• 제목/요약/키워드: masticatory force

검색결과 97건 처리시간 0.021초

Implant overdenture using milled bar and attachment in partially edentulous mandible: a case report (하악 부분 무치악 환자에서 Milled Bar와 부착장치를 이용한 임플란트 피개의치 수복 증례)

  • Kim, Min-Jung;Huh, Jung-Bo;Jeong, Chang-Mo;Yun, Mi-Jung;Lee, So-Hyoun;Jo, Yong-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제60권1호
    • /
    • pp.71-79
    • /
    • 2022
  • Excessive crown height space increases can cause crestal bone loss and screw loosening after prosthesis is placed. Milled bar and implant overdenture can be used as a treatment method for partially edentulous patients who have severe alveolar bone loss and excessive crown height space. Milled bar can provide primary splinting effect and stability between implants. Also, milled bar with additional retention device such as Advanced Dental Device-Treatment Of Choice (ADD-TOC) and magnet can provide additional retention force for implant overdenture. In this case, the patient has a partially edentulous mandible that has severe alveolar bone loss and multiple number of teeth loss after excision due to leiomyosarcoma. Because of the long-term loss of mandibular molars, the opposing teeth were extruded. Maxillary left molars were corrected to the occlusal plane through molar intrusion, and mandibular left molar region were treated with implant overdenture, using milled bar with ADD-TOC and magnet after implant placement. The clinical result was satisfactory on the aspect of esthetic and masticatory function.

Neutral zone and alveolar relation consideration for fabricating complete denture in a patient with severe alveolar bone resorption: a case report (치조제 흡수가 심한 환자에서 중립대 및 치조제 관계를 고려한 총의치 수복 증례)

  • Hyung-Jun Kim;Woo-hyung Jang;Chan Park;Kwi-dug Yun;Hyun-Pil Lim;Sang-Won Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제39권4호
    • /
    • pp.214-221
    • /
    • 2023
  • In order to fabricate stable dentures in patients with severe resorption of residual ridges, various factors must be considered. One of them is the neutral zone, which is defined as the potential region in which the pressure of the tongue outward in the oral cavity and the pressure of the cheeks and lips directed inward from the outside of the oral cavity equalize during functioning. In patients with severe ridge resorption, if the teeth are usually arranged above the residual ridge, the teeth are located on the lingual side rather than the original position. Therefore, the functional space of the tongue is invaded, the tongue is positioned backward, and the sealing of the lingual border is broken, which acts as a factor reducing the maintenance of denture. In addition, it is also important for the stability of dentures to assume an interalveolar crest line connecting the maxillary and mandibular ridge crests, and to arrange the maxillary and mandibular artificial teeth to match the masticatory force to the interalveolar crest line. Therefore, good clinical results were obtained by fabricating dentures for the patient with poor alveolar residual ridge using neutral zone impression and ridge relationship analysis.

ROOT RESORPTION OF PRIMARY TEETH WITHOUT PERMANENT SUCCESSORS (계승영구치가 선천적 결손된 유치의 치근 흡수)

  • Lee, Jung-Eun;Lee, Jae-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Song, Je-Seon;Son, Heung-Kyu;Choi, Byung-Jai
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • 제36권4호
    • /
    • pp.625-630
    • /
    • 2009
  • Root resorption of primary teeth usually occurs as the succeeding permanent teeth erupt, which induces differentiation of the hemopoietic cells into osteoclasts. Their root resorption pattern reflects the eruption path of the succeeding permanent teeth, and eventually the primary teeth shed as their succeeding permanent teeth erupt. Even when a permanent tooth germ is congenitally missing, root resorption of the corresponding primary tooth may still occur due to various factors, such as inflammation, traumatic occlusal force, and weakness of periodontium etc. Such congenital missing of permanent teeth is a commonly observed phenomenon in human be ing, and it often accompanies delayed retention of primary teeth. The etiologic factors for congenital missing in elude not only systemic diseases, but also local factors and human evolution process. In the radiographs of the cases in this report, the primary teeth without succeeding permanent teeth show pathologic root resorption. Root resorption progressed about 1/2~3/4 of the roots, and the surfaces of the resorption area were irregular. Considering high susceptibility of the periodontal ligament of primary teeth to root resorption, pathologic root resorption of primary teeth with delayed retention can be explained by the increased masticatory muscle force and abnormal occlusion developed during the mixed dentition. When the primary teeth without succeeding permanent teeth are lost, decision for space maintenance is required and long-term treatment plan for further prosthetic or orthodontic treatment should be establsihed.

  • PDF

Stress distribution of molars restored with minimal invasive and conventional technique: a 3-D finite element analysis (최소 침습적 충진 및 통상적 인레이 법으로 수복한 대구치의 응력 분포: 3-D 유한 요소 해석)

  • Yang, Sunmi;Kim, Seon-mi;Choi, Namki;Kim, Jae-hwan;Yang, Sung-Pyo;Yang, Hongso
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제34권4호
    • /
    • pp.297-305
    • /
    • 2018
  • Purpose: This study aimed to analyze stress distribution and maximum von Mises stress generated in intracoronal restorations and in tooth structures of mandibular molars with various types of cavity designs and materials. Materials and Methods: Three-dimensional solid models of mandible molar such as O inlay cavity with composite and gold (OR-C, OG-C), MO inlay cavity with composite and gold (MR-C, MG-C), and minimal invasive cavity on occlusal and proximal surfaces (OR-M, MR-M) were designed. To simulate masticatory force, static axial load with total force of 200 N was applied on the tooth at 10 occlusal contact points. A finite element analysis was performed to predict stress distribution generated by occlusal loading. Results: Restorations with minimal cavity design generated significantly lower values of von Mises stress (OR-M model: 26.8 MPa; MR-M model: 72.7 MPa) compared to those with conventional cavity design (341.9 MPa to 397.2 MPa). In tooth structure, magnitudes of maximum von Mises stresses were similar among models with conventional design (372.8 - 412.9 MPa) and models with minimal cavity design (361.1 - 384.4 MPa). Conclusion: Minimal invasive models generated smaller maximum von Mises stresses within restorations. Within the enamel, similar maximum von Mises stresses were observed for models with minimal cavity design and those with conventional design.

A COMPARISON OF FRACTURE STRENGTHS OF PORCELAIN-FUSED-TO-TITANIUM CROWN AMONG TITANIUM SURFACE COATING TREATMENTS (타이타늄 표면 코팅 처리에 따른 타이타늄도재관의 파절강도 비교)

  • Kim, Ji-Hye;Park, Sang-Won;Vang, Mong-Sook;Yang, Hong-So;Park, Ha-Ok;Lim, Hyun-Pil;Oh, Gye-Jeong;Kim, Hyun-Seung;Lee, Kwang-Min;Lee, Kyung-Ku
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제45권2호
    • /
    • pp.203-215
    • /
    • 2007
  • Statement of problem: Titanium and its alloy, with their excellent bio-compatibility and above average resistance to corrosion, have been widely used in the field of dentistry. However, the excessive oxidization of titanium which occurs during the process of firing on porcelain makes the bonding of titanium and porcelain more difficult than that of the conventional metal-porcelain bonding. To solve this problem related to titanium-porcelain bonding, several methods which modify the surfaces, coat the surfaces of titanium with various pure metals and ceramics, to enable the porcelain adhesive by limiting the diffusion of oxygen and forming the adhesive oxides surfaces, have been investigated. Purpose: The purpose of this study was to know whether the titanium-porcelain bonding strength could be enhanced by treating the titanium surface with gold and TiN followed by fabrication of clinically applicable porcelain-fused-to-titanium crown Material and method: The porcelain-fused-to-titanium crown was fabricated after sandblasting the surface of the casting titanium coping with $Al_2O_3$ and treating the surface with gold and TiN coating followed by condensation and firing of ultra-low fusing porcelain. To compare with porcelain-fused-to-titanium crowns, porcelain-fused-to-gold crowns were fabricated and used as control groups. The bonding strengths of porcelain-fused-to-gold crowns and porcelain-fused-totitanium crowns were set for comparison when the porcelain was fractured on purpose to get the experimental value of fracture strength. Then, the surface were examined by SEM and each fracturing pattern were compared with each other Result:Those results are as follows. 1. The highest value of fracture strength of porcelain-fused-to-titanium crowns was in the order of group with gold coating, group with TiN coating, group with $Al_2O_3$ sandblasting. No statistically significant difference was found among the three (P>.05). 2. The porcelain-fused-to-gold crowns showed the highest value in bonding strength. The bonding strength of crowns porcelain-fused-to-titanium crowns of rest groups showed bonding strength reaching only 85%-94% of that of PFG, though simple comparision seemed unacceptable due to the difference in materials used. 3. The fracturing patterns between metal and porcelain showed mixed type of failure behavior including cohesive failure and adhesive failure as a similar patterns by examination with the naked eye and SEM. But porcelain-fused-to-gold crowns showed high incidence of adhesive failure and porcelain-fused-to-titanium crowns showed high incidence of cohesive failure. Conclusion: Above results proved that when fabricating porcelain-fused-to-titanium crowns, treating casting titanium surface with gold or TiN was able to enhance the bonding strength between titanium and porcelain. Mean value of masticatory force was found to showed clinically acceptable values in porcelain bonding strength in all three groups. However, more experimental studies and evaluations should be done in order to get better porcelain bonding strength and various surface coating methods that can be applied on titanium surface with ease.

Removable implant-supported partial denture using milled bar with Locator® attachments in a cleft lip & palate patient: A clinical report (구순구개열 환자에서 Locator® 유지장치가 장착된 milled titanium bar를 이용한 가철성 임플란트 피개 국소의치의 보철수복증례)

  • Yang, Sang-Hyun;Kim, Kyoung-A;Kim, Ja-Yeong;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제53권3호
    • /
    • pp.207-214
    • /
    • 2015
  • Due to the limitations of conventional removable partial denture prostheses to treat a cleft lip & palate patient who shows scar tissue on upper lip, excessive absorption of the maxillary residual alveolar ridge, and class III malocclusion with narrow palate and undergrowth of the maxilla, 4 implants were placed on the maxillary edentulous region and a maxillary removable implant-supported partial denture was planned using a CAD/CAM milled titanium bar. Unlike metal or gold casting technique which has shrinkage after the molding, CAD/CAM milled titanium bar is highly-precise, economical and lightweight. In practice, however, it is very hard to obtain accurate friction-fit from the milled bar and reduction in retention can occur due to repetitive insertion and removal of the denture. Various auxiliary retention systems (e.g. $ERA^{(R)}$, $CEKA^{(R)}$, magnetics, $Locator^{(R)}$ attachment), in order to deal with these problems, can be used to obtain additional retention, cost-effectiveness and ease of replacement. Out of diverse auxiliary attachments, $Locator^{(R)}$ has characteristics that are dual retentive, minimal in vertical height and convenient of attachment replacement. Drill and tapping method is simple and the replacement of the metal female part of $Locator^{(R)}$ attachment is convenient. In this case, the $Locator^{(R)}$ attachment is connected to the milled titanium bar fabricated by CAD/CAM, using the drill and tapping technique. Afterward, screw holes were formed and 3 $Locator^{(R)}$ attachments were secured with 20 Ncm holding force for additional retention. Following this procedure, satisfactory results were obtained in terms of aesthetic facial form, masticatory function and denture retention, and I hereby report this case.

3-D Finite element stress analysis in screw-type, cement-type, and combined-type implant fixed partial denture designs (임플란트 상부보철물의 유지형태에 따른 3차원 유한요소 응력분석)

  • Lee, Sung-Chun;Kim, Seok-Gyu
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제47권4호
    • /
    • pp.365-375
    • /
    • 2009
  • Statement of problems: Stress analysis on implant components of the combined screw- and cement-retained implant prosthesis has not investigated yet. Purpose: The purpose of this study was to assess the load distribution characteristics of implant prostheses with the different prosthodontic retention types, such as cement-type, screw-type and combined type by using 3-dimensional finite element analysis. Material and methods: A 3-dimensional finite element model was created in which two SS II implants (Osstem Co. Ltd.) were placed in the areas of the first premolar and the first molar in the mandible, and three-unit fixed partial dentures with four different retention types were fabricated on the two SS II implants. Model 1 was a cement-retained implant restoration made on two cement-retained type abutments (Comocta abutment; Osstem Co. Ltd.), and Model 2 was a screw-retained implant restoration made on the screw-retained type abutments (Octa abutment; Osstem Co. Ltd.). Model 3 was a combined type implant restoration made on the cement-retained type abutment (Comocta abutment) for the first molar and the screw-retained type abutment (Octa abutment) for the first premolar. Lastly, Model 4 was a combined type implant restoration made on the screw-retained type abutment (Octa abutment) for the first molar and the cement-retained type abutment (Comocta abutment) for the first premolar. Average masticatory force was applied on the central fossa in a vertical direction, and on the buccal cusp in a vertical and oblique direction for each model. Von-Mises stress patterns on alveolar bone, implant body, abutment, abutment screw, and prosthetic screw around implant prostheses were evaluated through 3-dimensional finite element analysis. Results: Model 2 showed the lowest von Mises stress. In all models, the von Mises stress distribution of cortical bone, cancellous bone and implant body showed the similar pattern. Regardless of loading conditions and type of abutment system, the stress of bone was concentrated on the cortical bone. The von-Mises stress on abutment, abutment screw, and prosthetic screw showed the lower values for the screw-retained type abutment than for the cement-retained type abutment regardless of the model type. There was little reciprocal effect of the abutment system between the molar and the premolar position. For all models, buccal cusp oblique loading caused the largest stress, followed by buccal cusp vertical loading and center vertical loading. Conclusion: Within the limitation of the FEA study, the combined type implant prosthesis did not demonstrate more stress around implant components than the cement type implant prosthesis. Under the assumption of ideal passive fit, the screw-type implant prosthesis showed the east stress around implant components.