This study was conducted to nondestructively estimate the volumetric information of peach and pit and to visualize the 3D information of internal structure from magnetic resonance imaging(MRI) data. Bruker Biospec 7T spectrometer operating at a proton reosonant frequency of 300 MHz was used for acquisition of MRI data of peach. Image processing algorithms and visualization techniques were implemented by using MATLAB (Mathworks) and Visualization Toolkit(Kitware), respectively. Thresholding algorithm and Kohonen's self organizing map(SOM) were applied to MRI data fur region segmentation. Volumetric information were estimated from segemented images and compared to the actual measurements. The average prediction errors of peach and pit volumes were 4.5%, 26.1%, respectively for the thresholding algorithm. and were 2.1%, 19.9%. respectively for the SOM. Although we couldn't get the statistically meaningful results with the limited number of samples, the average prediction errors were lower when the region segmentation was done by SOM rather than thresholding. The 3D visualization techniques such as isosurface construction and volume rendering were successfully implemented, by which we could nondestructively obtain the useful information of internal structures of peach.
Jin Wang Park;Won Gi Jeong;Jong Eun, Lee;Hyo-jae Lee;So Yeon Ki;Byung Chan Lee;Hyoung Ook Kim;Seul Kee Kim;Suk Hee Heo;Hyo Soon Lim;Sang Soo Shin;Woong Yoon;Yong Yeon Jeong;Yun-Hyeon Kim
Korean Journal of Radiology
/
제22권1호
/
pp.139-154
/
2021
Magnetic resonance imaging (MRI) has become a crucial tool for evaluating mediastinal masses considering that several lesions that appear indeterminate on computed tomography and radiography can be differentiated on MRI. Using a three-compartment model to localize the mass and employing a basic knowledge of MRI, radiologists can easily diagnose mediastinal masses. Here, we review the use of MRI in evaluating mediastinal masses and present the images of various mediastinal masses categorized using the International Thymic Malignancy Interest Group's three-compartment classification system. These masses include thymic hyperplasia, thymic cyst, pericardial cyst, thymoma, mediastinal hemangioma, lymphoma, mature teratoma, bronchogenic cyst, esophageal duplication cyst, mediastinal thyroid carcinoma originating from ectopic thyroid tissue, mediastinal liposarcoma, mediastinal pancreatic pseudocyst, neurogenic tumor, meningocele, and plasmacytoma.
의료수준의 향상과 더불어 환자들의 첨단의료장비에 대한 기대수준이 증가하고 있으며 특히 자기공명영상(Magnetic Resonance Image : MRI)은 현재 모든 임상 분야에서 가장 핵심적인 영상진단 도구로서 사용되고 있다. 그러나 검사 중에 발생하는 심각한 소음으로 많은 환자가 심리적인 불안을 경험한다고 한다. 이에 본 연구에서는 자기공명영상검사실의 기존 헤드셋 흡음재에서 차음재를 추가한 헤드셋의 소음저감평가와 차음재별 영상 아티팩트(artifact) 유무를 알아보고자 하였다. 3D 프린팅한 헤드셋 내부에 흡음재(스펀지)와 차음재(아크릴판, 구리판, 3D copper plate)를 교차 배열하여 MRI 검사소음을 녹음하여 스피커로 같은 dB 값의 소음을 발생시키며 3D 프린팅 된 두부모형의 내부에 소음측정기로 dB 값을 측정하여 정량분석을 하며 자체 제작한 헤드셋을 물팬텀에 밀착시킨 후 MRI영상 아티팩트 유무를 검사한다. 드셋의 정량평가를 한 결과, 헤드셋 평균 dB 값은 81.8 dB로 나타났으며, 차음재를 추가한 헤드셋에서 가장 방음효과가 뛰어난 재료조합(구리, 아크릴판, 스펀지, 스펀지) 헤드셋의 평균 dB 값은 70.4 dB 값이 측정되었지만 MRI 시뮬레이션 결과 구리가 반자성체이기 때문에 아티팩트가 나타나 배제하였고 두 번째로 방음효과가 뛰어난 (스펀지, 아크릴판, e-copper plate, 스펀지) 헤드셋의 평균 dB 값은 70.6 dB 값이 측정되었고 MRI 시뮬레이션 결과 인공물 나타나지 않았다. 구리분말이 약 40%가 포함된 e-copper PLA로 출력한 재료를 동일하게 시뮬레이션을 한 결과 인공물 나타나지 않았으므로 3D 프린팅 재료의 사용이 적합하였고 구리보다 경제성이 우수하며 가공이 용이하므로 적합한 재료로 선정하였다. MRI관련 연구에 있어 3D 프린팅을 이용한 상호발전이 매우 기대된다.
Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
Investigative Magnetic Resonance Imaging
/
제25권1호
/
pp.35-42
/
2021
Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.
Image findings of hepatic lymphoma have been reported as variable, ranging from single or multiple small nodules to diffuse infiltrative patterns. On MRI, most hepatic lymphomas show T1 low signal intensity, T2 high signal intensity. Dynamic imaging reveals a hypointense appearance in the arterial phase, followed by delayed enhancement in the portal venous and transitional phase. In the hepatobiliary phase using a hepatocyte-specific contrast agent (which have recently aided in increasing the access to the focal liver lesions), hepatic lymphoma is known to exhibit low signal intensity. We report a case of hepatic lymphoma, which shows iso-signal intensity on hepatobiliary phase, using gadoxetic acid (Gd-EOB-DTPA).
Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.
뇌경색의 주요 원인인 동맥 박리와 죽상경화증으로 인한 동맥 폐색 모두 고식적 자기공명혈관조영술이나 컴퓨터단층혈관조영술에서 혈관이 막힌 것처럼 보이지만, 발생 기전이 다르기 때문에 치료 방향에 차이가 생길 수 있다. 최근 고해상도MRI가 발달하면서 비침습적으로 혈관벽의 영상을 확인할 수 있게 되었다. 임상적으로 혹은 영상학적으로 동맥 박리가 의심되는 환자에게 고해상도MRI는 매우 유용한 검사방법으로 자리 잡고 있으나, 아직 두 질환의 감별점이 완전히 적립 되지는 않았다. 저자들은 컴퓨터단층혈관조영술에서 척추동맥폐색이 관찰된 두 환자에서 고해상도MRI를 통해 척추동맥박리와 죽상경화증의 차이점을 찾아보았고, 이를 추적 관찰하였다. 지금까지 알려진 혈관벽의 형태, 내막 판, 이중 내막, 혈관벽내 혈종, 가성 동맥류, 동맥벽의 초승달 모양 고신호 강도와 같은 동맥박리의 특징뿐만 아니라 저자들이 경험한 증례와 같이 긴 협착 길이, 폐쇄 부위 혈관의 재개통도 동맥 박리를 시사하는 소견이라고 판단하였다. 고해상도MRI를 통해 확인된 추가적인 동맥박리의 특징과 함께 향후 다양한 연구들을 통해 진단 기준이 명확해 진다면 치료에 많은 도움을 줄 수 있을 것으로 생각한다.
Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
Investigative Magnetic Resonance Imaging
/
제19권4호
/
pp.224-230
/
2015
Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.
목적: 금속에 의한 영상 왜곡에 대한 정확한 계산하고 영상으로부터의 금속 물질의 위치 결정한다. 대상 및 방법: 주자기장과 일정 각도를 이루는 무한히 긴 비자성 금속 실린더에 대한 라플라스 방정식을 풀고, 이 결과를 이용하여 절편선택 경사자계와 주파수 부호화 경사자계에 의한 영상에 왜곡을 계산한다. 계산 결과를 바탕으로 하여 왜곡된 영상으로부터 원통형 보철물의 위치를 계산한다. 결과: Folded point와 금속 실린더의 중심 사이의 거리를 영상으로부터 측정하여 계산 결과와 비교한다. 측정 결과와 계산 결과 간의 퍼센트 오차는 한 경우를 제외하고 5% 이내였다. 결론: 금속 실린더가 자기장 하에 있을 때, 영상의 왜곡을 시뮬레이션 하였고, 이 기술은 생검술 또는 외과 수술 등을 자기공명영상법을 이용여 실시간 모니터링하는데 적용할 수 있을 것으로 기대한다.
자기 공명 영상의 사용이 빈번해 짐에 따라 환자의 해부학적인 정확한 정보와 이를 빠르고 효과적으로 진단하는데 유용한 자동 영상 세그멘테이션 방법이 요구되고 있다. 본 논문에서는 오류 역전파 알고리즘으로 학습한 신경망을 이용하여 뇌의 자기 공명 영상을 자동적으로 세그멘테이션하는 방법을 제안한다. 특정 환자의 자기 공명 영상을 분할하여 학습시킨 신경망은 다른 환자의 자기 공명 영상도 자동적으로 세그멘테이션하여 뇌의 윤곽을 뚜렷하게 나타내었다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.