• 제목/요약/키워드: mass margins

검색결과 59건 처리시간 0.024초

Ultrasonographic Features of Triple-Negative Breast Cancer: a Comparison with Other Breast Cancer Subtypes

  • Yang, Qi;Liu, Hong-Yan;Liu, Dan;Song, Yan-Qiu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3229-3232
    • /
    • 2015
  • Background: Triple-negative breast cancer (TNBC) is known to be associated with aggressive biologic features and a poor clinical outcome. Therefore, early detection of TNBC without missed diagnosis is a requirement to improve prognosis. Preoperative ultrasound features of TNBC may potentially assist in early diagnosis as characteristics of disease. Purpose: To retrospectively evaluate the sonographic features of TNBC compared to ER (+) cancers which include HER(-) and HER2 (+), and HER2 (+) cancers which are ER (-). Materials and Methods: From June 2012 through June 2014, sonographic features of 321 surgically confirmed ER (+) cancers (n=214), HER2 (+) cancers (n=66), and TNBC (n=41) were retrospectively reviewed by two ultrasound specialists in consensus. The preoperative ultrasound and clinicopathological features were compared between the three subtypes. In addition, all cases were analyzed using morphologic criteria of the ACR BI-RADS lexicon. Results: Ultrasonographically, TNBC presented as microlobulated nodules without microcalcification (p=0.034). A lower incidence of ductal carcinoma in situ (p<0.001), invasive tumor size that is>2 cm (p=0.011) and BI-RADS category 4 (p<0.001) were significantly associated with TNBC. With regard to morphologic features of 41 TNBC cases, ultrasonographically were most likely to be masses with irregular (70.7%) microlobulated shape (48.8%), be circumscribed (17.1%) or have indistinct margins (17.1%) and parallel orientation (68.9%). Especially TNBC microlobulated mass margins were more more frequent than with ER (+) (2.0%) and HER2 (+) (4.8%) cancers. Conclusions: TNBC have specific characteristic in sonograms. Ultrasonography may be useful to avoid missed diagnosis and false-negative cases of TNBC.

정지궤도위성 광학탑재체 복사 열제어 시스템 개념 설계 (A CONCEPTUAL DESIGN OF RADIATIVE THERMAL CONTROL SYSTEM IN A GEOSTATIONARY SATELLITE OPTICAL PAYLOAD)

  • 김정훈;전형열
    • 한국전산유체공학회지
    • /
    • 제12권3호
    • /
    • pp.62-68
    • /
    • 2007
  • A conceptual thermal design is performed for the optical payload system of a geostationary satellite. The optical payload considered in this paper is GOCI(Geostationary Ocean Color Imager) of COMS of Korea. The radiative thermal control system is employed in order to expect a small thermal gradient in the telescope structure of GOCl. Two design margins are applied to the dedicated radiator dimensioning, and three kinds of configuration to the heater power sizing. A Monte-Carlo ray tracing method and a network analysis method are utilized to calculate radiative couplings and thermal responses respectively. At the level of conceptual design, sizing thresholds are presented for the radiator and heater on the purpose of determining the mass and power budget of the spacecraft.

기관에 발생한 Adenoid Cystic Carcinoma 치험 1예 (A case of cystic carcinoma of the trachea)

  • 김송명
    • Journal of Chest Surgery
    • /
    • 제16권1호
    • /
    • pp.153-160
    • /
    • 1983
  • Adenoid cystic carcinoma is a rare primary tracheal tumor and this tumor behave slow growth, low-grade ma!ignancy, locally invasion and long-term host survival. Operation with the primary goal of complete excision is the treatment of choice but this tumor require excessive margins at surgical removal because of locally invasive cancer. A 45-years-old male patient had complained paroxysmal coughing from 1 year ago prior to admission and was diagnosed pre-operatively as endotracheal adenoma. He had been treated by operation, and combined with radiotherapy by 4 MeV. Lineal Accelerator. The tracheal mass was removed by tracheo-bronchotomy transpleurally and right total pneumonectomy was performed. There was post-operative course uneventfully and no post-operative complication. The patient Is free from cancer until post-operative 1 year clinically and alive with good healthy.

  • PDF

압력섭동과 연관된 연소응답모델에 기초한 고주파 연소불안정의 이론-수치적 고찰 (Hybridal Analysis of High-Frequency Combustion Instability with Pressure-Coupled Combustion Response Model)

  • 윤웅섭;이길용
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.253-257
    • /
    • 2003
  • Theoretical-numerical analysis of wave instability is conducted with parametric response function model. Fluctuating instantaneous mass evaporation rate functionally coupled with pressure perturbations with phase lag is assumed to examine the validity of the method. With sufficiently large amplitude and less phase lag to perturbation, combustion response is resonant to pressure waves, unstable waves are amplified, and the system is driven to instability. Magnitude of response is a crucial instability parameter in the determination of a stability margins and makes a critical change of balancing conditions between the amplifying and damping acoustic energies. In the phase regime the unstable waves are amplified, whereas, the acoustic waves are attenuated in the out-of-phase regime. In the intermediate regime, no distinct tendency of unstable waves was determined.

  • PDF

Differences Between Breast Cancer Patients Younger and Older than 40 Years: Mammographic Findings

  • Zhao, Yu-Mei;Wang, Jian-Tao;Liu, Jing;Wang, Ju;Wang, Hong-Li;Liu, Pei-Fang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권12호
    • /
    • pp.4929-4932
    • /
    • 2014
  • Objective: To compare the mammogarphic appearance between breast cancer patients aged <40 and ${\geq}40$ years. Methods: Needle localization and biopsy of suspicious mammographic lesions identified 1,959 breast carcinomas in a single institution from Jun 2012 to Apr 2013. According to the age, we divided patients into two groups: <40 and ${\geq}40$ years old, and analyzed mammographic appearance separately. Results: Young patients had 44.2% foci with calcification, but old patients only had 39.4% (P<0.001). In younger group, the ratios of cases according to mass density were 41.8% or higher, 58.2% equivalent and lower. In older group, the ratios were 55.5 % and 44.5%, respectively. There were statistical differences between high density and others (P<0.05). The ratios of cases according to mass margin were 13.9% circumscribed and microlobulated, 86.1% indistinct and spiculated in the younger group, as compared to 6.5% and 93.5%, respectively, in the older group (P<0.05). Conclusions: Mammographic findings differ between young and old patients with breast cancer, for example regarding mass density, mass margin and microcalcification ratios.

$\mu$-합성법을 이용한 사장교의 지진응답 제어 (Seismic Response Control of a Cable-Stayed Bridge using a $\mu$-Synthesis Method)

  • 박규식;정형조;윤우현;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.476-483
    • /
    • 2004
  • This paper presents a hybrid system combining lead rubber bearings and hydraulic actuators controlled by a μ-synthesis method for seismic response control of a cable-stayed bridge. A hybrid system could alleviate some of restrictions and limitations that exist when each system is acting alone because multiple control devices are operating. Therefore, the overall control performance of a hybrid system may be improved compared to each system, however the overall system robustness may be negatively impacted by active device in the hybrid system or active controller may cause instability due to small margins. Therefore, a f-synthesis method that guarantees the robust performance is considered to enhance the possibility of real applications of the control system. The control performances of the proposed control system are compared with those of passive, active, semiactive control systems and hybrid system controlled by LQG algorithm and an extensive robust analysis with respect to stiffness and mass matrices perturbation and time delay of actuator is performed. Numerical simulation results show that the control performance of the proposed control system is superior to that of the passive system and slightly better than that of the active and semiactive systems and two hybrid systems show similar control performances. Furthermore, the hybrid system controlled by a μ-synthesis method shows the good robustness without loss of control performances. Therefore, the proposed control system could effectively be used to seismically excited cable-stayed bridge which contains many uncertainties.

  • PDF

다단 압축기의 단 매칭 기법에 관한 연구 (A Study on The Stage Matching of Multistage Compressor)

  • 최창호;김진한;김춘택;양수석;이대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.163-168
    • /
    • 2000
  • A method to search the design parameters for optimum stage matching has been used based on a 1-D mathematical model of a compressor, which uses the data obtained from the preliminary test to identify the design parameters. This methodology was applied with a two-stage axial compressor, which was originally designed for a helicopter gas turbine engine. After Identifying design parameters using preliminary test data, an optimization process has been employed to achieve the best matching between the stages (i.e., maximum efficiency of the compressor at its operation modes within a given range of the rotor speed under given restrictions for required stall margins and mass flow). 3-D flow calculations have been performed to confirm the usefulness of the corrections based on 1-D mathematical model. Calculational results agree well with the experimental data in view of the performance characteristics. Some promising results were produced through the methodology proposed in this paper in conjunction with flow calculations.

  • PDF

Evaluation of correlations for prediction of onset of heat transfer deterioration for vertically upward flow of supercritical water in pipe

  • Sahu, Suresh;Vaidya, Abhijeet M.
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1100-1108
    • /
    • 2021
  • Supercritical water has great potential as a coolant for nuclear reactor. Its use will lead to higher thermal efficiency of Rankine cycle. However, in certain conditions heat transfer may get deteriorated which may lead to undesirable high clad surface temperature. It is necessary to estimate the operating conditions in which heat transfer deterioration (HTD) will take place, so as to establish thermal margins for safe reactor operation. In the present work, the heat flux corresponding to onset of HTD for vertically upward flow of supercritical water in a pipe is obtained over a wide range of system parameters, namely pressure, mass flux, and pipe diameter. This is done by performing large number of simulations using an in-house CFD code, which is especially developed and validated for this purpose. The identification of HTD is based on observance of one or more peak/s in the computed wall temperature profile. The existing correlations for predicting the onset of HTD are compared against the results obtained by present simulations as well as available sets of experimental data. It is found that the prediction accuracy of the correlation proposed by Dongliang et al. is best among the existing correlations.

Platform development for multi-physics coupling and uncertainty analysis based on a unified framework

  • Guan-Hua Qian;Ren Li;Tao Yang;Xu Wang;Peng-Cheng Zhao;Ya-Nan Zhao;Tao Yu
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1791-1801
    • /
    • 2023
  • The multi-physics coupled methodologies that have been widely used to analyze the complex process occurring in nuclear reactors have also been used to the R&D of numerical reactors. The advancement in the field of computer technology has helped in the development of these methodologies. Herein, we report the integration of ADPRES code and RELAP5 code into the SALOME-ICoCo framework to form a multi-physics coupling platform. The platform exploits the supervisor architecture, serial mode, mesh one-to-one correspondence and explicit coupling methods during analysis, and the uncertainty analysis tool URANIE was used. The correctness of the platform was verified through the NEACRP-L-335 benchmark. The results obtained were in accordance with the reference values. The platform could be used to accurately determine the power peak. In addition, design margins could be gained post uncertainty analysis. The initial power, inlet coolant temperature and the mass flow of assembly property significantly influence reactor safety during the rod ejections accident (REA).

유방의 당원성 투명세포암종의 세침흡인 세포학적 소견 - 2예 보고 - (Fine Needle Aspiration Cytology of Glycogen-Rich Clear Cell Carcinoma of the Breast - A Report of 2 Cases -)

  • 김완섭;이원미;홍은경;박문향;이중달
    • 대한세포병리학회지
    • /
    • 제9권2호
    • /
    • pp.213-219
    • /
    • 1998
  • Glycogen-rich clear ceil carcinoma of the breast is an unusual variant of carcinoma with a recorded incidence of $1.4{\sim}3%$ of breast carcinomas. The cytologic characteristics have not been well described. We report two cases of glycogen-rich clear cell carcinoma with corresponding fine needle aspiration(FNA) cytologic findings and compare them to infiltrating ductal carcinoma and other clear ceil malignancies with a review of literature. One was a 62-year-old woman exhibiting a palpable mass of the right breast. The smears showed atypical tight cell clusters and individually scattered single cells containing leanly or clear abundant cytoplasm with well defined cytoplasmic margins. Mild to moderate nuclear pleomorphism and a prominent nucleolus were present. The other was a 42-year-old woman who was admitted with a right breast mass. The smears showed moderately cellular, tightly cohesive tumor cells. The cytoplasmic outline was generally well demarcated. The tumor cells Contained foamy to clear abundant cytoplasm with large and small vacuoles. The nuclear pleomorphism was marked. Both tumors resected by modified radical mastectomy, were diagnosed as glycogen-rich clear cell carcinoma. Histologically, the clear cell nature of tumor cells were not characteristic enough to predict this type of the tumor. Some cytologic features can be distinguished other clear cell breast cancer from glycogen-rich carcinoma. Recognition of these unusual patterns in a breast FNAC should raise the suspicion of a clear cell carcinoma including glycogen-rich subtype. Cytological localization of glycogen using PAS and D-PAS staining may permit the correct Identification and differential diagnosis of this tumor.

  • PDF