• 제목/요약/키워드: maximal power output

검색결과 17건 처리시간 0.023초

Evaluation of the Wind Power Penetration Limit and Wind Energy Penetration in the Mongolian Central Power System

  • Ulam-Orgil, Ch.;Lee, Hye-Won;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권6호
    • /
    • pp.852-858
    • /
    • 2012
  • This paper describes evaluation results of the wind power penetration limit (WPPL) and the wind energy penetration (WEP) in the Mongolian central power system (MCPS). A wind power plant (WPP) in a power system possesses an output power limit because the power system must maintain a balance between the generation and consumption of electricity at all times in order to achieve an adequate level of quality. The instantaneous penetration limit (IPL) of wind generation at a load is determined as the minimum of the three technical constraints: the minimum output, the ramp rate capability, and the spinning reserve of the conventional generating units. In this paper, a WPPL is defined as the maximum IPL divided by the peak load. A maximal variation rate (VR) of wind power is a major factor in determining the IPL, WPPL, and WEP. This paper analyzes the effects of the maximal VR of wind power on the WPPL, WEP, and capacity factor (CF) in the MCPS. The results indicate that a small VR can facilitate a large amount of wind energy while maintaining a high CF with increased wind power penetration.

A sun tracking control system using two DOF active sensor array

  • Ha, Yun-Su;Kim, Jong-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권10호
    • /
    • pp.1310-1317
    • /
    • 2014
  • In our daily life, the need of energy increases day by day. However, the amount of natural resources on the earth is limited and thus gaining renewable energy as an energy resource is one of the important and urgent problems. Solar energy is one of the most popular available energy sources that can be converted into electricity by using solar panels. In order for solar panels to produce maximal output power, the incident angle of the sunlight needs to be persistently perpendicular to the solar panel. By the way, most of the solar panels are installed at fixed position and direction. Therefore, as the sun's position changes, it is impossible to produce maximal output power inevitably. To improve this problem, in this paper, a sun tracking system using two degree-of-freedom (DOF) active sensor array is proposed so that the solar panel may always direct sunlight perpendicularly. And also a series of software, such as a search mode and a holding mode, which can control the developed sun tracking system is developed. Several experiments using the implemented sun tracking system are executed and the effectiveness of the system is verified from the experimental results.

적응형 ODFM/MIMO 시스템의 성능 분석 (Performance Analysis of a Adaptive OFDM-MIMO System)

  • 강희훈;이영종;한완옥;현동환
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.481-482
    • /
    • 2007
  • This paper demonstrates OFDM with adaptive modulation applied to Multiple-Input Multiple-Output (MIMO) systems. We apply an optimization algorithm to obtain a bit and power allocation for each subcarrier assuming instantaneous channel knowledge. The analysis and simulation is considered in two stages. The first stage involves the application of a variable-rate variable-power MQAM technique for a Single-Input Single-Output(SISO) OFDM system. This is compared with the performance of fixed OFDM transmission where a constant rate is applied to each subcarrier. The second stage applies adaptive modulation to a general MIMO system by making use of the Singular Value Decomposition to separate the MIMO channel into parallel subchannels. For a two-input antenna, two-output antenna system, the performance is compared with the performance of a system using selection diversity at the transmitter and maximal ratio combining at the receiver.

  • PDF

운동검사시간이 최대산소섭취량과 정체현상에 미치는 영향 (The Effect of Duration Protocols on VO2max and Presence of Plateau)

  • 김도연;윤병곤
    • 생명과학회지
    • /
    • 제19권12호
    • /
    • pp.1712-1717
    • /
    • 2009
  • 이 연구의 목적은 자전거 에르고미터 점증 부하 운동 검사를 통하여 4가지 다른 운동 검사시간 프로토콜(protocol)이 최대 산소 섭취량($VO_2$max)과 산소 섭취량 정체($VO_2$plateau)에 어떠한 영향을 미치는지를 비교 분석하는 것이다. 연구를 위하여 설정된 운동 시간 프로토콜은 5, 8, 12 그리고 16분이다. 평균 이상의 자전거 운동 능력을 지닌 20명의 자발적 피 실험자들이 연구에 참여하였다. 8분 프로토콜의 평균 최대 산소 섭취량($3.66{\pm}0.88\;l/min$)은 통계적으로(p<0.05) 12분($3.49{\pm}0.76\;l/min$)과 16분 프로토콜의($3.45{\pm}0.73\;l/min$) 최대 산소 섭취량보다 높게 제시되었다. 5분 프로토콜의 평균 최대 산소 섭취량은 두 번째로 높은 수치를 나타냈으나, 통계적으로 12분과 16분 프로토콜의 최대 산소 섭취량과는 다르지 않았다(p>0.05). 평균 최대 운동 강도(average maximal power output)는 운동 검사시간들이 영향을 미치는 것으로 나타났다. 5분 프로토콜의 평균 최대 운동 강도가 8분 프로토콜 보다 12%, 12분 프로토콜 보다 24%, 그리고 16분 프로토콜 보다 35% 높게 나타났다. 산소 섭취량 정체($VO_2$plateau)는 5분 프로토콜에서 12.5%, 8분 프로토콜에서 56.25%, 12분 프로토콜에서 37.5%, 그리고 16분 프로토콜에서 56.25%의 빈도를 보였다. 이 연구는 평균 이상의 운동 능력을 지닌 피 실험자에게는 6분에서 10분 사이의 검사시간이 적합하다고 제안하고 있다.

동적 고성능과 최대 전력 효율을 위한 유도 전동기 회전자 속도와 회전자 자속의 선형 비간섭 제어 (LINBAR DECOUPLING CONTROL OF ROTOR SPEED AND ROTOR FLUX IN INDUCTION MOTOR FOR HIGH DYNAMIC PERFORMANCE AND MAXIMAL POWER BFFICLENCY)

  • 김동일;하인중;고명삼;박재화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1989년도 하계종합학술대회 논문집
    • /
    • pp.48-53
    • /
    • 1989
  • We attempt to achieve both high dynamic performance and maximal power efficiency by means of linear decoupling of rotor speed (or motor torque) and rotor flux. The induction motor with our controller possesses the input-output dynamic characteristics of a linear system such that the rotor speed (or motor torque) and the rotor flux are decoupled. The rotor speed (or motor torque) responses are not affected by abrupt changes in the rotor flux and vice versa. The rotor flux need not be measured but is estimated by the well-known flux simulator. The effect of large variation in the rotor resistance on the control performances is minimized by employing a parameter adaptation method. To illuminate the significance of our work. we present simulation and experimental results as well as mathematical performance analyses.

  • PDF

MRT 기법 사용 시 다중 사용자 다중 안테나 하향링크 시스템에서의 에너지 효율 향상을 위한 최적화 알고리즘 (Optimization Algorithm for Energy-Efficiency in the Multi-user Massive MIMO Downlink System with MRT Precoding)

  • 이정수;한용규;심동규;이충용
    • 전자공학회논문지
    • /
    • 제52권8호
    • /
    • pp.3-9
    • /
    • 2015
  • 본 논문에서는 사용 가능한 최대 송신 전력과 만족해야 하는 최소 전송률에 대한 제한 조건 아래에서, maximal ratio transmission (MRT) 기법 사용 시 다중 사용자 다중 안테나 하향링크 시스템의 에너지 효율을 최대화하는 최적의 안테나 수와 송신 전력을 찾는 알고리즘을 제시한다. 순시 채널에 대한 최적화 문제는 직접 풀기 어려우므로 단말 간 채널의 독립성, 평균 채널 이득, 평균 path loss를 이용하여 근사한다. 근사된 에너지 효율에 대한 최적화 문제는 두 개의 변수를 동시에 고려해야 하는 2차원 최적화 문제가 된다. 우리는 이러한 2차원 최적화 문제를 라그랑지 승수법과 제안하는 알고리즘을 통하여 최적의 안테나 수와 송신 전력을 구한다. 실험을 통해, 제안하는 알고리즘으로 구한 최적의 송신 안테나 수와 송신 전력이 exhaustive search로 찾은 값과 근사함을 확인한다.

풍력단지의 최대 운동에너지 보유를 위한 예비력 분배 (Reserve distribution to maximize the kinetic energy of a wind power plant)

  • 윤기환;이진식;이혜원;강용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.179-180
    • /
    • 2015
  • High wind penetration might cause the frequency stability problem because a wind power plant (WPP) is operating in a maximum power tracking mode to extract the maximal energy from wind and thus does not react to the system frequency variation. Therefore, the system operators encourage a WPP to participate in frequency control, which includes inertia/orl and primary control. The frequency support capability of a WPP depends on the amount of kinetic energy (KE) and reserve. This paper formulates an optimization problem to maximize KE while retaining the required reserve. The proposed optimization problem would allow wind generators (WGs) with a smaller wind speed to retaine more KE. The performance of the proposed optimization problem was investigated in a 100-MW WPP consisting of 20 units of 5-MW permanent magnet synchronous generators using an EMTP-RV simulator. The results show that the proposed optimization problem successfully improves the frequency nadir more than a conventional reserve allocation that distributes WGs proportional to the current output.

  • PDF

CDMA 역방향 링크의 상관된 SIMO 채널을 위한 복합형 빔 성형 방식 (Hybrid Beamformer of CDMA Reverse Link in the Correlated SIMO Channel)

  • 최영관;김동구
    • 대한전자공학회논문지TC
    • /
    • 제41권11호
    • /
    • pp.81-86
    • /
    • 2004
  • 부호분할다중접속(CDMA: Code Division Multiple Access) 시스템의 역방향링크에서 수신 빔 성형 기법을 사용할 경우, 빔 성형 이득을 얻는 반면 전력 제어에 의해 불충분한 파일롯 전력으로 인해 채널 추정이 부정확해진다. 이 논문에서는 상관된 단일-입력 다중-출력(SIMO: Single-Input Multiple-Output) 채널에서 불충분한 파일롯 전력으로 인한 문제를 해결하기 위한 수신 빔 성형 방식을 제안하고자 한다. 제안된 복합형 빔 성형 방식(hybrid beamformer)은 수신 안테나들을 그룹 지어서, 각 그룹 당 수신 빔 방향(DOA: Direction-of-Arrival) 기반의 빔 성형 후에, 그룹별 출력을 최대 비 결합(MRC: Maxim Ratio Combining)하는 방식으로, 공간적으로 상관된 SIMO 채널의 디버시티 이득을 얻으면서 더 정확한 채널추정과 간섭제거 효과를 제공한다. 배열 안테나의 수가 여섯 개 이상인 경우, 복합형 빔 성형 방식은 빔 수신 각 범위(AOS: Angle-of-Spread)가 30°이하에서 일반적인 MRC 빔 성형 방식보다 더 좋은 성능을 보인다.

최근접 벡터 제어기법을 이용한 cascade 3상 IHCML 인버터 (Cascade 3-Phase IHCML Inverter using Maximal Distension Vector Control)

  • 박진현;박성준;송성근
    • 조명전기설비학회논문지
    • /
    • 제23권5호
    • /
    • pp.101-109
    • /
    • 2009
  • 본 논문에서는 변압비가 다른 2개의 삼상 변압기를 이용한 새로운 방식의 cascade 3상 IHCML(Isolated H-bridge Cascade Multi-Level) 인버터 및 제어 방식을 제안한다. 또한 cascade 3상 IHCML 인버터를 제어하기 위해 최근접 벡터를 이용한 벡터제어 기법을 사용하였다. 이로 인해 많은 전력을 담당하는 대용량 H-bridge의 스위칭 주파수는 출력 기본주파수와 거의 동일하여 제어 스위치 손실이 작으며, 작은 전력을 담당하는 저용량 H-bridge의 스위칭 주파수는 높게 제어 하므로 출력전압의 품질이 향상되었다.

Inter-Cell Interference Management for Next-Generation Wireless Communication Systems

  • Kwon, Ho-Joong;Ko, Soo-Min;Seo, Han-Byul;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • 제10권3호
    • /
    • pp.258-267
    • /
    • 2008
  • In this paper, we examine what changes the next-generation wireless communication systems will experience in terms of the technologies, services, and networks and, based on that, we investigate how the inter-cell interference management should evolve in various aspects. We identify that the main driving forces of the future changes involve the data-centric services, new dynamic service scenarios, all-IP core access networks, new physical-layer technologies, and heavy upload traffic. We establish that in order to cope with the changes, the next-generation inter-cell interference management should evolve to 1) set the objective of providing a maximal data rate, 2) take the form of joint management of power allocation and user scheduling, 3) operate in a fully distributed manner, 4) handle the time-varying channel conditions in mobile environment, 5) deal with the changes in interference mechanism triggered by the new physical-layer technologies, and 6) increase the spectral efficiency while avoiding centralized coordination of resource allocation of the users in the uplink channel.