• 제목/요약/키워드: mean closed set

검색결과 22건 처리시간 0.019초

일 병원에서의 병원감염관리활동 사례연구 (A Case Study on Nosocomial Infection Control Activities in A General Hospital in Pusan)

  • 배영순
    • 한국의료질향상학회지
    • /
    • 제2권2호
    • /
    • pp.156-171
    • /
    • 1996
  • Background: Nosocomial infection control is one of important means to assure the quality of medical care in the hospital, however, it has been neglected by most of the hospital personnels. Of nosocomial infections, urinary tract infection is the highest incidence, which is related to the indwelling catheter. It is, therefore, necessary to pay primary attention to the patients with the indwelling catheter in intensive care unit in order to control nosocomial Infection and to improve the quality of medical care in the hospital. Methods : The subjects of this study were patients with indwelling catheter who were admitted to the ICU of Pusan Paik Hospital from March 1994 to May 1995. The author calculated UTI rate among the subjects through the cultivation of the urine, identified the related factors of the UTI through brain storming of study team and head nurses working at ICU, and analized the effectiveness of the proposed approaches through comparing the infection rates of before and after activities. Results : The major activities carried out by the study team were to conduct in-service education programs for the staffs working at ICU about the importance of the nosocomial infection control in QA, and nursing intervention to reduce the UTI rate among the patients with indwelling catether. 1. The major nursing interventions that the study team had implemented were as follows ; 1) Drainage system was changed from partial open system to completely closed system. 2) Bladder irrigation which was routinely practised in all patients stopped among the noninfected patients. 3) Bladder irrigation set was changed to the disposable one. 4) Catheter was inserted under the anesthesia for patients to be operated. 5) Male patient receiving wrapped with gauze after perineal care was not wrapped. 6) Clamp which had not been before was newly attached to drainage tube. 7) Urine bag which had been packed into a lot of pieces was done into each piece. 8) The interval of change of indwelling catheter had regularly been four weeks, however it was used continously until it worked well. 9) Catheter was attached well at the defined site. 10) Paper towel was used instead of cotton towel. 11) Mats at the entrance were removed and cleansing of wards was enhanced. 2. The UTI rate by month was 34.4% in maximum and 9.8% in minimum during the period of this study, however it had gradually decreased. After 6 months from initiating infection control activities, the trend of rates was relatively stable. It was identified that UTI rate was different by season 12.5% in winter and 27.2% in summer. 3. Utilization rate of indwelling catheter was maintained at under 50%, but it was increased above 57% from April 1995. 4. The number of bladder irrigation sets used per day was 33.3 sets in maximum and 2.8 sets in minimum. The number used per day were also remarkably deceased. Conclusion : It was found that a program to control UTI could contribute to nosocomial infection control, and it was, in turn, a mean to assure the quality of medical care in the hospital. The nursing interventions which this study team had implemented were effective in the reduce of UTI rates.

  • PDF

밀폐형 식물생산시스템에서 상추재배를 위한 인공광원과 신개발 배지의 적용 (Applicability of Artificial Light Source and Newly Developed Growing Medium for Lettuce Cultivation in a Closed-type Plant Production System)

  • 이혜리;김혜민;김현민;박상현;황승재
    • 생물환경조절학회지
    • /
    • 제28권2호
    • /
    • pp.134-142
    • /
    • 2019
  • 본 연구는 밀폐형 식물생산시스템에서 인공광원과 배지종류에 따른 상추의 생육 특성을 조사하기 위해 수행되었다. 상추 종자는 5종류의 배지인 urethane sponge(US), rockwool(RW), Q plug(QP), TP-S2(TP)와 PU-7B(PU)가 충진된 128구 플러그 트레이에 파종하였다. 상추 종자의 발아율은 파종 후 12일까지 조사하였다. 상추 묘는 파종 후 13일째에 재순환 담액식 수경재배 시스템을 이용하여 EC $2.0dS{\cdot}m^{-1}$, pH 6.5와 온도 $25{\pm}1^{\circ}C$인 밀폐형 식물생산시스템에 정식하였다. 광원은 형광등과 RB LEDs(red:blue=7:3)를 이용하여 광주기 14/10(명기/암기), 광도 $150{\pm}10{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD로 설정했다. 상추의 초기 발아율은 TP에서 가장 높았다. 최종 발아율과 평균 발아수는 RW, QP 및 TP 배지에서 유의적으로 높았다. 초장, 엽장, 엽폭, 엽면적, 지상부의 생체중, 건물중 모두 RB LED의 QP에서 유의성 있게 높은 값을 나타냈다. 엽수, 지하부의 생체중과 건물과 SPAD는 RB LED의 QP와 TP에서 가장 좋았고, 근장은 RB LED의 TP에서 가장 길었다. 따라서 밀폐형 식물생산시스템에서 RB LED가 상추의 생육이 우수하였으며, QP와 TP가 상추의 발아율과 생육에 효과적인 것으로 나타났다. 뿐만 아니라, 밀폐형 식물생산시스템에서 상추 생산 시 신개발 배지인 TP 배지의 적용가능성을 확인하였다.