• 제목/요약/키워드: marginal

검색결과 2,880건 처리시간 0.03초

국산 하이폴 복합레진의 변록누출에 관한 실험적 연구 (MARGINAL LEAKAGE TEST ON HI-POL COMPOSITE RESIN)

  • 임성삼
    • 대한치과의사협회지
    • /
    • 제15권11호
    • /
    • pp.757-761
    • /
    • 1977
  • The purpose of this study was to evaluate the marginal sealing ability of Hipol composite resin. Using freshly extracted human teeth and 2% acquous methylene blue, the marginal leakage of dye in restorative materials such as Hi-pol, Adaptic, Nuvasystem, Epolite and Amalgam was investigated at 37℃ and under temperature cycling between 4℃ and 60℃. The results were as follows; 1. All the filling materials revealed the penetration of dye between cavity walls and restorations. 2. Hi-pol and Adaptic showed more marginal leakage than other materials and the degree of dye penetration in Hi-pol was similar to that of Adaptic. 3. Nuva system showed the least marginal leakage at 37℃ and under temperature cycling between 4℃ and 60℃. 4. Under temperature cycling, all materials showed a slight increase in marginal leakage except Epolite, which showed the greastest change in leakage.

  • PDF

읍·면지역 한계고령화의 인과순환적 구조분석과 인구소멸 임계점에 대한 시뮬레이션 (Causal Loop-Based Structural Analyses of Marginal Ageing and Critical Mass Simulations for Demographic Extinction Scenarios in Eup and Myeon Regions)

  • 최남희
    • 한국시스템다이내믹스연구
    • /
    • 제17권1호
    • /
    • pp.107-134
    • /
    • 2016
  • Accelerated ageing with low fertility is one of the most critical problems in Korea. Because of ageing via low fertility, Korea will face a serious demographic cliff. This research primarily focus on the analyzing the dynamics of the marginal ageing state and decreasing population especially in Eup and Myeon region. This study based on the system dynamics approaches for finding causal loop structure of marginal ageing and critical mass of population disappearing. The results of this study are summarized as follows. First, demographic marginalization trends have already begun in the Eups and Myons of Gun. Second, marginal aging speed in Eup/Myeon areas is causing an population disappearing in the near future. Third, critical mass of population disappearing will begin when the rate of marginal aging is exceed 82% after 2023.

MATRIX에 따른 임시치관의 변연적합도에 관한 연구 (THE MARGINAL ACCURACY OF TEMPORARY CROWN WITH DIFFERENT MATRIX)

  • 주태훈;조혜원;동진근
    • 대한치과보철학회지
    • /
    • 제29권2호
    • /
    • pp.59-66
    • /
    • 1991
  • This study was designed to investigate the marginal accuracy of resin temporary crown with different matrix in indirect technique. Matrices were made from irreversible hydrocolloid impression material, putty type of vinyl polysiloxane silicone rubber and vacuum formed plastic sheet. The marginal discrepancies of the temporary crowns were measured using a measuring microscope. The obtained results were as follows 1. The marginal accuracy temporary crown using vinyl polysiloxane silicone rubber or vacuum formed plastic form was better than that of the temporary crown using irreversible hydrocolloid impression material. 2. The marginal accuracies of the temporary crown using the irreversible hydrocolloid impression material and putty type of the vinyl polysiloxane silicone rubber obtained the best results at the distal measuring point. 3. The vacuum formed plastic form was recorded a more acceptable marginal accuracy at the distal and mesial measuring points.

  • PDF

도재용 금속 코핑의 처리 방법에 따른 변연 적합도에 관한 연구 (A STUDY ON MARGINAL FIDELITY OF CERAMIC METAL COPINGS TREATED BY VARIOUS METHODS)

  • 구범모;임주환;조인호
    • 대한치과보철학회지
    • /
    • 제35권2호
    • /
    • pp.265-276
    • /
    • 1997
  • The effect of thermocycling and surface finishing on the marginal fidelity of copings for a metal ceramic crown was examined. Methods for minimizing the loss of marginal fidelity were evaluated. The results were as follows ; 1. Thermocycling of ceramic metal copings resulted in increased marginal gap. 2. The greatest marginal gap occurred during the first thermocycling of the copings. 3. No additional distortion of marginal fidelity occurred when surface finishing and second thermocycling were completed after initial thermocycling. 4. The gap increases according to various treatment methods showed group 1 to be the highest values. 5. There was no significant difference between group 2 and group 3(p>0.05) 6. There was significant difference between group 1 and group 2, 3(p<0.05). 7. There was no significant difference among the measurement sites.

  • PDF

치과용 3D 프린팅 시스템에 의해 출력된 보철물의 품질 평가 (An evaluation of quality of dental prostheses printed by dental 3-dimensional printing system)

  • 한만소
    • 대한치과기공학회지
    • /
    • 제38권3호
    • /
    • pp.185-191
    • /
    • 2016
  • Purpose: The purpose of this study were to evaluate the quality of dental prostheses printed by 3-dimensional printing system. Methods: Mater model was prepared and ten study models were fabricated. Ten single crowns were printed by 3D-printing system(Resin group) and another ten single crowns using casting method were manufactured(Metal group). The marginal adaptation of single crowns were measured using by silicone replica technique. Silicone replicas were sectioned four times. The marginal adaptations were evaluated using by digital microscope. Statistical analyses were performed with Mann-Whitney test(${\alpha}=0.05$). Results: $Mean{\pm}standard$ deviations of all marginal adaptations were $92.1(20.0){\mu}m$ for Metal group and $69.7(12.3){\mu}m$ for Resin group. Two groups were no statistically significant differences(p>0.05). Conclusion: Marginal adaptation of single crowns printed by 3D-printing system were ranged within the clinical recommendation.

Glass Ionomer Cement의 변록누출(邊綠漏出)에 관(關)한 실험적(實驗的) 연구(硏究) (AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF GLASS IONOMER CEMENT)

  • 주광섭;유근원
    • Restorative Dentistry and Endodontics
    • /
    • 제7권1호
    • /
    • pp.101-106
    • /
    • 1981
  • The purpose of this study was to estimate the ability of the marginal fit of Glass ionomer cement. Using the human extracted teeth and 2% acqueous solution of methylene blue, the author investigated the marginal penetration of dye in restorative materials such as Amalgam, Hi-Pol, Glass ionomer cement, Estic microfill and Restodent. The results were as follows. 1. All filling materials showed some degree of marginal penetration. 2. Glass ionomer cement revealed nearly the same microleakage as Estic microfill and Hi-Pol, but showed inferior effect of the marginal seal as compared with Restodent. 3. It is appeared that Amalgam has more effective ability of the marginal fit than the others within a week.

  • PDF

한계농지개발사업의 개발전망과 활성화 방안 (An Activation Proposal for the Marginal Farmland Redevelopment Project in Korea)

  • 한경수;김영주;최수명
    • 농촌계획
    • /
    • 제12권4호
    • /
    • pp.33-42
    • /
    • 2006
  • Recently, Korean government has been initiating various schemes for reactivation of the marginal farmland use. However, although about ten years have passed from the introduction of the marginal farmland redevelopment projects in 1995, there have been very few research works on their systematic and objective appraisal. Therefore, this study checked the statutory concept and development schemes of the marginal farmland, firstly. Ant through case studies on 5 completed project sites and questionnaire/interview surveys on local government officers/private developers, problems and suggestions on project implementation were analysed. Finally, in consideration with analysed results and suggestions together, tentative project directions and reaction schemes on marginal farmland development were proposed.

A vertically split fracture of the marginal tubercle of the zygoma in a 3-year-old boy: a case report

  • Chan Yeong, Lee;Chul Han, Kim
    • 대한두개안면성형외과학회지
    • /
    • 제23권6호
    • /
    • pp.274-277
    • /
    • 2022
  • Fractures of the zygoma are rarely encountered in pediatric patients. This report presents a case of a 3-year-old child who presented with a vertically split fracture of the marginal tubercle of the zygoma. The marginal tubercle, a bony portion present on the posterior border of the frontal process, assists in attaching the temporalis fascia. This patient was treated surgically with bony fixation using tissue glue. To the best of our knowledge, no cases of fracture of the marginal tubercle of the zygoma have been reported in the literature. Fractures of the marginal tubercle of the zygoma in pediatric patients may be overlooked because of their anatomic location and the musculoskeletal characteristics of these patients. Here, we discuss the clinical features of marginal tubercle fractures of the zygoma.

MARGINAL FITNESS OF PORCELAIN-FUSED-TO-METAL CROWN ACCORDING TO MATERIAL AND TECHNIQUE

  • Jeon, Young-Chan
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.120-132
    • /
    • 1998
  • This stusy was to investigate the marginal fitness of porcelain-fused-to- metal crown after succesive firing cycle. Main variables were the degree of marginal curvature of labiocervical margin and the type of alloy. The exaggerated marginal curvature(EMC) was created by additional reduction at the faciocervical wall of the normallized marginal curvature (NMC)-typed ivorine tooth by using milling machine. The difference in the shape was the mid facial margin was placed 2mm apical to cemento- enamel junction in labial surface. Three types of alloy were high noble, noble, and base metal alloy. Test specimens were divided into 8 groups and each group had 8 specimens. Sixty four ceramometal crowns were made totally. Measurement stages were following degassing, opaquing. body porcelain firing, and glazing, and measuring sites were 4. (midmesial, midfacial, middistal, and midlingual). Digital, travelling measuring microscope (0.5 um precision, Olympus. Japan) was used under ${\times}250$ magnification. Within the limitation of this investigation, it was concluded as belows: 1. The pattern of marginal distortion was varied. Degassing stage was not a specific, causative stage that induce most of total marginal distortion during whole procedure fabricating a ceramometal crown. Body firing stage induced discrepancy relatively more than other firing stages. 2. The specimens that were Ni-based alloy and had EMC were distorted persistently following successive fabricating procedures. But marginal openings were decreased after glazing. 3. The release of metal grinding-induced stress was presumed as a cause that induce marginal distortion. 4. The amount of discrepancies of the labial and lingual margins were greater than that of the mesial and distal margin in the specimen that had EMC. 5. Silver-plated die was not enough to resist abrasion during repeated seating of metal copings on the die-holding device.

  • PDF

IPS Empress $2^(R)$를 이용한 전부도재관의 변연적합성과 파절강도에 관한 연구 (A STUDY ON THE MARGINAL FIDELITIES AND FRACTURE STRENGTH OF IPS EMPRESS $2^(R)$ CERAMIC CROWNS)

  • 유지형;김용철;강동완
    • 대한치과보철학회지
    • /
    • 제38권5호
    • /
    • pp.606-617
    • /
    • 2000
  • The purpose of this study was to measure the marginal fidelities and the fracture strength of IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$ ceramic crowns. After constructed of 12 experimental dies for each group, ceramic crowns were fabricated on the metal master dies prepared on the maxillary right premolar Marginal gaps were measured on the specimen between the margin of each crown and finish-ing line of the metal master die by using stereo-microscope($SZ-ST^{(R)}$ Olympus, Japan) and all specimens were cemented on the metal master die with Bistite $II^{(R)}$ (Tokuyama soda Co, LTD., Japan) resin cement. Finally marginal gaps were measured again. To measure of the fracture strength, buccal incline on the functional cusp of specimens were loaded until the catastrophic failure occurred by using the AGS-1000 $D^{(R)}$(Shimadzu, Japan). The result of marginal fidelities and fracture strength were statistically analyzed with the SPSS version 8.0 programs. The results of this study were as follows : 1. No significant difference was found in the mean marginal fidelities and fracture strength between the IPS Empress $2^{(R)}\;and\;In-Ceram^{(R)}$. 2. In comparison of marginal fidelities between before and after cementation, there was significant difference(P<0.05). The IPS Empress 2 system was shown in this study that had good marginal fidelities and fracture strength compared to In-Ceram ceramics. Although this system was acceptable to clinical applications, the system still has to be considered long-term researches about marginal fidelities and fracture strength due to the lack of data about the clinical researches.

  • PDF