• Title/Summary/Keyword: magnification

Search Result 693, Processing Time 0.023 seconds

Trap and movement of Mie particles by using the focussed He-Ne laser beam (집속된 헬륨네온 레이저 광압을 이용한 Mie 입자들의 포획과 이동)

  • Song, Young-Gon;Jo, Jae-Heung;Chang, Soo
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.141-146
    • /
    • 2000
  • Mie particles such as polystylene latex spheres with $3~5{\mu}m$ diameters are easily trapped and freely moved toward an arbitrary position by using the low power He-Ne laser beam focussed by the objective lens with the magnification of 40 X or 100 X. By using this technology, we can successfully arrange Mie particles in the form of the capital letter A. As a result, we can confirm the possibility of the optical tweezer that can readily trap and freely move the Mie particles. icles.

  • PDF

The Evaluation of Mechanical Properties on the Changes of Microstructure for Titanium Alloy (Ti-6Al-4V) (티타늄 합금(Ti-6Al-4V)의 조직변화에 따른 기계적 특성 평가)

  • Gwon, Jae-Do;Bae, Yong-Tak;Choe, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.4
    • /
    • pp.609-616
    • /
    • 2002
  • The characteristics of mechanical behavior are investigated for Ti-6Al-4V alloy. Four kinds of the specimens are prepared under different heat treatments in order to produce different microstructures. In the present investigations, impact, tensile and fatigue crack growth tests are performed for each test specimen. The results obtained through the investigations are compared. Additionally fr actal dimensions of crack pass are obtained using the box counting method. The results are, 1) the microstructures shows as equiaxed, bimodal and Widmanstatten microstructures respectively, 2) the impact energy and elongation are superior fur the bimodal microstructure, and the hardness and tensile strength are superior fur the Widmanstatten microstructure, 3) the fatigue crack growth rate is similar to all microstructures in low ΔK region while that of equiaxed microstructure is the largest, and that of Widmanstatten microstructure is the lowest in high ΔK region respectively, 4) the fractal dimension D of Widmanstatten microstructure shows higher value than that of the equiaxed and bimodal microstructures under 200 magnification view of the SEM micrographs.

Design of spectrally encoded real-time slit confocal microscopy (파장 코딩된 실시간 슬릿 공초점 현미경의 설계)

  • Kim Jeong-Min;Kang Dong-Kyun;Gweon Dae-Gab
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.576-580
    • /
    • 2005
  • New real-time confocal microscopy using spectral encoding technique and slit confocal aperture is proposed and designed. Spectral encoding technique, which encodes one-dimensional spatial information of a specimen in wavelength, and slit aperture make it possible to obtain two-dimensional lateral image of the specimen simultaneously at standard video rates without expensive scanning units such as polygon mirrors and galvano mirrors. The working principle and the configuration of the system are explained. The variation in axial responses for the simplified model of the system with normalized slit width is numerically analyzed based on the wave optics theory. Slit width that directly affects the depth discrimination of the system is determined by a compromise between axial resolution and signal intensity from the simulation result. On the assumption of the lateral sampling resolution of 50 nm, design variables and governing equations of the system are derived. The system is designed to have the mapping error less than the half pixel size, to be diffraction-limited and to have the maximum illumination efficiency. The designed system has the FOV of $12.8um{\times}9.6um$, the theoretical axial FWHM of 1.1 um and the lateral magnification of-367.8.

  • PDF

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.

THE EFFECT OF OBTURATION TECHNIQUES ON THE APICAL MICROLEAKAGE OF ROOT CANALS (근관충전방법에 따른 치근단부 근관의 미세누출에 관한 연구)

  • Yoo, Hyung-Jun;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.213-222
    • /
    • 1998
  • Advisor: Prof. The quality of apical seal obtained with 3 different gutta-percha obturation techniques was compared in 49 recently extracted single rooted teeth. The root canals were instrumented using step-back technique and obturated with laterally condensed gutta-percha, Continuous Wave gutta-percha, and hybrid technique. Teeth were suspended in black India ink for 7 days, cleared, and then examined under a stereomicroscope at ${\times}10$ magnification. The results were as follows; 1. All experimental groups produced favorable apical seal. 2. The mean leakage was $0.23{\pm}0.25mm$ for group 1, $0.17{\pm}0.21mm$ for group 2, and $0.19{\pm}0.23mm$ for froup 3, but there was no statistical difference amoung them. Within the limits of the results of this experiment, the Continuous Wave gutta-percha obturation technique demonstrated relatively favorable apical sealing effect and shorter obturation time. Thus, it is thought that this obturation technique is a acceptable method for clinical use but further studies on this metter should be conducted.

  • PDF

A Study on the Countermeasures to Suppress Harmonics in the Traction Power Supply System (철도 급전시스템에서의 고조파 해석 및 대책 연구)

  • 오광해;이장무;창상훈;한문섭;김길상
    • Proceedings of the KSR Conference
    • /
    • 1999.11a
    • /
    • pp.318-325
    • /
    • 1999
  • Modern AC electric car has PWM(Pulse Width Modulation)-controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit, As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

Quality improvement scheme of magnified image by using gradient information between adjacent pixel values (인접 픽셀 값과의 기울기 정보를 이용한 확대 영상의 화질 개선 기법)

  • Jung, Soo-Mok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.2
    • /
    • pp.59-67
    • /
    • 2012
  • In this paper, an efficient interpolation scheme using gradient information between adjacent pixel values was proposed to estimate the value of interpolated pixel to have the locality which exists in real image and the characteristic of simple convex surface and simple concave surface which exist partially in the real image. PSNR(Peak Signal to Noise Ratio) was used to evaluate the performance of the proposed scheme. The PSNR values of the magnified images using the proposed scheme are greater than those of the magnified images using the previous interpolation schemes.

Measurement of 3-D Deformation by Using Holospeckle Interferometry (홀로스펙클 간섭법을 이용한 3차원 변형측정 연구)

  • 박승옥;권영하;유성규
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.12-15
    • /
    • 1990
  • Holospeckle interferometry, the combined technique of holographic interferometry and speckle photography, was applied to the measurement of 3-D contact deformation created by an indentor. This new tech$.$ nique makes possible to measure both in-plane and out-of-plane displacements from one photographic plate. In this study, the optical system based on image holography was set up. In order to enhance the size and the contrast of the speckle, a proper magnification and a low reference beam ratio was used as compared with the conventional holographic interferometry technique. This system shows the magnified and clear holographic interference fringe as well as Young's fringe patterns.tterns.

  • PDF

Comparison the fit of three-unit metal framework fabricated by wax milling method and digital light projection method (왁스 밀링 방법 및 디지털 광 프로젝션 방법으로 제작된 3본 금속 구조물의 적합도 비교)

  • Lee, Jung-Hwan;Ahn, Jae-Seok
    • Journal of Technologic Dentistry
    • /
    • v.41 no.1
    • /
    • pp.9-19
    • /
    • 2019
  • Purpose: This study was conducted to comparative evaluate the marginal and internal gap of three-unit metal frameworks(Co-Cr) fabricated by wax milling method and digital light projection method of CAD/CAM systems. Methods: All the specimens were fabricated by three different fabrication methods: conventional wax up with casting(CWC), milled wax block with casting(MWC), digital light projection with casting(DLPC) (n=10 each). The marginal and internal fits of specimens were examined using a replica technique. The light-body silicone thickness was measured at 8 reference points(each abutment: 16 measurements). All measurements were conducted by a stereomicroscope. Digital photo were taken at $150{\times}$ magnification and then analyzed using a measurement software. The Mann-Whitney test was used for analyzing the results. Results: Statistically significant differences were found between the fabrication methods(p<0.001). The mean(SD) is ${\mu}m$ for fabrication methods, the mean marginal fit were recorded respectively, CWC 63(38), MWC group 50(33), DLPC 103(54) and the mean internal fit CWC 96(47), MWC group 116(41), DLPC 138(66). Conclusion : The marginal and internal fit were statistically different according to the fabrication methods(p<0.001). In all fabrication methods, the greatest misfit was found the occlusal area of all specimens.

High performance active tuned mass damper inerter for structures under the ground acceleration

  • Li, Chunxiang;Cao, Liyuan
    • Earthquakes and Structures
    • /
    • v.16 no.2
    • /
    • pp.149-163
    • /
    • 2019
  • By integrating an active tuned mass damper (ATMD) and an inerter, the ATMDI has been proposed to attenuate undesirable oscillations of structures under the ground acceleration. Employing the mode generalized system, the dynamic magnification factors (DMF) of the structure-ATMDI system are formulated. The criterion can then be defined as the minimization of maximum values of the DMF of the controlled structure for optimum searching. By resorting to the defined criterion and the particle swarm optimization (PSO), the effects of varying the crucial parameters on the performance of ATMDI have been scrutinized in order to probe into its superiority. Furthermore, the results of both ATMD and tuned mass dampers inerter (TMDI) are included into consideration for comparing. Results corroborate that the ATMDI outperforms both ATMD and TMDI in terms of the effectiveness and robustness. Especially, the ATMDI may greatly reduce the demand on both the mass ratio and inerter mass ratio, thus being capable of further miniaturizing both the ATMD and TMDI. Likewise the miniaturized ATMDI still keeps nearly the same stroke as the TMDI with a larger mass ratio. Hence, the ATMDI is deemed to be a high performance control device with the miniaturization and suitable for super-tall buildings.