• Title/Summary/Keyword: mean radiant temperature

Search Result 58, Processing Time 0.022 seconds

Evaluation of the Indoor Thermal Comfort in Consideration of the Solar Radiation (태양 일사를 고려한 실내 열쾌적성 평가 연구)

  • Kim Se-Hyun;Noh Kwang-Chul;Oh Myung-Do
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1140-1148
    • /
    • 2004
  • Recently the Predicted Mean Vote (PMV) has been used as an important index to evaluate the degree of the indoor thermal comfort in modern residential buildings. It is known that the PMV is mainly affected by four major factors, which are the air temperature, the air velocity, the humidity and the mean radiant temperature (MRT). Through the numerical calculation of the temperature and the modeling of the mean radiant temperature considering the solar radiation, we proposed the new modeling strategies of the mean radiant temperature and investigated the PMV index and evaluated the MRT. Also, we compared the numerical results with the experimental values. As the results, we found out that the MRT is affected by the wall temperature and the solar radiation. We also knew that the new modeling strategies of the mean radiant temperature is a more correct way of PMV calculation. Especially, the new modeling is necessary for the spaces like an atrium and large rooms with windows mainly influenced by solar radiation.

Comparison of Forced Air Warming and Radiant Heating on Body Temperature and Shivering of Post-operative Patients (수술 후 가온방법에 따른 체온과 전율의 변화)

  • Choi, Kyoung-Hee
    • Korean Journal of Adult Nursing
    • /
    • v.20 no.1
    • /
    • pp.135-148
    • /
    • 2008
  • Purpose: This study compared the effects of forced air warming and radiant heating on body temperature and shivering of patients with postoperative hypothermia. Methods: The quasi-experimental study was conducted with two experimental groups who had surgery under general anesthesia; 20 patients of group 1 experimented with the Bair Hugger as a forced air warming and 20 patients of group 2 experimented with the Radiant heater. The study was performed from July 3 to August 31, 2006 in a recovery room of an university hospital in a city. The effects of the experiment were measured by postoperative body temperature and chilling score at arrival and after every 10 minutes. The data were analyzed by t-test or ${\chi}^2$-test, repeated measures ANCOVA using SPSS/WIN 12.0. Results: The mean body temperature showed differences between the Bair Hugger group and Radiant Heater group at 40 minutes(F=-2.579, p=.034), 50minutes(F=-2.752, p=.027), and 60 minutes(F=-2.470, p=.047) after arrival to the recovery room. So, hypothesis 1 was partially accepted. The mean score of shivering showed differences between the Bair Hugger group and the Radiant Heater group, but it had no significant meaning. Hypothesis 2 was not accepted. Conclusion: We need more study to explore the effects and side effects of heating modalities to select a more effective heat treatment. The efficiency of heat modalities with regards to cost benefit, time consumption, and patients' discomfort such as burns should be considered.

  • PDF

An analysis of the thermal characteristics for optimal design and operation of the radiant heating panels (복사난방패널의 설계 및 운전을 위한 열적 특성 분석)

  • Lee, T.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.180-188
    • /
    • 1997
  • The theoretical analysis and experiment with simulator were performed to obtain the temperature distributions in radiant heating panel and heat supply from hot water to heating space for the purpose of the development of comfortable living space from a point of view of the improvement of air quality and the enhancement of system efficiency. The relations of various parameters, such as pipe pitch, room temperature as well as flow rate and temperature of hot water and so on, with the rate of heat supplied, mean temperature and maximum temperature difference at panel surface were discussed. The effects of these parameters were also verified on the thermal performance of heating panel using the relations which could be used for the optimal design and operation of the radiant heating panel.

  • PDF

On the Characteristics of Globe Temperature Variation Observed at Downtown in Summer Season (하계에 도심지에서 관측된 흑구온도의 특성 분석)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Park, Gil-Un
    • Journal of Environmental Science International
    • /
    • v.17 no.8
    • /
    • pp.907-918
    • /
    • 2008
  • In order to monitor the impact of high temperature which is seen frequently with climate change, we investigated the monthly change in globe temperature, air temperature, mean radiant temperature and effective radiant heat flow, because the four well reflect thermal radiation from bio-meteorological aspect. Both globe temperature and air temperature showed an increasing trend every month. Compared to air temperature, globe temperature had a wider range of temperature change and was more influenced by meteorological element such as precipitation. Diurnal trends of air temperature, globe temperature and the difference between their temperature had the lowest value before the sunrise and the highest around $1300{\sim}1500$ LST, showing the typical diurnal trends. Globe temperature and the difference between their temperature had a sharp increase around $1000{\sim}1100$ LST, maintained high value until 1700 LST and then reclined, though varied by month. The difference between globe temperature and air temperature was highly dependent on the amount of precipitation and clouds. The duration in which globe temperature was higher than air temperature was the lowest in July. Therefore the amount of precipitation was the most affecting, followed by the amount of clouds and wind. In order to find out the diurnal trends of temperature in city center and city outskirts, we assumed the roof of a concrete build ing as a city center, and the grass-covered observatory of the Gimhae International Airport as city outskirts. The diurnal trends of temperature in the two sites showed a strong correlation. The highest and lowest temperature also had the same trend.

A study on the comfort thermal environment by the Draft in floor panel heating system (바닥면복사난방에서 Draft에 의한 쾌적열환경에 관한 연구)

  • KyungHeeLee
    • Journal of the Korean housing association
    • /
    • v.7 no.2
    • /
    • pp.121-129
    • /
    • 1996
  • This study was to estimate how about various effects on the body thermal sensation as air velocity. clo. mean radiant temperature and resultant temperature are varied. The indoor thermal environment elements are measured under the five different of air velocity. Using the above considerations. the following results are obtained. ▶ The states, the air velocity under 0.5 m/s and 0.63 to 0.9 clo. were shown that the comfort zone of mean radiant temperature by 21.2~24.7C, the neutral point by 22.8C, the resultant temperature by 20.7-24.4C and the neutral point by 22.6C. ▶ On equal condition, the draft was occurred at a given air-velocity under 0.5m.s. It was also appeared the floor panel heating system affecting the body thermal sensation by the subject’s below-chest parts and the local discomfort by sensations on the feet and the knees.

  • PDF

Thermal Comfort Range of Radiant Floor Heating System by Residential Style (생활특성에 따른 바닥복사난방 공간의 열쾌적 범위에 관한 연구)

  • Kim, Sang-Hun;Chung, Kwang-Seop;Kim, Young-Il
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.1
    • /
    • pp.7-14
    • /
    • 2015
  • This study has been purposed to provide thermal comfort range in accordance with the residential style of radiant floor heating space, and to compare it with the thermal comfort range at predicted mean vote. The survey for the thermal sensation vote to the subjects and the measurement of environmental factors has been executed, and regression analysis has been performed. It is interpreted that the combination of the physical factor and the psychological factor results lower neutral point of the floor sitting style than that of the chair sitting style. There are some difference between the measured predicted mean vote and the thermal sensation vote via survey, which appears to be caused by distinctive heat transfer characteristic of floor radiant heating space, such as, high radiant temperature and contact thermal sensation of floor surface.

Evaluation of the Outdoor Radiant Thermal Environment by Building Scale and Block Type of Office Building in Summer (사무소건물의 규모 및 배치유형에 따른 하기 옥외 복사열환경 평가)

  • Park, Su-Jin;Jung, Sun-Young;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.6
    • /
    • pp.81-87
    • /
    • 2009
  • The purpose of this study is to evaluate of the outdoor thermal environment by building scale and block type as variable factors. In this study, 18 cases of office in central business district that have different condition are compared about their surface temperature, HIP(Heat Island Potential), and MRT(Mean Radiant Temperature). They are simulated with 3-dimension numerical simulation software named Hoyano-model. The output results contain visualized distribution chart and numerical data. The results of evaluation are as follows. (1)The surface temperature of the building becomes higher as building coverage ratio is higher but floor area ratio is lower. In same conditions, unified block type is maximum $3.2^{\circ}C$ higher than divided block type. (2)HIP shows different daily pattern as block type. During daytime, divided block type is much higher than unified block type but after sunset, it is changed. (3)MRT shows different distribution pattern as sunlight moves expecially at noon. (4)As the results of this study, cases that have high floor area ratio condition show lower surface temperature by tendency to stay low indoor temperature in office building and big rate of windows on building surface.

The Thermal Environment and Thermal Reaction in the Radiant Floor Heating System (바닥난방의 온열환경 및 열적반응에 관한 연구 -방바닥에 누운 상태를 중심으로-)

  • 이무진
    • Journal of the Korean housing association
    • /
    • v.10 no.1
    • /
    • pp.75-84
    • /
    • 1999
  • The purpose of this study is to identify the characteristics of the thermal environment, and to analyze the relationship between the thermal reactions and the skin temperatures in the lying position in the radiant floor heating system. The results are as follows: 1) The globe temperature was nearly equal to the operative temperature in the room. 2) The floor surface temperature and the globe temperature were 26.4$^{\circ}C$ and 23.6$^{\circ}C$, respectively when the whole body temperature was at neutral point. 3) The mean temperature of the six skin parts was 31.3$^{\circ}C$ (cold thermal environment); 34.1$^{\circ}C$ (neutral thermal environment); 35.1$^{\circ}C$ (hot thermal environment).

  • PDF

Visible Project Area for Korean Child (Six Years Old) in Radiant Enclosures (한국 어린이를 위한 복사 공간에서의 투사 면적에 관한 연구)

  • 손철수;최민권
    • Journal of the Korean housing association
    • /
    • v.11 no.4
    • /
    • pp.77-84
    • /
    • 2000
  • The purpose of this paper is to find a visible project area for an average six year old Korean child in radiant enclosures having standing pose. The results using this method will be necessary to find effective radiation area, effective radiation area factor, form factor, and mean radiant temperature for an average six years old Korean child consists of 3012 triangles. The methods to find visible project area of an average six years old Korean at arbitrary view point will be presented. The visible project area for Korean child is needed for evaluating thermal comfort for six years old Korean child. The biggest visible project area of an average six years old Korean is $\textrm{cm}^2$$2.061.0\textrm{cm}^2$ at the view point of alfa 0.0 degree and beta 0.0 degree, and the smallest visible real area of an average six years old Korean is $567.1\textrm{cm}^2$ at the view point of alfa 15.0 degree and beta 90.0 degree.

  • PDF

Comparison of Experimental and FDS Data for Calculating Heat-Affected Range in Forest Fires (산불 열영향 범위 산정을 위한 실험 및 FDS 데이터 비교)

  • Kim, H.S.;Kang, Y.J.;Kim, J.H.;Kim, K.H.;Lee, B.D.;Kim, Jeong Hun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.4
    • /
    • pp.91-96
    • /
    • 2014
  • This research deals with the combustion experiment of pine trees, which are the most representative species in Korea. Experimental data are compared with theoretical ones using Fire Simulation Program(FDS). It is considered that horizontal/vertical temperature distribution and radiant heat influence on adjacent areas in fire scenes. The linear function for separation distance to temperature was drawn by applying Stefan-Boltzmann's law; $y=112.13133{\times}({\sigma}T^4)^{-0.52916}$ for calculating the separation distance. In combustion experiment, the radiant heat came to $1.4{\sim}1.5kW/m^2$ in case of the separation distance by one meter. The numerical values mean that human body show the critical level of pain after one minute without a protective equipment.