• 제목/요약/키워드: maximum ratio combining

검색결과 114건 처리시간 0.029초

평면식 건조기의 적정작업조건 설정에 관한 연구 (Study on The Qptimization of Operating Conditions of batch-type Grain Dryer)

  • 박경규;정창주
    • 한국농공학회지
    • /
    • 제16권4호
    • /
    • pp.3600-3610
    • /
    • 1974
  • Experimental work of batch-type dryer was conducted to develop its optimurm operating conditions by analyzing the major factors which affect the drying performance. A laboratory batch-type dryer was constructed and tested for various levels of heated-air rates, and depths of grain deposit. Tong-il rice variety having the initial moisture content of approximaely 23 per cent in wet basis was used for the experiment. The criteria selected for establishing the optimum operating condition were the drying performance rate, the thermal efficiency, and the operational cost of the dryer. The results of the study are summarized as follows: 1. The performance rate of dryer for a specific operating condition was defined as total amount of material dried per hour when the moisture content of grains in the upperlayer reaches to 16 per cent in wet basis. The optimum operating conditions as viewed in the rate of drying performance could be justified by functional realtionship between the depth of grain deposit and air flow rate. In other words, there was a definite depth of grain deposit for a given air-rate which make the dryer performance maximum. The optimum grain depth for the batch-type dryer with 3.3㎡ loading area and with the attached axial fan was about 35cm. 2. The thermal efficiency for the dryer was evaluated by the ratio of the latent heat required to evaporate the grain moisture to the heat input required to raise the ambient air-temperature to 40 degree centigrade. The optimum operating condition as viewed in term of thermal efficiency analyzed was that grater depth and lower air flow-rate may be desirable. This condition is contracted with the optimum condition as viewed by the dryer performance rate. 3. The annual operating cost of batch-type dryer was analyzed for different annual hour of use and for different operation condition. The optimum condition as viewed in terms of operating cost was almost identical to one as viewed in terms of dryer performance rate. Therefore, the most economical use of batch-type dryer for the same annual operating hours can be obtained when the dryer operated in the condition of maximum dryer performance rate. Increasing the annual operating hour may be desirable to cut down the dryer operation cost, since the annual hour of dryer use is much sensitive to the operating cost than any peractical conditions of dryer operation. 4. The most desirable operational condition as justified by combining all the criteria, dryer performance rate, thermal efficiency and annual operating cost, could be concluded to operate the dryer in the condition of maximum performance rate. The condition in general is identical to the lowest operation cost for a given annual operating hour.

  • PDF

최대비 합성법을 이용한 SISO/MIMO-OFDM 기반 전력선 통신 방식 구현 및 성능분석 (Implementation and Performance Analysis of PLC Scheme based on SISO/MIMO-OFDM using MRC)

  • 유정화;최상호
    • 한국통신학회논문지
    • /
    • 제36권2B호
    • /
    • pp.176-183
    • /
    • 2011
  • 본 논문은 스마트 그리드를 비롯한 각종 미래 전력망 내 고속 데이터 전송을 타깃으로 한 SISO/MIMO-OFDM 기반 전력선통신 (PLC: power line communication) 방식의 구현 및 성능분석에 목적이 있다. 전력선통신 환경은 유선임에도 무선과 같은 다중경로 페이딩, 임펄스 잡음 등 매우 열악한 채널 특성을 갖는다. 다중경로 전력선 페이딩 채널은 Zimmermann 주파수 모델을 이용하며 임펄스 잡음 채널은 Middleton class A 모델을 이용한다. 본 논문에서는 주파수 선택적 다중경로 페이딩 특성을 갖는 전력선 채널 조건하에 공간 다이버시티 이득을 부가한 공간주파수 부호화 SISO/MIMO-OFDM 방식을 고려한다. 특별히 다중 안테나 경로와 다중 경로 페이딩의 다이버시티 이득을 효과적으로 결합한 최대비 합성 방식인 a&f-MRC를 이용한 기존 삼상 혹은 단상 PLC 시스템의 성능 개선 방안을 제시한다. 시뮬레이션을 통해 기존의 SISO/MIMO-OFDM 방식에 비한 성능우위를 입증하며 등비 합성법, 선택적 합성법과의 복잡도 대비 성능 비교로 시스템 설계상의 트레이드오프를 또한 제시한다. 임펄스 잡음지수 등 실제 PLC 채널 조건하에 체계적인 성능분석 및 시뮬레이션을 통해 적정 시스템 설계 파라미터를 도출한다.

몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석 (Optimum Design and Tolerance Analysis of Multilayer Mirror for Obtaining Characteristic X-ray of 17.5 keV)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제3권4호
    • /
    • pp.23-28
    • /
    • 2009
  • 단색 엑스선은 적은 방사선 피폭으로 대조도가 높은 의료영상을 만들 수 있다. 엑스선 튜브와 다층박막 거울을 결합하면 높은 플루언스의 단색 엑스선을 얻을 수 있다. 몰리브덴(Mo) 타깃을 갖는 엑스선 튜브에서 Mo 특성방사선(17.5keV)을 높은 반사율로 획득하기 위한 W/C 다층박막 거울의 최적화를 수행하였다. 반사율이 최대가 되는 조건에서 두께주기와 두께비를 결정하였다. 최적 설계된 다층박막 거울에 대한 두께주기와 브래그 정렬에 대한 공차를 구하였다. 증착(deposition) 공차 0.2nm와 회전정렬 공차 ${\pm}0.01^{\circ}$에서 이론 반사율의 85% 이상에 해당하는 반사율이 얻어질 수 있다. 다층박막 거울을 이용하면 높은 플루언스의 특성방사선을 얻어 낼 수 있기 때문에 의료영상 획득 장치에 많이 사용될 것이다.

  • PDF

다중 중계기 환경에 대한 에너지 하베스팅의 적용 방안 (Applied Method of Energy Harvesting for Multi-Relay Environment)

  • 김태욱;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.69-74
    • /
    • 2014
  • 본 논문에서는 협력 통신의 다중 중계기 모델에 에너지 하베스팅 기법을 적용하여 수신단에서 다이버시티 이득을 극대화함과 동시에 중계기의 전력 낭비를 줄일 수 있는 방안을 제안하였다. 송신단은 에너지 하베스팅 기법이 적용된 다중 중계기 중 가장 우수한 중계기를 선택해 메시지를 전송하게 되며 나머지 중계기는 전력으로 변환하여 저장하게 된다. 또한 기존에 선택된 중계기의 전력량이 일정 수준 이하일 경우 차선의 중계기를 선택해 전송을 유지함으로서 수신단의 다이버시티 이득을 유지할 수 있다. 따라서 제안하는 프로토콜을 일반적인 네트워크에 적용할 경우 중계기의 잔여 전력량에 따라 중계기의 교체가 지속적으로 이루어지게 되어 네트워크의 활용도 및 효율성을 증가시킬 수 있다. 마지막으로, 제안한 프로토콜을 레일리 페이딩 환경에서 전력 수집 효율 및 중계기 활용률, 비트 오류율(Bit Error Rate)을 통해 시스템의 성능을 평가한다.

기회주의적인 중계기 사용에 대한 협력 다이버시티의 성능 분석 (Performance Analysis of Cooperative Diversity on the Usage of Opportunistic Relay)

  • 김태욱;공형윤
    • 한국인터넷방송통신학회논문지
    • /
    • 제14권3호
    • /
    • pp.7-12
    • /
    • 2014
  • 협력통신을 실제 무선 통신 시스템에 적용하기 위해서는 정보 전달을 담당하는 중계기를 설치해야한다. 그러나 중계기 설치는 비용 및 전력 낭비의 문제점을 가지고 있다. 따라서, 본 논문에서는 일반적인 중계기의 사용을 재고하여, 효율적인 중계기 사용을 위해 중계기를 사용자 모바일 단말기로 정의하였다. 제안하는 프로토콜에 따라 중계기(사용자 단말기)의 상태에 대해 유휴, 무휴상태로 나누었으며, 수신단에 대해 기지국 모델, 사용자 단말기 모델을 적용하였다. 이 경우, 추가적인 비용 없이 실제 네트워크에 협력 통신을 적용할 수 있으며, 네트워크 용량 및 스펙트럼 효율을 높일 수 있다. 마지막으로, 제안한 프로토콜을 레일리 페이딩 환경에서 Monte-Carlo 시뮬레이션을 통해 전체적인 시스템 모델의 비트오류율(BER)을 분석한다.

영농형 태양광 시설 하부의 미기상 관측 자료: 보성에서 2019년 11월부터 2020년 5월까지 가을보리 재배기간 동안 (Meteorological Data Measured under Agrivoltaic Systems in Boseong-gun during Winter Barley Season)

  • 조유나;윤창용;김현기;문현동;안규남;조재일
    • 한국농림기상학회지
    • /
    • 제22권3호
    • /
    • pp.144-151
    • /
    • 2020
  • 작물을 재배하는 동시에 전력 생산도 가능한 영농형 태양광 발전은 농업·농촌 분야와 재생에너지 산업 모두로부터 주목 받고 있다. 하지만, 그 역사가 짧은 만큼 영농형 태양광 하부에서의 미기상 환경 변화에 대한 이해와 관측 방법론이 정립되지 않은 실정이다. 따라서 본고에서는 보성군에 설치된 영농형 태양광에서 2019년 11월 부터 2020년 5월까지의 보리 생육기간 동안 일사광, 광합성유효복사광, 기온, 습도, 토양습도·온도, 풍향·풍속을 5분 간격으로 측정하여 공개했다. 또한, 노지의 일사량 및 광합성유효복사량에 대한 약 13일 간의 자료 결손에 대해서는 가까운 기상청 관측 자료를 활용하거나 영농형 태양광 하부의 자료를 이용한 두 가지 경험적 메우기 방법을 제안하였다. 본고 자료가 영농형 태양광에 대한 농업적 평가에 다양하게 활용되기를 기대한다.

Identification of bacteria isolated from rockworm viscera and application of isolated bacteria to shrimp aquaculture wastewater treatment

  • Ja Young Cho;Kyoung Sook Cho;Chang Hoon Kim;Joong Kyun Kim
    • 환경생물
    • /
    • 제41권2호
    • /
    • pp.167-178
    • /
    • 2023
  • Large amounts of waste and wastewater from aquaculture have negatively impacted ecosystems. Among them, shrimp aquaculture wastewater contains large amounts of nitrogen contaminants derived from feed residues in an aerobic environment. This study isolated candidate strains from adult rockworms to treat shrimp aquaculture wastewater (SAW) in an aerobic environment. Among 87 strains isolated, 25 grew well at the same temperature as the shrimp aquaculture with excellent polymer degradation ability (>0.5 cm clear zone). Six isolates (strains AL1, AL4, AL5, AL6, LA10, and PR15) were finally selected after combining strains with excellent polymer degradation ability without antagonism. 16S rRNA sequencing analysis revealed that strains AL1, AL4, AL5, AL6, LA10, and PR15 were closely related to Bacillus paramycoides, Bacillus pumilus, Stenotrophomonas rhizophila, Bacillus paranthracis, Bacillus paranthracis, and Micrococcus luteus, respectively. When these six isolates were applied to SAW, they reached a maximum cell viability of 2.06×105 CFU mL-1. Their chemical oxygen demand (CODCr) and total nitrogen(TN) removal rates for 12h were 51.0% and 44.6%, respectively, when the CODCr/TN ratio was approximately 10.0. Considering these removal rates achieved in this study under batch conditions, these six isolates could be used for aerobic denitrification. Consequently, these six isolates from rockworms are good candidates that can be applied to the field of aquaculture wastewater treatment.

Whole-life wind-induced deflection of insulating glass units

  • Zhiyuan Wang;Junjin Liu;Jianhui Li;Suwen Chen
    • Wind and Structures
    • /
    • 제37권4호
    • /
    • pp.289-302
    • /
    • 2023
  • Insulating glass units (IGUs) have been widely used in buildings in recent years due to their superior thermal insulation performance. However, because of the panel reciprocating motion and fatigue deterioration of sealants under long-term wind loads, many IGUs have the problem of early failure of watertight properties in real usage. This study aimed to propose a statistical method for wind-induced deflection of IGU panels during the whole life service period, for further precise analysis of the accumulated fatigue damage at the sealed part of the edge bond. By the estimation of the wind occurrence regularity based on wind pressure return period, the events of each wind speed interval during the whole life were obtained for the IGUs at 50m height in Beijing, which are in good agreement with the measured data. Also, the wind-induced deflection analysis method of IGUs based on the formula of airspace coefficient was proposed and verified as an improvement of the original stiffness distribution method with the average relative error compared to the test being about 3% or less. Combining the two methods above, the deformation of the outer and inner panes under wind loads during 30 years was precisely calculated, and the deflection and stress state at selected locations were obtained finally. The results show that the compression displacement at the secondary sealant under the maximum wind pressure is close to 0.3mm (strain 2.5%), and the IGUs are in tens of thousands of times the low amplitude tensile-compression cycle and several times to dozens of times the relatively high amplitude tensile-compression cycle environment. The approach proposed in this paper provides a basis for subsequent studies on the durability of IGUs and the wind-resistant behaviors of curtain wall structures.

임펄스 잡음과 나카가미 페이딩이 존재할 때 다이버시티 기법과 오류정정 부호를 이용한 무선통신 DS/CDMA 시스템의 오율 특성 (Performance of Radio Communication DS/CDMA System with Diversity Technique and BCH Coding under Impulsive Noise and Nakagami Fading)

  • 김지웅;강희조;이권현
    • 한국전자파학회논문지
    • /
    • 제10권4호
    • /
    • pp.539-549
    • /
    • 1999
  • 본 논문에서는 다중접속간섭. 임펼스 잡음과 나카가미 페이딩 환경에서 DS/CDMA DQPSK 통선시스댐의 B BER 성능을 분석하였다. 고려되는 DS/CDMA DQPSK 통신시스템은 제안한 시스템의 성능을 향상시키기 위하여 최대비 합성(MRC) 다이버시티 수신기법과 오류 정정 BCH 부호화 기법을 채용하였다. 유도한 오율 식을 이용하여 DS/CDMA DQPSK 통신시스댐의 성능을 구하여, 임펄스 지수( A), 가우시안 잡음 전력 대 임펄스 잡음 전력비($\Gamma'$), 다중접속간섭(K), 나카가미 페이딩 파라미터(m), MRC 다이버시티 가지수 (L), 부호의 오류 정정 능력(f), 직접확산 처리 이득(N)과 선호 전력 대 잡음 전력비( $E_b/N_O$)을 함수 로 하여 오율 그래프로 나타내고 분석하였다. 분석한 결과, 제안하는 시스댐의 성능은 무선통신시스댐환경에 서 다중접속간섭, 임펼스 잡음과 나카가미 페이멍에 의해 영향을 받을 수 있다. 또한 희망하는 선호의 전력이 나 임펄스 지수, 가우시안 잡음 천력 대 임펼스 잡음 전력비를 증가시켜 DS/CDMA DQPSK 통신시스댐의 BER 성능을 개선할 수 있음을 알 수 있었다. 그리고 다중접속간섭, 임펄스 잡음과 나카가미 페이딩의 영 향을 억압하기 위해서는 MRC 다이버시티 수산된 DS/CDMA DQPSK 통신시스댐보다는 BCH05.7) 부호화 기법을 적용한 DS/CDMA DQPSK 시스댐이 효율적임을 알 수 있었다.

  • PDF

CT Based 3-Dimensional Treatment Planning of Intracavitary Brachytherapy for Cancer of the Cervix : Comparison between Dose-Volume Histograms and ICRU Point Doses to the Rectum and Bladder

  • Hashim, Natasha;Jamalludin, Zulaikha;Ung, Ngie Min;Ho, Gwo Fuang;Malik, Rozita Abdul;Ee Phua, Vincent Chee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권13호
    • /
    • pp.5259-5264
    • /
    • 2014
  • Background: CT based brachytherapy allows 3-dimensional (3D) assessment of organs at risk (OAR) doses with dose volume histograms (DVHs). The purpose of this study was to compare computed tomography (CT) based volumetric calculations and International Commission on Radiation Units and Measurements (ICRU) reference-point estimates of radiation doses to the bladder and rectum in patients with carcinoma of the cervix treated with high-dose-rate (HDR) intracavitary brachytherapy (ICBT). Materials and Methods: Between March 2011 and May 2012, 20 patients were treated with 55 fractions of brachytherapy using tandem and ovoids and underwent post-implant CT scans. The external beam radiotherapy (EBRT) dose was 48.6Gy in 27 fractions. HDR brachytherapy was delivered to a dose of 21 Gy in three fractions. The ICRU bladder and rectum point doses along with 4 additional rectal points were recorded. The maximum dose ($D_{Max}$) to rectum was the highest recorded dose at one of these five points. Using the HDRplus 2.6 brachyhtherapy treatment planning system, the bladder and rectum were retrospectively contoured on the 55 CT datasets. The DVHs for rectum and bladder were calculated and the minimum doses to the highest irradiated 2cc area of rectum and bladder were recorded ($D_{2cc}$) for all individual fractions. The mean $D_{2cc}$ of rectum was compared to the means of ICRU rectal point and rectal $D_{Max}$ using the Student's t-test. The mean $D_{2cc}$ of bladder was compared with the mean ICRU bladder point using the same statistical test. The total dose, combining EBRT and HDR brachytherapy, were biologically normalized to the conventional 2 Gy/fraction using the linear-quadratic model. (${\alpha}/{\beta}$ value of 10 Gy for target, 3 Gy for organs at risk). Results: The total prescribed dose was $77.5Gy{\alpha}/{\beta}10$. The mean dose to the rectum was $4.58{\pm}1.22Gy$ for $D_{2cc}$, $3.76{\pm}0.65Gy$ at $D_{ICRU}$ and $4.75{\pm}1.01Gy$ at $D_{Max}$. The mean rectal $D_{2cc}$ dose differed significantly from the mean dose calculated at the ICRU reference point (p<0.005); the mean difference was 0.82 Gy (0.48-1.19Gy). The mean EQD2 was $68.52{\pm}7.24Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$, $61.71{\pm}2.77Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$ and $69.24{\pm}6.02Gy_{{\alpha}/{\beta}3}$ at $D_{Max}$. The mean ratio of $D_{2cc}$ rectum to $D_{ICRU}$ rectum was 1.25 and the mean ratio of $D_{2cc}$ rectum to $D_{Max}$ rectum was 0.98 for all individual fractions. The mean dose to the bladder was $6.00{\pm}1.90Gy$ for $D_{2cc}$ and $5.10{\pm}2.03Gy$ at $D_{ICRU}$. However, the mean $D_{2cc}$ dose did not differ significantly from the mean dose calculated at the ICRU reference point (p=0.307); the mean difference was 0.90 Gy (0.49-1.25Gy). The mean EQD2 was $81.85{\pm}13.03Gy_{{\alpha}/{\beta}3}$ for $D_{2cc}$ and $74.11{\pm}19.39Gy_{{\alpha}/{\beta}3}$ at $D_{ICRU}$. The mean ratio of $D_{2cc}$ bladder to $D_{ICRU}$ bladder was 1.24. In the majority of applications, the maximum dose point was not the ICRU point. On average, the rectum received 77% and bladder received 92% of the prescribed dose. Conclusions: OARs doses assessed by DVH criteria were higher than ICRU point doses. Our data suggest that the estimated dose to the ICRU bladder point may be a reasonable surrogate for the $D_{2cc}$ and rectal $D_{Max}$ for $D_{2cc}$. However, the dose to the ICRU rectal point does not appear to be a reasonable surrogate for the $D_{2cc}$.