• Title/Summary/Keyword: material Intensity

Search Result 1,575, Processing Time 0.032 seconds

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.

In Vivo Dosimetry with MOSFET Detector during Radiotherapy (방사선 치료 중 MOSFET 검출기를 이용한 체표면 선량측정법)

  • Kim Won-Taek;Ki Yong-Gan;Kwon Soo-Il;Lim Sang-Wook;Huh Hyun-Do;Lee Suk;Kwon Byung-Hyun;Kim Dong-Won;Cho Sam-Ju
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.17-23
    • /
    • 2006
  • In Vivo dosimetry is a method to evaluate the radiotherapy; it is used to find the dosimetric and mechanical errors of radiotherapy unit. In this study, on-line In Vivo dosimetry was enabled by measuring the skin dose with MOSFET detectors attached to patient's skin during treatment. MOSFET dosimeters were found to be reproducible and independent on beam directions. MOSFET detectors were positioned on patient's skin underneath of the dose build-up material which was used to minimize dosimetric error. Delivered dose calculated by the plan verification function embedded in the radiotherapy treatment planning system (RTPs), was compared with measured data point by point. The dependency of MOSFET detector used in this study for energy and dose rate agrees with the specification provided by manufacturer within 2% error. Comparing the measured and the calculated point doses of each patient, discrepancy was within 5%. It was enabled to verify the IMRT by using MOSFET detector. However, skin dosimetry using conventional ion chamber and diode detector is limited to the simple radiotherapy.

  • PDF

Experimental Study on Fatigue Characteristics of the Single Spot Welded Joint (점용접재(点熔接材)의 피로(疲勞) 특성(特性)에 관한 실험적(實驗的) 연구(硏究))

  • Chang-Min Suh;Sung-Soo Kang;Nam-Seong Hwang;Yong-Ich Cho
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.29 no.4
    • /
    • pp.214-226
    • /
    • 1992
  • In this paper, the characteristics of fatigue crack growth in the spot welded joint of the same kinds of specimens($HS{\times}HS,\;GA{\times}GAB$) and different kinds of specimens($HS{\times}GA,\;HS{\times}GAB$) which consist of dual phase high strength steel(HS) and monogalvanized steel(GA) were examined with static tension tests and axial tension fatigue tests. Some of the important results are as follows : 1. The divergence of tensile strengths among the same and different kinds of spot welds under the same conditions is comparatively low regardless of the difference of stiffness. 2. At the low load bevel and long life legion, the fatigue crack is initiated near the nugget. However, in the high load level and short life region, it occurs a tittle far from the nugget. 3. It has shown a linear relation between maximum stress Intensity factor, Kmax and fatigue life, $N_f$ among each of the spot welds and has gathered in a narrow band on the log-log graph paper. $Kmax=H{\cdot}{N_f}^{P}$ where H and P are a material constant.

  • PDF

Laser Acceleration of Electron Beams to the GeV-class Energies in Gas Jets

  • Hafz, Nasr A.M.;Jeong, Tae-Moon;Lee, Seong-Ku;Choi, Il-Woo;Pae, Ki-Hong;Kulagin, Victor V.;Sung, Jae-Hee;Yu, Tae-Jun;Cary, John R.;Ko, Do-Kyeong;Lee, Jong-Min
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.1
    • /
    • pp.8-14
    • /
    • 2009
  • In a laser-plasma wakefield accelerator, the ponderomotive force of an ultrashort high intensity laser pulse excites a longitudinal wave or plasma bubble in a way similar to the excitation of a wake wave behind a boat as it propagates on the water surface. Electric fields inside the plasma bubble can be several orders of magnitude higher than those available in conventional RF-based particle accelerator facilities which are limited by material breakdown. Therefore, if an electron bunch is properly phase-locked with the bubble's acceleration field, it can gain relativistic energies within an extremely short distance. Here, in the bubble regime we show the generation of stable and reproducible sub GeV, and GeV-class electron beams. Supported by three-dimensional particle-in-cell simulations, our experimental results show the highest acceleration gradients produced so far. Simulations suggested that the plasma bubble elongation should be minimized in order to achieve higher electron beam energies.

Luminous Characteristics of Transparent Field Emitters Produced by Using Ultra-thin Films of Single Walled Carbon Nanotubes

  • Jang, Eun-Soo;Goak, Jeung-Choon;Lee, Han-Sung;Lee, Seung-Ho;Lee, Nae-Sung
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.31.1-31.1
    • /
    • 2009
  • Carbon nanotubes (CNTs) are attractive material because of their superior electrical, mechanical, and chemical properties. Furthermore, their geometric features such as a large aspect ratio and a small radius of curvature at tip make them ideal for low-voltage field emission devices including backlight units of liquid crystal display, lighting lamps, X-ray source, microwave amplifiers, electron microscopes, etc. In field emission devices for display applications, the phosphor anode is positioned against the CNT emitters. In most case, light generated from the phosphor by electron bombardment passes through the anode front plate to reach observers. However, light is produced in a narrow depth of the surface of the phosphor layer because phosphor particles are big as much as several micrometers, which means that it is necessary to transmit through the phosphor layer. Hence, a drop of light intensity is unavoidable during this process. In this study, we fabricated a transparent cathode back plate by depositing an ultra-thin film of single walled CNTs (SWCNTs) on an indium tin oxide (ITO)-coated glass substrate. Two types of phosphor anode plates were employed to our transparent cathode back plate: One is an ITO glass substrate with a phosphor layer and the other is a Cr-coated glass substrate with phosphor layer. For the former case, light was radiated from both the front and the back sides, where luminance on the back was ~30% higher than that on the front in our experiments. For the other case, however, light was emitted only from the cathode back side as the Cr layer on the anode glass rolled as a reflecting mirror, improving the light luminance as much as ~60% compared with that on the front of one. This study seems to be discussed about the morphologies and field emission characteristics of CNT emitters according to the experimental parameters in fabricating the lamps emitting light on the both sides or only on the cathode back side. The experimental procedures are as follows. First, a CNT aqueous solution was prepared by ultrasonically dispersing purified SWCNTs in deionized water with sodium dodecyl sulfate (SDS). A milliliter or even several tens of micro-liters of CNT solution was deposited onto a porous alumina membrane through vacuum filtration. Thereafter, the alumina membrane was solvated with the 3 M NaOH solution and the floating CNT film was easily transferred to an ITO glass substrate. It is required for CNT film to make standing CNTs up to serve as electron emitter through an adhesive roller activation.

  • PDF

Antioxidants Activity of Aged Red Garlic (숙성 홍마늘의 생리활성)

  • Lee, Soo-Jung;Shin, Jung-Hye;Kang, Min-Jung;Jung, Woo-Jae;Ryu, Ji-Hyun;Kim, Ra-Jeong;Sung, Nak-Ju
    • Journal of Life Science
    • /
    • v.20 no.5
    • /
    • pp.775-781
    • /
    • 2010
  • The antioxidant activities of hot water extracts from fresh, red and black garlic processed in low temperatures were compared. The chromaticity value of browning garlic was between that of fresh and black garlic. Red garlic was similar in browning intensity to fresh garlic. Also, total phenol, flavonoids, total pyruvate and thiosulfate contents were similar between fresh and black garlic. DPPH, ABTs, NO radical scavenging activity and reducing power of red garlic were significantly higher than fresh garlic, but lower than those of black garlic. $\alpha$-Glucosidase inhibitory activity in red garlic was similar to that in black garlic. Antioxidant activities of red garlic were higher than fresh garlic but lower than black garlic, and it was confirmed that antioxidant activity by production of browning material through the thermal process was the main parameter of the biological activity in the aged red garlic.

Verification of precipitation enhancement by weather modification experiments using radar data (레이더 자료를 이용한 기상조절 실험에 의한 강수 증가 검증 연구)

  • Ro, Yonghun;Cha, Joo-Wan;Chae, Sanghee
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.999-1013
    • /
    • 2020
  • Weather modification research has been actively performed worldwide, but a technology that can more quantitatively prove the research effects are needed. In this study, the seeding effect, the efficiency of precipitation enhancement in weather modification experiment, was verified using the radar data. Also, the effects of seeding material on hydrometeor change was analyzed. For this, radar data, weather conditions, and numerical simulation data for diffusion were applied. First, a method to analyze the seeding effect in three steps was proposed: before seeding, during seeding, and after seeding. The proposed method was applied to three cases of weather modification experiments conducted in Gangwon-do and the West Sea regions. As a result, when there is no natural precipitation, the radar reflectivity detected in the area where precipitation change is expected was determined as the seeding effect. When natural precipitation occurs, the seeding effect was determined by excluding the effect of natural precipitation from the maximum reflectivity detected. For the application results, it was found that the precipitation intensity increased by 0.1 mm/h through the seeding effect. In addition, it was confirmed that ice crystals, supercooled water droplets, and mixed-phase precipitation were distributed in the seeding cloud. The results of these weather modification research can be used to secure water resources as well as for future study of cloud physics.

Microglial Reaction to the Cytotoxicity of 5,7-Dihydroxytryptamine in the Cat Retina (5,7-Dihydroxytryptamine의 세포독성에 의한 고양이 망막내 미세아교세포의 반응양상)

  • Joo, Woo-Hyun;Nam, Seong-Ahn;Jo, Seung-Mook;Cho, Hyon-Hoo;Shin, Min-Cheol;Won, Moo-Ho;Choi, Chang-Do
    • Applied Microscopy
    • /
    • v.28 no.4
    • /
    • pp.425-434
    • /
    • 1998
  • This study was designed to investigate the microglial reactions to the neurodegenerative changes in the cat retina. All experiments were performed using adult cats of both sex, weighing $2,500g\sim3,500g$. 5,7-DHT $(100{\mu}g)$ dissolved in 0.1% ascorbic acid was injected into the vitreous body. All injections were performed in one-side eye; the other side served as the control, which was injected only with 0.1% ascorbic acid. Cats were sacrificed at 1, 3, 7, 14 and 21 days after intravitreal injection of 5,7-DHT For light microscopy, retinae were fixed with 4% paraformaldehyde and processed using NDPase histochemistry. Same retinae were fixed with 1% para(formaldehyde-2.5% glutaraldehyde and processed for electron microscopy. NDPase-positive microglial cells were mainly distributed in the inner plexiform layer of the retina, and characterized by a small somata with a few slender processes, which were also extended in the ganglion cell layer (GCL) and inner nuclear layer (INL). The intensity of the microglia stained for NDPase was abruptly increased at 7 day as compared with that of the control, and thereafter continuously sustained until 21 day, the last experimental group in this study. Under the electron microscopical observation, microglial cells in the control group exhibited elongate nucleus with perinuclear chromatin condensation, and the perikaryon was scanty. However, a few hypertrophic glial cells were frequently found at 3 days after the drug injection. By 7 day, most microglial cells directed toward the degenerated neurons in the GCL, and the number of microglial cells was slightly increased as compared with the former group. At the 14 day, most microglial cells wrapped the degenerated cells in the GCL, and a few cells showed phagocytotic features. By 21 day, most microglial cells were engaged in phagocytotic activity, and their cytoplasm was filled with the phagorytosed material. Based on the results, 5,7-DHT may act as a specific neurotoxin to the cat retina, and microglial reactions to the neuronal death are already induced in early experimental stage. These results indicate that the microglial cells in the cat retina show characteristic features as a protective effect of neural tissue.

  • PDF

Using Balanced Scorecard to Explore Learning Performance of Enterprise Organization

  • Chiu, Chung-Ching;Tsai, Chih-Hung;Chung, Yi-Chan
    • International Journal of Quality Innovation
    • /
    • v.8 no.1
    • /
    • pp.40-75
    • /
    • 2007
  • In the early industrial age which with high intensity of machine and labor, using financial measurement index was good enough to tie in company's mechanization and philosophy of management and been in efficiency. But being comply with "New Economic age," a new economic environment is full of knowledge and information, the enterprise competition had changed from tangible assets, plants to intangible innovation ability of knowledge. As recognizing the new tendency by enterprise, they value gradually the growth and influence from learning. Practice of organization learning not only needs firm structure and be in coordination with both hardware and software, but also needs an affect measurement model to offer enterprise to estimate learning performance. It's a good instrument of financial performance measure mold in the past years, But it's for measuring the past, couldn't formulate enterprise trend to future, hard to estimate investment for future, such as development of products, organization learning, knowledge management etc, as which intangible assets and knowledge ability just the key factors of being win around competition environment in the future. In 1992, Kaplan and Norton brought up Balance Scorecard (BSC) on Harvard Business Review, as an instrument helping enterprise to measure performance, which is being considered to be a most influence management instrument. It added non-financial index such as customer, internal process and learning growth besides traditional financial index, as offering enterprise an index to measure and manage intangible assets and intellectual property. As being aware of organization learning is hard to be ignored in the new economic age, this research is based on learning and growth of BSC, and citing one national material company try to let the most difficult measurement performance of organization learning, to be estimate through BSC, analyze of factor and individual case, to discuss the company how to make the related strategy and vision of organization learning to develop learning and growth of the structure of BSC, subject the matter of out put factors to be discussed, and measure the outcomes as a result of research. The research affect offers (1) the base implement procedure of carrying out BSC; (2) the reference of formulating measurement index while enterprise using BSC to estimate performance of organization learning; (3) the possibility bottleneck maybe forcing while carrying out BSC, to be an improvement or preventive for enterprise.

Optical transition dynamics in ZnO/ZnMgO multiple quantum well structures with different well widths grown on ZnO substrates

  • Li, Song-Mei;Kwon, Bong-Joon;Kwack, Ho-Sang;Jin, Li-Hua;Cho, Yong-Hoon;Park, Young-Sin;Han, Myung-Soo;Park, Young-Sik
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.121-121
    • /
    • 2010
  • ZnO is a promising material for the application of high efficiency light emitting diodes with short wavelength region for its large bandgap energy of 3.37 eV which is similar to GaN (3.39 eV) at room temperature. The large exciton binding energy of 60 meV in ZnO provide provides higher efficiency of emission for optoelectronic device applications. Several ZnO/ZnMgO multiple quantum well (MQW) structures have been grown on various substrates such as sapphire, GaN, Si, and so on. However, the achievement of high quality ZnO/ZnMgO MQW structures has been somehow limited by the use of lattice-mismatched substrates. Therefore, we propose the optical properties of ZnO/ZnMgO multiple quantum well (MQW) structures with different well widths grown on lattice-matched ZnO substrates by molecular beam epitaxy. Photoluminescence (PL) spectra show MQW emissions at 3.387 and 3.369 eV for the ZnO/ZnMgO MQW samples with well widths of 2 and 5 nm, respectively, due to the quantum confinement effect. Time-resolved PL results show an efficient photo-generated carrier transfer from the barrier to the MQWs, which leads to an increased intensity ratio of the well to barrier emissions for the ZnO/ZnMgO MQW sample with the wider width. From the power-dependent PL spectra, we observed no PL peak shift of MQW emission in both samples, indicating a negligible built-in electric field effect in the ZnO/$Zn_{0.9}Mg_{0.1}O$ MQWs grown on lattice-matched ZnO substrates.

  • PDF