• 제목/요약/키워드: mean acquisition time

검색결과 163건 처리시간 0.035초

STRAIN AND TEMPERATURE CHANGES DURING THE POLYMERIZATION OF AUTOPOLYMERIZING ACRYLIC RESINS

  • Ahn Hyung-Jun;Kim Chang-Whe;Kim Yung-Soo
    • 대한치과보철학회지
    • /
    • 제39권6호
    • /
    • pp.709-734
    • /
    • 2001
  • The aims of this experiment were to investigate the strain and temperature changes simultaneously within autopolymerzing acrylic resin specimens. A computerized data acquisition system with an electrical resistance strain gauge and a thermocouple was used over time periods up to 180 minutes. The overall strain kinetics, the effects of stress relaxation and additional heat supply during the polymerization were evaluated. Stone mold replicas with an inner butt-joint rectangular cavity ($40.0{\times}25.0mm$, 5.0mm in depth) were duplicated from a brass master mold. A strain gauge (AE-11-S50N-120-EC, CAS Inc., Korea) and a thermocouple were installed within the cavity, which had been connected to a personal computer and a precision signal conditioning amplifier (DA1600 Dynamic Strain Amplifier, CAS Inc., Korea) so that real-time recordings of both polymerization-induced strain and temperature changes were performed. After each of fresh resin mixture was poured into the mold replica, data recording was done up to 180 minutes with three-second interval. Each of two poly(methyl methacrylate) products (Duralay, Vertex) and a vinyl ethyl methacrylate product (Snap) was examined repeatedly ten times. Additionally, removal procedures were done after 15, 30 and 60 minutes from the start of mixing to evaluate the effect of stress relaxation after deflasking. Six specimens for each of nine conditions were examined. After removal from the mold, the specimen continued bench-curing up to 180 minutes. Using a waterbath (Hanau Junior Curing Unit, Model No.76-0, Teledyne Hanau, New York, U.S.A.) with its temperature control maintained at $50^{\circ}C$, heat-soaking procedures with two different durations (15 and 45 minutes) were done to evaluate the effect of additional heat supply on the strain and temperature changes within the specimen during the polymerization. Five specimens for each of six conditions were examined. Within the parameters of this study the following results were drawn: 1. The mean shrinkage strains reached $-3095{\mu}{\epsilon},\;-1796{\mu}{\epsilon}$ and $-2959{\mu}{\epsilon}$ for Duralay, Snap and Vertex, respectively. The mean maximum temperature rise reached $56.7^{\circ}C,\;41.3^{\circ}C$ and $56.1^{\circ}C$ for Duralay, Snap, and Vertex, respectively. A vinyl ethyl methacrylate product (Snap) showed significantly less polymerization shrinkage strain (p<0.01) and significantly lower maximum temperature rise (p<0.01) than the other two poly(methyl methacrylate) products (Duralay, Vertex). 2. Mean maximum shrinkage rate for each resin was calculated to $-31.8{\mu}{\epsilon}/sec,\;-15.9{\mu}{\epsilon}/sec$ and $-31.8{\mu}{\epsilon}/sec$ for Duralay, Snap and Vertex, respectively. Snap showed significantly lower maximum shrinkage rate than Duralay and Vertex (p<0.01). 3. From the second experiment, some expansion was observed immediately after removal of specimen from the mold, and the amount of expansion increased as the removal time was delayed. For each removal time, Snap showed significantly less strain changes than the other two poly(methyl methacrylate) products (p<0.05). 4. During the external heat supply for the resins, higher maximum temperature rises were found. Meanwhile, the maximum shrinkage rates were not different from those of room temperature polymerizations. 5. From the third experiment, the external heat supply for the resins during polymerization could temporarily decrease or even reverse shrinkage strains of each material. But, shrinkage re-occurred in the linear nature after completion of heat supply. 6. Linear thermal expansion coefficients obtained from the end of heat supply continuing for an additional 5 minutes, showed that Snap exhibited significantly lower values than the other two poly(methyl methacrylate) products (p<0.01). Moreover, little difference was found between the mean linear thermal expansion coefficients obtained from two different heating durations (p>0.05).

  • PDF

연직사진과 경사사진을 함께 이용한 UAV 사진측량의 정확도 평가 연구 (A Study on the Accuracy Evaluation of UAV Photogrammetry using Oblique and Vertical Images)

  • 조정민;이종석;이병길
    • 한국측량학회지
    • /
    • 제39권1호
    • /
    • pp.41-46
    • /
    • 2021
  • 무인항공기를 이용한 데이터 취득이 널리 활용되면서 무인항공기를 이용한 사진측량의 정확도를 높일 수 있는 방안의 하나로 항공삼각측량의 번들 조정에 연직사진과 경사사진을 같이 사용하는 방법이 제시되고 있다. 본 연구에서는 사진측량의 정확도를 높이는 데 적합한 방법을 찾기 위해 촬영 각도를 달리하여 촬영한 경사사진을 조정하는 경우와 촬영 각도가 다른 경사사진을 연직사진과 동시에 조정하는 경우의 정확도를 비교하였다. 연구결과 입력되는 경사사진의 경사가 커질수록 검사점의 오차가 줄어드는 것으로 나타났으며, 특히 연직사진과 경사사진을 같이 사용할 때, 경사사진의 경사가 클수록 높이 오차가 크게 줄어드는 것으로 나타났다. 현행 『항공사진측량 작업규정』에서는 연직사진의 GSD (Ground Spatial Distance)와 동일한 RMSE (Root Mean Square Error)를 요구하고 있다. 촬영각도 50°의 경사사진을 이용할 때 이 기준에 거의 근접한 결과를 얻을 수 있었고, 연직사진과 50°의 경사사진을 동시에 조정한 경우 작업규정을 만족시킬 수 있었다. 본 연구 결과를 활용하면 무인항공기에 탑재된 저가의 사진기를 이용하는 사진측량이 더욱 활발해 질 수 있을 것으로 기대된다.

족근 관절 연부조직 충돌 증후군에서 MRI의 진단적 의의 및 관절경적 치료 결과 (Diagnostic efficacy of specialized MRI & clinical results of arthroscopic treatment in ankle soft tissue impingement syndrome)

  • 이진우;문은수;김성재;한수봉;강응식
    • 대한족부족관절학회지
    • /
    • 제7권2호
    • /
    • pp.208-217
    • /
    • 2003
  • Introduction: Soft-tissue impingement syndrome is now increasingly recognized as a significant cause of the chronic ankle pain. As a method to detect soft-tissue ankle impingement, a characteristic history and physical examination, routine MR imaging, and direct MR arthrography were used. The efficacy of routine MR imaging has been controversial for usefulness because of low sensitivity and specificity. Direct MR artrhography was recommaned for diagnosis because of the highest sensitivity, specificity and accuracy, but it requires an invasive procedure. The purpose of this study is to investigate the diagnostic accuracy of Fat suppressed, contrast enhanced, three-dimensional fast gradient recalled acquisition in the steady state with rediofrequency spoiling magnetic resonance imaging(CE 3D-FSPGR MRI) and to evaluate the clinical outcome of the arthroscopic treatment in assessing soft-tissue impingement associated with trauma of the ankle. Materials and Methods: We reviewed 38 patients who had arthroscopic evaluations and preoperative magnetic resonance imaging studies(3D-FSPGR MRI) for post-traumatic chronic ankle pain between January 2000 and August 2002. Among them, 24 patients had osteochondral lesion, lateral instability, loose body, malunion of lateral malleoli, and peroneal tendon dislocation. The patient group consisted of 23 men and 15 women with the average age of 34 years(16-81 years). The mean time interval from the initial trauma to the operation was 15.5 months(3 to 40 months), The mean follow-up duration of the assessment was 15.6months(12-48 months). MRI was simultaneously reviewed by two radiologists blinded to the clinical diagnosis. The sensitivity, specificity and accuracy of MRI was obtained from radiologic and arthroscopic finding. Arthroscopic debridement and additional operation for associated disease were performed. We used a standard protocol to evaluate patients before the operation and at follow-up which includes American Orthopedic Foot and Ankle Society Ankle-Hindfoot Score. Results: For the assessment of the synovitis and soft tissue impingement, fat suppressed CE 3D-FSPGR MR imaging had the sensitivity of 91.9%, the specificity of 84.4 and the accuracy of 87.5%. AOFAS Ankle-Hindfoot Score of preoperative state was 69.2, and the mean score of the last follow-up was 89.1. These were assessed as having 50% excellent(90-100) and 50% good(75-89). The presence of other associated disease didn't show the statistically significant difference(>0.05). Conclusion: Fat suppressed CE 3D-FSPGR MR imaging is useful method comparable to MR arthrography for diagnosis of synovitis or soft-tissue impingement, and arthroscopic debridement results in good clinical outcome.

  • PDF

Liver PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법의 유용성 평가 (Evaluation of MR Based Respiratory Motion Correction Technique in Liver PET/MRI Study)

  • 도용호;이홍재;김진의;노경운
    • 핵의학기술
    • /
    • 제22권1호
    • /
    • pp.15-22
    • /
    • 2018
  • PET/MRI 검사 시 호흡에 의한 움직임은 영상의 질 저하는 물론 종양의 크기, 표준섭취계수의 오차를 발생시키는 원인이 된다. 본 연구에서는 일체형 PET/MRI 장비에서 MR기반 호흡 움직임 보정 방법의 적용에 따른 종양의 표준섭취계수, 크기와 영상 품질 변화를 평가하고자 하였다. Biograph mMR 3.0T (Siemens, Germany)장비에서 2016년 3월부터 7월까지 $^{18}F-FDG$ liver PET/MRI 검사를 시행한 30명 ($62.5{\pm}10.2$세)의 데이터를 분석하였다. 7분의 PET listmode 데이터를 획득하는 동안 MR 기반 호흡 움직임 보정 방법인 MAG, MTG와 NG T1 weighted MR 영상을 획득하였다. Gated PET 영상의 재구성은 35% efficiency window가 적용된 MAG와 MTG로부터 획득된 감쇄보정영상을 이용하여 시행하였다. Non-gate, MAG, MTG 영상에서 측정된 종양의 표준섭취계수와 Z축 방향의 크기 그리고 반치폭을 분석하였다 평균 $SUV_{max}$$SUV_{peak}$는 NG 대비 MAG 13.15%(P<0.0001), 8.66%(P<0.0001), MTG 13.27%(P<0.0001), 8.80%(P<0.0001) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 MAG 14.47%(P<0.0001), 15.49%(P=0.0004), MTG 14.89%(P<0.0001), 15.79%(P=0.0003) 감소하였으며 통계적으로 유의한 차이를 보였다. MAG와 MTG 비교 평가에서 MTG의 $SUV_{max}$$SUV_{peak}$는 MAG 대비 0.07%(P=0.8802), 0.13%(P=0.7766) 증가하였으며 Z-축에서 평균 종양의 크기와 반치폭은 0.49%(P=0.2786), 0.36%(P=0.2488) 감소하였다. 약 7분과 2분의 추가 검사시간이 필요한 MAG와 MTG에서 표준섭취계수와 종양의 크기, 반치폭에서 통계적으로 유의한 차이가 없었다. 간 PET/MRI 검사 시 MR 기반 호흡 움직임 보정 방법을 적용하였을 때 NG 대비 MAG, MTG 모두에서 표준섭취계수와 종양의 크기 및 공간분해능이 개선되었으며 MAG와 MTG의 결과 값은 통계적으로 유의한 차이가 없었다. 호흡에 의한 움직임에 영향을 받는 다양한 상 복부 검사에 MBRMCT를 적용 시 추가적인 장비의 설치 없이 약 2분의 추가 검사시간이 필요한 MTG 방법 적용하여 NG 대비 보다 정확한 정보를 제공할 수 있을 것으로 사료된다.

Comparison of Snow Cover Fraction Functions to Estimate Snow Depth of South Korea from MODIS Imagery

  • Kim, Daeseong;Jung, Hyung-Sup;Kim, Jeong-Cheol
    • 대한원격탐사학회지
    • /
    • 제33권4호
    • /
    • pp.401-410
    • /
    • 2017
  • Estimation of snow depth using optical image is conducted by using correlation with Snow Cover Fraction (SCF). Various algorithms have been proposed for the estimation of snow cover fraction based on Normalized Difference Snow Index (NDSI). In this study we tested linear, quadratic, and exponential equations for the generation of snow cover fraction maps using data from the Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua satellite in order to evaluate their applicability to the complex terrain of South Korea and to search for improvements to the estimation of snow depth on this landscape. The results were validated by comparison with in-situ snowfall data from weather stations, with Root Mean Square Error (RMSE) calculated as 3.43, 2.37, and 3.99 cm for the linear, quadratic, and exponential approaches, respectively. Although quadratic results showed the best RMSE, this was due to the limitations of the data used in the study; there are few number of in-situ data recorded on the station at the time of image acquisition and even the data is mostly recorded on low snowfall. So, we conclude that linear-based algorithms are better suited for use in South Korea. However, in the case of using the linear equation, the SCF with a negative value can be calculated, so it should be corrected. Since the coefficients of the equation are not optimized for this area, further regression analysis is needed. In addition, if more variables such as Normalized Difference Vegetation Index (NDVI), land cover, etc. are considered, it could be possible that estimation of national-scale snow depth with higher accuracy.

비동기 W-CDMA 시스템을 위한 코드블럭 내의 코드위치변조를 이용한 고속 셀 탐색 알고리즘 (A Fast Cell Search Algorithm using Code Position Modulation within code block in Asynchronous W-CDMA System)

  • 최정현;김낙명
    • 한국통신학회논문지
    • /
    • 제25권5A호
    • /
    • pp.611-617
    • /
    • 2000
  • 비동기 방식 W-CDMA 시스템은 동기식 방식보다 복합적인 셀 구조를 갖는 차세대 이동통신 시스템에 적합하다는 장점이 있다. 그러나, 이 경우 각 기지국마다 서로 다른 코드를 부여하기 때문에 단말기가 통화가능한 셀을 찾고 코드 동기를 이루는 데에 오랜 시간이 걸린다. 셀 획득의 지연은 통화 실패로 이어질 수 있으므로, 비동기 방식 W-CDMA 시스템을 구현하기 위해서는 고속 셀 탐색 알고리즘이 필수적인 기술이다. 본 논문에서는 도약 코드 시퀀스에 의하여 셀을 구분하고, 코드 블록 내의 이진코드이 위치를 도약코드를 사용하여 변화시킴으로써 기지국의 셀을 찾아내는 코드블럭 내의 코드 위치변조를 이용한 고속 셀 탐색 알고리즘을 제안한다. 제안된 방식은 기존의 방식에 비하여 보다 빠른 시간내에 셀을 찾을 수 있으며, 수신기도 더 간단하게 구현될 수 있다는 장점이 있다.

  • PDF

A Similarity Weight-based Method to Detect Damage Induced by a Tsunami

  • Jeon, Hyeong-Joo;Kim, Yong-Hyun;Kim, Yong-Il
    • 한국측량학회지
    • /
    • 제34권4호
    • /
    • pp.391-402
    • /
    • 2016
  • Among the various remote sensing sensors compared to the electro-optical sensors, SAR (Synthetic Aperture Radar) is very suitable for assessing damaged areas induced by disaster events owing to its all-weather day and night acquisition capability and sensitivity to geometric variables. The conventional CD (Change Detection) method that uses two-date data is typically used for mapping damage over extensive areas in a short time, but because data from only two dates are used, the information used in the conventional CD is limited. In this paper, we propose a novel CD method that is extended to use data consisting of two pre-disaster SAR data and one post-disaster SAR data. The proposed CD method detects changes by using a similarity weight image derived from the neighborhood information of a pixel in the data from the three dates. We conducted an experiment using three single polarization ALOS PALSAR (Advanced Land Observing Satellite/Phased Array Type L-Band) data collected over Miyagi, Japan which was seriously damaged by the 2011 east Japan tsunami. The results demonstrated that the mapping accuracy for damaged areas can be improved by about 26% with an increase of the g-mean compared to the conventional CD method. These improved results prove the performance of our proposed CD method and show that the proposed CD method is more suitable than the conventional CD method for detecting damaged areas induced by disaster.

Characterization and Zoonotic Potential of Uropathogenic Escherichia coli Isolated from Dogs

  • Nam, Eui-Hwa;Ko, Sungjin;Chae, Joon-Seok;Hwang, Cheol-Yong
    • Journal of Microbiology and Biotechnology
    • /
    • 제23권3호
    • /
    • pp.422-429
    • /
    • 2013
  • The aim of this study was to investigate the characteristics of canine uropathogenic Escherichia coli (UPEC) and the interaction between canine UPEC and human bladder epithelial cells. Ten E. coli isolates collected from dogs with cystitis were analyzed for antimicrobial resistance patterns, the presence of virulence factors, and biofilm formation. The ability of these isolates to induce cytotoxicity, invade human bladder epithelial cells, and stimulate an immune response was also determined. We observed a high rate of antimicrobial resistance among canine UPEC isolates. All virulence genes tested (including adhesins, iron acquisition, and protectin), except toxin genes, were detected among the canine UPEC isolates. We found that all isolates showed varying degrees of biofilm formation (mean, 0.26; range, 0.07 to 0.82), using a microtiter plate assay to evaluate biofilm formation by the isolates. Cytotoxicity to human bladder epithelial cells by the canine UPEC isolates increased in a time-dependent manner, with a 56.9% and 36.1% reduction in cell viability compared with the control at 6 and 9 h of incubation, respectively. We found that most canine UPEC isolates were able to invade human bladder epithelial cells. The interaction between these isolates and human bladder epithelial cells strongly induced the production of proinflammatory cytokines such as IL-6 and IL-8. We demonstrated that canine UPEC isolates can interact with human bladder epithelial cells, although the detailed mechanisms remain unknown. The results suggest that canine UPEC isolates, rather than dogspecific pathogens, have zoonotic potential.

Reproducibility of lateral cephalometric landmarks on conventional radiographs and spatial frequency-processed digital images

  • Shin Jeong-Won;Choi Hang-Moon;Heo Min-Suk;Lee Sam-Sun;Choi Hyun-Bae;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제32권4호
    • /
    • pp.213-219
    • /
    • 2002
  • Purpose : Computed radiography (CR) has been used in cephalometric radiography and many studies have been carried out to improve image quality using various digital enhancement and filtering techniques, During CR image acquisition, the frequency rank and type affect to the image quality. The aim of this study was to compare the diagnostic quality of conventional cephalometric radiographs to those of computed radiography. Materials and Methods : The diagnostic quality of conventional cephalometric radiographs (MO) and their digital image counterparts were compared, and at the same time, six modalities (M1-M6) of spatial frequency-processed digital images were compared by evaluating the reproducibility of 23 cephalometric landmark locations. Reproducibility was defined as an observer's deviation (in mm) from the mean between all observers. Results and Conclusion: In comparison with the conventional cephalometric radiograph (MO), Ml showed statistically significant differences in 8 locations, M2 in 9, M3 12, M4 in 7, M5 in 12, and M6 showed significant differences in 14 of 23 landmark locations (p < 0.05). The number of reproducible landmarks that each modality possesses were 7 in M6, 6 in M5, 5 in M3, 4 in M4, 3 in M2, 2 in Ml, and 1 location in MO. The image modality that observers selected as having the best image quality was M5.

  • PDF

정사각단면 $180^{\circ}C$ 곡덕트에서 층류진동유동의 유동 특성에 관한 연구 (A study on flow characteristics of laminar oscillatory flows in a square-sectional $180^{\circ}C$ curved duct)

  • 박길문;조병기;봉태근
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.139-152
    • /
    • 1998
  • In the present study, the flow characteristics of developing laminar oscillatory flows in a square -sectional 180 deg. curved duct are investigated experimentally. The experimental study using air in a square-sectional 180 deg. curved duct is carried out to measure velocity distributions with a data acquisition and LDV (Laser Doppler Velocimetry) processing system. In this system, Rotating Machinery Resolver (RMR) and PHASE program are used to obtain the results of unsteady flows. The major flow characteristics of developing oscillatory flows are found by analyzing velocity curves, mean velocity profiles, time-averaged velocity distribution of secondary flow, wall shear stress distributions, and entrance lengths. In a lower dimensionless angular frequency, the axial velocity distribution of laminar oscillatory flow in a curved duct shows a convex shape in a central part and axial symmetry. The maximum value of wall shear stress in a lower dimensionless angular frequency is located in an outside wall, but according to increasing the dimensionless angular frequency, the maximum of wall shear stress is moved to inner wall. The entrance lengths of laminar oscillatory flows in a square-sectional 180 deg. curved duct is obtained to 90 deg. of bended angle of duct in this experimental conditions.