Analysis of Safety Distance and Maximum Permissible Power of Resonant Wireless Power Transfer Systems with Regard to Magnetic Field Exposure

  • Park, Young-Min;Byun, Jin-Kyu
    • Journal of Magnetics
    • /
    • 제20권4호
    • /
    • pp.450-459
    • /
    • 2015
  • In this paper, the safety distances and maximum permissible power (MPP) of resonant wireless power transfer systems are defined and derived with regard to human exposure to electromagnetic field (EMF). The definition is based on the calculated induced current density and electric field in the standard human model located between the transmitting and receiving coil. In order to avoid the adverse health effects such as stimulation of nerve tissues, the induced current and electric field must not exceed the basic restriction values specified in EMF safety guidelines. The different combinations of diameters of the coils and the distance between the two coils are investigated and their effects are analyzed. Two versions of EMF safety guidelines (ICNIRP 1998 and ICNIRP 2010) are used as bases for safety distance calculation and the difference between the two guidelines are discussed.

154kV XLPE 600㎟ 지중관로 수평배열 형태별 허용전류용량 산정에 관한 연구 (A Study on the Calculation of Transmission Current-Carrying Capacity by Horizontal Arrangement Type in the Installation Methods of 154kV XLPE 600㎟ Power Cable Buried Ducts in Ground)

  • 김세동;유상봉
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.53-58
    • /
    • 2016
  • The underground transmission lines which have been built to expand the suppling facilities will be continuously accompanying with high growth of the increase of power demand in the metropolitan area in recent years. So, it is necessary to maximize the ability and reliability of power supply with the current-carrying capability of the underground transmission lines. Design criteria of KEPCO is to be presented and used frequently. But it has to be studied about the installation methods of power cable buried in ground. In this study, we used the program for calculating the current-carrying capability of underground transmission power cables. We estimated the maximum permissible current values by the horizontal arrangement in the installation methods of power cable(154kV XLPE $600mm^2$) buried ducts in ground. To see the general tendency of the analysis, we researched a statistical analysis with such parameters as the maximum permissible current values. Through the regression analysis, we analyze the most highly values of the maximum permissible current on the Ra type duct arrangement.

국내 저압 전기기기의 고조파 유출 제한값 산정 (Calculation of the Harmonic Emission Limit for low-Voltage Electrical Equipment)

  • 강문호;송양회;이흥호
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.56-61
    • /
    • 2008
  • 배전계통의 고조파 방해(Harmonics Disturbance)현상은 배전계통에서 전압강하와 함께 순시 전력품질을 저해하여 중성선 및 NGR(Neutral Ground Reactor) 과열, OCGR 오동작 등의 문제를 발생시킴으로써 전력회사와 고객 모두에게 막대한 경제적인 손실을 주고 있어 동 분야에 대한 적극적인 대책이 필요하다. 이에 대한 해결 방안으로 유럽에서는 IEC 61000-3-2 규격을 통해 상당 16[A] 이하 저압 전기기기의 고조파를 제한하고 있다. 본 규격은 저압 전기기기를 4개의 등급으로 구분하여 관리하고 있으며, 분석결과 클래스 A등급 해당 전기기기의 고조파 유출제한 기준은 저압계통의 기준임피던스와 허용 최대전압을 바탕으로 산정되었으며, 타 등급(B, C, D등급)의 유출제한 기준들도 클래스 A의 유출제한 기준을 바탕으로 산정되었다. 따라서 본 논문에서는 IEC 61000-3-2 규격 분석결과를 바탕으로 국내 기준임피던스에 기초하여 국내 저압 전기기기의 고조파 유출 제한 값을 산정하였다.

전자파에 노출된 생체의 전기 생리적 변화의 측정 (Measurement of Electrophysiological Changes Caused by Electromagnetic Radiation Absorbed in Biobody)

  • Ju-Tae Park
    • 한국전자파학회논문지
    • /
    • 제7권4호
    • /
    • pp.353-362
    • /
    • 1996
  • 본 논문에서는 토끼를 대상으로 하여 그 두부에 전자파가 조사(照射)된 경우에 대해 토끼 두부를 3충 구모델로 근사해서 SAR분포를 계산하였다. 계산 결과를 확인하기 위해 주파수 2,450MHz인 마이크로파를 출력세기별로 5그룹으로 설정하여 각각에 대한 노출 전 후의 EEG를 전두부(前頭部)에서 측정하였다. 실험에서 전자파 조사 후에는 뇌전위의 전체평균값은 조금 감소히였고, 특히 $\theta$, $\delta$그리고 $\beta$파의 평균합성비율은 증가하였다. 이 결과는 마이크로파 조사후 전기적 생리활동의 감소와 뇌파의 속파화 경향을 나타낸다. 측정된 뇌전위로써 생체에 대한 전기 생리적 효과를 정량적으로 파악하여 최대허용노출(Maximum Permissible Exm posure)의 객관적인 추정을 하였다.

  • PDF

농축인자법에 의한 유도방출 기준 설정 (Determination of Derived Release Limits by the Concentration Factor Method)

  • Byung Woo Kim;Byeung Kyu Kim;Jeong Ho Lee
    • Nuclear Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.267-278
    • /
    • 1985
  • 원자력발전소로부터 배출되는 방사성물질에 의한 피폭선량을 규제하는데 있어 몇 가지 종류들의 방식들이 적용되어 왔다. ICRP에 의해 권고된 일차 선량 당량 제한치가 가장 근본적인 것이다. 일차 제한치가 직접 적용될 수 없을 때 외부 피폭의 경우 선량당량 지표가 내부피폭의 경우 최대허용농도, 연섭취 제한치 흑은 유도대기 농도 및 최대 신체 부하량 등이 이용되어 왔다. 그러나 이 값들은 실제 배출량을 제어하는 견지에서 바로 사용할 수 없어 유도방출 기준치를 구하게 된다. 본 연구에선 월성 원자력발전소에 대해 고려되는 특정환경들 사이의 전달속도가 시간에 독립적인, 장기성 농축인자 방식으로 방출속도의 유도 제한치를 구하였다.

  • PDF

국산 핀애자의 라디오 방해 전압(RIV) 평가 (Evaluation on the radio influence voltage of ${7^1/2}$ pin type domestic insulators)

  • 양배덕
    • 전기의세계
    • /
    • 제25권6호
    • /
    • pp.65-68
    • /
    • 1976
  • For the RIV characteristics test of power apparatus, an indoor measuring system of radio influence voltage was set up and by means of this measuring unit SIV characteristics on the 7$^{1}$2/" pin-type domestic insulators were examined. According to the test data, RIV values of all the test pieces exceeded the maximum permissible level at 10kV applied voltage. The electrical resistivity of domestic semi-conductive glaze as good as importedone but un-uniformity of coating is turned out to be a main cause of failure.lure.

  • PDF

System-Level Vulnerability Analysis for Commutation Failure Mitigation in Multi-infeed HVDC Systems

  • Yoon, Minhan;Jang, Gilsoo
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1052-1059
    • /
    • 2018
  • This paper deals with commutation failure of the line-commutated converter high voltage direct current (LCC HVDC) system caused by a three phase fault in the ac power system. An analytic calculation method is proposed to estimate the maximum permissible voltage drop at the LCC HVDC station on various operating point and to assess the area of vulnerability for commutation failure (AOV-CF) in the power system based on the residual phase voltage equation. The concept is extended to multi-infeed HVDC power system as the area of severity for simultaneous commutation failure (AOS-CF). In addition, this paper presents the implementation of a shunt compensator applying to the proposed method. An analysis and simulation have been performed with the IEEE 57 bus sample power system and the Jeju island power system in Korea.

가스터빈 제어 루프에 대한 신경망 튜닝 루프 보상형 2-자유도 PID 제어기의 응용 (Application a Loop Compensation type 2-DOF PID Controller tuned by Neural Network to Gas Turbine Control Loop)

  • 김동화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.781-786
    • /
    • 1998
  • Since a gas turbine is still a significant contributor to peak time, it is very important to tune the gains of P. I. D to get a maximum power and stability within permissible limits. In the gas turbine, the main control loop must adjust the fuel flow to ensure the correct output power and frequency. but it is not easy, because the control loop is composed of many subsystems. In this paper we acquire a transfer function based on the operations data of Gun-san gas turbine and study to apply a loop compensation type 2-DOF PID controller tuning by neural-network to control loop of gas turbine to reduce phenomena caused by integral and derivative actions through simulation. We obtained satisfactory results to disturbances of subcontrol loop such as, fuel flow, air flow, turbine extraction temperature.

  • PDF

DSP에 의한 약계자영역 영구자석 동기전동기의 개선된 운전특 (Improved driving characteristics of PMSM with field-weakening region based on DSP)

  • Yoon, Byung-Do;Lee, Byung-Song;Kim, Choon-Sam
    • 대한전기학회논문지
    • /
    • 제45권1호
    • /
    • pp.74-80
    • /
    • 1996
  • This paper describes current controlled PWM technique of PM synchronous motors for a wide variety of speed control applications. They are however limited in their ability to operate in the power limited regime where the available torque is reduced as the speed is increased above its base value. This paper reviews the operation of the PMSM drives when they are constrained to be within the permissible envelope of maximum inverter voltage and current to produce the rated power and to provide this with the highest attainable rotor speed. The optimal field-weakening control algorithm is the use of phase current and d-axis current feedback to reduce of error between the d-axis current command and real current and to improve the torque characteristics. The improved torque characteristics of speed control strategy with optimal field weakening control algorithm is analyzed and the performance is investigated by the computer simulation and experimental results. (author). refs., figs.

  • PDF

전류궤환에 의한 영구자석 동기 전동기의 약계자 제어 (Field Weakening Control of IPMSM Using Current Feedback)

  • 윤병도;김윤호;김종구;최원범;이병송
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 A
    • /
    • pp.347-349
    • /
    • 1995
  • This paper describes current controlled PWM technique of IPM synchronous motors for a wide variety of speed control applications. They are however limited in their ability to operate in the power limited regime where the available torque is reduced as the speed is increased above its base value. This paper reviews the operation of the IPMSM drives when they are constrained to be within the permissible envelope of maximum inverter voltage and current to produce the rated power and to provide this with the highest attainable rotor speed. This paper proposes a new field-weakening control algorithm using phase current feedback to improve the torque characteristics and to reduce the torque ripple of IPMSM in the constant power region. The improved torque characteristics of speed control strategy with current feedback control algorithm is analyzed and the performance is investigated by the computer simulation results.

  • PDF