• Title/Summary/Keyword: matching points

Search Result 710, Processing Time 0.024 seconds

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Development of Template Compensation Algorithm for Interoperable Fingerprint Recognition using Taylor Series (테일러시리즈를 이용한 이기종 지문 센서 호환 템플릿 보정 알고리즘 개발)

  • Jang, Ji-Hyeon;Kim, Hak-Il
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.18 no.4
    • /
    • pp.93-102
    • /
    • 2008
  • Fingerprint sensor interoperability refers to the ability of a system to compensate for the variability introduced in the finger data of individual due to the deployment of different sensors. The purpose of this paper is the development of a compensation algorithm by which the interoperability of fingerprint recognition can be improved among various different fingerprint sensors. In this paper we show that a simple transformation derived to form a Taylor series expansion can be used in conjunction with a set of corresponding minutia points to improve the correspondence of finer fingerprint details within a fingerprint image. This is demonstrated by an applying the transformation to a database of fingerprint images and examining the minutiae match scores with and without the transformation. The EER of the proposed method was improved by average 60.94% better than before compensation.

A Study on Design and Interpretation of Pattern Laser Coordinate Tracking Method for Curved Screen Using Multiple Cameras (다중카메라를 이용한 곡면 스크린의 패턴 레이저 좌표 추적 방법 설계와 해석 연구)

  • Jo, Jinpyo;Kim, Jeongho;Jeong, Yongbae
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.60-70
    • /
    • 2021
  • This paper proposes a method capable of stably tracking the coordinates of a patterned laser image in a curved screen shooting system using two or more channels of multiple cameras. This method can track and acquire target points very effectively when applied to a multi-screen shooting method that can replace the HMD shooting method. Images of curved screens with severe deformation obtained from individual cameras are corrected through image normalization, image binarization, and noise removal. This corrected image is created and applied as an Euclidean space map that is easy to track the firing point based on the matching point. As a result of the experiment, the image coordinates of the pattern laser were stably extracted in the curved screen shooting system, and the error of the target point position of the real-world coordinate position and the broadband Euclidean map was minimized. The reliability of the proposed method was confirmed through the experiment.

A Case Study of Human Resource Nurturing Achievements through Industry-University Cooperation (산학협력을 통한 인력양성 성과도출 사례 연구)

  • Han, JungSoo
    • Journal of Internet of Things and Convergence
    • /
    • v.8 no.5
    • /
    • pp.41-46
    • /
    • 2022
  • This study analyzed the results and implications of the industry-university cooperation human resource nurturing process based on the I-O model for the Motion Graphics major and the Global Hotelier major in Baek seok University. In this study, based on the analysis of the human resources training performance through industry-university cooperation in the motion graphics and hotelier fields for 5 years, what kind of efforts were made for successful human resource training, and the level of performance was analyzed and improvement points were suggested. In this study, four strategies were set for successful industry-university-tailored human resource nurturing: student-industry matching through industry participation in education, industry-university integrated education, education quality advancement, and customized education infrastructure construction. As a result of the analysis, customized human resource training should first be developed through industry demand survey and a mirror-type practice room should be built to fit the corporate environment. Second, it was found that it is possible to be individual only if there is an active participation of industry experts throughout the curriculum such as subjects and non-subjects.

Assessment of Epidemiological Data and Surveillance in Korea Substance Use Research: Insights and Future Directions

  • Meekang Sung;Vaughan W. Rees;Hannah Lee;Mohammad S. Jalali
    • Journal of Preventive Medicine and Public Health
    • /
    • v.57 no.4
    • /
    • pp.307-318
    • /
    • 2024
  • Objectives: Effective data collection and surveillance of epidemiological trends are essential in confronting the growing challenges associated with substance use (SU), especially in light of emerging trends and underreporting of cases. However, research and data are scarce regarding SU and substance use disorder (SUD) in Korea. Methods: We conducted a scoping review to identify data sources and surveillance methods used in SU research in Korea up to December 2023. This review was complemented by semi-structured consultations with experts in this area in Korea, whose feedback led to revisions of previously identified data sources and assessments. Results: Our review identified 32 publications conducting secondary analyses on existing data to examine the epidemiology of SU and SUD in Korea. Of these, 14 studies utilized clinical databases to explore the prescription patterns of addictive substances, particularly opioids. Eleven data sources showed promise for advancing SU research; however, they face substantial limitations, including a lack of available data, missing data, the absence of key variables, the exclusion of marginalized populations not captured within the clinical system, and complexities in matching individual-level data across time points and datasets. Conclusions: Current surveillance methods for SU in Korea face considerable challenges in accessibility, usability, and standardization. Moreover, existing data repositories may fail to capture information on populations not served by clinical or judicial systems. To systematically improve surveillance approaches, it is necessary to develop a robust and nationally representative survey, refine the use of existing clinical data, and ensure the availability of data on treatment facilities.

Mobile Camera-Based Positioning Method by Applying Landmark Corner Extraction (랜드마크 코너 추출을 적용한 모바일 카메라 기반 위치결정 기법)

  • Yoo Jin Lee;Wansang Yoon;Sooahm Rhee
    • Korean Journal of Remote Sensing
    • /
    • v.39 no.6_1
    • /
    • pp.1309-1320
    • /
    • 2023
  • The technological development and popularization of mobile devices have developed so that users can check their location anywhere and use the Internet. However, in the case of indoors, the Internet can be used smoothly, but the global positioning system (GPS) function is difficult to use. There is an increasing need to provide real-time location information in shaded areas where GPS is not received, such as department stores, museums, conference halls, schools, and tunnels, which are indoor public places. Accordingly, research on the recent indoor positioning technology based on light detection and ranging (LiDAR) equipment is increasing to build a landmark database. Focusing on the accessibility of building a landmark database, this study attempted to develop a technique for estimating the user's location by using a single image taken of a landmark based on a mobile device and the landmark database information constructed in advance. First, a landmark database was constructed. In order to estimate the user's location only with the mobile image photographing the landmark, it is essential to detect the landmark from the mobile image, and to acquire the ground coordinates of the points with fixed characteristics from the detected landmark. In the second step, by applying the bag of words (BoW) image search technology, the landmark photographed by the mobile image among the landmark database was searched up to a similar 4th place. In the third step, one of the four candidate landmarks searched through the scale invariant feature transform (SIFT) feature point extraction technique and Homography random sample consensus(RANSAC) was selected, and at this time, filtering was performed once more based on the number of matching points through threshold setting. In the fourth step, the landmark image was projected onto the mobile image through the Homography matrix between the corresponding landmark and the mobile image to detect the area of the landmark and the corner. Finally, the user's location was estimated through the location estimation technique. As a result of analyzing the performance of the technology, the landmark search performance was measured to be about 86%. As a result of comparing the location estimation result with the user's actual ground coordinate, it was confirmed that it had a horizontal location accuracy of about 0.56 m, and it was confirmed that the user's location could be estimated with a mobile image by constructing a landmark database without separate expensive equipment.

A Spectrophotometric Study on Color Differences between Various Light-Cured Composite Resins and Shade Guides (광중합형 복합레진과 shade guide의 색차에 관한 연구)

  • Lim, Kyung-Min;Lee, Min-Ho;Song, Kwang-Yeob
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.13-22
    • /
    • 2009
  • The composite resin, due to its esthetic quality, is considered the material of choice for restoration of anterior teeth. To get a satisfactory result in the composite resin restorations, it is necessary to choose right shade. At present, most of the commercial composite resins are based on the Vita Lumin shade guides or shade guides that are provided by their company, but color differences among them might be expected even using the same shade in various materials. This study is to measure color differences between various light-cured composite resins and shade guides and to provide the clinicians with information which may aid in improved color match of esthetic restoration. Four kinds of light-cured composite resins (Gradia Direct (GD), Z250 (Z250), Clearfil AP-X (AP-X), Esthet X (E X)) and shade guides with A2 and A3 shade were used. Three specimens of each material and one specimen of each shade guide were made. Each composite resin was filled into the Teflon mold (1.35 mm depth, 8 mm diameter), followed by compression, polymerization and polishing with wet sandpaper. Shade guides were grinded with polishing stones and rubber points to a thickness of approximately 1.35 mm. Color characteristics were performed with a spectrophotometer(color i5, GretagMacbeth, USA). A computer-controlled spectrophotometer was used to determine CIELAB coordinates ($L^*$, $a^*$, $b^*$) of each specimen and shade guide. The CIELAB measurements made it possible to evaluate the amount of the color difference values (${\Delta}E^*ab$) between composite resins and shade guides. CIE standard D65 was used as the light source. The results were as follows : 1. Among the $L^*$, $a^*$, $b^*$ values of most of 4 kinds of composite resin specimens which are produced by same shade, there were significant differences(p<0.05). 2. Among all 4 kinds of composite resin specimens which are produced by same shade, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 3. Between most of composite resin specimens investigated and their corresponding shade guides, there were color differences that is perceptible to human eye(${\Delta}E^*>3.3$). 4. In the clinical environment, it is recommended that custom shade guides be made from resin material itself for better color matching. Shade guides supplied by manufacturers or Vita Lumin shade guide may not provide clinicians a accurate standard in matching color of composite resins, and there are perceptible color differences in most of products. Therefore, it is recommended that custom shade guides be made from resin material itself and used for better color matching.

Comparison of Image Uniformity Due to Position Shifting in COR on Myocardial SPECT (Myocardial SPECT시 COR에서 위치변화에 따른 Image Uniformity 비교)

  • Lim, Hyun-Jin;Kim, Joong-Hyun;Kim, Jae-Il;Lim, Jung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.70-75
    • /
    • 2012
  • Purpose: It is important to acquire accurate data because the SPECT scan affected by various physical factors. The aim of this study was to compare the uniformity when both centers were matched or mismatched differed from position of heart in COR. Materials and methods: The images were acquired with cylindrical uniform phantom (6.7 cm diameter, 9 cm length) and heart insert phantom using Cardio MD SPECT system (Philips, USA). The phantoms were positioned on COR as well as four different points which were 10 cm above, below, left and right side from the COR. The counts from the both edge of cylindrical uniform phantom and those from the both wall of heart insert phantom were compared by using vertical and horizontal line profile. In addition, the qualitative evaluation was performed with heart insert phantom images and volunteer test. Results: In heart insert phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 1.1, 4.1, 4.9, 2.2 and 0.9% using T-A curve for horizontal view. In case of vertical view of COR 3.9, 21.9, 3.5, 23.9, 14.0% were shown. In cylindrical phantom study, the differences of counts between COR and 10 cm above, below, left and right point of COR were 4.3, 0.3, 3.3, 2.6 and 0.7% using T-A curve for horizontal view. In case of vertical view of COR 2.7, 3.0, 1.0, 0.3, 3.4% were shown. For qualitative evaluation, the images at COR were the most uniform for both of heart insert phantom and volunteer test, whereas other four positions showed somewhat distorted images. Conclusion: It showed the most uniform images when COR is matched with the heart. Therefore, we can expect that distortion which increased or decreased of myocardial perfusion will be prevented by matching the heart and COR when positioning. Furthermore, the accuracy of diagnosis will be improved as well.

  • PDF

Development of an Automatic 3D Coregistration Technique of Brain PET and MR Images (뇌 PET과 MR 영상의 자동화된 3차원적 합성기법 개발)

  • Lee, Jae-Sung;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Park, Kwang-Suk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.5
    • /
    • pp.414-424
    • /
    • 1998
  • Purpose: Cross-modality coregistration of positron emission tomography (PET) and magnetic resonance imaging (MR) could enhance the clinical information. In this study we propose a refined technique to improve the robustness of registration, and to implement more realistic visualization of the coregistered images. Materials and Methods: Using the sinogram of PET emission scan, we extracted the robust head boundary and used boundary-enhanced PET to coregister PET with MR. The pixels having 10% of maximum pixel value were considered as the boundary of sinogram. Boundary pixel values were exchanged with maximum value of sinogram. One hundred eighty boundary points were extracted at intervals of about 2 degree using simple threshold method from each slice of MR images. Best affined transformation between the two point sets was performed using least square fitting which should minimize the sum of Euclidean distance between the point sets. We reduced calculation time using pre-defined distance map. Finally we developed an automatic coregistration program using this boundary detection and surface matching technique. We designed a new weighted normalization technique to display the coregistered PET and MR images simultaneously. Results: Using our newly developed method, robust extraction of head boundary was possible and spatial registration was successfully performed. Mean displacement error was less than 2.0 mm. In visualization of coregistered images using weighted normalization method, structures shown in MR image could be realistically represented. Conclusion: Our refined technique could practically enhance the performance of automated three dimensional coregistration.

  • PDF

A Three-Dimensional Facial Modeling and Prediction System (3차원 얼굴 모델링과 예측 시스템)

  • Gu, Bon-Gwan;Jeong, Cheol-Hui;Cho, Sun-Young;Lee, Myeong-Won
    • Journal of the Korea Computer Graphics Society
    • /
    • v.17 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • In this paper, we describe the development of a system for generating a 3-dimensional human face and predicting it's appearance as it ages over subsequent years using 3D scanned facial data and photo images. It is composed of 3-dimensional texture mapping functions, a facial definition parameter input tool, and 3-dimensional facial prediction algorithms. With the texture mapping functions, we can generate a new model of a given face at a specified age using a scanned facial model and photo images. The texture mapping is done using three photo images - a front and two side images of a face. The facial definition parameter input tool is a user interface necessary for texture mapping and used for matching facial feature points between photo images and a 3D scanned facial model in order to obtain material values in high resolution. We have calculated material values for future facial models and predicted future facial models in high resolution with a statistical analysis using 100 scanned facial models.