• Title/Summary/Keyword: maintenance energy

Search Result 1,426, Processing Time 0.034 seconds

Optimal Allocation of Shunt Capacitor-Reactor Bank in Distribution System with Dispersed Generators Considering Installation and Maintenance Cost (분산전원을 포함한 배전계통에서 설치비용과 유지보수 비용을 고려한 병렬 캐패시터-리액터 Bank의 최적 설치 위치 선정)

  • Heo, Jae-Haeng;Lyu, Jae-Kun;Lee, Woo-Ri;Park, Jong-Young;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.11
    • /
    • pp.1511-1519
    • /
    • 2013
  • This paper proposes the allocation method for capacitor-reactor banks in a distribution system with dispersed generators to reduce the installation costs, the maintenance costs and minimize the loss of electrical energy. The expected lifetime and maintenance period of devices with moving parts depends on the total number of operations, which affects the replacement and maintenance period for aging equipment under a limited budget. In this paper, the expected device lifetimes and the maintenance period are included in the formulation, and the optimal operation status of the devices is determined using a genetic algorithm. The optimal numbers and locations for capacitor-reactor banks are determined based on the optimal operation status. Simulation results in a 69-bus distribution system with the dispersed generator show that the proposed technique performs better than conventional methods.

Development of Maintenance-Service Model for Small Photovoltaic Equipment (소형 태양광발전설비의 유지관리 서비스 모델 개발)

  • Kang, Seok-Hwa;Park, Byeong-Hun;Choei, Jong-Won;Kim, Jae-Yeob
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.234-235
    • /
    • 2015
  • In South Korea, small photovoltaic equipment is increasingly adopted in more detached houses on the constant basis. With this broader use of small photovoltaic equipment, its systematic maintenance becomes all the more necessary. However, photovoltaic facility maintenance has been concentrated solely on large-scale solar energy generation plants in the country while hardly covering smaller facilities. In this research, the JEM rule and extant maintenance company services were analyzed to develop a proper maintenance model for small photovoltaic equipment. The maintenance service procedures designed herein are as follows: A small photovoltaic equipment user chooses a maintenance company and signs a contract. Once a contract is made, the Korea Energy Management Corporation provides a certain kind of incentive to the company. The company provides maintenance service to the user and receives a service fee. If such a maintenance service model is in place, small photovoltaic equipment efficiency is expected to increase and users could receive systematic maintenance services. Also the new creation of small photovoltaic equipment maintenance service would form a new market to generate more jobs for the society.

  • PDF

Design of a Bridge Transported ServoManipulator System for a Radioactive Environment

  • Park, B.S.;Jin, J.H.;Ahn, S.H.;Song, T.G.;Kim, D.G.;Yoon, J.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2514-2518
    • /
    • 2003
  • The KAERI Spent Fuel Remote Technology Development (SFRTD) Department is developing the remote maintenance and repair equipment, which is used in a hot cell in an intense radiation field, as part of a project to develop the Advanced spent fuel Conditioning Process (ACP). Although several mechanical master-slave manipulators (MSMs) is mounted on the hot cell wall, their reach will be limited and cannot access areas for all the ACP equipment maintenance. A Bridge Transported ServoManipulator (BTSM) has been designed to overcome the limitation of access areas that is a drawback of MSMs for the ACP equipment maintenance. The BTSM system consists of four components: a transporter with telescoping tubeset, a slave manipulator, a master manipulator, and a remote control system. The BTSM system has been designed by Solid Edge that is a 3D computer-aided design (CAD) software, except for the remote control system. The master manipulator and the slave manipulator are kinematically similar in design, except for the handle and the tong, respectively. The manipulators have 6 degrees of freedom (DOF) plus the jaws motion. The transporter has traveling, traverse, and hoisting motion to position the slave manipulator.

  • PDF

Energy Requirements in Early Life Are Similar for Male and Female Goat Kids

  • Bompadre, T.F.V.;Neto, O. Boaventura;Mendonca, A.N.;Souza, S.F.;Oliveira, D.;Fernandes, M.H.M.R.;Harter, C.J.;Almeida, A.K.;Resende, K.T.;Teixeira, I.A.M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.12
    • /
    • pp.1712-1720
    • /
    • 2014
  • Little is known about the gender differences in energetic requirements of goats in early life. In this study, we determined the energy requirements for maintenance and gain in intact male, castrated male and female Saanen goat kids using the comparative slaughter technique and provide new data on their body composition and energy efficiency. To determine the energy requirements for maintenance, we studied 21 intact males, 15 castrated males and 18 females ($5.0{\pm}0.1kg$ initial body weight (BW) and $23{\pm}5d$ of age) using a split-plot design with the following main factors: three genders (intact males, castrated males, and females) and three dry matter intake levels (ad libitum, 75% and 50% of ad libitum intake). A slaughter group included three kids, one for each nutritional plane, of each gender, and all three animals within a group were slaughtered when the ad libitum kid reached 15 kg in BW. Net energy requirements for gain were obtained for 17 intact males, eight castrated males and 15 females ($5.1{\pm}0.4kg$ BW and $23{\pm}13d$ of age). Animals were fed ad libitum and slaughtered when they reached 5, 10, and 15 kg in BW. A digestion trial was performed with nine kids of each gender to determine digestible energy, metabolizable energy and energy metabolizability of the diet. Our results show no effect of gender on the energy requirements for maintenance and gain, and overall net energy for maintenance was $205.6kJ/kg^{0.75}$ empty body weight gain (EBW) ($170.3kJ/kg^{0.75}$ BW) from 5 to 15 kg BW. Metabolizable energy for maintenance was calculated by iteration, assuming heat production equal to metabolizable energy intake at maintenance, and the result was $294.34kJ/kg^{0.75}$ EBW and $k_m$ of 0.70. As BW increased from 5 to 15 kg for all genders, the net energy required for gain increased from 9.5 to 12.0 kJ/g EBW gain (EWG), and assuming $k_g=0.47$, metabolizable energy for gain ranged from 20.2 to 25.5 kJ/g EWG. Our results indicate that it is not necessary to formulate diets with different energetic content for intact male, castrated male and female Saanen goat kids weighing from 5 to 15 kg.

Energy Requirements for Maintenance and Growth of Male Saanen Goat Kids

  • Medeiros, A.N.;Resende, K.T.;Teixeira, I.A.M.A.;Araujo, M.J.;Yanez, E.A.;Ferreira, A.C.D.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.27 no.9
    • /
    • pp.1293-1302
    • /
    • 2014
  • The aim of study was to determine the energy requirements for maintenance and growth of forty-one Saanen, intact male kids with initial body weight (BW) of $5.12{\pm}0.19$ kg. The baseline (BL) group consisted of eight kids averaging $5.46{\pm}0.18$ kg BW. An intermediate group consisted of six kids, fed for ad libitum intake, that were slaughtered when they reached an average BW of $12.9{\pm}0.29$ kg. The remaining kids (n = 27) were randomly allocated into nine slaughter groups (blocks) of three animals distributed among three amounts of dry matter intake (DMI; ad libitum and restricted to 70% or 40% of ad libitum intake). Animals in a group were slaughtered when the ad libitum-treatment kid in the group reached 20 kg BW. In a digestibility trial, 21 kids (same animals of the comparative slaughter) were housed in metabolic cages and used in a completely randomized design to evaluate the energetic value of the diet at different feed intake levels. The net energy for maintenance ($NE_m$) was $417kJ/kg^{0.75}$ of empty BW (EBW)/d, while the metabolizable energy for maintenance ($ME_m$) was $657kJ/kg^{0.75}$ of EBW/d. The efficiency of ME use for NE maintenance ($k_m$) was 0.64. Body fat content varied from 59.91 to 92.02 g/kg of EBW while body energy content varied from 6.37 to 7.76 MJ/kg of EBW, respectively, for 5 and 20 kg of EBW. The net energy for growth ($NE_g$) ranged from 7.4 to 9.0 MJ/kg of empty weight gain by day at 5 and 20 kg BW, respectively. This study indicated that the energy requirements in goats were lower than previously published requirements for growing dairy goats.

Conceptual Design of In-Service Inspection and Maintenance of tiquid Metal Reactor KALIMER (액체금속로 KALIMER의 가동중검사 및 보수 개념설계)

  • Joo, Young-Sang;Kim, Seok-Hoon;Lee, Jae-Han
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 2004
  • The design concepts of in-service inspection and maintenance are very important for the reactor system design of the nuclear power plant. The strategy of in-service inspection and maintenance should be reflected in the mechanical system design for the verification of the operability of liquid metal reactor KALIMER. In this paper the fundamental approaches of the in-service inspection and maintenance of the KALIMER are established to ensure the safety and reliability of the reactor system. The general method and requirement of the in-service inspection and maintenance for the reactor system and components are proposed and described to satisfy the intents of the ASME Section XI Division 3 and the design characteristics of KALIMER.

Visualization and Analysis of Remote Operation involved in Advanced Conditioning Process

  • Yoon, Ji-Sup;Kim, Sung-Hyun;Song, Tai-Gil
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.205-219
    • /
    • 2004
  • The remote operation of the Advanced Spent Fuel Conditioning Process (ACP) is analyzed by using the 3D graphic simulation tools. The ACP equipment operates in intense radiation fields as well as in a high temperature. Thus, the equipment should be designed in consideration of the remote handling and maintenance. As well as suitable remote handling and maintenance technology needs to be developed along with the design of the process concepts. To develop such remote operation technology, we developed the graphic simulator which provides the capability of verifying the remote operability of the ACP without fabrication of the process equipment. In other words, by applying virtual reality to the remote maintenance operation, a remote operation task can be simulated in the graphic simulator, not in the real environment. The graphic simulator will substantially reduce the cost of the development of the remote handling and maintenance procedure as well as the process equipment, while at the same time developing a remote maintenance concept that is more reliable, easier to implement, and easier to understand.

  • PDF

Effects of Acidic Fermentation Products and Culture pH on the Maintenance Energy of Clostridium acetobutylicum (산성 발효 산물과 배양 pH가 Clostridium acetobutylicum의 유지 에너지에 미치는 영향)

  • 신순영;김병홍
    • Korean Journal of Microbiology
    • /
    • v.28 no.3
    • /
    • pp.268-273
    • /
    • 1990
  • In order to elucidate the acid tolerance mechanism of Clostridium acetobutylicum against organic acid, the maintenance energy with added butyrate at different pH was determined. Maintenance coeffecient in acidogenic chemostat was higher at pH 6.5 than at pH 5.5 showing that this organism is an acidophile. The addition of butyrate at pH 5.5 and different dilution rate caused linear decrease of the cell concentration though $Y_{ATP}$ did not decrease with increasing undissociated organic acid. $Y_{ATP}$ decreased by increasing the concentration of undissociated organic acid at pH 5.0 by the addition of butyrate. From these results it is hypothesized that the ATP conaumption for pH stat of acidophile C. acetobutylicum is increased at the circumstance with over 30mM of undissociated organic acid.cid.

  • PDF

Feasibility Analysis for Introducing ESCO Program of LED Luminaire Replacements in Schools

  • Shin, Hyunman;Jang, Woojin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Public institutions should replace their luminaires with LED lighting by 2020 to save energy. Because the LED lighting installation rate in schools has not yet reached the legal goal, the ESCO program feasibility was investigated. The amount of electricity used, electric rates, times of use in classrooms and fluorescent lighting maintenance costs etc., as well as the elements of lighting maintenance were analyzed. In the case of schools, the lamp usage time was so short that the ESCO projects with only energy savings were impossible. In order to execute the ESCO projects, the maintenance cost savings by replacing an existing luminaire should be considered and the introduction of the relatively cheaper tube type LED lamp than the flat type LED luminaire was required.

A Study on the Maintenance Cost Estimation Model of the Apartment Housing (공동주택의 관리비 추정모델 연구)

  • Lee, Kang-Hee;Yang, Jae-Hyuk;Chae, Chang-U
    • Journal of the Korean housing association
    • /
    • v.21 no.2
    • /
    • pp.59-67
    • /
    • 2010
  • The maintenance cost plays a important role to plan the scale of the apartment housing such as a number of household, building area and building type. Therefore, it is required to forecast the cost considering various maintenance characteristics. The maintenance characteristics are floor area, number of household, heating type, site area and etc.. In addition, the maintenance cost are classified into 5 area. These are a personal expense, facility maintenance cost, energy and water cost, insurance and sanitary cost. These five cost area are related with various characteristics and brought up the estimation model using the stepwise multiple regression analysis. The energy and heating cost share over the 50% in the total cost and the personal expense cost shares about 40%. The personal expense cost per area is 5,272 won/$m^2{\cdot}yr$ irregardless of heating type and the district heating type is a higher cost than other type. In facility maintenance cost, the central heating type is 2,015 won/$m^2{\cdot}yr$ and higher than other type. The estimation models have good statistics in each model. Most of the model have a determination coefficient over 0.7 and Durbin Watson value between 1.5 and 2.5.