• 제목/요약/키워드: magnetic particle

검색결과 600건 처리시간 0.03초

자기연마법을 응용한 미세금형부품의 초정밀 연마 (Ultra Precision Polishing of Micro Die and Mold Parts using Magnetic-assisted Machining)

  • 안병운;김욱배;박성준;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1832-1835
    • /
    • 2003
  • This paper suggests the selective ultra precision polishing techniques for micro die and mold parts using magnetic-assisted machining. Fabrication of magnetic abrasive particle and their polishing performance are key technology at ultra precision polishing process of micro parts. Conventional magnetic abrasives have disadvantages. which are missing of abrasive particle and inequality between magnetic particle and abrasive particle. So, bonded magnetic abrasive particles are fabricated by several method. For example, plasma melting and direct bonding. Ferrite and carbonyl iron powder are used as magnetic particle where silicon carbide and Al$_2$O$_3$ are abrasive particle. Developed particles are analyzed using measurement device such as SEM. Possibility of magnetic abrasive and polishing performance of this magnetic abrasive particles also have been investigated. After polishing, surface roughness of workpiece is reduced from 2.927 $\mu\textrm{m}$ Rmax to 0.453 $\mu\textrm{m}$ Rmax.

  • PDF

결합된 자성연마입자를 이용한 초정밀 피니싱 기술 개발 (Development of Ultraprecision Finishing Technique using Bonded Magnetic Abrasives)

  • 윤종학;박성준;안병운
    • 한국공작기계학회논문집
    • /
    • 제12권5호
    • /
    • pp.59-66
    • /
    • 2003
  • This study suggests the new ultraprecision finishing techniques for micro die and mold parts using magnetic field-assisted polishing. Conventional magnetic abrasives have several disadvantages, which are missing of abrasive particle and inequal mixture between magnetic particle and abrasive particle. Therefore, bonded magnetic abrasive particles are fabricated by several method. For example, plasma melting and direct bonding. Carbonyl iron powder is used as magnetic particle there silicon carbide and alumina are abrasive particles. Developed magnetic abrasives are analyzed using SEM. Feasibility of magnetic abrasive and polishing performance of this magnetic abrasive particles also have been investigated. After polishing, surface roughness of workpiece is reduced from 85.4 ㎚ Ra to 9 ㎚ RA.

자기 Tape의 전자 변환 특성에 대한 자성분의 Size와 그 특성의 영향 (The Influence of Magnetic Particle Size and Its Properties on The Electromagnetic Particle in Magnetic Tape)

  • 김상문;김태옥
    • 한국자기학회지
    • /
    • 제6권5호
    • /
    • pp.334-339
    • /
    • 1996
  • 도포형 자기기록매체에 있어서 자성분의 size와 특성이 자기기록 특성에 미치는 영향을 조사하기위하여 size가 다른 각각의 자성분으로 만든 도료를 이용하여 자기 tape를 제조하고 자성분의 분산성 및 전자 변환 특성을 측정하였다. 자성분의 분산성은 입자 size의 영향보다 입자의 형태 및 자성분의 표면화학특성에 크게 의존하며 자성분의 입자 size가 작아질 수록 자성분의 충진성은 향상 되고 tape의 remanence 특성과 출력 특성 및 noise 특성이 향상되어 고출력, 저 noise의 넓은 dynamic range의 출력이 나타남을 확인하였다. 따라서 고출력의 자기 tape를 제조하기 위하여는 자성분의 size, 형상, 표면화학 특성 및 자기특성이 자성분 선정의 중요한 요건임을 확인하였다.

  • PDF

Theoretical Study on Magnetic Field Application for Fine Particle Capture

  • Huang, Shan;Park, Haewoo;Jo, Youngmin
    • 한국입자에어로졸학회지
    • /
    • 제10권2호
    • /
    • pp.45-51
    • /
    • 2014
  • Fine particle capture is facing a challenge since traditional filtration which relies on the combination of impaction, interception, diffusion has a limited efficiency for fine particle capture particularly in size from 0.1 to $0.5{\mu}m$. This paper reviewed the collection efficiency of above mechanisms, as well as magnetic mechanisms for ferromagnetic particles, and mainly studied the influencing factors of magnetic filtration. Filtration velocity, magnetic field intensity and fiber size were found to be the most important parameters for magnetic filtration.

자화된 플라즈마 내에서의 단분산 입자의 하전량 특정 (Measurement of Monodisperse Particle Charging in Unmagnetized and Magnetized Plasmas)

  • 한장식;안강호;김곤호
    • 반도체디스플레이기술학회지
    • /
    • 제1권1호
    • /
    • pp.35-40
    • /
    • 2002
  • Understanding of charging properties of a small particle is necessary to control the particle contamination and to improve productivity of the electronic device in the plasma aided semiconductor manufacturing processes. In this study, the effects of both magnetic field and particle size on the charging properties are experimentally investigated in collisional dusty plasmas. The experiments carried out in the system consisted of a monodisperse particle generation system, a DC magnetized plasma generation system and a charge measurement system. The plasma chamber is made of cross-shape Pyrex surrounded by magnetic bucket (composed of 12 permanent magnetic bar) to confine the plasma. DC magnetic field up to 250G are applied to the plasma zone by external magnetic coil. Previous work shows the charging effect clearly increase with increasing the size of the particle and plasma density, as it was expected.

  • PDF

Magnetic Reactive Particle 코팅 및 인가전류에 따른 Magnetorheological Elastomer 의 전단계수 측정 (Experimental Evaluation on Shear Modulus of MRE due to MRP Coating and Induced Current)

  • 오재응;정운창;김진수;윤정민;노정준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.927-929
    • /
    • 2014
  • MRE(Magneto-rheological Elastomer) is a material which shows reversible and various modulus in magnetic field. Comparing to conventional rubber vibration isolator, MREs are able to absorb broader frequency range of vibration. These characteristic phenomena result from the orientation of magnetic particle (i.e., chain-like formation). Magnetic reactive powder(MRP), having rapid magnetic reaction, was selected as a magnetic particle to give magnetic field reactive modulus. The mechanical properties of manufactured MREs were measured with the application of magnetic field. The analysis of MR effect was carried out by FFT analyzer with various induced current. As induced magnetic field intensity increased and coated with MRP, increment of MR effect was observed.

  • PDF

Development of volume reduction method of cesium contaminated soil with magnetic separation

  • Yukumatsu, Kazuki;Nomura, Naoki;Mishima, Fumihito;Akiyama, Yoko;Nishijima, Shigehiro
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제18권1호
    • /
    • pp.10-13
    • /
    • 2016
  • In this study, we developed a new volume reduction technique for cesium contaminated soil by magnetic separation. Cs in soil is mainly adsorbed on clay which is the smallest particle constituent in the soil, especially on paramagnetic 2:1 type clay minerals which strongly adsorb and fix Cs. Thus selective separation of 2:1 type clay with a superconducting magnet could enable to reduce the volume of Cs contaminated soil. The 2:1 type clay particles exist in various particle sizes in the soil, which leads that magnetic force and Cs adsorption quantity depend on their particle size. Accordingly, we examined magnetic separation conditions for efficient separation of 2:1 type clay considering their particle size distribution. First, the separation rate of 2:1 type clay for each particle size was calculated by particle trajectory simulation, because magnetic separation rate largely depends on the objective size. According to the calculation, 73 and 89 % of 2:1 type clay could be separated at 2 and 7 T, respectively. Moreover we calculated dose reduction rate on the basis of the result of particle trajectory simulation. It was indicated that 17 and 51 % of dose reduction would be possible at 2 and 7 T, respectively. The difference of dose reduction rate at 2 T and 7 T was found to be separated a fine particle. It was shown that magnetic separation considering particle size distribution would contribute to the volume reduction of contaminated soil.

Magnetic withdrawal of particles for multiple purposes in nuclear power plants

  • Kam, Dong Hoon;Jeong, Yong Hoon;Choi, Sung-Min;Yun, Jong-Il
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.3979-3989
    • /
    • 2021
  • Several parametric effects on the magnetic collection have been evaluated considering dimension, strength of external magnetic field, injected velocity and particle concentration in the working fluid. Besides, accidental environments, expected in the containment of nuclear power plants, have also been addressed for the capture efficiency. The capture efficiency is especially enhanced with magnetic particle size and magnetic field strength through increased magnetic force; the non-magnetic coating thickness and fluid velocity hinder the magnetic collection. Based on the assessment, the magnetic withdrawal system can effectively capture magnetic particles even under accidental environments. Withdrawal of multifunctional magnetic particles or filtering of magnetic impurities can be effectively realized through the system.

Bending Strength of Textured Alumina Prepared by Slip Casting in a Strong Magnetic Field

  • Suzuki, Tohru S.;Uchikoshi, Tetsuo;Morita, Koji;Hirage, Keijiro;Sakka, Yoshio
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1099-1100
    • /
    • 2006
  • The mechanical properties of ceramics materials can be tailored by designing their microstructures. We have reported that development of texture can be controlled by slip casting in a strong magnetic field followed by heating even for diamagnetic ceramics such as alumina. A strong magnetic field of 12T was applied to the suspension indcuding alumina powder to rotate each particle during slip casting. The sintering was conducted at the desired temperature in air without a magnetic field. C-axis of alumina was parallel to the magnetic field. Bending strength of textured alumina depended on the direction of oriented microstructure.

  • PDF

코팅처리 용접부의 자기탐상시험방법에 대한 연구 (A Study On the Magnetic Particle Testing Method for Coated Welding points)

  • 최정수;김종희
    • 한국재난정보학회 논문집
    • /
    • 제4권1호
    • /
    • pp.102-136
    • /
    • 2008
  • Coated welding points are eliminated for Open-Inspection of above-ground storage tanks which should be inspected periodically in accordance with the Hazmat-treatment Safety Act. But it was speculated on this study that it causes such huge economical losses in terms of manpower and materials that applicable to magnetic particle testing. As a result, it was concluded that the magnetic particle testing is applicable to the coating depth below $50{\mu}m$.

  • PDF