• Title/Summary/Keyword: material degradation

Search Result 1,608, Processing Time 0.032 seconds

Condensation Prevention Performance Assessment Taking Into Account Thermal Insulation Performance Degradation Due to Aging for Apartment Housing

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.15 no.6
    • /
    • pp.11-18
    • /
    • 2015
  • Purpose: The current study analyzed trends in thermal insulation performance with aging, and condensation characteristics caused by the former. Method: Thermal insulation and condensation prevention performance of an architecture were assessed using Temperature Difference Ration Inside, or TDRi. Subjects of this quantitative analysis in thermal insulation performance change due to aging included recently constructed apartments and aged apartments older than 40 years. Time series comparison and analysis were conducted to observed changes in the thermal insulation performance and condensation characteristics. Result: Analysis showed that wall insulation performance degraded with aging regardless of fortified insulating material usage or insulating material type, which caused increased danger of condensation. In addition, when fortified insulating material was installed on the connection between the walls, insulation performance degradation was lower compared to cases in which fortified materials were not used. In all cases from 1 to 10, the rate of thermal insulation performance degradation increased after 20 years of aging.

The influence of cathode material on the stability of organic photovoltaics (Cathode material에 따른 organic photovoltaics 안정성의 영향)

  • Park, Jun-Ki;Kim, Yong-Hoon;Han, Jeong-In
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1266-1267
    • /
    • 2011
  • We studied the influence of cathode material on the stability of organic phtovoltaics (OPVs). OPVs with LiF/Al and Ag/Ca/Ag cathode were fabricated and the stability were evaluated. The sample with LiF/Al cathode showed efficiency degradation from 2.42% to 2.04% during 50 days. On the other hand, the sample with Ag/Ca/Ag cathode showed more steeper efficiency degradation from 2.38% to 0.80% during 50 days. The different of degradation can be attributed to a larger increase of series resistance ($R_s$) in Ag/Ca/Ag cathode sample.

  • PDF

Material Degradation in KS D 3503 SS400 Rolled Steel at $179^{\circ}C$ (KS D 3503 SS400 압연강 $179^{\circ}C$에서의 재질열화 연구)

  • Baek, Un-Bong;Park, Jong-Seo;Nahm, Seung-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.4 s.76
    • /
    • pp.13-18
    • /
    • 2006
  • In spite of frequent defect in industrial boilers, life assessment or diagnostic method for them has not been actively studied. In this research, SS400 carbon steel used in industrial boilers is simulated with artificial aging heat treatment. To do qualitative life assessment, differences in micro-structures and hardness of SS400 by the degradation time are studied. In addition, variation in material properties by aging was observed with the tensile test at room temperature and $179^{\circ}C$ and changes in ductile to brittle transition temperature was observed with the charpy impact test performed at several test temperature.

Low Cycle Fatigue Characteristics of Duplex Stainless Steel with Degradation under Pure Torsional Load (순수 비틀림 하중하에서 열화를 고려한 2상 스데인리스강의 저주기 피로특성)

  • Gwon, Jae-Do;Park, Jung-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1897-1904
    • /
    • 2002
  • Monotonic torsional and pure torsional low cycle fatigue(LCF) test with artificial degradation were performed on duplex stainless steel(CF8M). CF8M is used in pipes and valves in nuclear reactor coolant system. It was aged at 430$^{\circ}C$ for 3600hrs. Through the monotonic and LCF test, it is found that mechanical properties(i.e., yield strength, strain hardening exponent, strength coefficient etc.) increase and fatigue life(N$\sub$f/) decreases with degradation of material. The relationship between shear strain amplitude(${\gamma}$$\sub$a/)and N$\sub$f/ was proposed.

Study on UV degradation in Polymeric Insulating Materials for Use in Outdoor Insulators by Corona-Charging (코로나 대전을 통한 옥외용 고분자 절연재료의 자외선 열화특성 연구)

  • Youn, Bok-Hee;An, Jong-Sik;Lee, Sang-Yong;Huh, Chang-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.106-109
    • /
    • 2001
  • In this paper, we have investigated the degradation of shed materials of outdoor insulators by UV-radiation by using corona-charging and XPS analysis. The accumulated charges on polymeric surface having intrinsic hydrophobic property have a negative impact on retaining its hydrophobicity. Therefore, shorter decay times of surface charges are preferred. The surface voltage decay on UV-treated silicone rubber and EPDM show a different decay trend with UV treated time. From the XPS analysis, the oxidized groups of silica-like structure in silicone rubber increase with UV treatment time. For EPDM, the oxidized carbon groups of C=O, O=C-O increase as elapse of UV radiation time. These oxidized surface for each material have different electrostatic characteristics, so deposited charges may be expected to have different impacts on their surface hydrophobicity. The degradation mechanism based on our results is discussed.

  • PDF

A Study on the Surface Properties of Epoxy Insulator by Water Degradation (수분열화에 의한 에폭시절연재료의 표면특성에 관한 연구)

  • 임경범;이백수;김종택;정무영;황명환;이덕출
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.199-202
    • /
    • 1998
  • In examining application of polymer as electrical insulators, it is very important to perform accelerated aging test substituted the process which polymer insulator is degraded for long-time by the process of short-time. The purpose of this paper is to examine the properties of water degradation which affect on the efficiency of epoxy insulator. To do this, the surface properties on epoxy insulating material have been investigated after long-time accelerated degradation in boiling water condition. The experimental results showed the contact angle and surface resistivity after treatment to decrease the sample of water treatment. In dielectric properties, dielectric constant was increased by the aging development with water treatments.

  • PDF

Analysis of the Inner Degradation Pattern by Clustering Algorism at Distribution Line (군집화 알고리즘을 이용한 배전선로 내부 열화 패턴 분석)

  • Choi, Woon-Shik;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.1
    • /
    • pp.58-61
    • /
    • 2016
  • Degradation in power cables used in distribution lines to the material of the wire, manufacturing method, but also the line of the environment, generates a variety of degradation depending upon the type of load. The local wire deterioration weighted wire breakage accident can occur frequently, causing significant proprietary damage can lead to accidents and precious. In this study, the signal detected by the eddy current aim to develop algorithms capable of determining the signals for the top part and at least part of the signal by using a signal processing technique called K-means algorithm.

Analysis of Element distribution and Degradation Characteristics in the grain boundary of ZnO Ceramic Varistors with EPMA (EPMA를 이용한 ZnO 세라믹 바리스터 입계의 원소분포와 열화특성 분석)

  • So, Soon-Jin;Kim, Young-Jin;Park, Young-Soon;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.64-67
    • /
    • 2000
  • Element distribution analysis and degradation characteristics of the ZnO varistors fabricated at the ambient sintering-process is investigated in this study. ZnO varistors made of Matsuoka's composition were fabricated by standard ceramic techniques. The ambient sintering-process is performed at the special electrical-furnace which is equipped with the vacuum system. The Gases of injection at sintering- process were oxygen, air, nitrogen and argon respectively. Element and quantitative analysis in the microstructure of ZnO varistors made use of EPMA equipment. Degradation characteristics were showed by DC degradation tests at $115{\pm}2\;^{\circ}C$ for period up to 13 h. From above analysis, it is found that at the DC degradation test the ZnO varistor sintered in oxygen atmosphere showed the excellent prop properties among them and these results could be explain by element and quantitative analysis in ZnO microstructure.

  • PDF

Tracking Resistance and Aging Characteristics of Epoxy Insulating Materials by the Rotating Wheel Dip Test (Rotating Wheel Dip Test에 의한 에폭시 절연재료의 내트래킹성과 열화 특성)

  • Cho, Han-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.530-537
    • /
    • 2008
  • This paper describes the results of a study on the tracking performance of outdoor insulating materials based on the rotating wheel dip test(RWDT). And, the influence of surface degradation was evaluated through such as measurement of the flashover voltage after and before tracking test, also aspects of surface degradation using scanning electron microscopy. The time to tracking breakdown of treated filled specimen is longer than untreated filled specimen. And, after the RWDT, the surface of specimen by adding untreated filler appeared heavy erosion. It was found that the addition to surface treated filler, the better tracking resistance. In the RWDT, the breakdown specimen is not affected by the dry flashover voltage, despite the fact that the surface degradation of tracking test has different state on each specimen. This suggests that wet flashover voltage play an important role in evaluating of tracking and erosion on the surface degradation in tracking test. And, the flashover voltage of specimen under wet conditions are greatly affected by the salt concentration and degree of degradation by the RWDT Because of hydrophobicity and degree of degradation by the RWDT, the flashover voltage of treated filled specimen is higher than that of untreated filled specimen. Different types of specimen may have different hydrophobicity and their surface state under contaminated conditions may not be the same.

The Characteristics on the Accelerated Degradation of Bi-based Varistor fabricated with ZnO Nano-powder (ZnO 나노파우더로 제조된 Bi계 바리스터의 가속열화 특성)

  • Wang, Min-Sung;Wang, Zengmei;Lee, Dong-Gyu;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.203-204
    • /
    • 2006
  • Nano-Varistors fabricated with ZnO 30nm and 80nm powders were studied about the electrical characteristics with AC accelerated degradation in this paper Especially, ZnO nano-powder varistors were sintered m air at $1050^{\circ}C$ and analyzed the phenomenons of before and after AC degradation test. The stress conditions of AC degradation test were $1.0V_{1mA}$ $115{\pm}2^{\circ}C$ for 24h. 80nm-varistor was exhibited better performance than 30nm-varistor m the electrical stabilities. And then 80nm-varistor resulted m the degradation characteristics that the variation rate of operating voltage, nonlinear coefficient and leakage current was -0 3%, -0 4% and -3 3%, respectively.

  • PDF