration in the indoor air were investigated PMV. We have get the data through the experimental study like this. It can be inferred correlations of ventilation and temperature according to human comfort that you should consider when using the work of residential buildings in accordance with the changing social conditions and social. It is also determined that in the future through additional experiments related data can be established basic experimental data.

Unsteady-state CFD 시뮬레이션을 이용한 여름철 공동주택 외부공간의 온열환경 및 쾌적성 평가 (Evaluation of the Thermal Environment and Comfort in Apartment complex using Unsteady-state CFD simulation)

  • 전미영;이승재;김지영;이승복;김태연
    • KIEAE Journal
    • /
    • 제10권4호
    • /
    • pp.67-73
    • /
    • 2010
  • As more and more people desire to live in an apartment complex with a comfortable outdoor space, many construction company became interested in outdoor design. In order to increase the use of outdoor space and create the most pleasant environment, outdoor thermal environment and comfort should be evaluated quantitatively from the design stage. This study utilized ENVI-met 3.1 model to analyze outdoor thermal environment in apartment complex, and evaluated outdoor thermal comfort in 6 points of apartment complex. The physiologically equivalent temperature(PET) was employed as a outdoor thermal index. Playground B had a poor thermal environment with the maximum PET $43^{\circ}C$ (Very hot). Because shading by building and tree didn't affect outdoor thermal environment of playground B. To design comfortable outdoor space from the view point of thermal environment, the factors influencing Mean radiant temperature(MRT) and wind speed should be considered in design stage. Since it is difficult to control outdoor thermal environment compared with indoor environment, we should take into account an assessment for outdoor thermal environment and comfort in outdoor design stage.

VISIBLE REAL AREA OF AVERAGE KOREAN ADULT

  • 손철수
    • 한국주거학회논문집
    • /
    • 제7권1호
    • /
    • pp.49-54
    • /
    • 1996
  • 이 연구의 목적은 표준 한국 성인을 구성하고 있는 3012개의 삼각형들의 각각의 실제면적과 임의의 좌표에서 볼 수 있는 각 삼각형의 실제 면적을 구하는 방법을 기술하고자 한다. 이 방법을 이용한 결과들은 표준 한국 성인의 투사 면적, 임의의 좌표에서 볼 수 있는 실제 투사면적, 형태 계수, 그리고 Mean Radiant Temperature 을 구하는데 꼭 필요한 자료들이다. 이 논문은 네단계로 구성되어 있는데, 그것들은 1) 시점의 Cartesian 좌표, 2) 실제 삼각형들의 면적 계산방법, 3) 가려진 삼각형들을 포함한 실제 삼각형들의 면적 계산방법, 그리고 4) 가려진 삼각형들을 제외한 보이는 삼각형들의 면적 계산방법이다. 이 방법을 이용한 임의의 좌표에서 볼 수 있는 표준 한국 성인의 실제 면적은, 시점의 좌표가 ALFA 15.0도, BETA 0.0도 일 경우가 가장 큰 면적(7.13817$cm^2$)을 볼 수 있고, 가장 적은 면적(2,326.6$cm^2$)은 ALFA 0.0도, BETA 90.0도 일 경우이다.

  • PDF