• Title/Summary/Keyword: maximal reliability

Search Result 38, Processing Time 0.019 seconds

LLR-based Cooperative ARQ Protocol in Rayleigh Fading Channel (레일리 페이딩 채널에서 LLR 기반의 협력 ARQ 프로토콜)

  • Choi, Dae-Kyu;Kong, Hyung-Yun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.4
    • /
    • pp.31-37
    • /
    • 2008
  • Conventional cooperative communications can attain gain of spatial diversity and path loss reduction because destination node independently received same signal from source node and relay node located between source node and destination node. However, these techniques bring about decreased spectral efficiency with relay node and increased complexity of receiver by using maximal ratio combining (MRC). This paper has proposed cooperative ARQ protocol that can improve the above problems and can get the better performance. This method can increase the spectral efficiency than conventional cooperative communication because if the received signal from source node is satisfied by the destination preferentially, the destination transmits ACK message to both relay node and source node and then recovers the received signal. In addition, if ARQ message indicates NACK relay node operates selective retransmission and we can increase reliability of system compared with that of general ARQ protocol in which source node retransmits data. In the proposed protocol, the selective retransmission and ARQ message are to be determined by comparing log-likelihood ratio (LLR) computation of received signal from source node with predetermined threshold values. Therefore, this protocol don't waste redundant bandwidth with CRC code and can reduce complexity of receiver without MRC. We verified spectral efficiency and BER performance for the proposed protocol through Monte-Carlo simulation over Rayleigh fading plus AWGN.

The Effect of Head Posture Change on Initial Occlusal Contacts (두부의 자세 변화가 초기 교합접촉에 미치는 영향)

  • Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.1
    • /
    • pp.195-204
    • /
    • 1995
  • The purpose of this study was to evaluate effect of head posture change on initial occlusal contacts through measuring the distances between initial occlusal contacts and maximum intercuspal position at different head posture. Two special devices were designed and constructed. Mandibular movement replicator was used to assess reliability of the K6 diagnostic system(MKG; Myo-tronic Inc, Seatle, USA) and head posture calibrator was used to maintain the constant head posture during experiment. We measured difference of distance between initial occlusal contact and maximum intercuspal position with MKG in upright, supine, 45 degrees extension, 30 degrees flexion, 30 degrees right and left bending postion of the head. The Frankfurt horizontal plane was used as a reference plane. 21 adults aged from 23 to 25 were selected, who have normal or class I molar relationship, and have no symptoms on TMJ and masticatory muscles, and have restorations less than 3 surfaces on each tooth, and have no other prosthetic restoration. The obtained results were as follows : The mean absolute distances between initial occlusal contact and maximum intercuspal postion were 0.39(0.18mm in the upright position, 0.65(0.37mm in the supine position, 0.59(0.33mm in the 45 degree extension, 0.70(0.53mm in the 30 degrees flexion, 1.12(1.10mm in the 30 degrees right bending and 1.94(0.67mm in the 30 degrees left bending of the head. The positions of the initial occlusal contacts have a tendency to locate anterior, left and inferior to maximal intercuspal position in upright position, posterior and inferior in supine position and 45 degrees extension, anterior and inferior in 30 degrees flexion, right and inferior in 30 degrees right bending, and left and inferior in 30 degrees left bending of the head. There were significant differences among the initial occlusal contacts in each head postures(P<0.0001). Therefore, we need to check initial occlusal contacts in the altered head posture during occlusal analysis and adjustment of occlusal appliance and dental occlusion for diagnosis and treatment of temporomandibular disorder.

  • PDF

Object Recognition Method for Industrial Intelligent Robot (산업용 지능형 로봇의 물체 인식 방법)

  • Kim, Kye Kyung;Kang, Sang Seung;Kim, Joong Bae;Lee, Jae Yeon;Do, Hyun Min;Choi, Taeyong;Kyung, Jin Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.9
    • /
    • pp.901-908
    • /
    • 2013
  • The introduction of industrial intelligent robot using vision sensor has been interested in automated factory. 2D and 3D vision sensors have used to recognize object and to estimate object pose, which is for packaging parts onto a complete whole. But it is not trivial task due to illumination and various types of objects. Object image has distorted due to illumination that has caused low reliability in recognition. In this paper, recognition method of complex shape object has been proposed. An accurate object region has detected from combined binary image, which has achieved using DoG filter and local adaptive binarization. The object has recognized using neural network, which is trained with sub-divided object class according to object type and rotation angle. Predefined shape model of object and maximal slope have used to estimate the pose of object. The performance has evaluated on ETRI database and recognition rate of 96% has obtained.

Modeling and SINR Analysis of Dual Connectivity in Downlink Heterogeneous Cellular Networks

  • Wang, Xianling;Xiao, Min;Zhang, Hongyi;Song, Sida
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.11
    • /
    • pp.5301-5323
    • /
    • 2017
  • Small cell deployment offers a low-cost solution for the boosted traffic demand in heterogeneous cellular networks (HCNs). Besides improved spatial spectrum efficiency and energy efficiency, future HCNs are also featured with the trend of network architecture convergence and feasibility for flexible mobile applications. To achieve these goals, dual connectivity (DC) is playing a more and more important role to support control/user-plane splitting, which enables maintaining fixed control channel connections for reliability. In this paper, we develop a tractable framework for the downlink SINR analysis of DC assisted HCN. Based on stochastic geometry model, the data-control joint coverage probabilities under multi-frequency and single-frequency tiering are derived, which involve quick integrals and admit simple closed-forms in special cases. Monte Carlo simulations confirm the accuracy of the expressions. It is observed that the increase in mobility robustness of DC is at the price of control channel SINR degradation. This degradation severely worsens the joint coverage performance under single-frequency tiering, proving multi-frequency tiering a more feasible networking scheme to utilize the advantage of DC effectively. Moreover, the joint coverage probability can be maximized by adjusting the density ratio of small cell and macro cell eNBs under multi-frequency tiering, though changing cell association bias has little impact on the level of the maximal coverage performance.

The Development of Prediction Equation for Estimating VO2max from the 20 m PSRT in Korean Middle-School Girls. Exercise Science (20 m 점증 왕복달리기 검사를 이용한 여중생의 VO2max 추정식 개발)

  • Park, Dong-Ho;Song, Jung-Ran;Lee, Sang-Hyun;Kim, Chang-Sun
    • Exercise Science
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2014
  • The purpose of this study was to develop and validate regression models to estimate maximal oxygen uptake (VO2max) from the 20 m Progressive Shuttle Run Test (20 m PSRT) in Korean middle-school girls aged 13-15 years. The 20 m PSRT and VO2max were assessed in a sample of 194 participants. The sample was randomly split into validation (n=127) and test-retest reliability (n=99, 32 out of 127 participants also performed validity test) groups. 127 participants performed a graded exercise test (GXT, stationary gas analyser) and the 20 m PSRT (portable gas analyser) once to develop a VO2max prediction model and to analyze the validity of the modified 20 m PSRT protocol (starting at 7.5 km/h and increasing by 0.5 km/h every 1 min). 99 participants performed the 20 m PSRT twice for test-retest reliability purpose. Mean measured VO2max (39.2±5.1 ml/kg/min) from the potable gas analyzer was significantly increased from that measured during the GXT from stationary gas analyzer (37.7±5.7 ml/kg/min, p=.001) using the modified 20 m PSRT protocol. But it was a narrow range (1.5 ml/kg/min). The measured VO2max from the potable and stationary gas analyzers correlated at r=.88(p<.001). Test-retest of the 20 m PSRT yielded comparable results (Laps r=.88 & final speed r=.85). New regression equations were developed from present data to predict VO2max for middle-school girls: y=.231×Laps-.311×weight(in kg)+46.201 (r=.74, SEE=4.29 ml/kg/min). It is concluded that (a) the modified 20 m PSRT protocol is a valid and reliable test and (b) this equation developed in this study provides valid estimates of VO2max of Korean middle-school girl aged 13-15 years.

Change of fluorescence in ambers according to artificial aging (인공열화에 따른 호박(amber)의 형광특성 변화)

  • Park, Jong-Seo;Lim, Yu-Jin
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.197-206
    • /
    • 2012
  • Ambers are composed of polymer molecules which contain aromatic moieties such as benzene, naphthalene, phenanthrene and anthracene. They emit fluorescence when irradiated with ultraviolet light, which was used for confirming an amber. The fluorescence of amber, however, tends to decrease as the surface of amber is weathered with light, heat, oxygen for a long time. In this study, the reliability of confirming amber with its fluorescence by measuring the changes of fluorescence after artificial aging. Aging factors were UV light (${\lambda}$=340 nm), oxygen with heat (100%, $90^{\circ}C$) and heat ($90^{\circ}C$) and aging time was for 5, 15, 30 and 60 days, respectively. In the excitation and emission spectra of amber, the intensity decreased and the maximal wavelength was shifted to longer wavelength with artificial aging time. Especially, there was a drastic decrease in the intensity of spectra to 1.7% of initial value after 60 days aging under oxygen with heat. Only in Colombian amber there showed an increase of fluorescence intensity for a certain aging time, which could be explained by the production of aromatic ring in the presence of light and heat. Conclusively, the fluorescence can be lessened by the natural weathering with light, heat and oxygen and it is not accurate to recognize amber just with UV irradiation method.

A Study on Mice Exposure Dose for Low-dose Gamma-irradiation Using Glass Dosimeter (유리선량계를 이용한 저선량 방사선의 마우스 피폭선량 연구)

  • Noh, Sung Jin;Kim, Hyo Jin;Kim, Hyun;Jeong, Dong Hyeok;Son, Tae Gen;Kim, Jung Ki;Yang, Kwangmo;Nam, Sang-Hee;Kang, Yeong-Rok
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.202-210
    • /
    • 2015
  • The low dose radiation is done for a long period, thus researchers have to know the exact dose distribution for the irradiated mouse. This research has been conducted in order to find out methods in transmitting an exact dose to mouse in a mouse irradiation experiment carried out using $^{137}Cs$ irradiation equipment installed in the DIRAMS (Dongnam Institution of Radiological & Medical Sciences) research center. We developed a single mouse housing cage and shelf with adjustable geometric factors such as distance and angle from collimator. The measurement of irradiated dose showed a maximal 42% difference of absorbed dose from the desired dose in the conventional irradiation system, whereas only 6% difference of the absorbed dose was measured in the self-developed mouse apartment system. In addition, multi mice housing showed much difference of the absorbed dose in between head and body, compared to single mouse housing in the conventional irradiation system. This research may allow further research about biological effect assessment for the low dose irradiation using the self-developed mouse apartment to provide more exact doses which it tries to transmit, and to have more reliability for the biological analysis results.

Measurement of Ventilatory Threshold in the Patients with Chronic Airway Obstruction (만성기도폐쇄를 보이는 환자에서 환기성역치 측정)

  • Lee, Kye-Young;Jee, Young-Koo;Kim, Keun-Yeol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.2
    • /
    • pp.309-320
    • /
    • 1997
  • Background : There are many suggested methods for the indirect determination of anaerobic threshold(AT) using the changes of ventilatory parameters in response to ventilatory load accompanying the increase of blood lactic acid level during exercise and the threshold derived from them is called ventilatory threshold(VT). They include ventilatory equivalent method(VEM), End-tidal $PO_2$ method($PETO_2$). V-slope method(VSM), and respiratory quotient method(RQ). But in the patients with chronic airway obstruction(CAO), the AT determined by ventilatory methods may not reflect true AT because the patients with CAO show inadequate ventilatory response to the increase of blood lactic acid level during excercise. Methods : For the investigation of detection rate and reliability of above four VT determination methods in the patients with CAO, we performed the symptom-limited and maximal incremental exercise test in 17 patients with CAO and 12 normal controls. The incremental workload was 10 W /min in CAO group and 25 W/min in control group. The reliability of VT in each group was investigated by the calculation of Spearman correlation coefficient. Results : The detection rates of VT were 100% by RQ, 91.7% by both VEM and $POETO_2$, and 83.3% by VSM in normal control group, while 94.1% by RQ, 64.7% by VEM and $PETO_2$, and 83.3% by VSM in CAO group. Good correlations were noted among VEM, $POETO_2$, and VSM except RQ in normal control group. But there was no significant correlation except between VEM and $PETO_2$ in CAO group. Conclusions : RQ is very sensitive but crude and VEM is near similar to $PETO_2$. The clinical usefulness of VT determined by ventilatory method might be limited in patients with severe CAO.

  • PDF