• Title/Summary/Keyword: maneuver

Search Result 844, Processing Time 0.018 seconds

Evaluation of Autonomic Neuropathy in Patients with Sleep Apnea Syndrome (수면 무호흡 증후군 환자에서 자율 신경 장애의 평가)

  • Lee, Hak-Jun;Park, Hye-Jung;Shin, Chang-Jin;Kim, Ki-Beom;Chung, Jin-Hong;Lee, Kwan-Ho;Lee, Hyun-Woo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.404-415
    • /
    • 1998
  • Background: Sleep apnea syndrome, which occurs in 1~4 % of the adult population, frequently has different cardiovascular complications such as hypertension, ischemic heart disease, cardiac arrythmia as well as sleep-wake disorder such as excessive daytime hypersomnolence or insomnia. Mortality and vascular morbidity are reported to be significantly higher in sleep apnea syndrome patients than in normal population. According to the recent studies, autonomic dysfunction as well as hypoxemia, hypercapneic acidosis, and increased respiratory effort, may playa role in the high prevalence of cardiovascular complications in patients with sleep apnea syndrome. However the cause and mechanism of autonomic neuropathy in patients with sleep apnea syndrome are not well understood. We studied the existence of autonomic neuropathy in patients with sleep apnea syndrome and factors which influence the pathogenesis of autonomic neuropathy. Method: We used the cardiovascular autonomic neuropathy(CAN) test as a method for evaluation of autonomic neuropathy. The subjects of this study were 20 patients who diagnosed sleep apnea syndrome by polysomnography and 15 persons who were normal by polysomnography. Results: Body mass index and resting systolic blood pressure were higher in sleep apnea group than control group. Apnea index(Al), respiratory disturbance index(RDI) and snoring time percentage were significantly higher in sleep apnea group compared with control group. But there were no significant differences in saturation of oxygen and sleep efficiency in two groups. In the cardiac autonomic neuropathy test, the valsalva ratio was significantly low in sleep apnea group compared with control group but other tests had no differences between two groups. The CAN scores and corrected QT(QTc) interval were calculated significantly higher in sleep apnea group, but there were no significant correlations between CAN scores and QTc interval. There were no significant data of polysomnography to correlate to the CAN score. It meant that the autonomic neuropathy in patients with sleep apnea was affected by other multiple factors. Conclusion: The cardiovascular autonomic neuropathy test was a useful method for the evaluation of autonomic neuropathy in patients with sleep apnea syndrome and abnormalities of cardiovascular autonomic neuropathy were observed in patients with sleep apnea syndrome. However, we failed to define the factors that influence the pathogenesis of autonomic neuropathy of sleep apnea syndrome. This study warrants futher investigations in order to define the pathogenesis of autonomic neuropathy in patients with sleep apnea syndrome.

  • PDF

The Changes of Cuff Pressure from Endotracheal Intubation for Long-term Mechanical Ventilation (장기간 기계호흡 환자에서 기관내 관의 기낭압의 변화)

  • Jung, Bock-Hyun;Park, Whan;Koh, Youn-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.52 no.2
    • /
    • pp.156-165
    • /
    • 2002
  • Background: A tracheal stenosis is caused by mucosal ischemic injury related to a high cuff pressure ($P_{cuff}$) of the endotracheal tube. In contrast, aspiration of the upper airway secretion and impaired gas exchange due to cuff leakage is related to a low $P_{cuff}$. To prevent these complications, the $P_{cuff}$ should be kept appropriately because the appropriate $P_{cuff}$ appears to change according to the patient's daily respiratory mechanics. However, the constant cuff volume($V_{cuff}$) has frequently been instilled to the cuff balloon on a daily basis to maintain the optimal $P_{cuff}$ instead of monitoring the $P_{cuff}$ directly at the patients' bedside. To address the necessity of continuous $P_{cuff}$ monitoring, the change in the $P_{cuff}$ was evaluated at various $V_{cuff}$ levels on a daily basis in patients with long-term mechanical ventilation. The utility of mercury column sphygmomanometer for the continuous monitoring $P_{cuff}$ was also investigated. Method: The change in $P_{cuff}$ according to the increase in $V_{cuff}$ was observed in 17 patients with prolonged endotracheal intubation for mechanical ventilation for 2 week or more. This maneuver measured the change in $P_{cuff}$ daily during the mechanical ventilation days. In addition, the $P_{cuff}$ measured by mercury column sphygmomanometer was compared with the $P_{cuff}$ measured by an automatic cuff pressure manager. Results : There were no statistically significant changes of $P_{cuff}$ during more than 14 days of intubation for mechanical ventilation. However the $V_{cuff}$ required to maintain the appropriate $P_{cuff}$ varied from 1.9 cc to 9.6 cc. In addition, the intra-individual variation of the $P_{cuff}$ was observed from 10 $cmH_2O$ to 46 $cmH_2O$ at constant 3 cc $V_{cuff}$. The $P_{cuff}$ measured by the bedside mercury column sphygmomanometer is well coincident with that measured by the automatic cuff pressure manager. Conclusion: Continuous monitoring and management of the $P_{cuff}$ to maintain the appropriate $P_{cuff}$ level in order to prevent cuff related problems during long-term mechanical ventilation is recommended. For this purpose, mercury column sphygmomanometer may replace the specific cuff pressure monitoring equipment.

Conjunction Assessments of the Satellites Transported by KSLV-II and Preparation of the Countermeasure for Possible Events in Timeline (누리호 탑재 위성들의 충돌위험의 예측 및 향후 상황의 대응을 위한 분석)

  • Shawn Seunghwan Choi;Peter Joonghyung Ryu;John Kim;Lowell Kim;Chris Sheen;Yongil Kim;Jaejin Lee;Sunghwan Choi;Jae Wook Song;Hae-Dong Kim;Misoon Mah;Douglas Deok-Soo Kim
    • Journal of Space Technology and Applications
    • /
    • v.3 no.2
    • /
    • pp.118-143
    • /
    • 2023
  • Space is becoming more commercialized. Despite of its delayed start-up, space activities in Korea are attracting more nation-wide supports from both investors and government. May 25, 2023, KSLV II, also called Nuri, successfully transported, and inserted seven satellites to a sun-synchronous orbit of 550 km altitude. However, Starlink has over 4,000 satellites around this altitude for its commercial activities. Hence, it is necessary for us to constantly monitor the collision risks of these satellites against resident space objects including Starlink. Here we report a quantitative research output regarding the conjunctions, particularly between the Nuri satellites and Starlink. Our calculation shows that, on average, three times everyday, the Nuri satellites encounter Starlink within 1 km distance with the probability of collision higher than 1.0E-5. A comparative study with KOMPSAT-5, also called Arirang-5, shows that its distance of closest approach distribution significantly differs from those of Nuri satellites. We also report a quantitative analysis of collision-avoiding maneuver cost of Starlink satellites and a strategy for Korea, being a delayed starter, to speed up to position itself in the space leading countries. We used the AstroOne program for analyses and compared its output with that of Socrates Plus of Celestrak. The two line element data was used for computation.

Single Center Experience of the Balloon-Stent Technique for the Treatment of Unruptured Distal Internal Carotid Artery Aneurysms: Sharing a Simple and Reliable Tip to Use Scepter-Atlas Combination (원위내경동맥에 위치한 비파열성 동맥류의 치료에 있어 풍선-스텐트 테크닉에 대한 단일기관의 경험: Scepter-Atlas 조합을 사용하기 위한 간단하지만 확실한 방법)

  • Yu-jung Park;Jieun Roh;Seung Kug Baik;Jeong A Yeom;Chul-Hoo Kang;Hee Seok Jeong;Sang Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1258-1273
    • /
    • 2021
  • Purpose The balloon-stent technique (BST) has certain strengths as an assisted technique for the treatment of complex aneurysms. After Atlas release, the BST can be executed without an exchange maneuver of the balloon to the stent-delivery catheter. The purpose of this article is to share our experience with the BST using the Scepter-Atlas combination. Materials and Methods Device inspection led us to a simple method to avoid failure in loading Atlas to the Scepter. From March 2018 to December 2019, 57 unruptured distal internal carotid artery (dICA) aneurysms were treated with coil embolization; among which, 25 aneurysms in 23 patients were treated with BST. Clinical and angiographic data were retrospectively collected and reviewed. Results The technical success rate of the Scepter-Atlas combination increased from 50% to 100% after careful inspection. BST angiographic results were comparable to the stent-assisted coil (SAC) group treated during the immediately post-embolization same period (modified Raymond-Roy classification [MRRC] 1 & 2 84% in BST, 96.3% in SAC) and during short-term follow-up (MRRC 1 & 2 95.8% in BST, 88.4% in SAC). A small number of patients showed periprocedural complications, but none had clinical consequences. Conclusion BST using the Scepter-Atlas combination can provide an effective and safe method for the treatment of dICA aneurysms. Scepters can be used as delivery catheters for Atlas.