• Title/Summary/Keyword: major foramen

Search Result 22, Processing Time 0.015 seconds

In vitro comparison of measurement accuracy In pre-enlarged and enlarged canals with four apex locators (근관 성형 전후의 네 가지 전자근관장측정기의 측정 정확성의 비교)

  • Sung, Sang-Yup;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.5
    • /
    • pp.371-377
    • /
    • 2006
  • The purposes of this study were to assess the accuracy of measurements in pre-enlarged canals with small instruments and to compare the accuracies, in enlarged canal, with small size instruments and instruments that match the actual canal diameter using Root ZX, Bingo1020, SmarPex, and e-Magic Finder. Ten extracted teeth were embedded in an alginate model made for testing apex locators. A size 10 file was placed into the root canal until the tip of the file reached the plane of the major diameter of the foramen under a dental operating microscope at the 25 x magnification. The measurement was done with digital caliper and defined as actual length. Electronic length measurement with a size 10 file in pre-enlarged canal was done by reading the index indicating Apex of each device to gain a definite value After completion of canal enlargement to a size 45 file, each difference between actual length and electric measurement value with a size 10 and 40 files in enlarged canal was recorded as L10 and L40. The one-way ANOVA and Scheffe's multiple range tests were computed for analyze the differences among the four apex locators in the same group. The Student's t-test between L10 and L40 of each locator was done. The accuracies of electronic measurements were significantly different among the 4 devices. The file size made no difference on the accuracy of electronic measurement in enlarged canal with same device. The e-Magic Finder was the most accurate device among the 4 apex locators used in this study.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF