• 제목/요약/키워드: magnification

검색결과 689건 처리시간 0.027초

Measurement of Ballooning Gap Size of Irradiated Fuels Using Neutron Radiography Transfer Method and HV Image Filter

  • Sim, Cheul-Muu;Kim, TaeJoo;Oh, Hwa Suk;Kim, Joon Cheol
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.212-218
    • /
    • 2013
  • A transfer method of neutron radiography was developed to measure the size of the end plug and a gap of an intact K102L-2, the irradiated fuel of a ballooned K174L-3, a ballooned and ruptured K98L-3. A typical irradiation time of 25 min. was determined to obtain a film density of between 2 and 3 of SR X-ray film with neutrons of $1.5{\times}10^{11}n{\cdot}cm^{-2}$. To validate and calibrate the results, a RISO fuel standard sample, Cd plate and ASTM-BPI/SI were used. An activated latent image formed in the $100{\mu}m$ Dy foil was subsequently transferred in a dark room for more than 8 hours to the SR film which is a maximum of three half-lives. Due to the L/D ratio an unsharpness of $9.82-14{\mu}m$ and a magnification of 1.0003 were given. After digitizing an image of SR film, the ballooning gap of the plug was discernible by an H/V filter of image processing. The gap size of the ballooned element, K174L-3, is equal to or greater than 1.2 mm. The development of a transfer method played a pivotal role in developing high burn-up of Wolsung and PWR nuclear fuel type.

Cryptosporidium suis Infection in Post-Weaned and Adult Pigs in Shaanxi Province, Northwestern China

  • Lin, Qing;Wang, Xing-Ye;Chen, Jian-Wen;Ding, Ling;Zhao, Guang-Hui
    • Parasites, Hosts and Diseases
    • /
    • 제53권1호
    • /
    • pp.113-117
    • /
    • 2015
  • Cryptosporidium spp., ubiquitous enteric parasitic protozoa of vertebrates, recently emerged as an important cause of economic loss and zoonosis. The present study aimed to determine the distribution and species of Cryptosporidium in post-weaned and adult pigs in Shaanxi province, northwestern China. A total of 1,337 fresh fecal samples of post-weaned and adult pigs were collected by sterile disposable gloves from 8 areas of Shaanxi province. The samples were examined by Sheather's sugar flotation technique and microscopy at${\times}400$ magnification for Cryptosporidium infection, and the species in positive samples was further identified by PCR amplification of the small subunit (SSU) rRNA gene. A total of 44 fecal samples were successfully amplified by the nested PCR of the partial SSU rRNA, with overall prevalence of 3.3%. The average prevalence of Cryptosporidium infection in each pig farms ranged from 0 to 14.4%. Species identification by sequencing of SSU rRNA gene revealed that 42 (3.1%) samples were Cryptosporidium suis and 2 (0.15%) were Cryptosporidium scrofarum. C. suis had the highest prevalence (7.5%) in growers and the lowest in breeding pigs (0.97%). C. suis was the predominant species in pre-weaned and adult pigs, while C. scrofarum infected pigs older than 3 months only. A season-related difference of C. suis was observed in this study, with the highest prevalence in autumn (5.5%) and the lowest (1.7%) in winter. The present study provided basic information for control of Cryptosporidium infection in pigs and assessment of zoonotic transmission of pigs in Shaanxi province, China.

촉침식표면거칠기 측정기에 있어서 촉침의 선단곡률반경과 측정압이 측정에 미치는 영향 (The Influence by Stylus Tip Radius and Measuring force on the Stylus Type Surface Roughness Tester)

  • 강명순;한응교;권동호;조남규
    • 한국정밀공학회지
    • /
    • 제3권1호
    • /
    • pp.69-76
    • /
    • 1986
  • The measuring Method by stylus, which measures surface roughness, has been widely used since G. Schmaltz developed the first equipment of that type. Withe the resent development of the measuring method by stylus, surface foughness testing instruments of the very high magnification ratio, hundreds of thousands, are manu- factured. However, as the techniques of the high precision roughness measurement are being required, the response problems due to the tip shapes and the plastic deformations of measured surface of mild material are to be serious factors. In this study, diamond stylus of tip radius $0.5\mu\textrm{m}$, $2\mu\textrm{m}$, $5\mu\textrm{m}$ and $10\mu\textrm{m}$ were used under the measuring force of 0.01gf, 0.02gf, 0.07gf, 0.4gf and 1.6gf, and from the experimental data, maximum measured value devrements between $2\mu\textrm{mR}$ stylus and $5\mu\textrm{mR}$ stylus, $2\mu\textrm{mR}$ stylus and $10\mu\textrm{mR}$ stylus are 22% and 31%, respectively when the measured value of $2\mu\textrm{mR}$ stylus goes to $0.01\mu\textrm{m Ra}$, $\lambda$ c2.5mm. And it is shown that plastic deformations on the plastic deformations on the measured surface are proportional to W/R(W;measured force, R;stylus tip radius).

  • PDF

면내 압축력을 받는 플랫 플레이트 슬래브에 대한 모멘트 증대법 (Moment Magnifier Method for RC Flat Plate Subject to Combined Axial Compressive and Floor Load)

  • 박홍근
    • 콘크리트학회지
    • /
    • 제11권1호
    • /
    • pp.243-254
    • /
    • 1999
  • 면외 바닥하중과 면내 압축력을 받는 플랫플레이트 슬래브에 적용할 수 있는 모멘트증대법을 개발하기 위하여 수치해석연구를 실시하였다. 수치해석연구를 위하여 재료와 기하학적 비선형효과를 고려한 비선형 유한요서 해석프로그램을 개발하였으며, 해석모델로서 국내 철근콘크리트계산규준의 직접설계법에 의하여 설계된 플랫플레이트 슬래브를 사용하였다. 본 연구는 지배하중조건인 수직하중후 1축압축력의 조합하중을 받는 슬래브에 대한 좌굴하중과 모멘트증대계수를 제안하였다. 좌굴하중은 두 개의 요소, 즉 슬래브의 기하학적 형태의 영향을 나타내는 좌굴계수와 압축과 인장 균열에 의한 손상정도를 나타내는 유효휨강성으로 정의된다. 변수연구를 통하여 좌굴계수와 유효휨강성의 변화를 연구하였으며, 이 수치해석결과를 바탕으로 좌굴계수와 유효휨강성의 설계값과, 이를 사용하는 모멘트증대법을 제안하였다.

안면동맥 천공지피판술을 이용한 뺨결손의 재건 (Reconstruction of Cheek Defect with Facial Artery Perforator Flap)

  • 강재경;송정국;정현교;신명수;윤병민
    • 대한두개안면성형외과학회지
    • /
    • 제13권2호
    • /
    • pp.139-142
    • /
    • 2012
  • Purpose: To reconstruct the midface, local flaps such as nasolabial flaps have been frequently used. These local flaps, however, have the shortcomings of requiring a secondary operation or limitations in the movement of the flap. Thus, new methods have been developed. This paper reports a case wherein the basal cell carcinoma on the cheek was resected and the skin and soft tissue defect was successfully treated using a facial artery perforator flap. Methods: A 68-year-old female consulted the authors on the basal cell carcinoma that developed on her cheek. The mass was fully resected and revealed a $2.3{\times}2.3cm$ defective region. Using a Doppler ultrasonography, the facial artery path was traced, and using a loupe magnification, the facial artery perforator flap was elevated and the defective region was covered with the flap. Results: The flap developed early venous congestion, but it disappeared without any treatment. Six months after the surgery, the patient was satisfied with the postoperative result. Conclusion: The facial artery perforator flap has a thin pedicle. It offers a big arc of the rotation that allows free movement and one-stage operation. These strengths make the method useful for the reconstruction of the midface among other procedures.

임상가를 위한 특집 4 - 안면비대칭의 외과적 교정 (Facial asymmetry: Critical element of clinical successful treatment)

  • 홍종락
    • 대한치과의사협회지
    • /
    • 제52권10호
    • /
    • pp.623-632
    • /
    • 2014
  • 안면비대칭의 주원인은 하악골이며, 하악골의 비대칭 성장에 대한 상악골의 보상성장에 따라 교합면 경사 등이 초래된다. 디지털 사진과 삼차원 CT 등 다양한 방법으로 정확한 진단을 하고 수술을 포함한 치료계획을 세운다. 술전 교정 치료는 상악골과 하악골 치열의 치성 보상(dental compensation)을 제거하면서 상악 치열의 중심은 상악골의 정중선에, 하악 치열의 중심은 하악골 정중선에 맞게 이동하여 술후 상하악 치열궁이 일치하면서 동시에 안모 정중선에 일치하게 맞추어야 한다. 악교정 수술은 일반적으로 상하악 동시 수술을 하게 되며 우각부 풍융도 교정과 이부 성형술(genioplasty) 등을 부가적으로 할 수 있으며, 교합면 경사 교정과 수평 회전 등의 이동이 상하악 위치에 서로 영향을 주면서 수술 후 안모 변화에 대한 예측을 어렵게 만들기 때문에, 다양한 분석을 통해 정확한 예측으로 최선의 결과를 얻는 것이 가장 중요하다.

시멘트 공간이 캐드캠 시스템으로 제작한 지르코니아 수복물의 변연과 내부 적합도에 미치는 효과 (Effect of cement space on the marginal and internal fit of zirconia restorations fabricated by CAD/CAM system)

  • 이정환;안재석
    • 대한치과기공학회지
    • /
    • 제39권4호
    • /
    • pp.235-242
    • /
    • 2017
  • Purpose: The aim of this study was to evaluate the marginal and internal gap of zirconia copings fabricated by CAD/CAM system and to research the effect of cement space on the fit of zirconia prosthesis. Methods: Zirconia copings were designed using 3shape software and then milled from presintered zirconia blocks by Kavo dental milling machine. The cement space was set at $0{\mu}m$ around the margins for all groups, and additional cement space appling 1 mm above the finish lines of tooth. The samples were classified into 4 groups according to the cement space setting(Cs-0, Cs-40, Cs-80, Cs-120). Replica technique used to investigate marginal and internal gap. The silicone film thickness was recorded using a optical microscope with image software analysis system at 75${\times}$magnification. The assessment performed on the six points in bucco-lingual and mesio-distal sections(4 groups, 10 copings per group, 12 measuring points per coping). The data were statistically analyzed with one-way ANOVA followed by pair-wise Tukey's post hoc tests(${\alpha}$<0.05). Results: Better marginal and internal fit values were exhibited by $80{\mu}m$ cement space. The results showed that different cement space values had statistically significant effect on the marginal and internal gap of zirconia copings(p<0.001). The gap of margin and axial wall area was smaller than that the gap of occlusal area in all groups(p<0.001). Conclusion : Effect of different cement spaces on the marginal and internal gap of zirconia copings.

이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템 (A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration)

  • 배상우;김민영;고국원;고경철
    • 제어로봇시스템학회논문지
    • /
    • 제19권11호
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

공공의료기관의 공공성과 수익성 상호관계에 대한 연구 - 지방공사의료원의 경영평가를 중심으로- (Profitability and Publicity of the Regional Public Hospitals in Korea - With focus on administration assessment of regional public hospitals -)

  • 이동원;윤방섭;남은우
    • 한국병원경영학회지
    • /
    • 제12권2호
    • /
    • pp.43-68
    • /
    • 2007
  • The administration of a regional public hospitals are expending from profit preference to publicity preference. The weight rate for a profitability and publicity of performance assessment has changed from 84:16 which was resulted by the assessment executed firstly in 1989 to 39:61 as resulted in 2004, the final assessment execution in 2005. Regional public hospitals are exerting and promoting a magnification in public sector to raise up the public-score. With comparison between publicity scores and profitability scores in original scores basis excluding weight rate, the publicity scores ranked higher than profitability scores although the latter was higher by 2002. However, for the administration performance of the regional public hospitals, the deficits increased 11 times from \92.6billion deficits with \460.3billion cost increased by 457% although income as \367.7billion increased by 394% comparing the last 2004 year to the first 1989 year for profit & loss statement of a regional public hospitals. There was analysis for the relation in yearly basis partitioning publicity and profitability for the assessment scores of the to regional public hospitals confirm the accumulated deficits of the hospitals like this attribute to the extension of public sector. The result showed that there was distinct plus relationship from 1999 although a minus relationship in general until 1997 except 1992 and there is a more plus relationship as approaching 2004. That is, it is hard to tell that the accumulated deficits increase of regional government medical center attributed to extension of public sector. On the contrary, the analysis showed the extension of public sector has a mutual relationship with uplift of profitability Meanwhile, it showed that operation cost rate and labor cost are the factors which influence a revenue & expenditure rate among the profitability index according to the results of relation analysis for the representative index of profitability and that of publicity.

  • PDF

Comparison of prosthetic models produced by traditional and additive manufacturing methods

  • Park, Jin-Young;Kim, Hae-Young;Kim, Ji-Hwan;Kim, Jae-Hong;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제7권4호
    • /
    • pp.294-302
    • /
    • 2015
  • PURPOSE. The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). MATERIALS AND METHODS. Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (${\alpha}=.05$). RESULTS. The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. CONCLUSION. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.