• 제목/요약/키워드: magnetic resonance image(MRI)

검색결과 571건 처리시간 0.028초

자기공명영상을 이용한 복숭아 및 씨의 부피 측정과 3차원 가시화 (Peach & Pit Volume Measurement and 3D Visualization using Magnetic Resonance Imaging Data)

  • 김철수
    • Journal of Biosystems Engineering
    • /
    • 제27권3호
    • /
    • pp.227-234
    • /
    • 2002
  • This study was conducted to nondestructively estimate the volumetric information of peach and pit and to visualize the 3D information of internal structure from magnetic resonance imaging(MRI) data. Bruker Biospec 7T spectrometer operating at a proton reosonant frequency of 300 MHz was used for acquisition of MRI data of peach. Image processing algorithms and visualization techniques were implemented by using MATLAB (Mathworks) and Visualization Toolkit(Kitware), respectively. Thresholding algorithm and Kohonen's self organizing map(SOM) were applied to MRI data fur region segmentation. Volumetric information were estimated from segemented images and compared to the actual measurements. The average prediction errors of peach and pit volumes were 4.5%, 26.1%, respectively for the thresholding algorithm. and were 2.1%, 19.9%. respectively for the SOM. Although we couldn't get the statistically meaningful results with the limited number of samples, the average prediction errors were lower when the region segmentation was done by SOM rather than thresholding. The 3D visualization techniques such as isosurface construction and volume rendering were successfully implemented, by which we could nondestructively obtain the useful information of internal structures of peach.

Pictorial Review of Mediastinal Masses with an Emphasis on Magnetic Resonance Imaging

  • Jin Wang Park;Won Gi Jeong;Jong Eun, Lee;Hyo-jae Lee;So Yeon Ki;Byung Chan Lee;Hyoung Ook Kim;Seul Kee Kim;Suk Hee Heo;Hyo Soon Lim;Sang Soo Shin;Woong Yoon;Yong Yeon Jeong;Yun-Hyeon Kim
    • Korean Journal of Radiology
    • /
    • 제22권1호
    • /
    • pp.139-154
    • /
    • 2021
  • Magnetic resonance imaging (MRI) has become a crucial tool for evaluating mediastinal masses considering that several lesions that appear indeterminate on computed tomography and radiography can be differentiated on MRI. Using a three-compartment model to localize the mass and employing a basic knowledge of MRI, radiologists can easily diagnose mediastinal masses. Here, we review the use of MRI in evaluating mediastinal masses and present the images of various mediastinal masses categorized using the International Thymic Malignancy Interest Group's three-compartment classification system. These masses include thymic hyperplasia, thymic cyst, pericardial cyst, thymoma, mediastinal hemangioma, lymphoma, mature teratoma, bronchogenic cyst, esophageal duplication cyst, mediastinal thyroid carcinoma originating from ectopic thyroid tissue, mediastinal liposarcoma, mediastinal pancreatic pseudocyst, neurogenic tumor, meningocele, and plasmacytoma.

자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과) (Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect))

  • 최우전;김동현
    • 한국방사선학회논문지
    • /
    • 제12권3호
    • /
    • pp.335-341
    • /
    • 2018
  • 의료수준의 향상과 더불어 환자들의 첨단의료장비에 대한 기대수준이 증가하고 있으며 특히 자기공명영상(Magnetic Resonance Image : MRI)은 현재 모든 임상 분야에서 가장 핵심적인 영상진단 도구로서 사용되고 있다. 그러나 검사 중에 발생하는 심각한 소음으로 많은 환자가 심리적인 불안을 경험한다고 한다. 이에 본 연구에서는 자기공명영상검사실의 기존 헤드셋 흡음재에서 차음재를 추가한 헤드셋의 소음저감평가와 차음재별 영상 아티팩트(artifact) 유무를 알아보고자 하였다. 3D 프린팅한 헤드셋 내부에 흡음재(스펀지)와 차음재(아크릴판, 구리판, 3D copper plate)를 교차 배열하여 MRI 검사소음을 녹음하여 스피커로 같은 dB 값의 소음을 발생시키며 3D 프린팅 된 두부모형의 내부에 소음측정기로 dB 값을 측정하여 정량분석을 하며 자체 제작한 헤드셋을 물팬텀에 밀착시킨 후 MRI영상 아티팩트 유무를 검사한다. 드셋의 정량평가를 한 결과, 헤드셋 평균 dB 값은 81.8 dB로 나타났으며, 차음재를 추가한 헤드셋에서 가장 방음효과가 뛰어난 재료조합(구리, 아크릴판, 스펀지, 스펀지) 헤드셋의 평균 dB 값은 70.4 dB 값이 측정되었지만 MRI 시뮬레이션 결과 구리가 반자성체이기 때문에 아티팩트가 나타나 배제하였고 두 번째로 방음효과가 뛰어난 (스펀지, 아크릴판, e-copper plate, 스펀지) 헤드셋의 평균 dB 값은 70.6 dB 값이 측정되었고 MRI 시뮬레이션 결과 인공물 나타나지 않았다. 구리분말이 약 40%가 포함된 e-copper PLA로 출력한 재료를 동일하게 시뮬레이션을 한 결과 인공물 나타나지 않았으므로 3D 프린팅 재료의 사용이 적합하였고 구리보다 경제성이 우수하며 가공이 용이하므로 적합한 재료로 선정하였다. MRI관련 연구에 있어 3D 프린팅을 이용한 상호발전이 매우 기대된다.

Prior to Breast MRI Guidelines in Korea, Where Were We?

  • Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.35-42
    • /
    • 2021
  • Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.

Hepatic Lymphoma Representing Iso-Signal Intensity on Hepatobiliary Phase, in Gd-EOB-DTPA-Enhanced MRI: Case Report

  • Ahn, Tae-Ran;Kim, Yeo-Eun;Park, Chul-Hi;Jung, Eun-Ah
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권3호
    • /
    • pp.200-204
    • /
    • 2015
  • Image findings of hepatic lymphoma have been reported as variable, ranging from single or multiple small nodules to diffuse infiltrative patterns. On MRI, most hepatic lymphomas show T1 low signal intensity, T2 high signal intensity. Dynamic imaging reveals a hypointense appearance in the arterial phase, followed by delayed enhancement in the portal venous and transitional phase. In the hepatobiliary phase using a hepatocyte-specific contrast agent (which have recently aided in increasing the access to the focal liver lesions), hepatic lymphoma is known to exhibit low signal intensity. We report a case of hepatic lymphoma, which shows iso-signal intensity on hepatobiliary phase, using gadoxetic acid (Gd-EOB-DTPA).

자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究) (A Study on Locational Control of Motion Ghost in Magnetic Imaging System)

  • 이후민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

척추동맥폐색의 기전 확인에서 고해상도MRI의 유용성:증례 보고 (Usefulness of High Resolution MRI in Confirmation of Mechanism:A Case Report)

  • 허욱;강현구
    • 한국산학기술학회논문지
    • /
    • 제19권7호
    • /
    • pp.239-244
    • /
    • 2018
  • 뇌경색의 주요 원인인 동맥 박리와 죽상경화증으로 인한 동맥 폐색 모두 고식적 자기공명혈관조영술이나 컴퓨터단층혈관조영술에서 혈관이 막힌 것처럼 보이지만, 발생 기전이 다르기 때문에 치료 방향에 차이가 생길 수 있다. 최근 고해상도MRI가 발달하면서 비침습적으로 혈관벽의 영상을 확인할 수 있게 되었다. 임상적으로 혹은 영상학적으로 동맥 박리가 의심되는 환자에게 고해상도MRI는 매우 유용한 검사방법으로 자리 잡고 있으나, 아직 두 질환의 감별점이 완전히 적립 되지는 않았다. 저자들은 컴퓨터단층혈관조영술에서 척추동맥폐색이 관찰된 두 환자에서 고해상도MRI를 통해 척추동맥박리와 죽상경화증의 차이점을 찾아보았고, 이를 추적 관찰하였다. 지금까지 알려진 혈관벽의 형태, 내막 판, 이중 내막, 혈관벽내 혈종, 가성 동맥류, 동맥벽의 초승달 모양 고신호 강도와 같은 동맥박리의 특징뿐만 아니라 저자들이 경험한 증례와 같이 긴 협착 길이, 폐쇄 부위 혈관의 재개통도 동맥 박리를 시사하는 소견이라고 판단하였다. 고해상도MRI를 통해 확인된 추가적인 동맥박리의 특징과 함께 향후 다양한 연구들을 통해 진단 기준이 명확해 진다면 치료에 많은 도움을 줄 수 있을 것으로 생각한다.

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • 제19권4호
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

자화율 차이로 인해 왜곡된 영상으로부터 금속 바늘의 위치 결정 (Determining the Location of Metallic Needle from MR Images Distorted by Susceptibility Difference)

  • 김은주;김대홍
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.87-94
    • /
    • 2010
  • 목적: 금속에 의한 영상 왜곡에 대한 정확한 계산하고 영상으로부터의 금속 물질의 위치 결정한다. 대상 및 방법: 주자기장과 일정 각도를 이루는 무한히 긴 비자성 금속 실린더에 대한 라플라스 방정식을 풀고, 이 결과를 이용하여 절편선택 경사자계와 주파수 부호화 경사자계에 의한 영상에 왜곡을 계산한다. 계산 결과를 바탕으로 하여 왜곡된 영상으로부터 원통형 보철물의 위치를 계산한다. 결과: Folded point와 금속 실린더의 중심 사이의 거리를 영상으로부터 측정하여 계산 결과와 비교한다. 측정 결과와 계산 결과 간의 퍼센트 오차는 한 경우를 제외하고 5% 이내였다. 결론: 금속 실린더가 자기장 하에 있을 때, 영상의 왜곡을 시뮬레이션 하였고, 이 기술은 생검술 또는 외과 수술 등을 자기공명영상법을 이용여 실시간 모니터링하는데 적용할 수 있을 것으로 기대한다.

오류 역전파 알고리즘을 이용한 자기 공명 영상 자동 세그멘테이션 (Automatic segmentation of magnetic resonance images using error back-propagation algorithm)

  • 최재호;조범준
    • 한국통신학회논문지
    • /
    • 제22권11호
    • /
    • pp.2425-2431
    • /
    • 1997
  • 자기 공명 영상의 사용이 빈번해 짐에 따라 환자의 해부학적인 정확한 정보와 이를 빠르고 효과적으로 진단하는데 유용한 자동 영상 세그멘테이션 방법이 요구되고 있다. 본 논문에서는 오류 역전파 알고리즘으로 학습한 신경망을 이용하여 뇌의 자기 공명 영상을 자동적으로 세그멘테이션하는 방법을 제안한다. 특정 환자의 자기 공명 영상을 분할하여 학습시킨 신경망은 다른 환자의 자기 공명 영상도 자동적으로 세그멘테이션하여 뇌의 윤곽을 뚜렷하게 나타내었다.

  • PDF