• Title/Summary/Keyword: manual-based test

Search Result 296, Processing Time 0.026 seconds

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

Quality Control of Radiation Dosimetry Service (개인피폭선량 측정기관의 품질관리기준 개발)

  • Lee, Jun-Haeng;Lee, Sang-Bock;Chang, Kun-Jo;Lee, Kwang-Yong;Lee, Hyun-Koo;Kim, Hyeog-Ju;Jin, Gye-Hwan
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.253-259
    • /
    • 2009
  • We have developed standards based on international criterions for the quality control of dose tested by the measurement institutions of individual exposure doses through improving the reliability of data on the exposure dose of individuals working in radioactive environment and securing the accuracy and reliability of individual dose measurements. Laws related to radiation dose applied to domestic institutions refer to ANSI N13.11.1993, but currently, in U.S. and some other countries the measurement of radiation doses is based on ANSI N13.11.2001 that reduced test categories and tightened the standards. We made efforts to simplify the standards and to reduce the number of dosimeters required in experiment, and avoided preventing or hindering the use of future technologies not approved under the current law such as glass dosimeter and optical stimulation dosimeter. The Quality Management Manual of Radiation Dosimetry Service, Assessment Manual of Radiation Dosimetry Service Accreditation Program, and the Personnel Dosimetry Performance. Criteria for Testing are documents applicable in supervising laboratories.

  • PDF

A Study on the Installation of SCR System for Generator Diesel Engine of Existing Ship (기존 선박의 디젤발전기용 SCR 시스템 설치에 관한 연구)

  • Ryu, Younghyun;Kim, Hongryeol;Cho, Gyubaek;Kim, Hongsuk;Nam, Jeonggil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.4
    • /
    • pp.412-417
    • /
    • 2015
  • The IMO MEPC has been increasingly strengthening the emission standard for marine environment protection. In particular, nitrogen oxide (NOx) emissions of all ocean-going ships built from 2016 will be required to comply with the Tier-III regulation. In this study, a vanadia based SCR (Selective Catalytic Reduction) system developed for ship application was installed on a diesel engine for power generation of the training ship T/S SAENURI in Mokpo National Maritime University. For the present study, the exhaust pipeline of the generator diesel engine was modified to fit the urea SCR system. This study investigated the NOx reduction performance according to the two kind of injection method of urea solution (40%): Auto mode through the PLC (Programable Logic Control) and Manual mode. We were able to find the ammonia slip conditions when in manual mode method. So, the optimal urea injection quantity can be controlled at each engine load (25, 35, 50%) condition. It was achieved 80% reduction on nitrogen oxide. Furthermore, we found that the NOx reduction performance was better with the load up-down (while down to 25% from 50%) than the load down-up (while up to 50% from 25%) test.

Aquatic Toxicity Assessment of Phosphate Compounds

  • Kim, Eunju;Yoo, Sunkyoung;Ro, Hee-Young;Han, Hye-Jin;Baek, Yong-Wook;Eom, Ig-Chun;Kim, Hyun-Mi;Kim, Pilje;Choi, Kyunghee
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.2.1-2.7
    • /
    • 2013
  • Objectives Tricalcium phosphate and calcium hydrogenorthophosphate are high production volume chemicals, mainly used as foodstuff additives, pharmaceuticals, lubricants, synthetic resin, and disinfectants. Phosphate has the potential to cause increased algal growth leading to eutrophication in the aquatic environment. However, there is no adequate information available on risk assessment or acute and chronic toxicity. The aim of this research is to evaluate the toxic potential of phosphate compounds in the aquatic environment. Methods An aquatic toxicity test of phosphate was conducted, and its physico-chemical properties were obtained from a database recommended in the Organization for Economic Cooperation and Development (OECD) guidance manual. An ecotoxicity test using fish, Daphnia, and algae was conducted by the good laboratory practice facility according to the OECD TG guidelines for testing of chemicals, to secure reliable data. Results The results of the ecotoxicity tests of tricalcium phosphate and calcium hydrogenorthophosphate are as follows: In an acute toxicity test with Oryzias latipes, 96 hr 50% lethal concentration ($LC_{50}$) was >100 (measured:>2.14) mg/L and >100 (measured: >13.5) mg/L, respectively. In the Daphnia test, 48 hr 50% effective concentration ($EC_{50}$) was >100 (measured: >5.35) mg/L and >100 (measured: >2.9) mg/L, respectively. In a growth inhibition test with Pseudokirchneriella subcapitata, 72 hr $EC_{50}$ was >100 (measured: >1.56) mg/L and >100 (measured: >4.4) mg/L, respectively. Conclusions Based on the results of the ecotoxicity test of phosphate using fish, Daphnia, and algae, $L(E)C_{50}$ was above 100 mg/L (nominal), indicating no toxicity. In general, the total phosphorus concentration including phosphate in rivers and lakes reaches levels of several ppm, suggesting that phosphate has no toxic effects. However, excessive inflow of phosphate into aquatic ecosystems has the potential to cause eutrophication due to algal growth.

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

Study on Friction Characteristic of Sintered Friction Component for Synchronizer-Ring of Diesel Vehicle (디젤차량 싱크로나이저링을 위한 소결마찰재 개발 및 접합특성 평가)

  • Song, Joon Hyuk;Kim, Eun Sung;Kim, Kyung-Jae;Oh, Je-Ha;Yang, Sung Mo;Kang, Shin Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.3
    • /
    • pp.373-378
    • /
    • 2013
  • The speed change performance of transmissions has become a serious issue because of the increase in the inertia moment that has accompanied increases in engine output and transmission size. Therefore, it is necessary to develop better wear resistant friction materials. In this study, an appropriate sintered friction component for the synchronizer ring of a diesel manual transmission was developed, and its bonding characteristics were analyzed. That is, a process for bonding an Fe-based base material and Cu-based sintered friction material was developed. BSE and EDX analyses of this bonding layer were conducted, along with a shear strength test, to determine the bonding characteristics.

Rotator cuff repair with or without proximal end detachment for long head of the biceps tendon tenodesis

  • Mardani-Kivi, Mohsen;Asadi, Kamran;Izadi, Amin;Leili, Ehsan Kazemnejad
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.2
    • /
    • pp.101-105
    • /
    • 2022
  • Background: Rotator cuff tears cause pathologies of the long head of the biceps tendon (LHBT). One of the surgical treatments for such a tear is LHBT tenodesis to the humerus. This study aims to compare simultaneous rotator cuff repair and LHBT tenodesis with or without detachment of the proximal end of the LHBT (PELHBT) from its site of adhesion to the glenoid. Methods: This retrospective study involved patients affected by LHBT pathology with rotator cuff tear. The patients were divided into two groups, with or without PELHBT detachment from the glenoid. Therapeutic outcomes were investigated by evaluation of patient satisfaction, pain based on visual analog scale, shoulder function based on Constant score and simple shoulder test, and biceps muscle strength based on the manual muscle testing grading system before surgery, at 6 months, and at the final visit after surgery. Results: Groups 1 and 2 comprised 23 and 26 patients, respectively, who showed no significant differences in demographic characteristics (p>0.05). Shoulder function, biceps muscle strength, pain, and satisfaction rate improved over time (p<0.05) but were not significantly different between the two groups (p>0.05). No post-surgical complication was found in either group. Conclusions: There was no difference in final outcomes of tenodesis with or without detachment of the PELHBT from the supraglenoid tubercle. Such tendon detachment is not necessary.

Application of Grouting of the Sea-Crossing Bridge Foundation in Busan-Geoje Fixed Link (부산~거제간 연결도로 해상교량기초 그라우팅 시공사례 연구)

  • Park, Chung-Whan;Jeong, Sang-Kyoon;Jeong, Gyeong-Hwan;Shin, Min-Sik;Park, Chan-Woo;Kwon, Jin-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.665-678
    • /
    • 2007
  • It was applied the grouting method to fill densely the space between the bottom of the caisson and the ground with the grout mixture mixed with anti-washout admixture after locating accurately the precast caisson on three concrete landing pads but it is far different from a costly conventional method, which place concrete to build the foundation of reinforcement concrete on the spot after excavating inside of the temporary coffering wall for the bridge foundation in the sea. To verify the grouting method in advance, the full-scale trial test was performed twice on the land. After confirming the fluidity of material for the injection and some possible problems during construction and then enhancing the original design, the main process is ongoing and it has been finished 12 spots until now. The purpose of this study is to introduces for the first time in Korea the grouting method including the automatic and the manual monitoring process applied to, based on the main process of the caisson foundation finished already in the site. In a similar construction it is sincerely expected to be referred to in the future.

  • PDF

Research for Health Examinations for Infants and Children by Korean Medicine (한방 영유아 건강검진 도입 필요성 연구)

  • Yu, Seung Ju;Cheon, Jin Hong;Kim, Ki Bong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.30 no.2
    • /
    • pp.10-22
    • /
    • 2016
  • Objectives This study is to analyze current guidelines for health check-ups in infants and children, and to develop better guidelines based on oriental medicine. Methods We analyzed The Manual of 2015's Health Examination for Infants and Children which is a Korean Developmental Screening Test for Infants and Children (K-DST). The statistics from the test was collected from 2010 to 2014 to figure out the problems of Health Examinations for Infants and Children. 20 articles from 2000 to 2014 from RISS, NDSL were also analyzed. Results The current guidelines for health examinations in infants and children didn't include major pediatric diseases such as allergy and asthma. Also, the pediatrics health education materials were mainly focused on hypernutrition but not so much on nutrition deficiency. The number of the centers for Health Examinations for Infants and Children was 52.2% of the number of NIP-Participating medical institutions for infants and children. Conclusions Oriental medicine can be useful to prevent major pediatric diseases and to promote general health in pediatrics. By legislating 'Geon-a-beop', which is a law for infants and children, we can increase the number of medical centers for infants and children to get health check-ups. Currently, there are 9,769 Korean medical institutions, and the rate of traditional medical doctors of public health doctors was 25.5%. Weak Children Questionnaire is developed, considered to be more useful when it is developed with 5-point scale rather than 2.

Isolation and Characterization of Lactic Acid Bacteria Producing Antimutagenic Substance from Korean Dongchimi (동치미로부터 항돌연변이 물질을 생산하는 유산균의 분리 및 특성)

  • 주길재;이창호;우철주
    • Journal of Life Science
    • /
    • v.11 no.5
    • /
    • pp.432-438
    • /
    • 2001
  • Various lactic acid bacteria were isolated from Korean Dongchimi (whole radish Kimichi with added water) in order to study their antimutagenic activity. Ames test using Salmonella enterica serovar typhimurium TA98 and TA100 showed the strain DLAB19 to have the highest antimutagenic activity among the 300 isolated strains against MNNG(N-methyl-N-nitro-N-nitrosoguanidine), NPD (4-nitro-O-phenylenediamine), 4-NQO(4-nitroquinoline-1-oxide) and AFB$_{1}$(aflatoxin B$_{1}$). The strain was identified as Leuconostoc mesenteroides subsp. cremoris according to the Bergeys Mannual Systematic Bscteriology based on its morphological, cultural, physiological characteristics and biological system Antimutagenic activity of Leu. mesenteroides subsp. cremoris DLAB19 was found in the culture supernatant suggesting the bacterium secretes, the antimutagenic substance in the media. The antimutagenic activity of Leu. mesenteroides subsp. cremoris DLAB19 was reconfirmed by the spore-rec assay using spores of Bacillus subtilis H17 (Rec$^{+}$) and M45 (Rec$^{[-10]}$ ).).

  • PDF