• 제목/요약/키워드: mass size

검색결과 2,533건 처리시간 0.035초

The Importance of Dry Deposition : Dry Deposition Fluxes of Heavy Metals In Seoul, Korea During Yellow-Sand Events

  • Yi, Seung-Muk
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2003년도 Challenges and Achievements in Environmental Health
    • /
    • pp.76-85
    • /
    • 2003
  • Mass and elemental dry deposition fluxes and ambient particle size distributions were measured using dry deposition plates and a cascade impactor, from March to November 1998 in Seoul, Korea. During the spring sampling period several yellow sand events characterized by long range transport from China and Mongolia impacted the area. During these events the mass fluxes were statistically the same as during springtime non-yellow-sand events. However, most elemental fluxes were higher. In general, the flux ratios of both crustal (Al, Ca, Mn) and anthropogenic elements (Ni, Pb) to total mass measured during the daytime yellow-sand events were substantially higher than those measured in spring daytime during non-yellow-sand time periods. During all seasons the average measured daytime fluxes were about two times higher than at nighttime. The flux of primarily anthropogenic metals (Cu, Ni, Pb, Zn) and Mn was on average one to two orders of magnitude lower than the flux of the crustal metals Al and Ca. As is typically found two modes, fine (0.1∼l.0 $\mu\textrm{m}$) and coarse (1.0∼10.0 $\mu\textrm{m}$) were present in the measured size distributions (<10 $\mu\textrm{m}$). The particles in the coarse mode constitute a major portion of the measured mass size distribution during the yellow-sand events possibly due to the long-range transport of those particles from China.

  • PDF

What determines the sizes of red early-type galaxies?

  • 이준협
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.77.1-77.1
    • /
    • 2011
  • The sizes of galaxies are correlated with their masses or luminosities, which is known as the 'mass-size relation' or 'luminosity-size relation'. Those relations show scatters in the sense that the sizes of galaxies range somewhat widely at given mass or luminosity, which is largely affected by the morphologies or colors of the sample galaxies. However, the scatters of the relations are still large even when the galaxy sample is limited to red early-type galaxies: at fixed mass or luminosity, the largest red early-type galaxies are larger than the smallest red early-type galaxies by a factor of 4 - 5. This is a progress report of a study on what determines the sizes of red early-type galaxies. We investigate how the sizes of red early-type galaxies depend on several quantities of them, such as color, color gradient, axis ratio, local number density and mass-to-light ratio. The physical implication of those preliminary results is discussed.

  • PDF

일부 분진 작업장에서의 공기중 분진 입경분포 (A Survey of Particulate Size Distribution in Work Environment)

  • 김영식;이병인;홍성철
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.22-26
    • /
    • 1991
  • Authors investigated the particulate size distribution in work environment of Banwol and Changwon industrial complex. Size distributions of particles exposured to workers in welding and in grinding process were evaluated by ambient cascade impactors. Respirable matter fractions were calculated from the size distribution data by the respirable particle mass of the ACGIH criteria.

  • PDF

제주지역 PM10의 수농도 및 질량농도와 원소성분 조성 특성 (Characteristics of the Number and the Mass Concentrations and the Elemental Compositions of PM10 in Jeju Area)

  • 강창희;허철구
    • 한국환경과학회지
    • /
    • 제23권3호
    • /
    • pp.447-457
    • /
    • 2014
  • The number concentrations, the mass concentrations and the elemental concentrations of $PM_{10}$ have measured at Gosan site in Jeju, Korea, from March 2010 to December 2010. And the correlation and the factor analysis for the number, the mass and the elemental concentrations of $PM_{10}$ are performed to identify their relationships and sources. The average $PM_{10}$ number concentration is observed $246\;particles/cm^3$($35.7{\sim}1,017\;particles/cm^3$) and the average $PM_{10}$ mass concentration is shown $50.1{\mu}g/m^3$($16.7{\sim}441.4{\mu}g/m^3$) during this experimental period. The number concentrations are significantly decreased with increasing particle size, hence the concentrations for the smaller particles less than $2.5{\mu}m$($PM_{2.5}$) are contributed 99.6% to the total $PM_{10}$ number concentrations. The highest concentration of the 20 elements in $PM_{10}$ determined in this study is shown by S with a mean value of $1,497ng/m^3$ and the lowest concentration of them is found by Cd with a mean value of $0.57ng/m^3$. The elements in $PM_{10}$ are evidently classified into two group based on their concentrations: In group 1, including S>Na>Al>Fe>Ca>Mg>K, the elemental mean concentrations are higher than several hundred $ng/m^3$, on the other hand, the concentrations are lower than several ten $ng/m^3$ in group 2, including Zn>Mn>Ni>Ti>Cr>Co>Cu>Mo>Sr>Ba>V>Cd. The size-separated number concentrations are shown positively correlated with the mass concentrations in overall size ranges, although their correlation coefficients, which are monotonously increased or decreased with size range, are not high. The concentrations of the elements in group 1 are shown highly correlated with the mass concentrations, but the concentrations in group 2 are shown hardly correlated with the mass concentrations. The elements originated from natural sources have been predominantly related to the mass concentrations while the elements from anthropogenic sources have mainly affected on the number concentrations of $PM_{10}$.

새만금호 3차원 수리.수질모델(EFDC)의 수치격자 민감도 분석 (A Sensitivity Analysis on Numerical Grid Size of a Three-Dimensional Hydrodynamic and Water Quality Model (EFDC) for the Saemangeum Reservoir)

  • 전지혜;정세웅
    • 한국물환경학회지
    • /
    • 제28권1호
    • /
    • pp.26-37
    • /
    • 2012
  • Multi-dimensional hydrodynamic and water quality models are widely used to simulate the physical and biogeochemical processes in the surface water systems such as reservoirs and estuaries. Most of the models have adopted the Eulerian grid modeling framework, mainly because it can reasonably simulate physical dynamics and chemical species concentrations throughout the entire model domain. Determining the optimum grid cell size is important when using the Eulerian grid-based three-dimensional water quality models because the characteristics of species are assumed uniform in each of the grid cells and chemical species are represented by concentration (mass per volume). The objective of this study was to examine the effect of grid-size of a three dimensional hydrodynamic and water quality model (EFDC) on hydrodynamics and mass transport in the Saemangeum Reservoir. Three grid resolutions, respectively representing coarse (CG), medium (MG), and fine (FG) grid cell sizes, were used for a sensitivity analysis. The simulation results of numerical tracer showed that the grid resolution affects on the flow path, mass transport, and mixing zone of upstream inflow, and results in a bias of temporal and spatial distribution of the tracer. With the CG, in particular, the model overestimates diffusion in the mixing zone, and fails to identify the gradient of concentrations between the inflow and the ambient water.

수원지역 입자상 오염물질의 오염원 기여도의 추정 (Estimation of Source Contribution for Ambient Particulate Matters in Suwon Area)

  • 이태정;김동술
    • 한국대기환경학회지
    • /
    • 제13권4호
    • /
    • pp.285-296
    • /
    • 1997
  • The suspended particulate matters had been collected on quartz fiber fiters by a cascade impactor having 9 size stages for 4 years (Sep. 1991 to Dec. 1995) in Kyung Hee University-Suwon Campus. Membrane filters were used to collected the particulate matters on each stage. The weight concentration on each stage was obtained by a microbalance and further chemical element levels were determined by an x-ray fluorescence system. Based on these chemical information, our study focused on applying the target transformation factor analysis (TTFA), a receptor model, to identify aerosol sources and to apportion quantitatively their mass contribution. There are total of 63 ambient data sets. Each data set consists of the 8 size-ranged subdata sets characterized by 16 elemental variables. By the results, four to five sources were extracted from each size range and some sources reappeared in other size ranges. Then total of 8 source profiles were statistically generated from all the ranges, such as oil burning source, soil source, field burning source, gasoline related source, coal burning source, marine source, glass related source, and unknown sources. Apportioning aerosol mass to each source was intensively examined by investigating emission inventories near the study area. The results showed that soil particle source was the most significant contributor. However, coal and oil burning sources were the major anthropogenic ones. The study finally proposed some air quality control strategies to achieve the clean air quality in Suwon area.

  • PDF

Ultrasonographic assessment of transitional cell carcinoma of the urinary bladder in dogs: a perspective of tumor size change

  • Kim, Seungji;Kim, Yongbaek;Kim, Wanhee;Choi, Mincheol;Yoon, Junghee
    • 대한수의학회지
    • /
    • 제57권3호
    • /
    • pp.205-208
    • /
    • 2017
  • Study purposes were to evaluate ultrasonographic characteristics of transitional cell carcinoma (TCC) and quantitate bladder tumor size in dogs. Heterogeneous mass, wall involvement, and broad-based attachment were significantly associated with TCC, but not prominently the trigone region. Mass size evaluation revealed a significant correlation between progressive disease (PD) in TCC patients with piroxicam therapy. Largest diameter of target lesion/body weight (cm/kg) ratio showed a high mean value in PD. A value > 0.3 was associated with PD with 83% sensitivity and 66% specificity. The results suggest that ultrasonography can provide evidence for diagnosing and predicting a prognosis for TCC.

소형 코리올리 질량 유량계의 개발 (Development of Small Size Coriolis Mass Flowmeter)

  • 임기원;지정근
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.497-504
    • /
    • 2006
  • A Coriolis mass flowmeter(CMF), which has U-Shaped unique measurins tube was developed fo. direct mass flow measurement. In order to convert the time difference between two measuring tubes motion into mass flowrate and flow quantity, a signal processing circuit, as a part of CMF, was also developed. The CMF was designed as the 15 mm nominal diameter of pipe connection and the 8 mm stainless steel(sus 316) pipe was used for measuring tube. To maximize the flow signal(time difference) from the measuring tubes, the natural frequency of measuring tube was adjusted as 220 Hz, which is same as the frequency of exciter. The maximum displacement at the end of the measuring tube was measured as 0.05 mm and the maximum time difference between two measuring tubes was observed as $20{\mu}s$, which was proper for discrimination and measuring range of CMF. The developed CMF was tested against the gravimetric flowmeter calibrator in the range of 3 kg/min and 30 kg/min. The results showed that the CMF has good linearity and repeatability in the tested flow range. Large size of CMF base on the current study experience will be developed.

제주도 해안가에서 측정된 에어로졸의 성분별 입경분포 특성 (Size Distribution of Ambient Aerosol Measured at a Coastal Site in Jeju Island)

  • 이기호;양희준;허철구
    • 한국환경과학회지
    • /
    • 제12권10호
    • /
    • pp.1043-1054
    • /
    • 2003
  • During the period from April to September 2002, the size distributions of ambient aerosol were measured at the coastal site at Hamduk in Jeju Island. Na$\^$+/, K$\^$+/, Mg$\^$2+/, Ca$\^$2+/and Cl$\^$-/ exhibited mostly a bimodal coarse mode size distribution, while ammonium and sulfate were mainly in the fine size range, with maximum at around 0.54$\mu\textrm{m}$. The average molar concentration ratio of ammonium to sulfate for fine particles was equal to 2.0${\pm}$0.9. Nitrate was evenly found in both the coarse and fine modes. Elements like Al, Fe, Cu, Mg, Na, Ti, Sr and Mn were dominant in coarse particles, with the maximum at around 5.25$\mu\textrm{m}$. S and Pb were mainly in the submicrometer size range. Other elements with a fine and coarse modes were V, Ni, Cu, Ba and Mo. The patterns of the size distributions of trace elements measured at the downtown in Jeju City were very similar to those at the coastal site in Hamduk. However, the amplitude of size fractional concentrations at Jeju City was narrower than that at Hamduk. While the mass median diameters for the chemical species originated from the natural origin such as marine and crust were relatively large, those for ammonium, sulfate, S and Pb were very small.

출산 전후기에 진단된 무증상 부신 종괴의 치료 (Treatment of the Perinatally Diagnosed Asymptomatic Adrenal Gland Mass)

  • 황승현;임준섭;오정탁;김명준;한석주;최승훈
    • Advances in pediatric surgery
    • /
    • 제10권2호
    • /
    • pp.107-111
    • /
    • 2004
  • Recently, the incidence of perinatally detected asymptomatic adrenal gland masses has increased because of widespread use of radiological diagnostic tools. However, optimal treatment of these masses has not been determined. The aim of this study is to elucidate the treatment guideline of perinatally diagnosed adrenal gland masses. The authors retrospectively reviewed the medical records of the 11 patients with asymptomatic adrenal gland mass, detected perinatally, between 1999 and 2004. Six cases were detected by prenatal ultrasound and 5 cases were incidentally detected by postnatal ultrasound. Six patients (surgery group) underwent mass excision. The pathologic diagnoses were neuroblastoma (n=4), adrenocortical adenoma (n=1) and adrenal pseudocyst (n=1). The indications for operation were suspicion of neuroblastoma (n=5) or absence of size decrease during observation (n=1). Three of the 5 suspicious cases of neuroblastoma and one case under observation were proven to be neuroblastoma. There was no surgical complication in the urgery group. All neuroblastoma patients have been well during the follow up period ($24.4{\pm}14.4$ month) without evidence of recurrence. Five cases (observation group) were closely observed because of the benign possibility or size decrease in follow up ultrasound. During the observation period ($39{\pm}21$ week), 4 cases showed complete spontaneous resolution and 1 case showed markedly decreased size of the mass but could not be followed up completely. Surgical resection of the perinatally diagnosed asymptomatic adrenal gland mass is a safe treatment method especially in case of suspicion of neuroblastoma, but closed observation can be applied.

  • PDF