• Title/Summary/Keyword: mean acquisition time

Search Result 159, Processing Time 0.04 seconds

Real-time Fluorescence Lifetime Imaging Microscopy Implementation by Analog Mean-Delay Method through Parallel Data Processing

  • Kim, Jayul;Ryu, Jiheun;Gweon, Daegab
    • Applied Microscopy
    • /
    • v.46 no.1
    • /
    • pp.6-13
    • /
    • 2016
  • Fluorescence lifetime imaging microscopy (FLIM) has been considered an effective technique to investigate chemical properties of the specimens, especially of biological samples. Despite of this advantageous trait, researchers in this field have had difficulties applying FLIM to their systems because acquiring an image using FLIM consumes too much time. Although analog mean-delay (AMD) method was introduced to enhance the imaging speed of commonly used FLIM based on time-correlated single photon counting (TCSPC), a real-time image reconstruction using AMD method has not been implemented due to its data processing obstacles. In this paper, we introduce a real-time image restoration of AMD-FLIM through fast parallel data processing by using Threading Building Blocks (TBB; Intel) and octa-core processor (i7-5960x; Intel). Frame rate of 3.8 frames per second was achieved in $1,024{\times}1,024$ resolution with over 4 million lifetime determinations per second and measurement error within 10%. This image acquisition speed is 184 times faster than that of single-channel TCSPC and 9.2 times faster than that of 8-channel TCSPC (state-of-art photon counting rate of 80 million counts per second) with the same lifetime accuracy of 10% and the same pixel resolution.

Dual-Cell Combining Detection Method for Reduction of Residual Frequency Offset Influence on Code Acquisition Systems (나머자 옵셋이 부호획득 시스템에 미치는 영향을 줄이기 위한 듀얼셀 결합 검파 알고리즘)

  • Chong, Da-Hae;Lee, Young-Yoon;Yoon, Tae-Ung;Lee, Young-Po;Lee, Myung-Soo;Yoon, Seok-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.7C
    • /
    • pp.715-723
    • /
    • 2009
  • In this paper, we propose a new detection method called dual-cell combining (DCC) detection for the acquisition in time of spread spectrum codes in the presence of residual frequency offset (RFO). When the RFO exists, the correlation peak used for detection during the acquisition process is split into two neighboring peaks with smaller amplitudes, resulting in considerable degradation in the overall acquisition performance of conventional methods. In the DCC detection method, the decision variable for detection is formed by combining two consecutive correlator outputs so that the influence of the reduction in the correlation peak due to the RFO can be alleviated. Numerical results show that the DCC detection method can offer better mean-time-to-synchrouization performance than the conventional method based on the cell-by-cell detection.

Motor Learning in Elderly: Effects of Decision Making Time for Self-Regulated Knowledge of Results During a Dynamic Balance Task

  • Jeon, Min-jae;Jeon, Hye-seon
    • Physical Therapy Korea
    • /
    • v.23 no.4
    • /
    • pp.16-26
    • /
    • 2016
  • Background: Deficiencies in the ability to maintain balance are common in elderly. Augmented feedback such as knowledge of results (KR) can accelerate learning and mastering a motor skill in older people. Objects: We designed this study to examine whether one session of Wii-Fit game with self-regulated KR is effective for elderly people, and to compare the effect of two different timings of self-regulated KR conditions. Methods: Thirty-nine community-dwelling elders, not living in hospice care or a nursing home, participated in this study. During acquisition, two groups of volunteers were trained in 10 blocks of a dynamic balancing task under the following 2 conditions, respectively: (a) a pre-trial self-regulated KR ($n_1=18$), or (b) a post-trial self-regulated KR ($n_2=21$). Immediate retention tests and delayed retention tests of balancing performance were administered in 15 minutes and 24 hours following acquisition period, respectively. Results: In both groups, significant improvements of balancing performances scores were observed during the acquisition period. Regardless of the group, mean of balancing performance scores on retention tests were well-maintained from the final session. There were no significant differences between groups in balancing performance scores during the acquisition period (p>.05); however, the post-trial self-regulated KR group exhibited significantly higher balancing performance scores in both the immediate retention test and delayed retention test than that of the pre-trial self-regulated KR group (p<.05). Conclusion: Therefore, subjects who regulated their feedback after a dynamic balancing task, during the acquisition period, experienced more efficient motor learning during the retention period than did subjects who regulated their feedback before a dynamic balancing task. Accordingly, in case of presenting the KR of motor learning in clinical settings to elders who reduced dynamic balance abilities, the requesting time of KR is imperative according to self-estimation processes as well as types of KR and practice.

Rapid and Reliable Signal Acquisition Scheme for Noncoherent UWB Systems in Multipath Channel (다중경로 채널 환경에서 Noncoherent UWB 시스템을 위한 고속 고신뢰의 동기획득 기법)

  • Kim, Jae-Woon;Yang, Suck-Chel;Choi, Sung-Soo;Shin, Yo-An
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.141-146
    • /
    • 2005
  • In this paper, we propose to extend the TSS-LS (Two-Step Search scheme with Linear search based Second step) scheme which was already proposed by the authors for coherent UWB (Ultra Wide Band) systems, to rapid and reliable acquisition of noncoherent UWB systems in multipath channels. The proposed noncoherent TSS-LS employing simple energy window banks utilizes two different thresholds and search windows to achieve fast acquisition. Furthermore, the linear search is adopted for the second step in the proposed scheme to correctly find the starting point in the range of effective delay spread of the multipath channels, and to obtain reliable BER (Bit Error Rate) performance of the noncoherent UWB systems. Simulation results show that the proposed TSS-LS can achieve significant reduction of the required mean acquisition time as compared to general search schemes. In addition, the proposed scheme achieves quite good BER performance, which is favorably comparable to the case of ideal perfect timing.

  • PDF

PN Code Acquisition at Low Signal-to-Noise Ratio Based on Seed Accumulating Sequential Estimation (시드 누적 순차적 추정 기법을 이용한 낮은 신호대잡음비 환경에서의 의사 잡음 부호 획득)

  • 윤석호;김선용
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.9A
    • /
    • pp.678-683
    • /
    • 2003
  • The pseudo-noise (PN) code acquisition based on the sequential estimation (SE) proposed by Ward performs well only at relatively high chip signal-to-noise ratios (SNRs). In this paper, a seed accumulating sequential estimation (SASE) method and a PN code acquisition system based on it are proposed, which perform well at low chip SNR (of practical interest) also. Then, the mean acquisition time performance of the proposed system is investigated. Numerical results show that the system based on the SASE performs dramatically better than that based on the SE at low chip SNR, and the improvement becomes larger as the period of PN code increases.

Performance Analysis of Sequential Estimation Schemes for Fast Acquisition of Direct Sequence Spread Spectrum Systems (직접 수열 확산 대역 시스템의 고속 부호 획득을 위한 순차 추정 기법들의 성능 분석)

  • Lee, Seong Ro;Chae, Keunhong;Yoon, Seokho;Jeong, Min-A
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.8
    • /
    • pp.467-473
    • /
    • 2014
  • In the direct sequence spread spectrum system, the correct synchronization is very important; hence, several acquisition schemes based on the sequential estimation have been developed. Typically, the rapid acquisition sequential estimation (RASE) scheme, the seed accumulating sequential estimation (SASE) scheme, the recursive soft sequential estimation (RSSE) scheme have been developed for the correct acquisition. However, the objective performance comparison and analysis between former estimation schemes have not been performed so far. In this paper, we compare and analyze the performance of the above sequential estimation schemes by simulating the correct chip probability and the mean acquisition time (MAT).

The Quantitative Assessment of Renal Function and Size by Differences of Acquisition Counts in $^{99m}Tc$-DMSA Renal Scan ($^{99m}Tc$-DMSA 신장검사에서 획득 계수의 차이에 따른 기능 및 형태 평가)

  • Shim, Dong-Oh;Kim, Ho-Sung;Chung, Eun-Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.117-121
    • /
    • 2010
  • Purpose: In nuclear medicine study, there are two methods, preset count method and preset time method, to acquire static images. We usually use preset count method for static image in $^{99m}Tc$-DMSA renal scan, but occasionally use preset time method. In case of using preset count method, we always acquire same counts but it causes a difference of scan time. In case of using preset time method, it takes same scan time to acquire images but it causes different counts. Therefore, the purpose of this study is to investigate any differences of function and formal information in both kidney by acquisition counts Materials and Methods: From January 11, 2010 to March 31, 2010, we analyzed the 30 patients (M: 11, W: 19). who were examined by $^{99m}Tc$-DMSA scan and have one side of functioning kidney relatively between 40~60%. And the patients who have cold and hot region in image were analyzed but we did not accept images of patients when it was hard to divide kidney into cortex. There was no division between subjects and age of subjects is $14.83{\pm}22.07$ old. We used the BrightView gamma camera from PHILIPS. To analyze function and formal of kidney, we used JET stream release 3.0 version from PHILIPS. Using SPSS 12.0 program, we compared descriptive statistics and paired T-test. Images were acquired sequentially in the same parameters, but there are three methods which different from acquisition time and scan time, 100 kcounts, 300 kcounts and 7 minutes method (exceed 300 kcounts). To assess function and formal information of kidney, we measured renal relative function, geometric mean and size of kidney and analyzed each difference. Results: In case of renal relative function in both kidney, 100 kcounts method was $50.52{\pm}3.64%$. 300 kcounts method was $50.38{\pm}3.66%$ and 7 minutes method was $49.91{\pm}3.40%$ and there were no statistical significant differences between each method. In case of geometric mean, 100 kcounts method was $50.08{\pm}3.25%$. 300 kcounts method was $49.89{\pm}3.40%$ and 7 minutes method was $49.91{\pm}3.24%$. And also, there were no statistical significant differences. When comparing size of kidney, 100 kcounts method was $8.23{\pm}1.96$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.35{\pm}1.97$ cm. In case of right kidney, 100 kcounts method was $7.91{\pm}1.88$ cm. 300 kcounts method was $8.12{\pm}1.90$ cm and 7 minutes method was $8.25{\pm}1.96$ cm. From those values, we recognized that there were significant differences each method (p<0.05). Conclusion: From results of this study, there were no statistical differences in renal relative function and geometric mean by acquisition counts. However, in shape of kidney, the more acquisition counts are increasing, the more size of kidney is getting big. And there were statistical significant differences. Therefore, to perform reliable quantitative result, preset count method is more desirable than preset time method. Especially, in case of a follow-up test, if we use preset time method, it will cause differences of formal results in kidney due to acquisition counts each time we examine patients.

  • PDF

A Study of Reliability Analysis and Application on Naval Combat System Using Field Critical Failure Data (야전 치명고장자료를 이용한 함정전투체계 신뢰성 분석 및 활용 방안)

  • Kim, Young-Jin;Oh, Hyun-Seung;Choi, Bong-Wan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.4
    • /
    • pp.49-59
    • /
    • 2016
  • Naval combat system developed in-country is progressing at an alarming rate since 2000. ROK navy will be achieved all vessels that have combat system in the near future. The importance of System Engineering and Integrated Logistics Support based on reliability analysis is increasing. However, reliability analysis that everyone trusted and recognized is not enough and applied practically for development of Defense Acquisition Program. In particular, Existing Reliability Analysis is focusing on reliability index (Mean Time Between Failure (MTBF) etc.) for policy decision of defense improvement project. Most of the weapon system acquisition process applying in the exponential distribution simply persist unreality due to memoryless property. Critical failures are more important than simple faults to ship's operator. There are no confirmed cases of reliability analysis involved with critical failure that naval ship scheduler and operator concerned sensitively. Therefore, this study is focusing on Mean Time To Critical Failure (MTTCF), reliability on specific time and Operational Readiness Float (ORF) requirements related to critical failure of Patrol Killer Guided missile (PKG) combat system that is beginning of naval combat system developed in-country. Methods of analysis is applied parametric and non-parametric statistical techniques. It is compared to the estimates and proposed applications. The result of study shows that parametric and non-parametric estimators should be applied differently depending on purpose of utilization based on test of normality. For the first time, this study is offering Reliability of ROK Naval combat system to stakeholders involved with defense improvement project. Decision makers of defense improvement project have to active support and effort in this area for improvement of System Engineering.

Performance Analysis of DMF Acquisition System in Frequency-Selective Rayleigh Fading Channel (주파수 선택적 레일리 페이딩 채널에서의 DMF 초기동기 장치의 성능분석)

  • 김성철;이연우;조춘근;박형근;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1351-1360
    • /
    • 1999
  • In frequency selective channels, conventional PN code acquisition schemes are not ideal candidates. This is because they are primarily designed for the AWGN channel. In this paper, a direct-sequence spread-spectrum(DSSS) PN code acquisition system based on digital matched filtering (DMF) with automatic threshold control(ATC) algorithm is presented and analyzed with regards to probability of detection and probability of false alarm. These two important probabilities, the probability of detection ($P_D$) and the probability of false alarm ($P_{FA}$) are derived and analyzed in considering Doppler shift, sampling rate, mean acquisition time, and PN chip rate in frequency selective Rayleigh fading channel when using serial-search method as detection technique. From computer simulation results of a DMF acquisition system model, it is shown that the performance of the acquisition system using ATC algorithm is better than that of constant threshold system.

  • PDF

Pupil Size Variability as an Index of Autonomic Activity - from the Experiments of Posture, Sleepiness and Cognitive Task (자율신경활성도의 지표로서의 동공크기 변이율 -자세변화, 졸음, 인지과제 실험으로부터)

  • Lee, Jeung-Chan;Kim, Ji-Eun;Park, Kyung-Mo
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.55-65
    • /
    • 2007
  • This paper sought to investigate pupil size variability, pupil size parameters in terms of time domain and frequency domain, the autonomic activity change induced by posture change, degree of sleepiness and cognitive task (math task). With a specially designed pupil image acquisition system in the dark room, these three kinds of experiments were performed to induce a dominant state of sympathetic or parasympathetic activation. Electrocardiogram and pupil size were measured in all the experiments. Based on three experiments, we calculated heart rate variability. In the pupil size analysis, we calculated the mean and standard deviation of pupil size (in time domain), and proposed several frequency bands that exhibit different autonomic activation between different sessions. The results indicate that in terms of heart rate variability, posture change exhibited significant differences but not between sleepiness level, or between cognitive task. Pupil sizes differed only during the postures. And we found some frequency bands that correlated with autonomic activation in each experiment. While heart rate variability reflects posture change that need cardiac control, pupil size variability reflects not only posture induced autonomic activation but sleepiness and cognitive load, which is processed in the brain, in time and frequency domain parameter.