• Title/Summary/Keyword: mammography

Search Result 375, Processing Time 0.039 seconds

Variation of Image Quality and Dose by Applying Multi-Leaf Collimator for Digital Mammography (디지털 유방촬영장치에서 다엽 조리개 적용으로 인한 화질과 선량의 변화)

  • Kwon, Soon Mu;Kim, Boo Soon;Park, Hyung Jun;Kang, Yeong Han
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.535-540
    • /
    • 2015
  • Collimator has important functions with control primary X-ray that decrease radiation exposure dose for patients and reduce scatter ray and make better quality of image. But there are no regulations for X-ray mammography device of collimator, so widely used device adopt rectangularly controlled collimator. Though digital X-ray mammography device expand supply recently, rectangularly controlled collimator of film/screen mode still used. After searching for real condition of beam field with digital mammography, we made a multi-leaf collimator which is able to adjust the beam field in accordance with size and shape of breast, and we measuring up the transitions of image quality, average glandular dose(AGD) and, Dose area product(DAP). There are no significant differences between rectangularly controlled collimator and multi-leaf collimator, and DAP value decreased by 50.72%. As conclusion, there needs to expand the use of multi-leaf collimator for optimum adoption of beam field in digital mammography, and also need to develop an automatic regulation of beam field for reduce of exposure dose to patients.

Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리)

  • Eom, Jisoo;Kang, Sooncheol;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.443-451
    • /
    • 2017
  • Mammography is commonly used for screening early breast cancer. However, mammographic images, which depend on the physical properties of breast components, are limited to provide information about whether a lesion is malignant or benign. Although a dual-energy subtraction technique decomposes a certain material from a mixture, it increases radiation dose and degrades the accuracy of material decomposition. In this study, we simulated a breast phantom using attenuation characteristics, and we proposed a technique to enable the accurate material decomposition by applying weighting factors for the dual-energy mammography based on a photon-counting detector using a Monte Carlo simulation tool. We also evaluated the contrast and noise of simulated breast images for validating the proposed technique. As a result, the contrast for a malignant tumor in the dual-energy weighted subtraction technique was 0.98 and 1.06 times similar than those in the general mammography and dual-energy subtraction techniques, respectively. However the contrast between malignant and benign tumors dramatically increased 13.54 times due to the low contrast of a benign tumor. Therefore, the proposed technique can increase the material decomposition accuracy for malignant tumor and improve the diagnostic accuracy of mammography.

A study on Quality Control of Mammography Equipment in the Gwang-Ju (일부지역 유방 촬영 장비의 정도관리 실태조사 연구)

  • Shin, Ji-Yun;Lee, Sang-Bock;Jin, Gye-Hwan;Lee, Sam-Yeol;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.11-25
    • /
    • 2008
  • As breast cancer shows the highest incidence among women's cancers, the use of mammography is also increasing as a screening test. Mammography should produce high-quality images for accurate diagnosis. For this, it is necessary to manage the performance and image quality of mammography. Thus, in order to investigate quality control, the present study conducted a questionnaire survey of 37 hospitals registered as breast cancer medical examination centers in Gwang-Ju, concerning their quality control of mammography. In the results of surveying the characteristics of apparatus use for mammography, many respondents did not know about the equipment that they were using. Of the hospitals, 19 (49%) were using film, 19 (49%) CR, and 1 DR. In the results of asking how to do quality control, only 38% answered that they inspected according to the manual. In addition, all the surveyed hospitals had specialized agencies do quality control for them. As to the reason for using agencies, 65% mentioned limitations in personnel, time, distance, etc, and 44% mentioned the absence of machines and materials. These results suggest that quality control is being performed perfunctorily, as well as passively and indifferently as it relies on specialized agencies. Accordingly, it is necessary to provide regular education for enhancing people's perception of quality control and to perform quality control adequately in the presence of Radiologist.

  • PDF

Evaluation of the Performance Characteristic for Mammography by Using Edge device (유방영상에서 엣지를 이용한 물리적 영상 평가)

  • Kim, Ki-Won;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Lee, Eul-Kyu;Son, Soon-Yong;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.415-420
    • /
    • 2016
  • The purpose of this study was to evaluation of the performance characteristic for mammography by using edge device that mammography equipment improves essential in the correct diagnosis for the maintenance. We measured the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE) using the 61267 RQA-M2 based on commission standard international electro-technical commission (IEC). As a results, spatial resolution of elenia demensions tomo and lorad selenia mammography were maintained at $10mm^{-1}$ and NPS and DQE including the low nyquist frequency indicated to $6.0mm^{-1}$. Therefore, regulary QA of mammography system should be necessary. This study can be contribute to evaluate QA for performance characteristic of mammography of DDR system.

Changes in Spatial Resolution at Position of the Detector in Digital Mammography System (디지털 엑스선유방촬영장치에서 검출기 위치에 따른 공간분해능의 변화)

  • Kim, Hye-Min;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.215-222
    • /
    • 2016
  • X-ray mammography is the most effective method for the diagnosis of calcified lesions of various breast diseases. To reduce patient dose and to obtain optimal image required for diagnosis, the performance of the mammography system should be maintained continuously. Because the target (anode) angle of the X-ray tube is measured from the central X-ray, the effective angle can be slightly different in view of the position on the detector, which can result in degrading spatial resolution of the imaging within the field of view. In this study, we measured the MTF to examine spatial resolution for positions on the detector in the digital mammography system. For a tungsten wire of $50{\mu}m$ diameter, the highest spatial frequency was obtained. It meant that a wire diameter for measuring MTF through LSF should be small compared to the pixel size of the detector used in the mammography system. The spatial resolution showed slightly different performance according to positions on the detector. The center position gave the best spatial resolution and positions away from the center showed the degraded performance although the difference of the spatial resolution was small. The effective focal spot size of the full width at half maximum also showed similar result. It concluded that the slightly increase of the effective focal spot size gave the degradation of the spatial resolution for positions on the detector.

Mammographic Image Contrast Enhancement using Wavelet Transform (Wavelet 변환을 이용한 Mammographic Image 개선에 관한 연구)

  • 윤정현;김선일;노용만
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.521-524
    • /
    • 1999
  • In spite of advances in image resolution and film contrast, check screen/film mammography remains one of diagnostic imaging modality where the image interpretation is very difficult. For the enhancement of film mammography, in this paper, dyadic wavelet transform is introduced. An unsharp masking technique is proposed and performed in wavelet domain. In addition, simple nonlinear enhancement and a denosing stage that preserves edges using wavelet shrinkage are computed into this technique. In this paper. we propose a new method for the gain setting of nonlinear enhancement and show result and comparison.

  • PDF

Electrical Impedance Tomography as a Primary Screening Technique for Breast Cancer Detection

  • Akhtari-Zavare, Mehrnoosh;Latiff, Latiffah A
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.5595-5597
    • /
    • 2015
  • Electrical impedance tomography (EIT) is a new non-invasive, mobile screening method which does not use ionizing radiation to the human breast. It is based on the theory that cancer cells display altered local dielectric properties, thus demonstrating measurably higher conductivity values. This article reviews the utilisation of EIT in breast cancer detection. It could be used as an adjunct to mammography and ultrasonography for breast cancer screening.

Evaluation of the Usefulness of 3D Printed Shielding Materials Using Monte Carlo Simulation during Mammography (유방 X선 검사 시 몬테카를로 시뮬레이션을 이용한 3D 프린팅 차폐재료의 효용성 평가)

  • Cho, Yong In
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.295-301
    • /
    • 2020
  • Radiation exposure exposed during mammography, which is performed for early examination of breast cancer, has also been suggested as a cause of carcinogenesis in the past, and scattered rays generated during examination may cause unnecessary radiation exposure to surrounding organs. In this study, the Monte Carlo simulation was used to evaluate the human organ doses exposed during conventional mammography, and to estimate the dose reduction effect for each organ when using 3D printing materials for radiation protection by scattered rays. As a result of organ dose evaluation, the breast on the opposite side of the examination was about 22.0% of the breast on the test side and about 58.6% on the eye, which was highly influenced by the scattering-ray. When using the 3D printing shield to protect it, the breast on the opposite side of the test showed an effective dose reduction effect at a thickness of 1 mm.

Mammographic Screening of Women Attending a Reference Service Center in Southern Brazil

  • Lopes, Tiara Cristina Romeiro;Gravena, Angela Andreia Franca;de Oliveira Demitto, Marcela;Brischiliari, Sheila Cristina Rocha;Borghesan, Deise Helena Pelloso;Agnolo, Catia Millene Dell;de Barros Carvalho, Maria Dalva;Pelloso, Sandra Marisa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.1385-1391
    • /
    • 2016
  • Background: To investigate the prevalence of and factors associated with performance of annual mammography by women above 40 years of age. Materials and Methods: This cross-sectional retrospective study was conducted at an oncology reference service in Southern Brazil from October 2013 to October 2014 with 525 women aged 40 years or older. Results: The prevalence of annual mammography was 54.1%; annual mammographic screening was performed for women without private medical insurance, who were under hormone replacement therapy and who had used contraception in the past. An association was found between non-performance of breast clinical and self-examination and non-performance of mammographic screening. Conclusions: Use of mammography for breast cancer screening in the public health care setting proved to be accessible; nevertheless, the proportion of screened women was low, and they exhibited poor adherence to the basic measures of care recommended for breast assessment. Thus, control of breast cancer requires implementing actions targeting the population most vulnerable to non-adherence to screening in addition to continuously monitoring and assessing that population to reduce the prevalence of this disease.

Facilitator Psychological Constructs for Mammography Screening among Iranian Women

  • Taymoori, Parvaneh;Moshki, Mahdi;Roshani, Daem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7309-7316
    • /
    • 2014
  • Background: While many researchers often use a theoretical framework for mammogram repeat interventions, it seems they do not apply an identified mediation analysis method. The aim of this study was to determine the mediators of mammogram replication behavior in two tailored interventions for non-adherent Iranian women. Materials and Methods: A sample population of 184 women over 50 years old in Sanandaj, Iran, was selected for an experiment. Participants were randomly allocated into one of the three conditions: 1) an intervention based on the Health Belief Model (HBM) 2) an intervention based on an integration of the HBM and selected constructs from the Theory of Planned Behavior (TPB), and 3) a control group. Constructs were measured before the intervention, and after a 6-month follow-up. Results: Perceived self-efficacy, behavioral control, and subjective norms were recognized as mediators in the HBM and selected constructs from the TPB intervention. Perceived susceptibility, severity, barriers, self-efficacy and behavioral control met the criteria for mediation in the HBM intervention. Conclusions: This study was successful in establishing mediation in a sample of women. Our findings enrich the literature on mammography repeat, indicating key intervention factors, and relegating redundant ones in the Iranian populations. The use of strategies to increase mammography repeat, such HBM and TPB constructs is suggested to be important for maintaining a screening behavior, once the behavior has been adopted.