• Title/Summary/Keyword: maximal power output

Search Result 17, Processing Time 0.022 seconds

Muscle Fatigue Analysis Based on Electromyography Signals for The Evaluation of Low-Level Laser Therapy (저출력 레이저의 치료 효과 규명을 위한 근전도 신호의 피로도 해석 연구)

  • Kim, Ji-Hyun;Choi, Hyo-Hoon;Youn, Jong-In
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.319-327
    • /
    • 2011
  • Skeletal muscle fatigue is defined as a 'any reduction in the maximal capacity to generate force or power output', and is the reduction of oxygen consumption and by-product of metabolism. For the muscle fatigue therapy, low level laser has been introduced that leads the mitochondrial respiratory and attributes the muscle fatigue recovery. This study analyzed the muscle fatigue signals from electromyography(EMG) during low-level laser therapy (LLLT). Healthy subjects performed voluntary elbow flexion-extension excercise and received placebo LLLT and active LLLT using a 830 nm laser diode. Then, EMG were measured for the evaluation of muscle fatigue. The acquired EMG data were analyzed with median frequency and short time fourier transform methods. The results showed that the LLLT had a significant symptomatic relief of muscle fatigue based on the EMG frequency analysis. Therefore, the muscle fatigue analysis with EMG signals can be applied to quantitative evaluation for the monitoring of LLLT effects.

The Performance Analysis of DS-UWB Systems with Multiband Rake Receiver (멀티밴드 레이크 수신기를 적용한 DS-UWB 시스템의 성능분석)

  • Choi Yun-Sung;Kim Su-Nam;Kang Dong-Wook;Kim Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.12
    • /
    • pp.69-75
    • /
    • 2004
  • In the paper, system is combined multiband system with DS-UWB techniques with properties including low peak-to-average power ratio, robustness to multiuser interference and excellent security. Because each sub-band is not satisfied with coherence bandwidth, rake receiver in each sub-band is applied to the Proposed system receiver. Output of rake receiver is combined by using Maximal Ratio combining technology. In this paper we mathematically analyse the BER of the DS-UWB system with singleband and multiband systems in the narrow interference channel condition and multi user interference channel condition, the simulation results show that proposed scheme is getting robuster with increasing of the number of subbands.

The Comparison of Pedalling Performance to according to the Position of Shoe Cleat in Triathletes During Cycling (자전거 운동 중 클릿의 위치 변화에 따른 페달링 수행능력 비교)

  • PARK, Chan-Ho;CHOI, Bo-Kyung;HEO, Bo-Seob;KIM, Yong-Jae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.2
    • /
    • pp.537-543
    • /
    • 2017
  • The purpose of this research is to investigate the effects of different shoe-cleat position on pedalling performance. Four male elite triathletes(age: $22.00{\times}2.16years$, height: $175.12{\pm}8.06cm$, weight: $71.20{\pm}7.89kg$, body fat: $16.62{\pm}3.56%$) and three female elite triathletes(age: $20.00{\pm}1years$, height: $158.40{\pm}2.42cm$, weight: $51.30{\pm}3.89kg$, body fat: $19.26{\pm}2.28%$) participated in 10km time trial and 30sec time trial pedaling tests with the individual time trials based on different shoe-cleat position(cleat front: CF, cleat back: CB). The subjects performed one trial with each type of shoe-cleat position. Maximal power output and average speed were not significantly different during 30s time trial in CF compared with CB. Average power, RPM, and HR were not significantly different during 10k time trial in CF compared with CB. Split time in 1km, 5km, 9km were significantly reduced during 10k time trial in CB compared with CF. We conclude that there was performance advantage in CB using shoe-cleat back position in comparison with CF using shoe-cleat front position.

Long Term Variability of the Sun and Climate Change (태양활동 긴 주기와 기후변화의 연관성 분석)

  • Cho, Il-Hyun;Chang, Heon-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.25 no.4
    • /
    • pp.395-404
    • /
    • 2008
  • We explore the linkage between the long term variability of the Sun and earth's climate change by analysing periodicities of time series of solar proxies and global temperature anomalies. We apply the power spectral estimation method named as the periodgram to solar proxies and global temperature anomalies. We also decompose global temperature anomalies and reconstructed total solar irradiance into each local variability components by applying the EMD (Empirical Mode Decomposition) and MODWT MRA (Maximal Overlap Discrete Wavelet Multi Resolution Analysis). Powers for solar proxies at low frequencies are lower than those of high frequencies. On the other hand, powers for temperature anomalies show the other way. We fail to decompose components which having lager than 40 year variabilities from EMD, but both residuals are well decomposed respectively. We determine solar induced components from the time series of temperature anomalies and obtain 39% solar contribution on the recent global warming. We discuss the climate system can be approximated with the second order differential equation since the climate sensitivity can only determine the output amplitude of the signal.

Design of the Optimal Phase for the Interpolant Filter in the Second-order Bandpass Sampling System (2차 BPS 시스템의 interpolant 필터에 대한 최적 위상 설계)

  • Baek, Jein
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.132-139
    • /
    • 2016
  • In the bandpass sampling(BPS), the sampling frequency for the analog-to-digital converter is lower than that of the signal to be sampled. Since the BPS operation results in the signal spectrum to be copied on the baseband, it is possible for the frequency down-converter to be conveniently omitted. The second-order BPS system is introduced in order to cancel the aliased interference components from the BPS output that may be generated by the BPS processing. In this paper, we introduce a design method for the optimal phase of the interpolant filter in the second-order BPS system which enables to maximally cancel the aliased components. Being mathematically derived, this method can always be applied independently to the spectral characteristics of the BPS input signal. The performance improvements by the suggested method has been measured statistically with various power spectra of the received signal, and it has been shown that the maximal amount of the improvements reaches up to 5~20 [dB] in comparison with the previous suboptimal algorithm.

Aerobic Capacity and Ventilatory Response During Incremental Exercise in Elite High School Cyclist (점진부하 운동에서 중고교 엘리트 사이클 선수들의 유산소능력과 폐환기 반응)

  • Lee, Dae-Taek;Bae, Yoon-Jung
    • Journal of Life Science
    • /
    • v.20 no.3
    • /
    • pp.437-443
    • /
    • 2010
  • This study was designed to examine the aerobic capacity and ventilatory response during an incremental exercise in elite high school cyclists. Twelve boys ($17{\pm}1\;yr$, $175{\pm}5\;cm$, $70{\pm}9\;kg$) participated in anthropometric measurements, incremental exercise testing, and pulmonary function tests. During incremental exercise testing using a cycle ergometer, their maximal oxygen uptake ($VO_2max$), maximal power output, ventilation, ventilatory equivalents for oxygen ($V_E/VO_2$) and carbon dioxide ($V_E/VCO_2$), respiratory rate, and tidal volume were measured. Time variables such as inspiratory time (Ti), expiratory time (Te), breathing time (Tb), and inspiratory duty cycle (Ti/Tb), as well as inspiratory flow rate ($V_T$/Ti) were assessed. Pulmonary function of vital capacity (FVC), forced expiratory volume in one second ($FEV_1$), $FEV_1$/FVC, and peak expiratory flow were evaluated. Their $VO_2max$, maximal heart rate, and Wmax were $57.5{\pm}3.9\;ml{\cdot}kg^{-1}{\cdot}min^{-1}$, $194.1{\pm}8.6\;beat{\cdot}min^{-1}$, and 452 W, respectively. $VO_2max$ was not related to any anthropometric parameters. Most ventilatory variables progressively increased with exercise intensity. As intensity increased, Ti, Tb, Tb decreased while Ti/Tb was maintained. Below an intensity of 250 W, height, weight, body mass index, and body surface were highly correlated with $V_T$/Ti and Ti/Tb (p<0.05). Collectively, $VO_2max$ appeared to be lower than adult cyclists, suggesting a different pattern of ventilatory control as age advances. Morphological characteristics were not related to $VO_2max$ in the population. Time variables of ventilatory response seemed to be related only at an exercise intensity level of less than 250 W. $V_T$/Ti may be related to exercise endurance capacity, but Ti/Tb was similar to adult cyclists.

Biomechanical Comparison of Good and Bad Performances within Individual in Maximum Vertical Jump (최대 수직 점프시 개인내 우수 수행과 비우수 수행의 역학적 비교)

  • Kim, Yong-Woon;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.3
    • /
    • pp.489-497
    • /
    • 2009
  • The purpose of this study was to find differences of jumping performances within individual and to identify the influencing factors in these differences. 20 male subjects performed 6 maximal vertical jumps. The best(GP) & worst(BP) performance of each subject based on their jump height were compared in further analysis. There was a significant difference of approx. 10% in the jump height between GP and BP, which resulted from height of COM and vertical velocity at the instant of take-off. We could observe a significantly higher ankle moment in the GB more than the BP but no significant differences for the knee and hip joint. Also the maximum power of ankle joints in the GP were significantly higher than that in the BP. According to the results, the mechanical output of knee and hip joint are not as influential as that of ankle joint for difference of performance within individual. In conclusion, the results showed that mechanical output of the ankle joint could be more influential factors on the performances within individual although the knee and hip joint play an important role in the vertical jump. We therefore propose that more emphasis should be placed on the potentiation of the ankle joint for the training of the maximum vertical jump.