• Title/Summary/Keyword: main control room

Search Result 211, Processing Time 0.029 seconds

A Study on Design Elements of Main Control Room in Nuclear Power Plants by Analyzing Space Characteristics (원자력발전소 주제어실의 공간특성에 따른 디자인 요소에 관한 연구)

  • Lee, Seung-Hoon;Lee, Tae-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.6
    • /
    • pp.249-256
    • /
    • 2010
  • For guaranteeing for security of nuclear power plant, ergonomic factors have been applied to design of main control room, core area for management and control of nuclear power plant, but design elements for performance of operators have been ignored. As the behaviors of operators are important for security of nuclear power plant, space design which makes them pleasant psychologically and makes them maintain attention on security equipments ceaselessly is required. Therefore, the purpose of this study is to analyze space characteristics of main control rooms according to regulations of nuclear power plant and general guidelines of space design, and to offer basic data for designing of main control room which makes operators pleasant psychologically and physically. At first, theoretical issues related with design of main control room are reviewed and several premises of space are developed by abstracting design elements from common space and regulations of nuclear power plant and, then integrating each design elements interactively. In short, the improvement of system environment based on human-machine interface space has brought about perceptual, cognitive, and spatial changes and has realized next generation of main control rooms. And, differences and similarities between ordinary space and main control room, which ergonomic sizes and regulations are applied and is VDT environment based on LDP, are discussed in relation to 13 design elements and 17 space premise.

A Study on the Application of Friction Pendulum System in Main Control Room of Nuclear Power Plant (마찰진자를 이용한 면진장치의 원전 주 제어실 적용에 관한 연구)

  • Kim, Woo Bum;Lee, Kyung Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.4 s.77
    • /
    • pp.407-417
    • /
    • 2005
  • An experimental and analytical study was performed to apply the friction pendulum system (FPS) to the main control room of a nuclear power plant. A friction pendulum bearing was fabricated, and the dynamic response of the bearing was evaluated. A partial model of a main control room attached to the FPS was tested on the shake table. The model consisted of a cabinet, a $3m\times3m$ access floor, and four friction pendulum bearings. The artificial time history based on the floor response spectrum of the main control room was used as the earthquake input signal in the test. Comparisons between the analytical study and the experimental study were conducted to verify the results and to extend the experimental study to the range of parameters that could not be experimentally studied.

Experimental Study on Floor Isolation of Main Control Room of Nuclear Power Plant using LRB (Lead Rubber Bearing) (납-고무 베어링(LRB) 면진시스템을 적용한 원전주제어실의 진동대 실험)

  • Lee, Kyung-Jin;Ham, Kyung-Won;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.429-436
    • /
    • 2005
  • In this study, we made two types of main control room floor systems (Type I, Type II) and several shaking table tests with and without isolation system were conducted to evaluate floor isolation effectiveness of LRB(Lead Rubber Bearing). Both type showed large difference according to input earthquake signals, but showed little difference according to floor type. It is required to make LRB of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such LRB, it is recommended that consideration should be taken into account when applied to main control room of NPP.

  • PDF

Experimental Study on Vertical Reduction Effectiveness of Main Control Room of NPP using 3-Dimensional Isolation System (원전 주제어실 삼차원 면진시스템 수직방향 저감효과 시험연구)

  • Ham, Kyung-Won;Lee, Kyung-Jin;Suh, Yong-Pyo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.417-423
    • /
    • 2006
  • The seismic characteristics with 3-Dimensional isolation systems have been studied using a shaking table system. In this study, we made nuclear power plant main control room floor systems and several seismic shaking table tests with and without isolation systems were conducted to evaluate floor isolation effectiveness. Isolation systems have showed large reduction effectiveness in acceleration and response spectra with x and z direction respectively, but horizontal isolation is more effective than vertical one It is required to make isolation systems of which design frequency is below 1Hz when applied to main control room of NPP, but considering much difficulties in making such isolation systems, it is recommended that much consideration should be taken into account when applied to main control room of NPP.

  • PDF

A Preliminary Study on the Communication Effect on Team Performance in Main Control Room of SMART

  • Heo, Eun Mee;Byun, Seong Nam
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.97-106
    • /
    • 2013
  • Objective: The aim of this study is to investigate the attributing factors influencing team performance. Background: Technically, it is necessary that operators adapt themselves to computerized and advanced techniques to operate the main control rooms safely in nuclear power plant in Korea. The more main control rooms are digitalized, the more important for operators to have high team performance it is. Method: This paper analyzes team process through literatures review and elicits team performance shaping factor. Especially, the objective of this research is to elicit communication using common team performance shaping factors. Results: This study has found communication through team performance shaping factors in Main Control Room of the SMART. Conclusion: This paper can offer a starting point for team communication, which can use team performance shaping factor framework that are emerging in these new nuclear power plant. Application: As a result, I expect that the evaluation communication for MCR operator's team performance will lead the operating techniques in nuclear power industry internationally.

An Experimental Study on the Sound Insulation Performance of Korean Traditional Houses (전통주택의 차음성능 평가에 관한 실험적 연구)

  • Kim, Sun-Woo;Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.141-148
    • /
    • 2006
  • Korean traditional houses have been evolved and developed in many years, adopting the natural environment to control exterior conditions. These control method are various Passive system of using natural materials, considering micro climate, building lay out, and these system are much natural and ecological to make the comfortable indoor climate than active systems of the present houses. This study aims to analyzed the acoustical characteristics of Korean traditional houses varied with lay out and floor plan to reflect the way of control for environmental condition. The reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen are measured in each houses. As a result, the reverberation time of Korean traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building. These above results show that our traditional house are much more emphasized seeking visual privacy of rooms than aural privacy.

Environment Design for Digitalized Main Control Room in Nuclear Power Plant

  • Cha, Woo Chang
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.7 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • The purpose of the Environment Design (ED) for Main Control Room (MCR) of Nuclear Power Plant (NPP) is to provide and create an optimal working space to be free from physical, physiological and mental stress as well as environmental discomfort, based on the previous environment design experiences and to recommend the best ED including the color, the lighting and the interior design. Environment Design consists of three main areas: Human factor engineering design, Interior design with color design, and Lighting design. These design areas have been interactively cooperated in a way that each design specialist would share the objectives and concepts of the Environment Design for MCR. The specialists for Human Factors Engineering design had a corporative role in such a way to provide the guidelines for MCR design suitability of Interior and Lighting design considering the Human System Interface (HSI) safety concerns. This paper describes fruitful efforts to create the best fit for MCR ED among several design proposals with the design recommendations, impacts, and contributions to NPP environment.

Cable Functional Failure Time Evaluation for a Main Control Room Fire using Fire Dynamic Simulator (FDS 이용한 주제어실 화재시 케이블 기능상실시간 평가)

  • Lim, Heok-Soon;Kim, In-Hwan;Kim, Myung-Su
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.79-85
    • /
    • 2016
  • Serious electrical problems, such as shorts, ground faults, or circuits, often cause fire events in the fire proof zone of nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety-related systems and equipment. The fire event can be treated with the basic design principle that safety systems should maintain their functions with redundancy and independency. In the case of a cable fire in the main control room, operators cannot perform their mission properly and can misjudge the situation because of spurious operation, incorrect indication or instrument. These would deteriorate the plant capabilities of safety shutdown and result in disastrous conditions. Therefore, during a main control room fire, 5 minutes of operator action time is very important to operate the safety shutdown components. This paper describes the cable functional failure temperature criteria and conducted a cable functional failure time evaluation using Fire Dynamic Simulator to obtain the operator action time for a main control room fire.

An Experimental Study on the Acoustic Characteristic of Korean Traditional Houses in Chonnam Province (전남 지방 전통주택의 음향특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Kim, Hyung-Ryul;Kim, Hang;Choi, Eun-Suk;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.686-689
    • /
    • 2005
  • This study aims to analyzed the acoustics characteristics of Korean Traditional Houses in Chonnam Province varied with lay out and floor plane to reflect the way of control for environmental condition. These houses are surveyed the reverberation time and level difference between rooms of the main living room and other main floored room, master room and kitchen. As a result, the reverberation time of traditional rooms are below 0.6 second, and the sound insulation performance of Korean traditional door are mostly very low grade with D-15. The level difference between rooms are low grade not to meet minimum class except between main living room and master room away from main living building.

  • PDF

Nuclear Power Plants' Main Control Room Case analysis for Specialized Space Design (원자력 발전소 주제어실 사례를 통한 특수공간 디자인에 관한 기초적 연구)

  • Lee, Seung-Hoon;Back, Seong-Kyung;Lee, Sang-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.5
    • /
    • pp.81-88
    • /
    • 2007
  • Energy consumption has been increased world widely, and the energy retain is one of the most important economic alternatives. These tendencies expand the nuclear power plants not only quantitatively but also qualitatively. Despite of the increasing construction of nuclear power plants and related facilities, every system in main control room(MCR) has been designed and administered solely based on the safety-first principles because of the specificity of nuclear industry. However, recent main control rooms started with the concept that the operators' performance could be optimized though the organic interrelation between human, machine, and environments. Now, it has been recognised in the scope of Ergonomics and Space Design which acknowledge our living spaces as Man-Environment Interface and this change connotes the MCR spaces should be special spaces rather than ordinary spaces. This research investigated domestic and foreign nuclear power plants' MCRs to suggest basic alternatives which can be applied to future MCR. With the review of characteristics of MCR, an integration of interior design, lighting and Ergonomics was explored and classified as types. Futhermore, the classification of environmental characteristics within the relationships between human, machine, and environments was developed through the case analysis of nuclear power plants. The results of this study will provide a basis of space design for system environments that the high level of safety and function are extremely important.