• 제목/요약/키워드: marine reactor

검색결과 110건 처리시간 0.028초

선박용수의 재사용에 관한 기초연구(II) -중공사모듈 UF MF 필터에 의한 선박폐수의 고도처리- (A basic study on the reuse of shipboard wastewater(II) -An advanced treatment of shipboard wastewater by Hollow fiber UF and MF filtration-)

  • 김인수;김억조;김동근;고성정;안종수
    • 해양환경안전학회지
    • /
    • 제4권1호
    • /
    • pp.49-56
    • /
    • 1998
  • The Microfiltration and Ultrafiltration were used to treat effluent of secondary municipal wastewater treatment system(Sequencing Batch Reactor). The cross-flow hollow fiber, UF 500,000(NMWC) and MF 0.65$\mu$ membrane were selected as suitable membrane. Short term and long term fouling effect were measured as a factor of flux decrease and the fouling removal effect of mixing air bubble in the penetrant was studied. The removal of anionic sulfactants before and after formation of micelle with several kinds of oil were checked. The test results show that removal of TOC was 70~80%, TN 28% and TP 16%. The decrease of flux due to fouling were 85%(UF) and 90%(MF) after running of 100hrs. The removal of anionic sulfactants were 60~70% notwithstanding micelle or not.

  • PDF

선박용수의 재사용에 관한 기초연구(I) -연속회분식 반응조를 이용한 선박폐수의 2차처리- (A basic study on the reuse of shipboard wastewater(I) - The secondary treatment of shipboard wastewater by Sequence Batch Reactor(SBR)-)

  • 김인수;김억조;김동근;고성정;안종수
    • 해양환경안전학회지
    • /
    • 제4권1호
    • /
    • pp.41-48
    • /
    • 1998
  • There are several serious problems in treating shipboard wastewater due to special environmental conditions of ship, such as confined space, rolling and pitching, change of temperature and so on. It was suggested that Sequence Batch Reator (SBR) process might be suitable for overcoming above problems in terms of small size, high capacity of treating wastewater and full automation. In this study the SBR process was used for the secondary treatment of shipboard wastewater. The average removal efficiency of DOC, nitrogen, phosphorus and surfactants(MBAS) were studied and the effects of various C/N ration on the efficiency of treatment were investgated. From the experimental results it was convinced that the SBR process would be able to be used as a suitable process for removing organic matters and nitrogen in reuse system of shipboard wastewater.

  • PDF

Removal of a High Load of Ammonia by a Marine Bacterium, Vibrio alginolyticus in Biofilter

  • Kim, Nam-Jin;Shoda, Makoto
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제7권5호
    • /
    • pp.316-322
    • /
    • 2002
  • A newly isolated heterotrophic marine bacterium, Vibrio alginolyticus, was used to remove a high load of ammonia gas under non-sterile condition. The cells were inoculated onto an inorganic packing material in a fixed-bed reactor (biofilter), and a high load of ammonia, in the range of ammonia gas concentration of 170 ppm to 880 ppm, was introduced continuously. Sucrose solution and 3% NaCl was supplied intermittently to supplement the carbon source and water to the biofilter. The average percentage of gas removed exceeded 85% for 107-day operation. The maximum removal capacity and the complete removal capacity were$19\;g-N\;kg^{-1}$ dry packing material $day^{-1}$ and $16\;g-N\;kg^{-1}$ dry packing material $day^{-1}$, respectively, which were about three times greater than those obtained in nitrifying sludge inoculated onto the same packing material. On day 82, the enhanced pressure drop was restored to the normal one by NaOH treatment, and efficient removal characteristics were later observed. During this operation, the non-sterile condition had no significantly adverse effect on the removability of ammonia by V. alginolyticus.

해양퇴적물에서 중금속 용출 차단 및 퇴적물 산소 요구량 감소를 위한 석회석, 제올라이트 및 폐콘크리트의 피복 소재로서 적용 (Application of Limestone, Zeolite, and Crushed Concrete as Capping Material for Interrupting Heavy Metal Release from Marine Sediments and Reducing Sediment Oxygen Demand)

  • 강구;박성직
    • 한국농공학회논문집
    • /
    • 제57권4호
    • /
    • pp.31-38
    • /
    • 2015
  • This study aims to assess the effectiveness of limestone, zeolite, and crushed concrete as capping material to block the release of heavy metals (As, Cu, Cr, Ni, and Pb) and reduce the sediment oxygen demand. The efficiency of limestone, zeolite, and crushed concrete was evaluated in a reactor in which a 1-cm thick layer of capping materials was placed on the sediments collected from Inchon north harbor. Dissolved oxygen concentration and heavy metal concentration in seawater above the uncapped sediments and capping material were monitored for 17 days. The sediment oxygen demand was in the following increasing order: crushed concrete ($288.37mg/m^2{\cdot}d$) < zeolite ($428.96mg/m^2{\cdot}d$) < limestone ($904.53mg/m^2{\cdot}d$) < uncapped ($981.34mg/m^2{\cdot}d$). The capping materials could reduce the sediment oxygen demand by blocking the release of biochemical matters consuming dissolved oxygen in seawater. It was also shown that zeolite and crushed concrete could effectively block the release of Cu, Ni, and Pb but those were not effective for the interruption of As and Cr release from marine contaminated sediments.

Purification and characterization of β-secretase inhibitory peptide from sea hare (Aplysia kurodai) by enzymatic hydrolysis

  • Lee, Jung Kwon;Kim, Sung Rae;Byun, Hee-Guk
    • Fisheries and Aquatic Sciences
    • /
    • 제21권5호
    • /
    • pp.13.1-13.8
    • /
    • 2018
  • Amyloid plaque, also called senile plaque, the product of aggregation of ${\beta}$-amyloid peptides ($A{\beta}$), is observed in brains of the patients with Alzheimer's disease (AD) and is one of the key factors in etiology of the disease. In this study, hydrolysates obtained from the sea hare (Aplysia kurodai) were investigated for ${\beta}$-secretase inhibitory peptide. The sea hare's muscle protein was hydrolyzed using six enzymes in a batch reactor. Trypsin hydrolysate had highest ${\beta}$-secretase inhibitory activity compared to the other hydrolysates. ${\beta}$-secretase inhibitory peptide was separated using Sephadex G-25 column chromatography and high-performance liquid chromatography on a C18 column. ${\beta}$-secretase inhibitory peptide was identified as eight amino acid residues of Val-Ala-Ala-Leu-Met-Leu-Phe-Asn by N-terminal amino acid sequence analysis. $IC_{50}$ value of purified ${\beta}$-secretase inhibitory peptide was $74.25{\mu}M$, and Lineweaver-Burk plots suggested that the peptide purified from sea hare muscle protein acts as a competitive inhibitor against ${\beta}$-secretase. Results of this study suggest that peptides derived from sea hare muscle may be beneficial as anti-dementia compounds in functional foods or as pharmaceuticals.

The Effect of Different Inflows on the Unsteady Hydrodynamic Characteristics of a Mixed Flow Pump

  • Yun, Long;Dezhong, Wang;Junlian, Yin;Youlin, Cai;Chao, Feng
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권2호
    • /
    • pp.138-145
    • /
    • 2017
  • The problem of non-uniform inflow exists in many practical engineering applications, such as the elbow suction pipe of waterjet pump and, the channel head of steam generator which is directly connect with reactor coolant pump. Generally, pumps are identical designs and are selected based on performance under uniform inflow with the straight pipe, but actually non-uniform suction flow is induced by upstream equipment. In this paper, CFD approach was employed to analyze unsteady hydrodynamic characteristics of reactor coolant pumps with different inflows. The Reynolds-averaged Naiver-Stokes equations with the $k-{\varepsilon}$ turbulence model were solved by the computational fluid dynamics software CFX to conduct the steady and unsteady numerical simulation. The numerical results of the straight pipe and channel head were validated with experimental data for the heads at different flow coefficients. In the nominal flow rate, the head of the pump with the channel head decreases by 1.19% when compared to the straight pipe. The complicated structure of channel head induces the inlet flow non-uniform. The non-uniformity of the inflow induces the difference of vorticity distribution at the outlet of the pump. The variation law of blade to blade velocity at different flow rate and the difference of blade to blade velocity with different inflow are researched. The effects of non-uniform inflow on radial forces are absolutely different from the uniform inflow. For the radial forces at the frequency $f_R$, the corresponding amplitude of channel head are higher than the straight pipe at $1.0{\Phi}_d$ and $1.2{\Phi}_d$ flow rates, and the corresponding amplitude of channel head are lower than the straight pipe at $0.8{\Phi}_d$ flow rates.

개구부에 삽입한 수직평판이 헬륨.공기치환류에 미치는 영향 (Effect of Partition within Opening on Helium-Air Exchange Flow)

  • Tae-il Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제27권6호
    • /
    • pp.797-805
    • /
    • 2003
  • This paper describes experimental investigations of helium-air exchange flow through single opening and partitioned opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with the opening, for partition ratios H_p/H$_1$$ in the range 0 to 1. where H_p$ and H$_1$ are partition length and height of the opening. respectively. In the case of H_p/H$_1$$ of 0, flow passages of upward flow of the helium and downward flow of the air within the opening are unseparated (bidirectional), and the two flows interfere within the opening. The unseparated flow increases strength of flow resistance and therefore, the exchange flow rate is minimum through range of the partition ratios. Two flow zones, i.e., separated (unidirectional) flow zone and unseparated (bidirectional) flow zone, exist with increasing the partition length. The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at H_p/H$_1$$ of 1. As a result of comparison of the exchange flow rates by changing the partition ratio, the fluids Interference in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

Application of cost-sensitive LSTM in water level prediction for nuclear reactor pressurizer

  • Zhang, Jin;Wang, Xiaolong;Zhao, Cheng;Bai, Wei;Shen, Jun;Li, Yang;Pan, Zhisong;Duan, Yexin
    • Nuclear Engineering and Technology
    • /
    • 제52권7호
    • /
    • pp.1429-1435
    • /
    • 2020
  • Applying an accurate parametric prediction model to identify abnormal or false pressurizer water levels (PWLs) is critical to the safe operation of marine pressurized water reactors (PWRs). Recently, deep-learning-based models have proved to be a powerful feature extractor to perform high-accuracy prediction. However, the effectiveness of models still suffers from two issues in PWL prediction: the correlations shifting over time between PWL and other feature parameters, and the example imbalance between fluctuation examples (minority) and stable examples (majority). To address these problems, we propose a cost-sensitive mechanism to facilitate the model to learn the feature representation of later examples and fluctuation examples. By weighting the standard mean square error loss with a cost-sensitive factor, we develop a Cost-Sensitive Long Short-Term Memory (CSLSTM) model to predict the PWL of PWRs. The overall performance of the CSLSTM is assessed by a variety of evaluation metrics with the experimental data collected from a marine PWR simulator. The comparisons with the Long Short-Term Memory (LSTM) model and the Support Vector Regression (SVR) model demonstrate the effectiveness of the CSLSTM.

환상유로에 있어서 수직고온관의 과도적 냉각과정에 관한 연구 (A study on the transient cooling process of a vertical-high temperature tube in an annular flow channel)

  • 정대인;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권2호
    • /
    • pp.156-164
    • /
    • 1986
  • In the case of boiling on high temperature wall, vapor film covers fully or parcially the surface. This phenomenon, film boiling or transition boiling, is very important in the surface heat treatment of metal, design of cryogenic heat exchanger and emergency cooling of nuclear reactor. Mainly supposed hydraulic-thermal accidents in nuclear reactor are LCCA (Loss of Coolant Accident) and PCM (Power-Cooling Mismatch). Recently, world-wide studies on reflooding of high temperature rod bundles after the occurrence of the above accidents focus attention on wall temperature history and required time in transient cooling process, wall superheat at rewet point, heat flux-wall superheat relationship beyond the transition boiling region, and two-phase flow state near the surface. It is considered that the further systematical study in this field will be in need in spite of the previous results in ref. (2), (3), (4). The paper is the study about the fast transient cooling process following the wall temperature excursion under the CHF (Critical Heat Flux) condition in a forced convective subcooled boiling system. The test section is a vertically arranged concentric annulus of 800 mm long and 10 mm hydraulic diameter. The inner tube, SUS 304 of 400 mm long, 8 mm I.D, and 7 mm O.D., is heated uniformly by the low voltage AC power. The wall temperature measurements were performed at the axial distance from the inlet of the heating tube, z=390 mm. 6 chromel- alumel thermocouples of 76 .mu.m were press fitted to the inner surface of the heating tube periphery. To investigate the heat transfer characteristics during the fast transient cooling process, the outer surface (fluid side) temperature and the surface heat flux are computed from the measured inner surface temperature history by means of a numerical method for inverse problems of transient heat conduction. Present cooling (boiling) curve is sufficiently compared with the previous results.

  • PDF

개구부 삽입부의 길이가 헬륨 및 공기의 치환류에 미치는 영향 (Effect of Opening Partition Length on Helium-Air Exchange Flow)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.192-200
    • /
    • 1999
  • This paper describes experimental investigations of helium-air exchange flow through parti-tioned opening. Such exchange flow may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with a opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Flow measurements are made with partitioned opening for parti-tion rations $H_p/H_1$ in the range 0 to 1 where $H_p$ and $H_1$ are partition length and height of the open-ing respecticely. In the case of $H_p/H_1$ of 0 flow passages of upward flow of the helium and down-ward flow of the air within the opening are unseparated (bidirectional) and the two flows interact exchange flow rate is minimum through range of the partition ratios, Two flow zones i.e. separat-ed(unidirectional)flow zone and unseparated(bidirectional) flow zone exist with increasing the partition. length, The exchange flow rate increases with increasing the separated flow zone. It is found that a maximum exchange flow rate exists at $H_p/H_1$ of 1. As a result fo comparison of the exchange flow rates by changing the partition ration the fluids interaction in the unseparated zone is found to be an important factor on the helium-air exchange flow rate.

  • PDF